Geology ReportsSearch

USGS · sir20055205

Two-dimensional resistivity investigation of the North Cavalcade Street site, Houston, Texas, August 2003

Abstract

The North Cavalcade Street site was first developed for wood treating in 1946. By 1955, pentachlorophenol wood preservation services and other support facilities, such as creosote ponds, pentachlorophenol and creosote storage structures, various tanks, lumber sheds, a treatment facility, and other buildings had been added. In 1961, the property was closed. To protect public health and welfare and the environment from release or threatened releases of hazardous substances, the U.S. Environmental Protection Agency added the North Cavalcade Street site to the National Priorities List on October 5, 1984. Between September 1985 and November 1987, the U.S. Environmental Protection Agency conducted a remedial investigation which, through exploratory drilling, determined the locations of two contaminated source areas and a normal fault. During August 2003, the U.S. Geological Survey, in cooperation with the U.S. Environmental Protection Agency, conducted a two-dimensional (2D) resistivity investigation at the North Cavalcade Street site to provide additional characterization of the dense non-aqueous phase liquids and the lithologies that can influence contaminant migration. The 2D resistivity investigation used a capacitively coupled (CC) resistivity method as a reconnaissance tool to locate geophysical anomalies that could be associated with possible areas of creosote contamination. The inversion results of the CC resistivity survey identified resistive anomalies in the subsurface near the eastern and western contaminated source areas. A direct-current (DC) resistivity survey conducted near the CC resistivity survey confirmed the occurrence of subsurface resistive anomalies. The inversion results of the DC resistivity survey were used to define the subsurface distribution of resistivity at each line. Forward modeling was used as an interpretative tool to relate the subsurface distribution of resistivity from four DC resistivity lines to known, assumed, and hypothetical information on subsurface lithologies. The final forward models were used as an estimate of the true resistivity structure for the field data. The forward models and the inversion results of the forward models show the depth, thickness, and extent of strata as well as the resistive anomalies occurring along the four lines and the displacement of strata resulting from the Pecore Fault along two of the four DC resistivity lines. Ten additional DC resistivity lines show similarly distributed shallow subsurface lithologies of silty sand and clay strata. Eight priority areas of resistive anomalies were identified for evaluation in future studies. The interpreted DC resistivity data allowed subsurface stratigraphy to be extrapolated between existing boreholes resulting in an improved understanding of lithologies that can influence contaminant migration.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Wade H. Kress, Andrew Teeple. 2005. Two-dimensional resistivity investigation of the North Cavalcade Street site, Houston, Texas, August 2003. https://doi.org/10.3133/sir20055205

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

Monitoring recreation on federally managed lands and waters—Aspects of visitor use

Federally managed public lands and waters receive around 1 billion recreational visits each year. Data on these visitors can aid in guiding policy decisions, managing resources effectively, and communicating the economic contributions of lands and waters. This report explores the methods used by agencies to collect data on aspects of recreational visitor use to Federal lands and waters (apart from visitation numbers, which are the focus of a companion publication). Aspects of recreational visitor use include visitor demographics, recreational activity participation, visitor satisfaction, visitor attitudes and experiences, trip characteristics, and economic contributions. We review practices used to understand aspects of visitor use across seven Federal agencies, revealing similarities such as the use of visitor intercept surveys and coverage of similar topic areas, and differences in how survey programs are operationalized and how specific questions on visitor surveys are worded. We also evaluate emerging technologies, such as geolocated social media and mobile device location data, for their potential to aid in understanding aspects of visitor use. This report concludes with potential opportunities to enhance data collection and coordination, ensuring cost-effective data collection and informed decision making.

Scientific Investigations Report

Evaluation of best management practices at an edge-of-field site in the Eagle Creek watershed, Ohio, 2012–20

In 2010, the U.S. Geological Survey worked in partnership with the Great Lakes Restoration Initiative and the Natural Resources Conservation Service to identify farm fields in priority watersheds—watersheds critically important to Great Lake health. Intensive best management practices were implemented in five States to test the efficacy of best management practices, also referred to as agricultural conservation practices, to reduce sediment and nutrient runoff on agricultural fields. These fields were chosen as representatives of the priority watersheds because their farming practices and geographical conditions were common among farms in those watersheds. A farm site located near Findlay, Ohio, in the Eagle Creek watershed used two conservation practices, cover crop (Natural Resources Conservation Service practice standard 340) and variable rate technology (VRT; Natural Resources Conservation Service practice standard 590), which represent common practices in the Maumee priority watershed. This study monitored surface runoff and subsurface tile runoff at the Eagle Creek watershed site. The effects of cover crop and VRT nutrient application on sediment and nutrient runoff were assessed from October 2012 to September 2020. Cover crops were applied in fall of 2016, 2017, and 2018, coinciding with VRT applications. The following parameters were analyzed as part of the study: runoff discharge; peak discharge; and concentrations and loads of total phosphorus, particulate phosphorus, dissolved reactive phosphorus, and suspended sediment. High peak runoff events disproportionally affected nutrient concentrations and loads in runoff. A threshold of the 85th percentile of the peak discharge was chosen to assess the effect of cover crop and VRT nutrient application on nutrient mitigation at each gage. Runoff events below the 85th percentile were considered small, and runoff events over the 85th percentile were considered large. Concentrations from collected water-quality samples were used for the analysis; estimated concentrations were excluded from the statistical evaluation. All surface runoff parameters during small runoff events, except surface runoff volume, were significantly lower in the period with cover crops and VRT implementation. Contrarily, subsurface runoff parameters during small events were not statistically different between the periods with and without cover crops and VRT implementation. Surface and subsurface parameters during large events were also not statistically different between the periods with and without cover crops and VRT implementation. These results indicate cover crops and VRT may improve water quality during small runoff events, but additional best management practices that mitigate large runoff events may lead to greater water-quality improvement given the contribution of large events to overall losses.

Ohio

Continuous monitoring and temporal variability of fluorescence of dissolved organic matter in karst groundwater of the Edwards aquifer, south-central Texas, 2019–24

Widespread urbanization on the Edwards aquifer recharge zone in south-central Texas has prompted the development of new approaches and tools for evaluating the current and future status of water quality in the San Antonio and Barton Springs segments of the Edwards aquifer. The U.S. Geological Survey, in cooperation with the San Antonio Water System and the City of Austin, applied continuous monitoring of fluorescence of dissolved organic matter (fDOM) to characterize the sources and transport of dissolved organic matter and associated constituents in the Edwards aquifer. Continuous fDOM time-series data were adjusted using empirically derived temperature, turbidity, and inner-filter-effect correction factors prior to analysis and interpretation. Fully corrected fDOM time-series data from the study sites were evaluated for short- and long-term temporal variability in fDOM in the context of the hydrologic and climatic conditions that occurred during the 5-year study period to understand vulnerability of the aquifer to potential contaminants in recharge. Study results indicate that fDOM is an effective proxy for dissolved organic carbon that, in turn, is indicative of the influx of recent surface water and associated contaminants, and thus, aquifer vulnerability to those contaminants. Although other continuously monitored water-quality parameters provide insights into changes in water quality in response to varying hydrologic conditions, the quantitative relation between fDOM and dissolved organic carbon directly indicates the timing and magnitude of pulses of organic constituents derived from the land surface, whereas other water-quality parameters do not.

Texas