Geology Reports⌕ Search

Geology topics

Hongbin Zhan

Publications and source records attributed to Hongbin Zhan.

4 recordsLinked to original sources

Update of the 2008 provisional Enhanced Geothermal Systems (EGS) assessment for the Great Basin, USA

In response to the Energy Act of 2020, the U.S. Geological Survey (USGS) is updating the Enhanced Geothermal Systems (EGS) resource assessment for the Great Basin, USA. The previous 2008 provisional assessment estimated how much electricity could be generated from EGS resources of the western United States using models of electric-grade heat, models of heat extraction over time, and estimates of how much rock might be stimulated to produce viable amounts of heat. Herein, a similar conceptual strategy is applied, using updated models of heat extraction as a function of fracture spacing and well distance. Previously used reservoir heat delivery models are updated to have a dependence on fracture and well spacing, potentially improving future estimates of EGS resources as ongoing research provides a better understanding about the success of reservoir stimulation as a function of geology and location. For a range of well distances (250-1000 m) and fracture spacings (1-50 m), heat extraction efficiency ranges from 25-62%, demonstrating the importance of accounting for the most likely results of proven viable fracturing technologies. Although fracturing is important, the biggest uncertainty by far in estimating the EGS resource for the Great Basin is estimating which geologic units at what depths can be stimulated sufficiently to produce geothermal energy economically and efficiently. Uncertainties in these factors yield estimates that range over two orders of magnitude with an upper limit of ~174 terawatts-thermal (TWth) produced for 30 years from the upper 7 km of the crust. This upper limit would require significant technological advances to access most of the electric-grade resource across the Great Basin. Assuming that 1% of this estimate will be accessible in the next few decades gives a resource estimate similar to that made in the 2008 provisional assessment. These estimated EGS heat extraction rates far exceed ( greater than 100x) the natural geothermal heat production rate, thus geothermal electricity production at these rates might not be sustainable unless heat is also recharged from other sources (e.g., excess solar energy when supply exceeds demand). In addition to assessment maps and cumulative estimates, the new models of fractured reservoirs developed herein can be used to estimate steady power production given a set of fractures and well spacing, and estimates can be made for setback distances to ensure no thermal interference with nearby powerplants.

Arizona, California, Idaho, Nevada, Oregon, Utah↗

The advantages of electric-grade heat storage in long closed-loop wells

Though long (e.g., tens of kilometers) closed-loop geothermal wells are under consideration for the extraction of subsurface heat, these wells might also serve as an efficient energy storage mechanism for electricity generation. Using a semi-analytic model solution, the potential for electric-grade heat storage as a function of ambient temperature (e.g., corresponds to depth of loop), well length, well diameter, and flow rate is evaluated. The following simplified cases for comparison of standard closed loop operation with energy storage operation were considered: [1] constant flow rate and constant temperature (90 °C) injection to represent the standard closed-loop base-case; and [2] constant flow rate and annual cycle sinusoidal temperature (90-150 °C) to represent seasonal (summer) charging while solar resources are peak. Initial temperatures for all scenarios considered herein are a uniform 175 °C. Electric-grade heat is assumed to be delivered whenever temperatures at the extraction point exceed 90 °C. For calculation purposes only, if temperature falls below 100 °C, it is assumed that heat delivered is sub-economic, so no electricity would be produced. For all scenarios, temperatures at the extraction well asymptotically approach the flow-weighted average injection temperature, but energy storage scenarios exhibited a damped time-varying signal that diminishes in magnitude with length of the loop. The asymptotic approach depends on initial temperatures in the rock and the heat extraction rate (a function of well diameter and flowrate). This analysis demonstrates that shorter closed loops can produce more electricity over time than longer closed-loops previously proposed for electricity production over typical engineering design lifetimes (e.g., 30 years). Although only a high-temperature scenario is considered herein, rock that is initially below boiling temperature would not host a standard closed-loop resource, but injection of hot water seasonally would asymptotically heat this low-temperature system to temperatures capable of electricity production. In other words, regardless of initial temperatures, closed loops could be used to store electricity with no critical minerals in the geothermal battery.

Conference Paper↗

The influence of episodic shallow magma degassing on heat and chemical transport in volcanic hydrothermal systems

Springs at La Soufrière of Guadeloupe have been monitored for nearly four decades since the phreatic eruption and associated seismic activity in 1976. We conceptualize degassing vapor/gas mixtures as square‐wave sources of chloride and heat and apply a new semianalytic solution to demonstrate that chloride and heat pulses with the same timing and duration result in good matches between measured and simulated spring temperatures and concentrations. While the concentration of chloride pulses is variable, the local boiling temperature of 96°C was assigned to all thermal pulses. Because chloride is a conservative tracer, chloride breakthrough is only affected by one‐dimensional advection and dispersion. The thermal tracer is damped and lagged relative to chloride due to conductive heat exchange with the overlying and underlying strata. Joint analysis of temperature and chloride allows estimation of the onset and duration of degassing pulses, refining the chronology of recent magmatic intrusion.

Geophysical Research Letters↗

Thermal effect of climate change on groundwater-fed ecosystems

Groundwater temperature changes will lag surface temperature changes from a changing climate. Steady state solutions of the heat-transport equations are used to identify key processes that control the long-term thermal response of springs and other groundwater discharge to climate change, in particular changes in (1) groundwater recharge rate and temperature and (2) land-surface temperature transmitted through the vadose zone. Transient solutions are developed to estimate the time required for new thermal signals to arrive at ecosystems. The solution is applied to the volcanic Medicine Lake highlands, California, USA, and associated springs complexes that host groundwater-dependent ecosystems. In this system, upper basin groundwater temperatures are strongly affected only by recharge conditions. However, as the vadose zone thins away from the highlands, changes in the average annual land-surface temperature also influence groundwater temperatures. Transient response to temperature change depends on both the conductive time scale and the rate at which recharge delivers heat. Most of the thermal response of groundwater at high elevations will occur within 20 years of a shift in recharge temperatures, but the large lower elevation springs will respond more slowly, with about half of the conductive response occurring within the first 20 years and about half of the advective response to higher recharge temperatures occurring in approximately 60 years.

California↗