Blind identification of the Millikan Library from earthquake data considering soil–structure interaction

Abstract

The Robert A. Millikan Library is a reinforced concrete building with a basement level and nine stories above the ground. Located on the campus of California Institute of Technology (Caltech) in Pasadena California, it is among the most densely instrumented buildings in the U.S. From the early dates of its construction, it has been the subject of many investigations, especially regarding soil–structure interaction effects. It is well accepted that the structure is significantly interacting with the surrounding soil, which implies that the true foundation input motions cannot be directly recorded during earthquakes because of inertial effects. Based on this limitation, input–output modal identification methods are not applicable to this soil–structure system. On the other hand, conventional output-only methods are typically based on the unknown input signals to be stationary whitenoise, which is not the case for earthquake excitations. Through the use of recently developed blind identification (i.e. output-only) methods, it has become possible to extract such information from only the response signals because of earthquake excitations. In the present study, we employ such a blind identification method to extract the modal properties of the Millikan Library. We present some modes that have not been identified from force vibration tests in several studies to date. Then, to quantify the contribution of soil–structure interaction effects, we first create a detailed Finite Element (FE) model using available information about the superstructure; and subsequently update the soil–foundation system's dynamic stiffnesses at each mode such that the modal properties of the entire soil–structure system agree well with those obtained via output-only modal identification.

Explore related subjects

90° N90° S · 180° W ← longitude → 180° E
Source-reported bounding extent: 34.13136240467381° to 34.14203648796777° latitude; -118.12946319580077° to -118.12130928039551° longitude. This indicates report coverage, not an exact sampling location. View area on OpenStreetMap.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S. F. Ghahari, F. Abazarsa, O. Avci, Mehmet Çelebi, E. Taciroglu. 2015-09-29. Blind identification of the Millikan Library from earthquake data considering soil–structure interaction. https://doi.org/10.1002/stc.1803

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

Quantifying modeling uncertainty in simplified beam models for building response prediction

The use of simple models for response prediction of building structures is preferred in earthquake engineering for risk evaluations at regional scales, as they make computational studies more feasible. The primary impediment in their gainful use presently is the lack of viable methods for quantifying (and reducing upon) the modeling errors/uncertainties they bear. This study presents a Bayesian calibration method wherein the modeling error is embedded into the parameters of the model. The method is specifically described for coupled shear-flexural beam models here, but it can be applied to any parametric surrogate model. The major benefit the method offers is the ability to consider the modeling uncertainty in the forward prediction of any degree-of-freedom or composite response regardless of the data used in calibration. The method is extensively verified using two synthetic examples. In the first example, the beam model is calibrated to represent a similar beam model but with enforced modeling errors. In the second example, the beam model is used to represent the detailed finite element model of a 52-story building. Both examples show the capability of the proposed solution to provide realistic uncertainty estimation around the mean prediction.

Structural Control and Health Monitoring