Geology Reports⌕ Search

USGS · sir20055039

Occurrence of fecal-indicator bacteria and protocols for identification of fecal-contamination sources in selected reaches of the West Branch Brandywine Creek, Chester County, Pennsylvania

Abstract

The presence of fecal-indicator bacteria indicates the potential presence of pathogens originating from the fecal matter of warm-blooded animals. These pathogens are responsible for numerous human diseases ranging from common diarrhea to meningitis and polio. The detection of fecal-indicator bacteria and interpretation of the resultant data are, therefore, of great importance to water-resource managers. Current (2005) techniques used to assess fecal contamination within the fluvial environment primarily assess samples collected from the water column, either as grab samples or as depth- and (or) width-integrated samples. However, current research indicates approximately 99 percent of all bacteria within nature exist as attached, or sessile, bacteria. Because of this condition, most current techniques for the detection of fecal contamination, which utilize bacteria, assess only about 1 percent of the total bacteria within the fluvial system and are, therefore, problematic. Evaluation of the environmental factors affecting the occurrence and distribution of bacteria within the fluvial system, as well as the evaluation and modification of alternative approaches that effectively quantify the larger population of sessile bacteria within fluvial sediments, will present water-resource managers with more effective tools to assess, prevent, and (or) eliminate sources of fecal contamination within pristine and impaired watersheds. Two stream reaches on the West Branch Brandywine Creek in the Coatesville, Pa., region were studied between September 2002 and August 2003. The effects of sediment particle size, climatic conditions, aquatic growth, environmental chemistry, impervious surfaces, sediment and soil filtration, and dams on observed bacteria concentrations were evaluated. Alternative approaches were assessed to better detect geographic sources of fecal contamination including the use of turbidity as a surrogate for bacteria, the modification and implementation of sandbag bacteria samplers, and the use of optical brighteners. For the purposes of this report, sources of bacteria were defined as geographic locations where elevated concentrations of bacteria are observed within, or expected to enter, the main branch of the West Branch Brandywine Creek. Biologic sources (for example, waterfowl) were noted where applicable; however, no specific study of biologic sources (such as bacterial source tracking) was conducted. Data indicated that specific bacterial populations within fluvial sediments could be related to specific particle-size ranges. This relation is likely the result of the reduced porosity and permeability associated with finer sediments and the ability of specific bacteria to tolerate particular environments. Escherichia coli (E. coli) showed a higher median concentration (2,160 colonies per gram of saturated sediment) in the 0.125 to 0.5-millimeter size range of natural sediments than in other ranges, and enterococcus bacteria showed a higher median concentration (61,830 colonies per gram of saturated sediment) in the 0.062 to 0.25-millimeter size range of natural sediments than in other ranges. There were insufficient data to assess the particle-size relation to fecal coliform bacteria and (or) fecal streptococcus bacteria. Climatic conditions were shown to affect bacteria concentrations in both the water column and fluvial sediments. Drought conditions in 2002 resulted in lower overall bacteria concentrations than the more typically wet year of 2003. E. coli concentrations in fluvial sediment along the Coatesville study reach in 2002 had a median concentration of 92 colonies per gram of saturated sediment; in 2003, the median concentration had risen to 4,752 colonies per gram of saturated sediment. Symbiotic relations between bacteria and aquatic growth were likely responsible for increased bacteria concentrations observed within an impoundment area on the Coatesville study reach. This reach showed evidence of elevated aquatic growth and sharp increases in E. coli concentrations from upstream to downstream through the impoundment area in both 2002 and 2003. In 2003, E. coli concentrations within the waters column increased from 940 colonies per 100 milliliters upstream to 6,000 colonies per 100 milliliters at the dam crest. Given that these bacteria likely resulted from natural bacterial regrowth, the use of E. coli as an indicator of fecal contamination was severely impaired. Variable environmental conditions along the West Branch Brandywine Creek made the common field-chemical parameters of specific conductance, temperature, pH, and dissolved oxygen ineffective and (or) impossible to use for the determination of inputs of fecal contamination. Extreme variations in chemical gradients commonly were related to the urban/industrial signature of the watershed. For example, during base-flow sampling in 2002, specific-conductance values exceeding 1,000 microsiemens per centimeter observed in effluent from a local steel mill. This effluent raised the specific conductance within the West Branch Brandywine from just above 200 microsiemens per centimeter upstream from the outfall to just below 500 microsiemens per centimeter downstream from the outfall. These chemical gradients also, likely, had an effect on the initial colonization of bacteria, the formation of biofilms, and the persistence of certain types of bacteria along the study reach. Data collected in 2003 indicated that nutrients increased during both base-flow and stormflow conditions along the Coatesville study reach. For example, during base-flow sampling in 2003, 20 pounds of phosphorus was shown to enter the West Branch Brandywine Creek along the Coatesville study reach. The largest contributors to this base-flow nutrient load were likely two wastewater-treatment facilities adjacent to the study reach. During stormflow sampling in 2003, 480 pounds of phosphorus was shown to enter the West Branch Brandywine Creek along the Coatesville study reach. Data, along with other research, indicated the largest contributor to this stormflow nutrient load was likely remobilized sediment originating from a large dam impoundment. These elevated nutrient concentrations were considered sufficient to promote accelerated aquatic growth along the reach. Data collected in 2003 showed that wastewater constituents entered the West Branch Brandywine Creek largely from urban storm-sewer systems. Samples from the primary storm sewer for the city of Coatesville had detections for 20 of 69 wastewater constituents. These constituents included both strong and weak indicators of fecal contamination and generally indicated the storm-sewer system along the Coatesville study reach was a likely source of fecal-indicator bacteria and fecal contamination under base-flow conditions. By comparison, 5 constituents were detected in samples from the upstream end of the reach, and 10 constituents were detected in samples from the downstream end of the reach. During stormflow, numbers of detections were similar along the entire length of the study reach-five in samples from the upstream end, eight in samples from the center of the reach, and seven in samples from the downstream end of the reach. These data indicate that point sources (such as culverts and pipes, septic systems, and wastewater-treatment facilities) are not likely the origin of bacteria contamination during stormflow. The bacteria concentrations observed during stormflow events probably result from remobilized sessile bacteria stored within fluvial sediments. In this case, these bacteria should not be considered indicators of current fecal contamination. Impervious surfaces were found to increase bacteria concentrations along the West Branch Brandywine Creek because contaminated runoff from impervious areas generally flows into, and is concentrated within, the confines of the local storm-sewer system. During 2002, storm-sewer outfalls draining impervious areas were associated with all major locations of elevated bacterial concentrations (greater than 1,200 colonies per gram of saturated sediment) in fluvial sediments. During 2003, wetter conditions and overall bacteria concentrations higher than in 2002 resulted in point sources of bacterial contamination becoming less pronounced; however, the storm-sewer system, draining adjacent impervious areas, was still observed to be the primary source of bacteria along the reach. Where stormwater and (or) other runoff from these areas was allowed to infiltrate and (or) flow through wetland and riparian buffers, bacteria concentrations were not observed to be elevated above background levels commonly observed throughout similar areas of the same reach. Two run-of-the-river dams along the Coatesville study reach were evaluated for their effects on observed bacterial concentrations. These dams were shown to have greater or lesser effects on bacterial concentrations depending on the size of the structure and the capacity of the structure to impede flows. The smaller upstream dam had an approximate height of 3 feet and showed little observed effect on measured turbidity values; these data indicated that the dam did not effectively impede the flow of water or sediment within the West Branch Brandywine Creek. Consequently, this small dam did not show any observed effect on bacterial concentrations either upstream or downstream of the structure. The larger dam, near the middle of the reach, had an approximate height of 20 feet and showed greater effects on both turbidity and bacteria concentrations. The capacity of the larger dam to impede flows, combined with nutrients entering the reach, resulted in increased biologic activity throughout the impoundment area. Within this larger impoundment, enterococcus bacteria populations were observed to decrease sharply and E. coli bacteria populations were observed to increase sharply as flow approached the dam crest. All bacteria levels were then observed to drop to background levels, in both the water column and fluvial sediment, immediately downstream from the dam crest. Additional study is required to determine the cause for this rapid die off. Turbidity was assessed as a potential surrogate for E. coli bacteria. Regression analysis indicated higher turbidity levels usually can indicate higher concentrations of bacteria (R2 = 0.67), but the relation was too sporadic on the West Branch Brandywine Creek to use turbidity as a surrogate for estimated bacteria concentrations. Evaluation of data from individual base-flow and stormflow events resulted in variable and generally poor statistical relations between E. coli bacteria and turbidity (R2 values ranged from 0.02 to 0.94). Sandbag samplers were used in 2003 to determine their suitability for the assessment of fecal contamination. Sandbag samplers rely on the ability of bacteria to attach to surfaces and use the larger sessile bacteria populations instead of the more commonly used planktonic bacteria populations. E. coli bacteria concentrations observed in the sandbag samplers, after 1 week in place, were similar to those found within natural sediments collected concurrently. Enterococcus bacteria concentrations within the same sandbag samplers were not similar, and were generally lower, than those observed within the natural sediments. This discrepancy was likely because sand within the samplers was sieved to a size that was likely too coarse for enterococcus bacteria to persist. Optical-brightener samplers were installed along with each sandbag sampler. Optical brighteners are additives used in common household detergents; therefore, detection of optical brighteners, along with elevated fecal-indicator bacteria concentrations, strongly indicates a link to humans. Positive results for optical brighteners were detected only at the outfalls of two sewage-treatment facilities; because of treatment of the effluent from these facilities, these samples did not have elevated bacteria concentrations. The lack of additional positive results was largely because this method is not sensitive to low concentrations of optical brighteners.

Explore related subjects

90° N90° S · 180° W ← longitude → 180° E
Source-reported bounding extent: 39.9592° to 40.0156° latitude; -75.8311° to -75.7978° longitude. This indicates report coverage, not an exact sampling location. View area on OpenStreetMap.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Peter J. Cinotto. 2005. Occurrence of fecal-indicator bacteria and protocols for identification of fecal-contamination sources in selected reaches of the West Branch Brandywine Creek, Chester County, Pennsylvania. https://doi.org/10.3133/sir20055039

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

Baseline water-quality inventory and summary for the Paterson Great Falls National Historical Park, New Jersey

The Paterson Great Falls National Historical Park (PAGR), established in 2011 in the City of Paterson, New Jersey, contains many cultural, historical, and natural resources. Because of the PAGR’s young age and limited resources, a long record of natural resource data is not available for use to guide future park management and planning decisions. A detailed natural resource inventory was identified as an immediate need in the “Foundation Document—Paterson Great Falls National Historical Park,” given the history of extensive industrial activity throughout the PAGR and the Passaic River Basin. The U.S. Geological Survey, in cooperation with the National Park Service and the Urban Waters Federal Partnership for the Lower Passaic River, inventoried water-quality monitoring efforts and compiled historical water-quality data from secondary data sources to define baseline conditions in the PAGR and the surrounding study area. This report documents the methods used to harmonize water-quality data aggregated from multiple sources for the PAGR study area. Procedures implemented during data harmonization include compiling data from multiple sources, assessing the dataset for completeness, addressing metadata concerns, and creating a consistent and quality-assured dataset for future analysis. The harmonized dataset contains 14 aggregated surface-water sites, 1,103 individual sampling days, and 32,000 water-quality records throughout the period of record defined for this study (1952–2021). Summary statistics and comparison to water-quality criteria are provided for focus parameters that can support PAGR management, including field properties, suspended material, total dissolved solids, specific conductance, chloride, sulfate, Escherichia coli, nutrients, contaminants of concern related to fish consumption advisories, and litter and floatable debris. A spatial data gap was identified for the recreational area near the base of the Great Falls and immediately downstream from a known combined sewer overflow discharge location. Analytic data gaps were identified for continuous streamflow and water-quality parameters, floatable debris characterization, and harmful algal blooms identification. Continuous collection of contaminants of concern was identified as a temporal data gap, as these parameters were not consistently collected within the study area. The water-quality data synthesis and summary presented in this report can assist PAGR staff in understanding the complex baseline water resources within the study area and can serve as a baseline to design future water-quality monitoring efforts and evaluate changes in water quality over time. The harmonized dataset, as well as future New Jersey Department of Environmental Protection and New Jersey Harbor Discharge Group monitoring data and assessments, can also be used to examine the status and trends in surface-water quality, support compliance with the Clean Water Act (33 U.S.C. 1251 et seq.), and further investigate changes to park water resources that can affect ecological and human health.

New Jersey↗

Slip tendency and dilation tendency of Quaternary faults in the Great Basin region, Arizona, California, Idaho, Nevada, Oregon, Utah, and Wyoming

This report presents the results of slip tendency and dilation tendency analysis of Quaternary faults in the Great Basin region, in the states of Arizona, California, Idaho, Nevada, Oregon, Utah, and Wyoming. This effort was undertaken as part of two studies: the U.S. Department of Energy Geothermal Technologies Office-funded Innovative Geothermal Exploration through Novel Investigations of Undiscovered Systems (INGENIOUS) project, which is a multidisciplinary, multi-institution effort to develop new methodologies and best practices to accelerate the discovery of new, commercially viable hydrothermal resources; and the U.S. Geological Survey Geothermal Resources Investigations Project. The goal of this work is to identify faults and fault segments that are appropriately oriented to be stress-loaded for slip or to dilate under the ambient stress conditions. Both conditions may make such faults more likely to host permeability and fluid flow relative to other faults in the region. Slip tendency and dilation tendency were calculated for all fault segments in the study area from the U.S. Geological Survey Quaternary Fault and Fold Database. Results demonstrate that faults with high slip tendency and dilation tendency are common in the Great Basin region. The areas containing many high slip tendency and dilation tendency fault segments are associated with high strain rates. These areas also host a relatively high proportion of the known hydrothermal systems. This indicates that faults with high slip tendency and dilation tendency in areas with high strain-rate are potentially most prospective for hosting hydrothermal systems. The database published in coordination with this report contains the slip tendency and dilation tendency results data, including the fault geometry and stress data used to calculate these quantities, for both the Great Basin study area and the smaller INGENIOUS study area.

Arizona, California, Idaho, Nevada, Oregon, Utah, ↗

A spatial analysis of the groundwater emergence flood hazard in Long Island, New York, and coastal areas surrounding Long Island Sound in New York, Connecticut, and Rhode Island

Long Island, New York, and nearby coastal areas surrounding Long Island Sound are densely populated and, like other coastal areas, are susceptible to flooding from several potential sources, including stormwater from precipitation events, tidal flooding and storm surge, and groundwater emergence flooding. Groundwater emergence fooding refers to the intersection of a rising water table with land surface or critical infrastructure. Many studies of flood drivers either neglect or only briefly discuss how shallow groundwater conditions may contribute to or exacerbate flood conditions. As a part of a comprehensive study of compound flood hazards in the coastal areas of Long Island and Long Island Sound, a spatial analysis was completed by the U.S. Geological Survey, in cooperation with the Environmental Protection Agency’s Long Island Sound Partnership, formerly called the Long Island Sound Study, using available regional datasets to characterize the potential hazard for groundwater emergence flooding. The approximately 3,100 square mile study area was subdivided into 11,407 grid cells that were 900 meters by 900 meters (approximately 3,000 feet by 3,000 feet), for the purpose of integrating the spatial datasets to calculate and map the groundwater emergence flood hazard. The depth to the water table, hydrologic soil groups, and National Land Cover Database were harmonized to the common grid. A groundwater emergence flood hazard score was calculated for each grid cell for current average conditions following a set of rules accounting for the depth to the water table and the percentage of area within each cell with slow infiltrating soils. A scenario with a higher sea-level position was also calculated for the Long Island part of the study area. The calculated groundwater emergence flood hazard score was reviewed in conjunction with the National Land Cover Database to identify developed areas and associated infrastructure that may be at risk of potential groundwater emergence flooding. Study results indicate that the groundwater emergence flood hazard is highest in coastal areas and near surface water where the water table is close to ground surface. Inland areas away from surface waterbodies are not likely to be exposed to groundwater emergence flooding. For Long Island, in the scenario with higher sea-level position, a greater groundwater emergence flood hazard is calculated for some locations closer to the coast and where land is submerged. Away from the coast and surface-water drainage, the groundwater emergence flood hazard is similar between the current average sea-level condition and the higher sea-level position scenario.

Connecticut, New York, Rhode Island↗