Geology Reports⌕ Search

Geology topics

Tyler B. Coplen

Publications and source records attributed to Tyler B. Coplen.

At least 37 records · Page 2Linked to original sources

Variation of lead isotopic composition and atomic weight in terrestrial materials (IUPAC Technical Report)

The isotopic composition and atomic weight of lead are variable in terrestrial materials because its three heaviest stable isotopes are stable end-products of the radioactive decay of uranium ( 238 U to 206 Pb; 235 U to 207 Pb) and thorium ( 232 Th to 208 Pb). The lightest stable isotope, 204 Pb, is primordial. These variations in isotope ratios and atomic weights provide useful information in many areas of science, including geochronology, archaeology, environmental studies, and forensic science. While elemental lead can serve as an abundant and homogeneous isotopic reference, deviations from the isotope ratios in other lead occurrences limit the accuracy with which a standard atomic weight can be given for lead. In a comprehensive review of several hundred publications and analyses of more than 8000 samples, published isotope data indicate that the lowest reported lead atomic weight of a normal terrestrial materials is 206.1462 ± 0.0028 ( k = 2), determined for a growth of the phosphate mineral monazite around a garnet relic from an Archean high-grade metamorphic terrain in north-western Scotland, which contains mostly 206 Pb and almost no 204 Pb. The highest published lead atomic weight is 207.9351 ± 0.0005 ( k = 2) for monazite from a micro-inclusion in a garnet relic, also from a high-grade metamorphic terrain in north-western Scotland, which contains almost pure radiogenic 208 Pb. When expressed as an interval, the lead atomic weight is [206.14, 207.94]. It is proposed that a value of 207.2 be adopted for the single lead atomic-weight value for education, commerce, and industry, corresponding to previously published conventional atomic-weight values.

Pure and Applied Chemistry↗

Food matrix reference materials for hydrogen, carbon, nitrogen, oxygen, and sulfur stable isotope-ratio measurements: Collagens, flours, honeys, and vegetable oils

An international project developed, quality-tested, and measured isotope–delta values of 10 new food matrix reference materials (RMs) for hydrogen, carbon, nitrogen, oxygen, and sulfur stable isotope-ratio measurements to support food authenticity testing and food provenance verification. These new RMs, USGS82 to USGS91, will enable users to normalize measurements of samples to isotope–delta scales. The RMs include (i) two honeys from Canada and tropical Vietnam, (ii) two flours from C3 (rice) and C4 (millet) plants, (iii) four vegetable oils from C3 (olive, peanut) and C4 (corn) plants, and (iv) two collagen powders from marine fish and terrestrial mammal origins. An errors-in-variables regression model included the uncertainty associated with the measured and assigned values of the RMs, and it was applied centrally to normalize results and obtain consensus values and measurement uncertainties. Utilization of these new RMs should facilitate mutual compatibility of stable isotope data if accepted normalization procedures are applied and documented.

Journal of Agricultural and Food Chemistry↗

Dual clumped isotope thermometry resolves kinetic biases in carbonate formation temperatures

Surface temperature is a fundamental parameter of Earth’s climate. Its evolution through time is commonly reconstructed using the oxygen isotope and the clumped isotope compositions of carbonate archives. However, reaction kinetics involved in the precipitation of carbonates can introduce inaccuracies in the derived temperatures. Here, we show that dual clumped isotope analyses, i.e., simultaneous Δ 47 and Δ 48 measurements on the single carbonate phase, can identify the origin and quantify the extent of these kinetic biases. Our results verify theoretical predictions and evidence that the isotopic disequilibrium commonly observed in speleothems and scleractinian coral skeletons is inherited from the dissolved inorganic carbon pool of their parent solutions. Further, we show that dual clumped isotope thermometry can achieve reliable palaeotemperature reconstructions, devoid of kinetic bias. Analysis of a belemnite rostrum implies that it precipitated near isotopic equilibrium and confirms the warmer-than-present temperatures during the Early Cretaceous at southern high latitudes.

Nature Communications↗

Calibration of carbonate-water triple oxygen isotope fractionation: Seeing through diagenesis in ancient carbonates

High precision triple oxygen isotope measurements of carbonates can better constrain temperatures and oxygen isotope compositions of seawater through geologic time than 18 O/ 16 O measurements alone, but lack of a definitive calibration has hindered progress. In this study, we fluorinated both carbonate and water samples to measure quantitatively the triple oxygen isotope composition of each phase. We compared the oxygen isotope fractionation between carbonate and water for different carbonate materials: calcite synthesized with and without carbonic anhydrase, abiogenic calcite from Devils Hole, and extant biogenic calcite and aragonite of marine origin. We found similar 1000 lnα 18 O cc-wt values for all materials and combined the results with the high temperature experimental data of O'Neil et al. (1969) , resulting in the following fractionation equation ( T in Kelvins) 1000 ln α 18 O cc - w t = 2.84 ( ± 0.02 ) × 10 6 T 2 - 2.96 ( ± 0.19 ) "> 1000lnα18Occ-wt=2.84(±0.02)×106T2-2.96(±0.19) . The calcite triple oxygen isotope values yielded a θ - T relationship of θ cc-wt = –1.39(±0.01)/ T + 0.5305 whereas the aragonite triple oxygen isotope values yielded a θ - T relationship of θ ara-wt = –1.53(±0.02)/ T + 0.5305. The calcite-water triple oxygen isotope equilibrium fractionation equation for natural samples is Δ 17 ′ O cc - Δ 17 ′ O wt = 2.84 ( ± 0.02 ) × 10 6 T 2 - 2.96 ( ± 0.19 ) - 1.39 ( ± 0.01 ) T + 0.5305 - λ "> Δ17′Occ-Δ17′Owt=2.84(±0.02)×106T2-2.96(±0.19)-1.39(±0.01)T+0.5305-λ . The combined 1000 lnα 18 O and 1000 lnα 17 O relationships can be used to assess equilibrium in ancient samples and to evaluate potential secular changes in the δ 18 O value of seawater. Most of the Phanerozoic samples analyzed in this study, which were determined to be pristine in previous studies, have undergone some level of diagenesis. Two samples appear to preserve their original oxygen isotope compositions and suggest a cool ocean with a δ 18 O value similar to the modern ocean. Using a fluid-rock interaction model, we can “see through” the diagenetic process and estimate the triple oxygen isotope composition of the carbonate prior to alteration. In doing so, we show that for the time intervals and sample locations measured in this study, Phanerozoic oceans had a comparable range of oxygen isotope compositions and temperatures as modern seawater.

Geochemica et Cosmochimica Acta↗

Most Earth-surface calcites precipitate out of isotopic equilibrium

Oxygen-isotope thermometry played a critical role in the rise of modern geochemistry and remains extensively used in (bio-)geoscience. Its theoretical foundations rest on the assumption that 18 O/ 16 O partitioning among water and carbonate minerals primarily reflects thermodynamic equilibrium. However, after decades of research, there is no consensus on the true equilibrium 18 O/ 16 O fractionation between calcite and water ( 18 α cc/w ). Here, we constrain the equilibrium relations linking temperature, 18 α cc/w , and clumped isotopes ( Δ 47 ) based on the composition of extremely slow-growing calcites from Devils Hole and Laghetto Basso (Corchia Cave). Equilibrium 18 α cc/w values are systematically ~1.5‰ greater than those in biogenic and synthetic calcite traditionally considered to approach oxygen-isotope equilibrium. We further demonstrate that subtle disequilibria also affect Δ 47 in biogenic calcite. These observations provide evidence that most Earth-surface calcites fail to achieve isotopic equilibrium, highlighting the need to improve our quantitative understanding of non-equilibrium isotope fractionation effects instead of relying on phenomenological calibrations.

Nature Communications↗

Isotopes matter

Two years ago, the King’s Centre for Visualization in Science (KCVS) at The King’s University, Edmonton released a new digital interactive version of the IUPAC Periodic Table of the Elements and Isotopes with accompanying educational resources at an International Conference on Chemistry Education. It can be found at www.isotopesmatter.com. The effort was part of an IUPAC project . The science behind this new table was developed by Inorganic Chemistry Division scientists working for over a decade on an earlier IUPAC project . These projects were joint efforts between the IUPAC Committee on Chemistry Education (CCE) and the Inorganic Chemistry Division.

Chemistry International↗

Investigation of recent decadal-scale cyclical fluctuations in salinity in the lower Colorado river

Beginning in the late 1970s, 10- to 15-year cyclical oscillations in salinity were observed at lower Colorado River monitoring sites, moving upstream from the international border with Mexico, above Imperial Dam, below Hoover Dam, and at Lees Ferry. The cause of these cyclical trends in salinity was unknown. These salinity cycles complicate the U.S. Bureau of Reclamation's (Reclamation) responsibility for managing salinity in the river for delivery of water to Mexico to meet treaty obligations. This study develops a conceptual model of the salinity cycles from time-series water quality, streamflow, and precipitation data in both the lower and upper Colorado River Basins in order to provide Reclamation the ability to understand, anticipate, and manage future salinity cycles in the lower river. Compared with the Lees Ferry record, both maximum and minimum salinity levels increase downstream by about 25% at Hoover Dam, by about 49% at Imperial Dam, and by about 69% at the northern international boundary with Mexico. In the upper basin, cyclical salinity trends are evident at the outflow of three major tributaries, where salinity is also noted to be inversely related to streamflow. Time series trends in precipitation within the catchments of the three upper basin tributaries indicate cyclical periods with above normal precipitation and periods with below normal precipitation. Periods of greater than normal precipitation in the contributing areas correspond with declines in salinity at the catchment monitoring sites and periods of less than normal precipitation correspond with rising salinity at the sites. Based on the conceptual model developed in this investigation, a multiple linear regression model was developed using a stepwise variable selection procedure to simulate salinity in Lake Powell inflow. Important variables in the explanation of salinity entering Lake Powell include flow from the three upper basin tributaries, seasonality, and mean precipitation in the upper basin, among others. The root mean square error of prediction for the MLR model was 31.48 mg/L (5.7%).

Arizona, Colorado, Nevada, New Mexico, Utah, Wyomi↗

IUPAC Periodic Table of the Elements and Isotopes (IPTEI) for the education community (IUPAC Technical Report)

The IUPAC (International Union of Pure and Applied Chemistry) Periodic Table of the Elements and Isotopes (IPTEI) was created to familiarize students, teachers, and non-professionals with the existence and importance of isotopes of the chemical elements. The IPTEI is modeled on the familiar Periodic Table of the Chemical Elements. The IPTEI is intended to hang on the walls of chemistry laboratories and classrooms. Each cell of the IPTEI provides the chemical name, symbol, atomic number, and standard atomic weight of an element. Color-coded pie charts in each element cell display the stable isotopes and the relatively long lived radioactive isotopes having characteristic terrestrial isotopic compositions that determine the standard atomic weight of each element. The background color scheme of cells categorizes the 118 elements into four groups: (1) white indicates the element has no standard atomic weight, (2) blue indicates the element has only one isotope that is used to determine its standard atomic weight, which is given as a single value with an uncertainty, (3) yellow indicates the element has two or more isotopes that are used to determine its standard atomic weight, which is given as a single value with an uncertainty, and (4) pink indicates the element has a well-documented variation in its atomic weight, and the standard atomic weight is expressed as an interval. An element-by-element review accompanies the IPTEI and includes a chart of all known stable and radioactive isotopes for each element. Practical applications of isotopic measurements and technologies are included for the following fields: forensic science, geochronology, Earth-system sciences, environmental science, and human health sciences, including medical diagnosis and treatment.

Pure and Applied Chemistry↗

Preliminary assessment of stable nitrogen and oxygen isotopic composition of USGS51 and USGS52 nitrous oxide reference gases and perspectives on calibration needs

Rationale Despite a long history and growing interest in isotopic analyses of N 2 O, there is a lack of isotopically characterized N 2 O isotopic reference materials (standards) to enable normalization and reporting of isotope‐delta values. Here we report the isotopic characterization of two pure N 2 O gas reference materials, USGS51 and USGS52, which are now available for laboratory calibration ( https://isotopes.usgs.gov/lab/referencematerials.html ). Methods A total of 400 sealed borosilicate glass tubes of each N 2 O reference gas were prepared from a single gas filling of a high vacuum line. We demonstrated isotopic homogeneity via dual‐inlet isotope‐ratio mass spectrometry. Isotopic analyses of these reference materials were obtained from eight laboratories to evaluate interlaboratory variation and provide preliminary isotopic characterization of their δ 15 N, δ 18 O, δ 15 N α , δ 15 N β and site preference ( S P ) values. Results The isotopic homogeneity of both USGS51 and USGS52 was demonstrated by one‐sigma standard deviations associated with the determinations of their δ 15 N, δ 18 O, δ 15 N α , δ 15 N β and S P values of 0.12 mUr or better. The one‐sigma standard deviations of S P measurements of USGS51 and USGS52 reported by eight laboratories participating in the interlaboratory comparison were 1.27 and 1.78 mUr, respectively. Conclusions The agreement of isotope‐delta values obtained in the interlaboratory comparison was not sufficient to provide reliable accurate isotope measurement values for USGS51 and USGS52. We propose that provisional values for the isotopic composition of USGS51 and USGS52 determined at the Tokyo Institute of Technology can be adopted for normalizing and reporting sample data until further refinements are achieved through additional calibration efforts.

Rapid Communications in Mass Spectrometry↗

Clarification of the term “normal material” used for standard atomic weights (IUPAC Technical Report)

The standard atomic weights of the elements apply to normal materials. Since 1984, the Commission on Isotopic Abundances and Atomic Weights (Commission) has defined a normal material as: “The material is a reasonably possible source for this element or its compounds in commerce, for industry or science; the material is not itself studied for some extraordinary anomaly and its isotopic composition has not been modified significantly in a geologically brief period.” The term “a geologically brief period” in this definition is confusing, and confusion can be reduced by revising this definition to the following, which was accepted by the Commission on Isotopic Abundances and Atomic Weights at its meeting in Groningen, Netherlands in September 2017: “ Normal materials include all substances, except (1) those subjected to substantial deliberate, undisclosed, or inadvertent artificial isotopic modification, (2) extraterrestrial materials, and (3) isotopically anomalous specimens, such as natural nuclear reactor products from Oklo (Gabon) or other unique occurrences.”

Pure and Applied Chemistry↗

Seeking excellence: An evaluation of 235 international laboratories conducting water isotope analyses by isotope-ratio and laser-absorption spectrometry

Rationale Water stable isotope ratios ( δ 2 H and δ 18 O values) are widely used tracers in environmental studies; hence, accurate and precise assays are required for providing sound scientific information. We tested the analytical performance of 235 international laboratories conducting water isotope analyses using dual-inlet and continuous-flow isotope ratio mass spectrometers and laser spectrometers through a water isotope inter-comparison test. Methods Eight test water samples were distributed by the IAEA to international stable isotope laboratories. These consisted of a core set of five samples spanning the common δ -range of natural waters, and three optional samples (highly depleted, enriched, and saline). The fifth core sample contained unrevealed trace methanol to assess analyst vigilance to the impact of organic contamination on water isotopic measurements made by all instrument technologies. Results For the core and optional samples ~73 % of laboratories gave acceptable results within 0.2 ‰ and 1.5 ‰ of the reference values for δ 18 O and δ 2 H, respectively; ~27 % produced unacceptable results. Top performance for δ 18 O values was dominated by dual-inlet IRMS laboratories; top performance for δ 2 H values was led by laser spectrometer laboratories. Continuous-flow instruments yielded comparatively intermediate results. Trace methanol contamination of water resulted in extreme outlier δ -values for laser instruments, but also affected reactor-based continuous-flow IRMS systems; however, dual-inlet IRMS δ -values were unaffected. Conclusions Analysis of the laboratory results and their metadata suggested inaccurate or imprecise performance stemmed mainly from skill- and knowledge-based errors including: calculation mistakes, inappropriate or compromised laboratory calibration standards, poorly performing instrumentation, lack of vigilance to contamination, or inattention to unreasonable isotopic outcomes. To counteract common errors, we recommend that laboratories include 1–2 'known' control standards in all autoruns; laser laboratories should screen each autorun for spectral contamination; and all laboratories should evaluate whether derived d- excess values are realistic when both isotope ratios are measured. Combined, these data evaluation strategies should immediately inform the laboratory about fundamental mistakes or compromised samples.

Rapid Communications in Mass Spectrometry↗

Optimization of on-line hydrogen stable isotope ratio measurements of halogen- and sulfur-bearing organic compounds using elemental analyzer–chromium/high-temperature conversion isotope ratio mass spectrometry (EA-Cr/HTC-IRMS)

Rationale: Accurate hydrogen isotopic analysis of halogen- and sulfur-bearing organics has not been possible with traditional high-temperature conversion (HTC) because the formation of hydrogen-bearing reaction products other than molecular hydrogen (H2) is responsible for non-quantitative H2 yields and possible hydrogen isotopic fractionation. Our previously introduced, new chromium-based EA-Cr/HTC-IRMS (Elemental Analyzer–Chromium/High-Temperature Conversion Isotope Ratio Mass Spectrometry) technique focused primarily on nitrogen-bearing compounds. Several technical and analytical issues concerning halogen- and sulfur-bearing samples, however, remained unresolved and required further refinement of the reactor systems. Methods: The EA-Cr/HTC reactor was substantially modified for the conversion of halogen- and sulfur-bearing samples. The performance of the novel conversion setup for solid and liquid samples was monitored and optimized using a simultaneously operating dual-detection system of IRMS and ion trap MS. The method with several variants in the reactor, including the addition of manganese metal chips, was evaluated in three laboratories using EA-Cr/HTC-IRMS (on-line method) and compared with traditional uranium-reduction-based conversion combined with manual dual-inlet IRMS analysis (off-line method) in one laboratory. Results: The modified EA-Cr/HTC reactor setup showed an overall H2-recovery of more than 96% for all halogen- and sulfur-bearing organic compounds. All results were successfully normalized via two-point calibration with VSMOW-SLAP reference waters. Precise and accurate hydrogen isotopic analysis was achieved for a variety of organics containing F-, Cl-, Br-, I-, and S-bearing heteroelements. The robust nature of the on-line EA-Cr/HTC technique was demonstrated by a series of 196 consecutive measurements with a single reactor filling. Conclusions: The optimized EA-Cr/HTC reactor design can be implemented in existing analytical equipment using commercially available material and is universally applicable for both heteroelement-bearing and heteroelement-free organic-compound classes. The sensitivity and simplicity of the on-line EA-Cr/HTC-IRMS technique provide a much needed tool for routine hydrogen-isotope source tracing of organic contaminants in the environment. Copyright © 2016 John Wiley & Sons, Ltd.

Rapid Communications in Mass Spectrometry↗

Clarifying atomic weights: A 2016 four-figure table of standard and conventional atomic weights

To indicate that atomic weights of many elements are not constants of nature, in 2009 and 2011 the Commission on Isotopic Abundances and Atomic Weights (CIAAW) of the International Union of Pure and Applied Chemistry (IUPAC) replaced single-value standard atomic weight values with atomic weight intervals for 12 elements (hydrogen, lithium, boron, carbon, nitrogen, oxygen, magnesium, silicon, sulfur, chlorine, bromine, and thallium); for example, the standard atomic weight of nitrogen became the interval [14.00643, 14.00728]. CIAAW recognized that some users of atomic weight data only need representative values for these 12 elements, such as for trade and commerce. For this purpose, CIAAW provided conventional atomic weight values, such as 14.007 for nitrogen, and these values can serve in education when a single representative value is needed, such as for molecular weight calculations. Because atomic weight values abridged to four figures are preferred by many educational users and are no longer provided by CIAAW as of 2015, we provide a table containing both standard atomic weight values and conventional atomic weight values abridged to four figures for the chemical elements. A retrospective review of changes in four-digit atomic weights since 1961 indicates that changes in these values are due to more accurate measurements over time or to the recognition of the impact of natural isotopic fractionation in normal terrestrial materials upon atomic weight values of many elements. Use of the unit “u” (unified atomic mass unit on the carbon mass scale) with atomic weight is incorrect because the quantity atomic weight is dimensionless, and the unit “amu” (atomic mass unit on the oxygen scale) is an obsolete term: Both should be avoided.

Journal of Chemical Education↗

Devils Hole, Nevada, δ 18 O record extended to the mid-Holocene

The mid-to-late Pleistocene Devils Hole δ 18 O record has been extended from 60,000 to 4500 yr ago. The new δ 18 O time series, in conjunction with the one previously published, is shown to be a proxy of Pacific Ocean sea surface temperature (SST) off the coast of California. During marine oxygen isotope stages (MIS) 2 and 6, the Devil Hole and SST time series exhibit a steady warming that began 5000 to > 10,000 yr prior to the last and penultimate deglaciations. Several possible proximate causes for this early warming are evaluated. The magnitude of the peak δ 18 O or SST during the last interglacial (LIG) is significantly greater (1 per mill and 2 to 3°C, respectively) than the peak value of these parameters for the Holocene; in contrast, benthic δ 18 O records of ice volume show only a few tenths per mill difference in the peak value for these interglacials. Statistical analysis provides an estimate of the large shared information (variation) between the Devils Hole and Eastern Pacific SST time series from ∼ 41 to ∼ 2°N and enforces the concept of a common forcing among all of these records. The extended Devils Hole record adds to evidence of the importance of uplands bordering the eastern Pacific as a source of archives for reconstructing Pacific climate variability.

Quaternary Research↗

Isotope-abundance variations and atomic weights of selected elements: 2016 (IUPAC Technical Report)

There are 63 chemical elements that have two or more isotopes that are used to determine their standard atomic weights. The isotopic abundances and atomic weights of these elements can vary in normal materials due to physical and chemical fractionation processes (not due to radioactive decay). These variations are well known for 12 elements (hydrogen, lithium, boron, carbon, nitrogen, oxygen, magnesium, silicon, sulfur, chlorine, bromine, and thallium), and the standard atomic weight of each of these elements is given by IUPAC as an interval with lower and upper bounds. Graphical plots of selected materials and compounds of each of these elements have been published previously. Herein and at the URL http://dx.doi.org/10.5066/F7GF0RN2 , we provide isotopic abundances, isotope-delta values, and atomic weights for each of the upper and lower bounds of these materials and compounds.

Pure and Applied Chemistry↗

New biotite and muscovite isotopic reference materials, USGS57 and USGS58, for δ2H measurements–A replacement for NBS 30

The advent of continuous-flow isotope-ratio mass spectrometry (CF-IRMS) coupled with a high temperature conversion (HTC) system enabled faster, more cost effective, and more precise δ 2 H analysis of hydrogen-bearing solids. Accurate hydrogen isotopic analysis by on-line or off-line techniques requires appropriate isotopic reference materials (RMs). A strategy of two-point calibrations spanning δ 2 H range of the unknowns using two RMs is recommended. Unfortunately, the supply of the previously widely used isotopic RM, NBS 30 biotite, is exhausted. In addition, recent measurements have shown that the determination of δ 2 H values of NBS 30 biotite on the VSMOW-SLAP isotope-delta scale by on-line HTC systems with CF-IRMS may be unreliable because hydrogen in this biotite may not be converted quantitatively to molecular hydrogen. The δ 2 H VSMOW-SLAP values of NBS 30 biotite analyzed by on-line HTC systems can be as much as 21 mUr (or ‰) too positive compared to the accepted value of − 65.7 mUr, determined by only a few conventional off-line measurements. To ensure accurate and traceable on-line hydrogen isotope-ratio determinations in mineral samples, we here propose two isotopically homogeneous, hydrous mineral RMs with well-characterized isotope-ratio values, which are urgently needed. The U.S. Geological Survey (USGS) has prepared two such RMs, USGS57 biotite and USGS58 muscovite. The δ 2 H values were determined by both glassy carbon-based on-line conversion and chromium-based on-line conversion, and results were confirmed by off-line conversion. The quantitative conversion of hydrogen from the two RMs using the on-line HTC method was carefully evaluated in this study. The isotopic compositions of these new RMs with 1-σ uncertainties and mass fractions of hydrogen are: USGS57 (biotite) δ 2 H VSMOW-SLAP = − 91.5 ± 2.4 mUr ( n = 24) Mass fraction hydrogen = 0.416 ± 0.002% ( n = 4) Mass fraction water = 3.74 ± 0.02% ( n = 4) USGS58 (muscovite) δ 2 H VSMOW-SLAP = − 28.4 ± 1.6 mUr ( n = 24) Mass fraction hydrogen = 0.448 ± 0.002% ( n = 4) Mass fraction water = 4.03 ± 0.02% ( n = 4). These δ 2 H VSMOW-SLAP values encompass typical ranges for solid unknowns of crustal and mantle origin and are available to users for recommended two-point calibration.

Chemical Geology↗

Review of footnotes and annotations to the 1949–2013 tables of standard atomic weights and tables of isotopic compositions of the elements (IUPAC Technical Report)

The Commission on Isotopic Abundances and Atomic Weights uses annotations given in footnotes that are an integral part of the Tables of Standard Atomic Weights to alert users to the possibilities of quite extraordinary occurrences, as well as sources with abnormal atomic-weight values outside an otherwise acceptable range. The basic need for footnotes to the Standard Atomic Weights Table and equivalent annotations to the Table of Isotopic Compositions of the Elements arises from the necessity to provide users with information that is relevant to one or more elements, but that cannot be provided using numerical data in columns. Any desire to increase additional information conveyed by annotations to these Tables is tempered by the need to preserve a compact format and a style that can alert users, who would not be inclined to consult either the last full element-by-element review or the full text of a current Standard Atomic Weights of the Elements report. Since 1989, the footnotes of the Tables of Standard Atomic Weights and the annotations in column 5 of the Table of Isotopic Compositions of the Elements have been harmonized by use of three lowercase footnotes, “g”, “m”, and “r”, that signify geologically exceptionally specimens (“g”), modified isotopic compositions in material subjected to undisclosed or inadvertent isotopic fractionation (“m”), and the range in isotopic composition of normal terrestrial material prevents more precise atomic-weight value being given (“r”). As some elements are assigned intervals for their standard atomic-weight values (applies to 12 elements since 2009), footnotes “g” and “r” are no longer needed for these elements.

Pure and Applied Chemistry↗