Geology Reports⌕ Search

Geology topics

Heather M. Bragg

Publications and source records attributed to Heather M. Bragg.

32 records · Page 2Linked to original sources

Total dissolved gas and water temperature in the lower Columbia River, Oregon and Washington, 2008: Quality-assurance data and comparison to water-quality standards

Significant Findings When water is released through the spillways of dams, air is entrained in the water, increasing the downstream concentration of dissolved gases. Excess dissolved-gas concentrations can have adverse effects on freshwater aquatic life. The U.S. Geological Survey (USGS), in cooperation with the U.S. Army Corps of Engineers, collected dissolved-gas and water-temperature data at eight monitoring stations on the lower Columbia River in Oregon and Washington in 2008. Significant findings from the data include: During the spill season of April through August 2008, hourly values of total-dissolved-gas (TDG) concentration were occasionally larger than 115-percent saturation for the forebay stations (John Day navigation lock, The Dalles forebay, Bonneville forebay, and Camas). Hourly values of TDG concentration were occasionally larger than 120-percent saturation for tailwater stations (John Day tailwater, The Dalles tailwater, and Cascade Island). From late July to September 2008, water temperatures were greater than 20°C (degrees Celsius) at seven stations on the lower Columbia River. According to the State of Oregon temperature standard, the 7-day average maximum temperature of the lower Columbia River should not exceed 20°C; Washington regulations state that the 1-day maximum should not exceed 20°C as a result of human activities. Each of the in situ field checks of TDG sensors with a secondary standard was within ±(plus or minus) 1-percent saturation after 3 to 4 weeks of deployment in the river. All field checks of barometric pressure were within ±2.0 millimeters of mercury of a secondary standard, and water-temperature field checks were all within ±0.2°C. For the eight monitoring stations in water year 2008, an average of 99.6 percent of the TDG data were received in real time by the USGS satellite downlink and were within 1-percent saturation of the expected value on the basis of calibration data, replicate quality-control measurements in the river, and comparison to ambient river conditions at adjacent stations. Data received from the individual stations ranged from 98.8 to 100.0 percent complete.

Oregon, Washington↗

Analysis of Geomorphic and Hydrologic Characteristics of Mount Jefferson Debris Flow, Oregon, November 6, 2006

On November 6, 2006, a rocky debris flow surged off the western slopes of Mount Jefferson into the drainage basins of Milk and Pamelia Creeks in Oregon. This debris flow was not a singular event, but rather a series of surges of both debris and flooding throughout the day. The event began during a severe storm that brought warm temperatures and heavy rainfall to the Pacific Northwest. Precipitation measurements near Mount Jefferson at Marion Forks and Santiam Junction showed that more than 16.1 centimeters of precipitation fell the week leading up to the event, including an additional 20.1 centimeters falling during the 2 days afterward. The flooding associated with the debris flow sent an estimated 15,500 to 21,000 metric tons, or 9,800 to 13,000 cubic meters, of suspended sediment downstream, increasing turbidity in the North Santiam River above Detroit Lake to an estimated 35,000 to 55,000 Formazin Nephelometric Units. The debris flow started small as rock and ice calved off an upper valley snowfield, but added volume as it eroded weakly consolidated deposits from previous debris flows, pyroclastic flows, and glacial moraines. Mud run-up markings on trees indicated that the flood stage of this event reached depths of at least 2.4 meters. Velocity calculations indicate that different surges of debris flow and flooding reached 3.9 meters per second. The debris flow reworked and deposited material ranging in size from sand to coarse boulders over a 0.1 square kilometer area, while flooding and scouring as much as 0.45 square kilometer. Based on cross-sectional transect measurements recreating pre-event topography and other field measurements, the total volume of the deposit ranged from 100,000 to 240,000 cubic meters.

Scientific Investigations Report↗

Total dissolved gas and water temperature in the lower Columbia River, Oregon and Washington, 2007: Quality-assurance data and comparison to water-quality standards

Significant Findings When water is released through the spillways of dams, air is entrained in the water, increasing the downstream concentration of dissolved gases. Excess dissolved-gas concentrations can have adverse effects on freshwater aquatic life. The U.S. Geological Survey (USGS), in cooperation with the U.S. Army Corps of Engineers, collected dissolved-gas and water-temperature data at eight sites on the lower Columbia River in 2007. Significant findings from the data include: From early July to mid-September 2007, water temperatures were above 20°C (degrees Celsius) at each of the eight lower Columbia River sites. According to the Oregon temperature standard, the 7-day average maximum temperature of the lower Columbia River should not exceed 20°C; Washington regulations state that the 1-day maximum should not exceed 20°C due to human activities. Most in-situ field checks of total-dissolved-gas sensors with a secondary standard were within ± (plus or minus) 1% saturation after 3 to 4 weeks of deployment in the river. All of the field checks of barometric pressure were within ±2.5 millimeter of mercury of a secondary standard, and water-temperature field checks were all within ±0.2 °C. For the eight monitoring sites in water year 2007, an average of 99.5% of the total-dissolved-gas data were received in real time by the USGS satellite downlink and were within 1% saturation of the expected value on the basis of calibration data, replicate quality-control measurements in the river, and comparison to ambient river conditions at adjacent sites. Data received from the sites ranged from 97.9% to 100.0% complete.

Lower Columbia River↗

Modeling Hydrodynamics, Water Temperature, and Suspended Sediment in Detroit Lake, Oregon

Detroit Lake is a large reservoir on the North Santiam River in west-central Oregon. Water temperature and suspended sediment are issues of concern in the river downstream of the reservoir. A CE-QUAL-W2 model was constructed to simulate hydrodynamics, water temperature, total dissolved solids, and suspended sediment in Detroit Lake. The model was calibrated for calendar years 2002 and 2003, and for a period of storm runoff from December 1, 2005, to February 1, 2006. Input data included lake bathymetry, meteorology, reservoir outflows, and tributary inflows, water temperatures, total dissolved solids, and suspended sediment concentrations. Two suspended sediment size groups were modeled: one for suspended sand and silt with particle diameters larger than 2 micrometers, and another for suspended clay with particle diameters less than or equal to 2 micrometers. The model was calibrated using lake stage data, lake profile data, and data from a continuous water-quality monitor on the North Santiam River near Niagara, about 6 kilometers downstream of Detroit Dam. The calibrated model was used to estimate sediment deposition in the reservoir, examine the sources of suspended sediment exiting the reservoir, and examine the effect of the reservoir on downstream water temperatures.

Scientific Investigations Report↗

Major Turbidity Events in the North Santiam River Basin, Oregon, Water Years 1999-2004

Multiple high-turbidity events with values greater than 250 Formazin Nephelometric Units occurred in streams of the North Santiam River basin during water years 1999-2004. By using a combination of field reconnaissance, aerial photography, and geographic information systems, eight of these high-turbidity events were investigated and linked to at least one likely source area and became known as 'major turbidity events.' Sediment source type and location, the amount of material transported, and the results of any follow-up investigation of the source area were recorded for each event. Significant findings from this study include: * Although heavy precipitation caused basinwide erosion that increased turbidity in streams, a major turbidity event often required at least one landslide or similar type of contributing source to introduce enough sediment to raise the turbidity value to greater than 250 Formazin Nephelometric Units. * Different processes drove sediment loading at different times. In general, precipitation eroded sediment from source areas or induced landslides. However, in two cases, warm temperatures caused rapid snowmelt, which supplied the water necessary to erode unconsolidated glacial soils or other sediment material and increase turbidity. * Some source areas, such as existing earthflows, repeatedly supplied a large volume of sediment to streams, whereas other sources, such as landslides or debris flows, were unpredictable and sporadically supplied large volumes of sediment to streams. * Major turbidity events were well distributed throughout the North Santiam River basin; discrete events were observed in each of the five subbasins along unregulated streams. * Suspended-sediment loads and clay-water (persistently turbid water) volume estimates were event-specific and varied greatly between major turbidity events, even though, in some cases, the source area was the same; however, high yields generally were observed for events in the Blowout Creek, Breitenbush River, and Little North Santiam River subbasins. * Suspended-sediment loads for each 3-day precipitation-driven major turbidity event supplied greater than 36 percent of the annual load, and snowmelt-driven events supplied greater than 27 percent of the annual load in a single day. * Clay-water yields for event periods generally were highest in the Little North Santiam River subbasin. In addition, average annual percentage of clay-water volume during the period of record was highest in the Little North Santiam River. The second highest average was in Blowout Creek.

Scientific Investigations Report↗

Suspended-Sediment Loads and Yields in the North Santiam River Basin, Oregon, Water Years 1999-2004

The North Santiam River provides drinking water to the residents and businesses of the city of Salem, Oregon, and many surrounding communities. Since 1998, water-quality data, including turbidity, were collected continuously at monitoring stations throughout the basin as part of the North Santiam River Basin Turbidity and Suspended Sediment Study. In addition, sediment samples have been collected over a range of turbidity and streamflow values. Regression models were developed between the instream turbidity and suspended-sediment concentration from the samples collected from each monitoring station. The models were then used to estimate the daily and annual suspended-sediment loads and yields. For water years 1999-2004, suspended-sediment loads and yields were estimated for each station. Annual suspended-sediment loads and yields were highest during water years 1999 and 2000. A drought during water year 2001 resulted in the lowest suspended-sediment loads and yields for all monitoring stations. High-turbidity events that were unrelated or disproportional to increased streamflow occurred at several of the monitoring stations during the period of study. These events highlight the advantage of estimating suspended-sediment loads and yields from instream turbidity rather than from streamflow alone.

Scientific Investigations Report↗

Total dissolved gas and water temperature in the lower Columbia River, Oregon and Washington, 2006: Quality-assurance data and comparison to water-quality standards

Significant Findings When water is released through the spillways of dams, air is entrained in the water, increasing the downstream concentration of dissolved gases. Excess dissolved-gas concentrations can have ad-verse effects on freshwater aquatic life. The U.S. Geological Survey (USGS), in cooperation with the U.S. Army Corps of Engineers, collected dissolved-gas concentration and water-temperature data at eight stations on the lower Columbia River in 2006. Significant findings from the data include: Variances to the Oregon and Washington water-quality standards for total dissolved gas were exceeded at all of the monitoring stations: Cascade Island (67 days), Camas (60 days), Bonneville forebay (51 days), The Dalles forebay (36 days), John Day tailwater (35 days), John Day navigation lock (20 days), The Dalles tailwater (8 days), and Warrendale (4 days). From early July to the end of August 2006, water temperatures were above 20°C (degrees Celsius) at each of the eight lower Columbia River stations. According to the Oregon temperature standard, the 7-day average maximum temperature of the lower Columbia River should not exceed 20°C; Washington regulations state that the 1-day maximum should not exceed 20°C due to human activities. Most field checks of total-dissolved-gas sensors with a secondary standard were within ± (plus or minus) 1% saturation. All of the field checks of barometric pressure were within ±1 millimeter of mercury of a secondary standard, and water temperature field checks were all within ±0.2°C. For the eight monitoring stations in water year 2006, an average of 99.1% of the total-dissolved-gas data were received in real time by the USGS satellite downlink and were within 1% saturation of the expected value on the basis of calibration data, replicate quality-control measurements in the river, and comparison to ambient river conditions at adjacent stations.

Oregon, Washington↗

Total dissolved gas and water temperature in the lower Columbia River, Oregon and Washington, 2005: quality-assurance data and comparison to water-quality standards

Significant Findings When water is released through the spillways of dams, air is entrained in the water, increasing the downstream concentration of dissolved gases. Excess dissolved-gas concentrations can have adverse effects on freshwater aquatic life. The U.S. Geological Survey (USGS), in cooperation with the U.S. Army Corps of Engineers, collected dissolved-gas and water-temperature data at eight sites on the lower Columbia River in 2005. Significant findings from the data include: Variances to the Oregon and Washington water-quality standards for total dissolved gas were exceeded at five of the monitoring sites: Camas (11 days), John Day tailwater (3 days), The Dalles forebay (3 days), Bonneville forebay (3 days), and John Day navigation lock (1 day). From mid-July to early September, water temperatures were above 20°C (degrees Celsius) at each of the eight lower Columbia River sites. According to the Oregon temperature standard, the 7-day average maximum temperature of the lower Columbia River should not exceed 20°C; Washington regulations state that the 1-day maximum should not exceed 20°C due to human activities. Most field checks of total-dissolved-gas sensors with a secondary standard were within ± (plus or minus) 1% saturation. Most of the field checks of barometric pressure were within ±1 millimeter of mercury of a secondary standard, and water temperature field checks were all within ±0.2°C. For the eight monitoring sites in water year 2005, an average of 98.2% of the total-dissolved-gas data were received in real time by the USGS satellite downlink and were within 1% saturation of the expected value, based on calibration data, replicate quality-control measurements in the river, and comparison to ambient river conditions at adjacent sites.

Oregon, Washington↗

Total dissolved gas and water temperature in the lower Columbia river, Oregon and Washington, 2004: Quality-assurance data and comparison to water-quality standards

Significant Findings When water is released through the spillways of dams, air is entrained in the water, increasing the downstream concentration of total dissolved gas. Excess dissolved-gas concentrations can have adverse effects on freshwater aquatic life. The U.S. Geological Survey (USGS), in cooperation with the U.S. Army Corps of Engineers (USACE), collected total-dissolved-gas (TDG) and water-temperature data at eight sites on the lower Columbia River in 2004. Significant findings from the data include: Variances to the Oregon and Washington water-quality standards for total dissolved gas were exceeded on a few days at three of the monitoring sites: Camas, The Dalles forebay, and Bonneville forebay. These exceedances may have been the result of the cumulative effects of supersaturated water moving downstream through the lower Columbia River. Apparently, the levels of TDG did not dissipate rapidly enough downstream from the dams before reaching the next site. TDG levels at an experimental monitoring site directly below Bonneville Dam at Cascade Island showed a larger response to spill than the site 5.5 miles farther downstream at Warrendale. From mid-July to mid-September, water temperatures were above 20°C (degrees Celsius) at each of the seven lower Columbia River sites. Both the Oregon and Washington water-quality standards contain a numerical standard of 20°C for the lower Columbia River. The new location of the forebay monitoring site at John Day navigation lock showed less daily temperature variation than the previous location. The probe at the new site was farther away from the dam and at a greater depth, so it apparently avoided the daily temperature excursions associated with the surface-layer heating at the previous site. Most field checks of total-dissolved-gas sensors with a secondary standard were within ±1% saturation. Most of the field checks of barometric pressure were within ±1 mm Hg (millimeter of mercury) of a secondary standard, and water temperature field checks were all within ±0.1°C. For the seven monitoring sites used to regulate spill in water year 2004, an average of 99.0% of the total- dissolved-gas data were received in real time by the USGS satellite downlink and were within 1% saturation of the expected value, based on calibration data, replicate quality-control measurements in the river, and comparison to ambient river conditions at adjacent sites.

Oregon, Washington↗

Monitoring instream turbidity to estimate continuous suspended-sediment loads and yields and clay-water volumes in the upper North Santiam River Basin, Oregon, 1998-2000

Three real-time, instream water-quality and turbidity-monitoring sites were established in October 1998 in the upper North Santiam River Basin on the North Santiam River, the Breitenbush River, and Blowout Creek, the main tributary inputs to Detroit Lake, a large, controlled reservoir that extends from river mile 61 to 70. Suspended-sediment samples were collected biweekly to monthly at each station. Rating curves provided estimated suspended-sediment concentration in 30-minute increments from log transformations of the instream turbidity monitoring data. Turbidity was found to be a better surrogate than discharge for estimating suspended-sediment concentration. Daily and annual mean suspended-sediment loads were estimated using the estimated suspended-sediment concentrations and corresponding streamflow data. A laboratory method for estimating persistent (residual) turbidity from separate turbidity samples was developed. Turbidity was measured over time for each sample. Turbidity decay curves were derived as the suspended sediment settled. Each curve was used to estimate a turbidity value for a given settling time. Medium to fine clay particle (< 0.002 mm [millimeter] diameter) settling times of 8.5 hours were computed using Stokes Law. An average of 30 persistent turbidity samples was collected from each of the 3 sites. These samples were used to estimate the 0.002-mm-size clay particle persistent turbidity for each site. The monitored instream 30-minute turbidity values were converted to a calculated persistent turbidity value that would have resulted after 8.5 hours of settling in the laboratory. Persistent turbidities of 10 NTU and above were tabulated for each site. (Water of 10 NTU and above can interfere with or damage treatment filters and result in intake closures at drinking-water facilities.) A method was developed that used the persistent turbidity experiments, turbidity decay curves, and stream discharge to estimate the volume of water containing suspended clay that entered Detroit Lake from the three main tributaries. 'Suspended-clay water' was defined as water having a value of at least 10 NTU after settling the required 8.5 hours. The suspended-clay concentrations of 10 NTU or higher were paired with the corresponding stream discharge in the continuous record. These summed discharges represent the annual volume of water containing suspended clay that entered Detroit Lake from the three main tributaries. Higher yields (load per unit area) of suspended sediment and suspended-clay water were observed from the smaller Breitenbush River and Blowout Creek subbasins than from the main-stem North Santiam River for water years 1999 and 2000. The 3-day peak streamflow and turbidity events in 1999 and 2000 carried two-thirds of the annual suspended-sediment load for the three subbasins. Turbidity and suspended-sediment concentration relations within the upper North Santiam River Basin are basin specific and can change annually within a single subbasin. Techniques developed during this study will assist water resource planners in understanding and managing water quality in their watersheds, particularly those in which there are persistent-turbidity problems.

Water-Resources Investigations Report↗

Total dissolved gas and water temperature in the lower Columbia River, Oregon and Washington, 2003: Quality-assurance data and comparison to water-quality standards

Significant Findings When water is released through the spillways of dams, air is entrained in the water, increasing the concentration of total dissolved gas. Excess dissolved-gas concentrations can have adverse effects on freshwater aquatic life. The U.S. Geological Survey (USGS), in cooperation with the U.S. Army Corps of Engineers, collected total- dissolved-gas and water-temperature data at seven sites on the lower Columbia River in 2003. Significant findings from the data include: For the seven monitoring sites in water year 2003, an average of 98.9% of the total-dissolved-gas data were received in real time by the USGS satellite downlink and were within 1% saturation of the expected value, based on calibration data, replicate quality-control measurements in the river, and comparison to ambient river conditions at adjacent sites. Most field checks of total-dissolved-gas sensors with a secondary standard were within plus or minus 1% saturation. Field checks of barometric pressure and water temperature were usually within plus or minus 1 millimeter of mercury and plus or minus 0.1 degree Celsius, respectively. The variances to the States of Oregon and Washington water-quality standards for total dissolved gas were exceeded at six of the seven monitoring sites. The sites at Camas and Bonneville forebay had the most days exceeding the variance of 115% saturation. The forebay exceedances may have been the result of the cumulative effects of supersaturated water moving downstream through the lower Columbia River. Apparently, the levels of total dissolved gas did not decrease rapidly enough downstream from the dams before reaching the next site. From mid-July to mid-September, water temperatures were usually above 20 degrees Celsius at each of the seven lower Columbia River sites. According to the Oregon water-quality standard, when the temperature of the lower Columbia River exceeds 20 degrees Celsius, no measurable temperature increase resulting from anthropogenic activities is allowed. Transient increases of about 1 degree Celsius were noted at the John Day forebay site, due to localized solar heating.

Oregon, Washington↗

Total dissolved gas and water temperature in the lower Columbia River, Oregon and Washington, 2002: Quality-assurance data and comparison to water-quality standards

Significant Findings The U.S. Geological Survey (USGS), in cooperation with the U.S. Army Corps of Engineers, collected total-dissolved-gas and water-temperature data at eight sites near dams on the lower Columbia River in 2002. When water is released through the spillways of dams, air is entrained in the water, increasing the concentration of total dissolved gas to levels that can have adverse effects on freshwater aquatic life. Significant findings include: For the eight monitoring sites in water year 2002, an average of 99.6% of the total-dissolved gas data were received in real time by the USGS satellite downlink and were within 1% saturation of the expected value, based on calibration data and ambient river conditions at adjacent sites. Most field checks of total-dissolved-gas sensors with a secondary standard were within 1% saturation. Field checks of barometric pressure and water temperature were usually within 1 millimeter of mercury and 0.05 degrees Celsius, respectively. In June and July 2002, spills exceeded 140,000 cubic feet per second at the John Day, The Dalles, and Bonneville Dams. These spills resulted in levels of total dissolved gas that exceeded 120% saturation downstream of the dams. The variance to the State of Oregon water-quality standard for total dissolved gas of 110% saturation was exceeded at seven of the eight monitoring sites. The sites at Camas and Bonneville are considered forebay sites and had the most days exceeding the variance of 115% saturation. The forebay exceedances may have been the result of the cumulative effects of significant spill throughout the lower Columbia River. Apparently, the levels of total dissolved gas did not dissipate rapidly enough downstream of the dams before reaching the next site. From mid-July to mid-September, water temperatures were usually above 20 degrees Celsius at each of the seven lower Columbia River sites in operation. According to the Oregon water-quality standard, when the temperature of the lower Columbia River exceeds 20 degrees Celsius, no measurable temperature increase resulting from anthropogenic activities is allowed.

Oregon, Washington↗

Quality-assurance data, comparison to water-quality standards, and site considerations for total dissolved gas and water temperature, lower Columbia River, Oregon and Washington, 2001

Significant Findings For eight monitoring sites, in water year 2001, an average of 99.3% of the total-dissolved-gas data were received in real time and passed quality-assurance checks. After 2 to 3 weeks of deployment in the river, most comparisons of field total-dissolved-gas sensors with a secondary standard (another calibrated total-dissolved-gas sensor) were within 1%. The only exceedances of Oregon water-quality standards for total dissolved gas occurred on May 23 and 24, 2001, at the Camas, Washington, station. At the forebay of the John Day Dam, temporary increases in water temperature and total dissolved gas occurred on hot afternoons during periods of low wind. These increases were not observed at the John Day tailwater station. At Camas, Washington, daily variations of total dissolved gas were probably due to the production of oxygen by aquatic plants and to water-temperature variations on warm, sunny days. During spill over Bonneville Dam in water year 2001, the site on the Oregon side of the Columbia River, Warrendale, measured larger total-dissolved-gas levels than the site directly across on the Washington side at Skamania. Apparently, streamflow through generating facilities on the north side of the dam forced supersaturated water from the spill bays over to the Oregon side of the river. At times in July and August 2001, the total-dissolved-gas probe at Warrendale could not be positioned below the minimum compensation depth because the river was too shallow at that location. Consequently, degassing at probe depth may have occurred, and total dissolved gas may have been larger in locations with greater depths.

Oregon, Washington↗