The use of Schlumberger and equatorial soundings in groundwater investigations near El Paso, Texas

Abstract

Electrical soundings using the symmetric AMNB Schlumberger and the bipole-dipole equatorial arrays were made along two profiles near El Paso, Texas, in support of a groundwater exploration program which included seismic refraction and gravity surveys. Electrode spacings (AB/2 or R) reaching 12,000 ft allowed exploration to depths of about 7000 ft. Geoelectrical information on the subsurface materials was augmented by sounding with the bilateral equatorial configuration and by transforming Schlumberger curves into dipole-polar sounding curves with formulas developed by Al'pin and by Tsekov. The bilateral equatorial sounding curves were found useful for detecting the direction of dip of highly resistive bedrocks whereas transformed sounding curves were used to evaluate the average longitudinal resistivity, and hence the depth, to the "electric basement." A few of the Schlumberger sounding curves were either clearly or subtly distorted by nonhorizontal geologic structures. The interpretation of these sounding curves illustrates the requirement for careful analysis in processing electrical prospecting data obtained over complex geologic conditions. The interpretation of a combined Schlumberger-equatorial sounding curve, which did not agree with the preliminary interpretation of seismic refraction data, was confirmed to be correct by data from a test well drilled to a depth of 4363 ft. The application of electrical sounding data in the El Paso area furnished valuable information on the depth to fresh-water-saltwater interfaces and on the depth to highly resistive impervious bedrocks.

Explore related subjects

90° N90° S · 180° W ← longitude → 180° E
Source-reported bounding extent: 31.675589707562505° to 32.00225320314841° latitude; -106.06063842773438° to -105.029296875° longitude. This indicates report coverage, not an exact sampling location. View area on OpenStreetMap.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Adel A. R. Zohdy. 1969. The use of Schlumberger and equatorial soundings in groundwater investigations near El Paso, Texas. https://doi.org/10.1190/1.1440042

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

Cooperative joint inversion of magnetotelluric and microseismic data for imaging the Geysers geothermal field, California, USA

The Geysers geothermal field located in northern California, USA, is the world’s largest electricity-generating geothermal facility. To delineate the spatio-temporal distribution of reservoir steam and recharge water, we have collected microseismic and magnetotelluric (MT) data using a dense array of stations in 2021. The microseismic and MT data have been inverted together using a 3D cooperative joint inversion workflow. The joint inversion exploits a cross-gradient structural constraint because electrical conductivity structures observed in the geothermal field are strongly correlated with

California

Inversion of induced polarization-affected towed-transient electromagnetic data in a lateritic regolith geology: A case study from western Tanzania

For several decades, induced polarization (IP) effects on transient electromagnetic (TEM) responses have been observed. These effects can manifest as late-time negative transients or as rapidly decaying curves and are usually associated with highly polarizable bodies. If neglected, IP effects can lead to erroneous resistivity models. Recent work allows IP effects to be incorporated into the inversion of TEM data on a more routine basis. In a recent field survey in western Tanzania, strongly IP-affected TEM signals are observed using a towed-transient electromagnetic (tTEM) system. The survey have been carried out to locate drinking water resources in a weathered regolith setting. In these settings, an inversion of tTEM data using a resistivity-only forward model (i.e., IP neglected) cannot fit the data and severely limits the value of the TEM data for hydrogeologic interpretation. To account for IP effects, we have applied a modified version of the Cole-Cole model called the maximum phase angle (MPA) model to invert IP-affected tTEM data. The MPA model incorporates four inversion model parameters: resistivity ( ⁠ ρ "> ρ ), MPA ( ⁠ ϕ max "> ϕ max ⁠ ), relaxation time ( ⁠ τ "> τ ), and frequency exponent ( ⁠ c "> c ). The MPA model fits the data well and improves the reliability of the resistivity model. In much of the surveyed region, the inverted models using MPA display a three-layer system consisting of an upper resistive laterite layer of varying thickness and an intermediate polarizable conductive unit overlying more resistive weathered basement rocks. The conductive polarizable layer is interpreted as a chemically weathered saprolite separating the surficial and deeper aquifers. Overall, tTEM inversion results provide a local understanding of groundwater systems, especially in such regions with very limited subsurface knowledge.

Kaguruka, Kitagata

Evidence-based guidelines for protective actions and earthquake early warning systems

Earthquake early warning systems (EEW) are becoming increasingly available or in development throughout the world. With public alerting in Mexico, Japan, Taiwan, and parts of the United States, it is important to provide evidence-based recommendations for protective action so people can protect themselves when they receive an alert. Best-practice warning communication research suggests that providing a protective action will increase the efficacy of the message. However, given the diversity of earthquakes and building types, as well as social and cultural contexts where these systems exist, the question is: what is the best protective action to recommend? The answer lies in maximizing life-saving protective actions during an earthquake event requires both contextually relevant messaging and widespread public education about appropriate protective actions under a range of conditions. By researching previous earthquake injury literature, examining current best practices and public education campaigns, key protective actions may be determined and used to increase the life-saving potential of earthquake early warning systems.

Geophysics