Geology Reports⌕ Search

Geology topics

Esad Micijevic

Publications and source records attributed to Esad Micijevic.

41 records · Page 3Linked to original sources

Development of Landsat-5 thematic mapper internal calibrator gain and offset table

The National Landsat Archive Production System (NLAPS) has been the primary processing system for Landsat data since U.S. Geological Survey (USGS) Earth Resources Observation and Science Center (EROS) started archiving Landsat data. NLAPS converts raw satellite data into radiometrically and geometrically calibrated products. NLAPS has historically used the Internal Calibrator (IC) to calibrate the reflective bands of the Landsat-5 Thematic Mapper (TM), even though the lamps in the IC were less stable than the TM detectors, as evidenced by vicarious calibration results. In 2003, a major effort was made to model the actual TM gain change and to update NLAPS to use this model rather than the unstable IC data for radiometric calibration. The model coefficients were revised in 2007 to reflect greater understanding of the changes in the TM responsivity. While the calibration updates are important to users with recently processed data, the processing system no longer calculates the original IC gain or offset. For specific applications, it is useful to have a record of the gain and offset actually applied to the older data. Thus, the NLAPS calibration database was used to generate estimated daily values for the radiometric gain and offset that might have been applied to TM data. This paper discusses the need for and generation of the NLAPS IC gain and offset tables. A companion paper covers the application of and errors associated with using these tables.

Conference Paper↗

Radiometric recalibration procedure for Landsat-5 Thematic Mapper data

The Landsat-5 (L5) satellite was launched on March 01, 1984, with a design life of three years. Incredibly, the L5 Thematic Mapper (TM) has collected data for 23 years. Over this time, the detectors have aged, and its radiometric characteristics have changed since launch. The calibration procedures and parameters have also changed with time. Revised radiometric calibrations have improved the radiometric accuracy of recently processed data; however, users with data that were processed prior to the calibration update do not benefit from the revisions. A procedure has been developed to give users the ability to recalibrate their existing Level 1 (Ll) products without having to purchase reprocessed data from the U.S. Geological Survey (USGS). The accuracy of the recalibration is dependent on the knowledge of the prior calibration applied to the data. The “Work Order” File, included with standard National Land Archive Production System (NLAPS) data products, gives parameters that define the applied calibration. These are the Internal Calibrator (IC) calibration parameters or the default prelaunch calibration, if there were problems with the IC calibration. This paper details the recalibration procedure for data processed using IC, in which users have the Work Order file.

Conference Paper↗

Stability of Landsat-4 thematic mapper outgassing models

Oscillations in radiometric gains of the short wave infrared (SWIR) bands in Landsat-4 (L4) and Landsat-5 (L5) Thematic Mappers (TMs) are observed through an analysis of detector responses to the Internal Calibrator (IC) pulses. The oscillations are believed to be caused by an interference effect due to a contaminant film buildup on the window of the cryogenically cooled dewar that houses these detectors. This process of contamination, referred to as outgassing effects, has been well characterized using an optical thin-film model that relates detector responses to the accumulated film thickness and its growth rate. The current models for L4 TM are based on average detector responses to the second brightest IC lamp and have been derived from three data sets acquired during different times throughout the instrument's lifetime. Unlike in L5 TM outgassing characterization, it was found that the L4 TM responses to all three IC lamps can be used to provide accurate characterization and correction for outgassing effects. The analysis of single detector responses revealed an up to five percent difference in the estimated oscillating periods and also indicated a gradual variation of contaminant growth rate over the focal plane.

Conference Paper↗

Improvement in absolute calibration accuracy of Landsat-5 TM with Landsat-7 ETM+ data

The ability to detect and quantify changes in the Earth's environment depends on satellites sensors that can provide calibrated, consistent measurements of Earth's surface features through time. A critical step in this process is to put image data from subsequent generations of sensors onto a common radiometric scale. To evaluate Landsat-5 (L5) Thematic Mapper's (TM) utility in this role, image pairs from the L5 TM and Landsat-7 (L7) Enhanced Thematic Mapper Plus (ETM+) sensors were compared. This approach involves comparison of surface observations based on image statistics from large common areas observed eight days apart by the two sensors. The results indicate a significant improvement in the consistency of L5 TM data with respect to L7 ETM+ data, achieved using a revised Look-Up-Table (LUT) procedure as opposed to the historical Internal Calibrator (IC) procedure previously used in the L5 TM product generation system. The average percent difference in reflectance estimates obtained from the L5 TM agree with those from the L7 ETM+ in the Visible and Near Infrared (VNIR) bands to within four percent and in the Short Wave Infrared (SWIR) bands to within six percent.

Conference Paper↗

Outgassing models for Landsat-4 thematic mapper short wave infrared bands

Detector responses to the Internal Calibrator (IC) pulses in the Landsat-4 Thematic Mapper (TM) have been observed to follow an oscillatory behavior. This phenomenon is present only in the Short Wave Infrared (SWIR) bands and has been observed throughout the lifetime of the instrument, which was launched in July 1982 and imaged the Earth's surface until late 1993. These periodic changes in amplitude, which can be as large as 7.5 percent, are known as outgassing effects and are believed to be due to optical interference caused by a gradual buildup of an ice-like material on the window of the cryogenically cooled dewar containing the SWIR detectors. Similar outgassing effects in the Landsat-5 TM have been characterized using an optical thin-film model that relates detector behavior to the ice film growth rate, which was found to gradually decrease with time. A similar approach, which takes into consideration the different operational history of the instrument, has been applied in this study to three closely sampled data sets acquired throughout the lifetime of the Landsat-4 TM. Although Landsat-4 and Landsat-5 Thematic Mappers are essentially identical instruments, data generated from analyses of outgassing effects indicate subtle, but important, differences between the two. The estimated lifetime model could improve radiometric accuracy by as much as five percent.

Conference Paper↗