Geology Reports⌕ Search

USGS · sir20115149

Simulations of groundwater flow and particle-tracking analysis in the zone of contribution to a public-supply well in San Antonio, Texas

Abstract

In 2006, a public-supply well in San Antonio, Texas, was selected for intensive study to assess the vulnerability of public-supply wells in the Edwards aquifer to contamination by a variety of compounds. A local-scale, steady-state, three-dimensional numerical groundwater-flow model was developed and used in this study to evaluate the movement of water and solutes from recharge areas to the selected public-supply well. Particle tracking was used to compute flow paths and advective traveltimes throughout the model area and to delineate the areas contributing recharge and zone of contribution for the selected public-supply well. The local-scale model grid has a finer vertical discretization than do previous regional Edwards aquifer models and incorporates refined parameter zones corresponding with multiple (10) hydrogeologic units representing the Edwards aquifer. In the Edwards aquifer, high matrix porosity and permeability likely are overshadowed by high permeability developed in structurally influenced karstic conduit systems that transmit water into, through, and out of the aquifer system. The complexity of the aquifer system in the local-scale study area is further increased by numerous faults with varying vertical displacements. The extensive faulting results in the juxtaposition of hydrogeologic units with differing hydraulic properties and has appreciable effects on groundwater flow in the Edwards aquifer. The local-scale model simulations use the MODFLOW Hydrogeologic-Unit Flow Package and include two hydrogeologic units with high hydraulic conductivities (one or more orders of magnitude higher than for the other simulated hydrogeologic units) that are intended to simulate fast flow paths attributable to karst features. The two “conduit” hydrogeologic units of the Edwards aquifer represent the lower 8 meters of the leached and collapsed members and the Kirschberg evaporite member of the Edwards Group. The MODFLOW Horizontal-Flow Barrier Package was used to simulate faults in the local-scale model. The assumption was made that the degree to which a fault acts as a barrier to groundwater flow is proportional to the fault displacement. The final calibrated hydraulic-conductance values ranged from 0.01 to 0.2 per day for fault displacements ranging from 0 to more than 100 percent of the total aquifer thickness. The calibrated steady-state simulation generally reproduces the spatial distribution of measured water-level altitudes. Simulated water-level altitudes were within 9.0 meters of measured water-level altitudes at 74 of the 84 wells used as targets for the local-scale model for the calibrated steady-state simulation. The overall mean absolute difference between simulated and measured water-level altitudes is 4.2 meters, and the mean algebraic difference is 1.9 meters. The simulated springflow for San Antonio Springs was 7.7 percent greater and for San Pedro Springs was 4.2 percent less than the median measured springflow. Simulated tritium concentrations were within 0.14 tritium units of measured tritium concentrations for 11 of the 13 local-scale study tritium observations from the 10 local-scale study wells used to calibrate the steady-state local-scale model, with a mean absolute difference between simulated and measured tritium concentrations of 0.11 tritium units and a mean algebraic difference of -0.04 tritium units. Simulated tritium concentrations in the selected public-supply well during November 2007 were within 0.09 tritium units of the measured concentrations, with the exception of the shallowest observation from the well. The steady-state simulation water budget indicates that recharge occurring in the local-scale study area accounts for 31.8 percent of the sources of water to the Edwards aquifer in the local-scale model area and that inflow through the model boundaries contributes 68.2 percent. Most of the flow into the local-scale model area through the model boundaries occurs through the western and southern boundaries, 58.2 and 39.6 percent, respectively. The largest discharges from the Edwards aquifer in the local-scale model area are boundary outflow (71.4 percent) and withdrawals by wells (24.9 percent). Most of the flow out of the local-scale model area through the model boundaries occurs through the southern and eastern boundaries, 54.2 and 39.6 percent, respectively. The simulated zones of contribution for the selected public-supply well, Timberhill well nest, and Zarzamora well nest extend to the north, northeast, and northwest from each site in the confined zone of the aquifer into the recharge zone, where all recharge to the aquifer occurs. The area contributing recharge for the selected public-supply well has the greatest extent. The area contributing recharge for the Timberhill well nest encompasses approximately the western one-half of the area contributing recharge for the selected public-supply well, and that for the Zarzamora well nest encompasses approximately the eastern two-thirds of the area contributing recharge for the selected public-supply well. Simulated particle ages ranged from less than 1 day to more than 1,900 years in the 10 local-scale study wells (13 local-scale study tritium observations) used to calibrate the local-scale model. The simulated mean particle ages for the tritium observations representing selected well depths (shallow, intermediate, and deep) ranged from 2.5 to 15 years. The minimum (youngest) mean particle ages for the selected public-supply well and the Timberhill monitoring wells were for the intermediate well depth, while the youngest mean particle age for the Zarzamora monitoring wells was for the intermediate and deep well depth. The maximum (oldest) mean particle ages for the selected public-supply well and the Zarzamora monitoring wells were for the shallow well depth. The mean of simulated particle ages for tritium observations representing well depths open to the simulated conduit hydrogeologic units was 3.8 years, whereas the mean of simulated particle ages for tritium observations representing well depths not open to the simulated conduit hydrogeologic units was 9.6 years. The effect of short-circuit pathways, for example karst conduits, in the flow system on the movement of young water to the selected public-supply well could greatly alter contaminant arrival times compared to what might be expected from advection in a system without short circuiting. In a forecasting exercise, the simulated concentrations showed rapid initial response at the beginning and end of chemical input, followed by more gradual response as older water moved through the system. The nature of karst groundwater flow, where flow predominantly occurs via conduit flow paths, could lead to relatively rapid water quality responses to land-use changes. Results from the forecasting exercise indicate that timescales for change in the quality of water from the selected public-supply well could be on the order of a few years to decades for land-use changes that occur over days to decades, which has implications for source-water protection strategies that rely on land-use change to achieve water-quality objectives.

Explore related subjects

90° N90° S · 180° W ← longitude → 180° E
Source-reported bounding extent: 27.5° to 31° latitude; -101° to -97° longitude. This indicates report coverage, not an exact sampling location. View area on OpenStreetMap.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Richard L. Lindgren, Natalie A. Houston, MaryLynn Musgrove, Lynne S. Fahlquist, Leon J. Kauffman. 2011. Simulations of groundwater flow and particle-tracking analysis in the zone of contribution to a public-supply well in San Antonio, Texas. https://doi.org/10.3133/sir20115149

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

Baseline water-quality inventory and summary for the Paterson Great Falls National Historical Park, New Jersey

The Paterson Great Falls National Historical Park (PAGR), established in 2011 in the City of Paterson, New Jersey, contains many cultural, historical, and natural resources. Because of the PAGR’s young age and limited resources, a long record of natural resource data is not available for use to guide future park management and planning decisions. A detailed natural resource inventory was identified as an immediate need in the “Foundation Document—Paterson Great Falls National Historical Park,” given the history of extensive industrial activity throughout the PAGR and the Passaic River Basin. The U.S. Geological Survey, in cooperation with the National Park Service and the Urban Waters Federal Partnership for the Lower Passaic River, inventoried water-quality monitoring efforts and compiled historical water-quality data from secondary data sources to define baseline conditions in the PAGR and the surrounding study area. This report documents the methods used to harmonize water-quality data aggregated from multiple sources for the PAGR study area. Procedures implemented during data harmonization include compiling data from multiple sources, assessing the dataset for completeness, addressing metadata concerns, and creating a consistent and quality-assured dataset for future analysis. The harmonized dataset contains 14 aggregated surface-water sites, 1,103 individual sampling days, and 32,000 water-quality records throughout the period of record defined for this study (1952–2021). Summary statistics and comparison to water-quality criteria are provided for focus parameters that can support PAGR management, including field properties, suspended material, total dissolved solids, specific conductance, chloride, sulfate, Escherichia coli, nutrients, contaminants of concern related to fish consumption advisories, and litter and floatable debris. A spatial data gap was identified for the recreational area near the base of the Great Falls and immediately downstream from a known combined sewer overflow discharge location. Analytic data gaps were identified for continuous streamflow and water-quality parameters, floatable debris characterization, and harmful algal blooms identification. Continuous collection of contaminants of concern was identified as a temporal data gap, as these parameters were not consistently collected within the study area. The water-quality data synthesis and summary presented in this report can assist PAGR staff in understanding the complex baseline water resources within the study area and can serve as a baseline to design future water-quality monitoring efforts and evaluate changes in water quality over time. The harmonized dataset, as well as future New Jersey Department of Environmental Protection and New Jersey Harbor Discharge Group monitoring data and assessments, can also be used to examine the status and trends in surface-water quality, support compliance with the Clean Water Act (33 U.S.C. 1251 et seq.), and further investigate changes to park water resources that can affect ecological and human health.

New Jersey↗

Slip tendency and dilation tendency of Quaternary faults in the Great Basin region, Arizona, California, Idaho, Nevada, Oregon, Utah, and Wyoming

This report presents the results of slip tendency and dilation tendency analysis of Quaternary faults in the Great Basin region, in the states of Arizona, California, Idaho, Nevada, Oregon, Utah, and Wyoming. This effort was undertaken as part of two studies: the U.S. Department of Energy Geothermal Technologies Office-funded Innovative Geothermal Exploration through Novel Investigations of Undiscovered Systems (INGENIOUS) project, which is a multidisciplinary, multi-institution effort to develop new methodologies and best practices to accelerate the discovery of new, commercially viable hydrothermal resources; and the U.S. Geological Survey Geothermal Resources Investigations Project. The goal of this work is to identify faults and fault segments that are appropriately oriented to be stress-loaded for slip or to dilate under the ambient stress conditions. Both conditions may make such faults more likely to host permeability and fluid flow relative to other faults in the region. Slip tendency and dilation tendency were calculated for all fault segments in the study area from the U.S. Geological Survey Quaternary Fault and Fold Database. Results demonstrate that faults with high slip tendency and dilation tendency are common in the Great Basin region. The areas containing many high slip tendency and dilation tendency fault segments are associated with high strain rates. These areas also host a relatively high proportion of the known hydrothermal systems. This indicates that faults with high slip tendency and dilation tendency in areas with high strain-rate are potentially most prospective for hosting hydrothermal systems. The database published in coordination with this report contains the slip tendency and dilation tendency results data, including the fault geometry and stress data used to calculate these quantities, for both the Great Basin study area and the smaller INGENIOUS study area.

Arizona, California, Idaho, Nevada, Oregon, Utah, ↗

A spatial analysis of the groundwater emergence flood hazard in Long Island, New York, and coastal areas surrounding Long Island Sound in New York, Connecticut, and Rhode Island

Long Island, New York, and nearby coastal areas surrounding Long Island Sound are densely populated and, like other coastal areas, are susceptible to flooding from several potential sources, including stormwater from precipitation events, tidal flooding and storm surge, and groundwater emergence flooding. Groundwater emergence fooding refers to the intersection of a rising water table with land surface or critical infrastructure. Many studies of flood drivers either neglect or only briefly discuss how shallow groundwater conditions may contribute to or exacerbate flood conditions. As a part of a comprehensive study of compound flood hazards in the coastal areas of Long Island and Long Island Sound, a spatial analysis was completed by the U.S. Geological Survey, in cooperation with the Environmental Protection Agency’s Long Island Sound Partnership, formerly called the Long Island Sound Study, using available regional datasets to characterize the potential hazard for groundwater emergence flooding. The approximately 3,100 square mile study area was subdivided into 11,407 grid cells that were 900 meters by 900 meters (approximately 3,000 feet by 3,000 feet), for the purpose of integrating the spatial datasets to calculate and map the groundwater emergence flood hazard. The depth to the water table, hydrologic soil groups, and National Land Cover Database were harmonized to the common grid. A groundwater emergence flood hazard score was calculated for each grid cell for current average conditions following a set of rules accounting for the depth to the water table and the percentage of area within each cell with slow infiltrating soils. A scenario with a higher sea-level position was also calculated for the Long Island part of the study area. The calculated groundwater emergence flood hazard score was reviewed in conjunction with the National Land Cover Database to identify developed areas and associated infrastructure that may be at risk of potential groundwater emergence flooding. Study results indicate that the groundwater emergence flood hazard is highest in coastal areas and near surface water where the water table is close to ground surface. Inland areas away from surface waterbodies are not likely to be exposed to groundwater emergence flooding. For Long Island, in the scenario with higher sea-level position, a greater groundwater emergence flood hazard is calculated for some locations closer to the coast and where land is submerged. Away from the coast and surface-water drainage, the groundwater emergence flood hazard is similar between the current average sea-level condition and the higher sea-level position scenario.

Connecticut, New York, Rhode Island↗