Abstract

Water samples were collected from 20 production wells and 13 private residential wells throughout the upper Susquehanna River Basin (upstream from the Pennsylvania border) during the fall of 2004 and the spring of 2005 and analyzed to describe the chemical quality of ground water in the upper basin. Wells were selected to represent areas of greatest ground-water use and highest vulnerability to contamination, and to provide a representative sampling from the entire (4,516 square-mile) upper basin. Samples were analyzed for physical properties, nutrients, inorganic constituents, metals, radionuclides, pesticides, volatile organic compounds, and bacteria. The cations that were detected in the highest concentrations were calcium, magnesium, and sodium; the anions that were detected in the greatest concentrations were bicarbonate, chloride, and sulfate. The predominant nutrient was nitrate, the concentrations of which were greater in samples from sand and gravel aquifers than in samples from bedrock. The metals barium, boron, cobalt, copper, and nickel were detected in every sample; the metals with the highest concentrations were barium, boron, iron, manganese, strontium, and lithium. The pesticide compounds detected most frequently were atrazine, deethylatrazine, alachlor ESA, and two degradation products of metolachlor (metolachlor ESA and metolachlor OA); the compounds detected in highest concentration were metolachlor ESA and OA. Volatile organic compounds were detected in 11 samples, and concentrations of 3 of these compounds exceeded 1 microgram per liter (?g/L). Methyl tert-butyl ether (MTBE), a gasollline additive, was not detected in any sample. Several analytes were found in concentrations that exceeded Federal and New York State water-quality standards, which are typically identical. Chloride concentrations exceeded the U.S. Environmental Protection Agency (USEPA) Secondary Maximum Contaminant Level (SMCL) of 250 milligrams per liter (mg/L) in two samples, and sulfate concentrations exceeded the SMCL of 250 mg/L in one sample. Sodium concentrations exceeded the USEPA Drinking Water Advisory of 60 mg/L in six samples. Nitrate concentrations exceeded the USEPA Maximum Contaminant Level (MCL) of 10 mg/L in one sample and approached this limit (at 9.84 mg/L) in another sample. Barium concentrations exceeded the MCL of 2,000 ?g/L in one sample. Iron concentrations exceeded the SMCL of 300 ?g/L in five samples, and manganese concentrations exceeded the SMCL of 50 ?g/L in 14 samples. Arsenic was detected in seven samples, and the MCL for arsenic (10 ?g/L) was exceeded in two samples. Radon-222 exceeded the proposed MCL of 300 picocuries per liter in 24 samples. Any detection of total coliform or fecal coliform bacteria is considered a violation of New York State health regulations; in this study, total coliform was detected in six samples and fecal coliform was detected in one sample, but Escherichia coli (E. coli) was not detected in any sample.

Explore related subjects

90° N90° S · 180° W ← longitude → 180° E
Source-reported bounding extent: 41.75° to 43.25° latitude; -77° to -74.25° longitude. This indicates report coverage, not an exact sampling location. View area on OpenStreetMap.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Kari K. Hetcher-Aguila, David A.V. Eckhardt. 2006. Ground-Water Quality in the Upper Susquehanna River Basin, New York, 2004-05. https://doi.org/10.3133/ofr20061161

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

ECCOE Landsat quarterly calibration and validation report—Quarter 2, 2026

Executive Summary The U.S. Geological Survey Earth Resources Observation and Science Calibration and Validation (Cal/Val) Center of Excellence (ECCOE) focuses on improving the accuracy, precision, calibration, and product quality of remote-sensing data, leveraging years of multiscale optical system geometric and radiometric calibration and characterization experience. The ECCOE Landsat Cal/Val Team continually monitors the geometric and radiometric performance of active Landsat missions and makes calibration adjustments, as needed, to maintain data quality at the highest level. This report provides observed geometric and radiometric analysis results for Landsats 8 and 9 for quarter 2 (April–June), 2026. All data used to compile the Cal/Val analysis results presented in this report are freely available from the U.S. Geological Survey EarthExplorer website: https://earthexplorer.usgs.gov.

Open-File Report↗

ECCOE Landsat quarterly calibration and validation report—Quarter 1, 2026

Executive Summary The U.S. Geological Survey Earth Resources Observation and Science Calibration and Validation (Cal/Val) Center of Excellence (ECCOE) focuses on improving the accuracy, precision, calibration, and product quality of remote-sensing data, leveraging years of multiscale optical system geometric and radiometric calibration and characterization experience. The ECCOE Landsat Cal/Val Team continually monitors the geometric and radiometric performance of active Landsat missions and makes calibration adjustments, as needed, to maintain data quality at the highest level. This report provides observed geometric and radiometric analysis results for Landsats 8 and 9 for quarter 1 (January–March) of 2026. All data used to compile the Cal/Val analysis results presented in this report are freely available from the U.S. Geological Survey EarthExplorer website: https://earthexplorer.usgs.gov . One specific activity that the ECCOE Landsat Cal/Val Team closely monitored was a Landsat 8 Thermal Infrared Sensor encoder alerts anomaly. On March 18, 2026, the Thermal Infrared Sensor instrument’s mechanism control electronics board reset, driving several parameters to default power-on values. Subsequent telemetry and analysis determined that no persistent hardware misconfiguration was present and no radiometric or geometric degradation was observed.

Open-File Report↗

Floods of June 20–July 6, 2024, in the Big Sioux River, Rock River, Little Sioux River, Ocheyedan River, and Floyd River Basins, northwestern Iowa

Major flooding occurred on June 20–July 6, 2024, in northwestern Iowa affecting the Big Sioux, Rock, Little Sioux, Ocheyedan, and Floyd River Basins. Heavy rain fell in northwestern Iowa, southwestern Minnesota, and southeastern South Dakota on June 20–22, 2024. Parts of northwestern Iowa recorded 2–6 inches of rainfall and localized amounts exceeding 12 inches. A maximum peak-of-record streamflow of 175,000 cubic feet per second at the U.S. Geological Survey streamgage Big Sioux River at Akron, Iowa (06485500), was recorded on June 22, 2024, and had an annual exceedance probability range of 0.2–0.49 percent. High-water marks were measured at four locations along the Big Sioux River between U.S. Interstate 29 at Sioux City, Iowa, upstream to Iowa Highway 10 north of Hawarden, Iowa, a distance of 75.7 river miles. A maximum peak-of-record streamflow of 157,000 cubic feet per second at the U.S. Geological Survey streamgage Rock River near Rock Valley, Iowa (06483500), was recorded on June 22, 2024, and had an annual exceedance probability of less than 0.2 percent. High-water marks were measured at eight locations along the Rock River between County Road B30 east of Hudson, South Dakota, upstream to Iowa Highway 9 at Rock Rapids, Iowa, a distance of 39.3 river miles. A maximum peak-of-record streamflow of 63,000 cubic feet per second at the U.S. Geological Survey streamgage Little Sioux River at Correctionville, Iowa (06606600), was recorded on June 24, 2024, and had an annual exceedance probability range of 0.2–0.49 percent. High-water marks were measured at 11 locations along the Little Sioux River between Iowa Highway 31 west of Correctionville, Iowa, upstream to U.S. Highway 18 north of Spencer, Iowa, a distance of 134.8 river miles. A maximum streamflow of 24,500 cubic feet per second at the U.S. Geological Survey streamgage Ocheyedan River near Spencer, Iowa (06605000), was recorded on June 22, 2024, and had an annual exceedance probability range of 0.2–0.49 percent. High-water marks were measured at three locations along the Ocheyedan River between County Road M38 west of Spencer, Iowa, upstream to U.S. Highway 18 west of Everly, Iowa, a distance of 12.8 river miles. A maximum streamflow of 41,000 cubic feet per second at the U.S. Geological Survey streamgage Floyd River at Alton, Iowa (06600100), was recorded on June 22, 2024, and had an annual exceedance probability range of 1–1.99 percent. High-water marks were measured at six locations along the Floyd River between Iowa Highway 3 at Le Mars, Iowa, upstream to Iowa Highway 10 at Alton, Iowa, a distance of 27.5 river miles. The high-water marks were used to develop flood profiles for the Big Sioux, Rock, Little Sioux, Ocheyedan, and Floyd Rivers.

Iowa, Minnesota, South Dakota↗