Geology Reports⌕ Search

Geology topics

Esad Micijevic

Publications and source records attributed to Esad Micijevic.

At least 37 records · Page 2Linked to original sources

The 50-year Landsat collection 2 archive

The Landsat global consolidated data archive now exceeds 50 years. In recognition of the need for consistently processed data across the Landsat satellite series, the U.S. Geological Survey (USGS) initiated collection-based processing of the entire archive that was processed as Collection 1 in 2016. In preparation for the data from the now successfully launched Landsat 9, the USGS reprocessed the Landsat archive as Collection 2 in 2020. This paper describes the rationale for, and the contents and advancements provided by Collection 2, and highlights the differences between the Collection 1 and Collection 2 products. Notably, the Collection 2 products have improved geolocation and, for the first time, the USGS provides a global inventory of Level 2 surface reflectance and surface temperature products. Also for the first time, the USGS used a commercial cloud computing architecture to efficiently process the archive and enable direct cloud access of the Landsat products. The paper concludes with discussion of likely improvements expected in Collection 3 in preparation for the Landsat Next mission that is planned for launch in the early 2030s.

Science of Remote Sensing↗

ECCOE Landsat Quarterly Calibration and Validation report—Quarter 2, 2022

Executive Summary The U.S. Geological Survey Earth Resources Observation and Science Calibration and Validation (Cal/Val) Center of Excellence (ECCOE) focuses on improving the accuracy, precision, calibration, and product quality of remote-sensing data, leveraging years of multiscale optical system geometric and radiometric calibration and characterization experience. The ECCOE Landsat Cal/Val Team continually monitors the geometric and radiometric performance of active Landsat missions and makes calibration adjustments, as needed, to maintain data quality at the highest level. This report provides observed geometric and radiometric analysis results for Landsats 7–8 for quarter 2 (April–June), 2022. All data used to compile the Cal/Val analysis results presented in this report are freely available from the U.S. Geological Survey EarthExplorer website: https://earthexplorer.usgs.gov . One specific activity that the ECCOE Landsat Cal/Val Team closely monitored was the lowering of the Landsat 7 orbit. On April 6, 2022, the Landsat 7 Enhanced Thematic Mapper Plus (ETM+) sensor was placed into standby mode, and a series of spacecraft burns was completed throughout the month of April to lower the satellite’s orbit by 8 kilometers. Imaging resumed at the lower orbit of 697 kilometers on May 5, 2022, extending the science mission to allow for essential data to be acquired during the 2022 Northern Hemisphere fire and growing season. Additional information about the Landsat 7 orbit lowering is here: https://www.usgs.gov/centers/eros/news/landsat-7-lowered-standard-landsat-orbit#:~:text=The%20satellite's%20primary%20science%20mission%20has%20ended&text=On%20April%206%2C%202022%2C%20the,satellite's%20orbit%20by%208%20kilometers .

Open-File Report↗

ECCOE Landsat Quarterly Calibration and Validation report—Quarter 1, 2022

Executive Summary The U.S. Geological Survey (USGS) Earth Resources Observation and Science (EROS) Calibration and Validation (Cal/Val) Center of Excellence (ECCOE) focuses on improving the accuracy, precision, calibration, and product quality of remote-sensing data, leveraging years of multiscale optical system geometric and radiometric calibration and characterization experience. The ECCOE Landsat Cal/Val Team continually monitors the geometric and radiometric performance of active Landsat missions and makes calibration adjustments, as needed, to maintain data quality at the highest level. This report provides observed geometric and radiometric analysis results for Landsats 7–8 for quarter 1 (January–March), 2022. All data used to compile the Cal/Val analysis results presented in this report are freely available from the USGS EarthExplorer website: https://earthexplorer.usgs.gov . One specific activity that the Cal/Val Team continued to closely monitor this quarter was the Landsat 8 Thermal Infrared Sensor (TIRS) response degradation, which has been observed since the two November 2020 safehold events. Detailed analysis results characterizing this degradation have been included in this report. Additional information about the safehold events is here: https://www.usgs.gov/core-science-systems/nli/landsat/november-19-2020-landsat-8-data-availability-update-recent-safehold .

Open-File Report↗

ECCOE Landsat Quarterly Calibration and Validation report— Quarter 4, 2021

Executive Summary The U.S. Geological Survey (USGS) Earth Resources Observation and Science (EROS) Calibration and Validation (Cal/Val) Center of Excellence (ECCOE) focuses on improving the accuracy, precision, calibration, and product quality of remote-sensing data, leveraging years of multiscale optical system geometric and radiometric calibration and characterization experience. The ECCOE Landsat Cal/Val Team continually monitors the geometric and radiometric performance of active Landsat missions and makes calibration adjustments, as needed, to maintain data quality at the highest level. This report provides observed geometric and radiometric analysis results for Landsats 7–8 for quarter 4 (October–December), 2021. All data used to compile the Cal/Val analysis results presented in this report are freely available from the USGS EarthExplorer website: https://earthexplorer.usgs.gov . One specific activity that the Cal/Val Team continued to closely monitor this quarter was the Landsat 8 Thermal Infrared Sensor (TIRS) response degradation, which has been observed since the two November 2020 safehold events. Detailed analysis results characterizing this degradation have been included in this report. Additional information about the safehold events is here: https://www.usgs.gov/core-science-systems/nli/landsat/november-19-2020-landsat-8-data-availability-update-recent-safehold .

Open-File Report↗

ECCOE Landsat quarterly Calibration and Validation report—Quarter 3, 2021

Executive Summary The U.S. Geological Survey (USGS) Earth Resources Observation and Science (EROS) Calibration and Validation (Cal/Val) Center of Excellence (ECCOE) focuses on improving the accuracy, precision, calibration, and product quality of remote-sensing data, leveraging years of multiscale optical system geometric and radiometric calibration and characterization experience. The ECCOE Landsat Cal/Val Team continually monitors the geometric and radiometric performance of active Landsat missions and makes calibration adjustments, as needed, to maintain data quality at the highest level. This report provides observed geometric and radiometric analysis results for Landsats 7–8 for quarter 3 (July–September), 2021. All data used to compile the Cal/Val analysis results presented in this report are freely available from the USGS EarthExplorer website: https://earthexplorer.usgs.gov . One specific activity that the Cal/Val Team continued to closely monitor this quarter was the Landsat 8 Thermal Infrared Sensor (TIRS) response degradation, which has been observed since the two November 2020 safehold events. Detailed analysis results characterizing this degradation have been included in this report. Additional information about the safehold events is here: https://www.usgs.gov/core-science-systems/nli/landsat/november-19-2020-landsat-8-data-availability-update-recent-safehold .

Open-File Report↗

ECCOE Landsat quarterly Calibration and Validation report — Quarter 2, 2021

Executive Summary The U.S. Geological Survey (USGS) Earth Resources Observation and Science (EROS) Calibration and Validation (Cal/Val) Center of Excellence (ECCOE) focuses on improving the accuracy, precision, calibration, and product quality of remote-sensing data, leveraging years of multiscale optical system geometric and radiometric calibration and characterization experience. The ECCOE Landsat Cal/Val Team continually monitors the geometric and radiometric performance of active Landsat missions and makes calibration adjustments, as needed, to maintain data quality at the highest level. This report provides observed geometric and radiometric analysis results for Landsats 7–8 for quarter 2 (April–June), 2021. All data used to compile the Cal/Val analysis results presented in this report are freely available from the USGS EarthExplorer website: https://earthexplorer.usgs.gov . One specific activity that the Cal/Val Team continued to closely monitor this quarter was the Landsat 8 Thermal Infrared Sensor (TIRS) response degradation, which has been observed since the two November 2020 safehold events. Detailed analysis results characterizing this degradation have been included in this report. Additional information about the safehold events is here: https://www.usgs.gov/core-science-systems/nli/landsat/november-19-2020-landsat-8-data-availability-update-recent-safehold .

Open-File Report↗

Radiometric performance of Landsat 8 Collection 2 products

The U.S. Geological Survey (USGS) archive of Earth images acquired by Landsat 1-8 sensors is organized in collections of consistently calibrated, geolocated, and processed data products. Such an organization ensures consistent quality of the archived data within a collection over time and across all instruments within the Landsat mission. In December 2020, the USGS completed reprocessing of the archived Landsat data and released a new collection, Collection 2, which introduced surface reflectance and surface temperature Level-2 products, implemented improved ground control and elevation datasets, and brought several geometric and radiometric calibration enhancements. Radiometric enhancements include absolute and relative gain updates for both imaging sensors, Operational Land Imager (OLI) and Thermal Infrared Sensor (TIRS), aboard Landsat 8 and a change in calculation of bias for OLI. In this paper we present the analysis of Collection 2 Landsat 8 products demonstrating stability over the mission lifetime, the improvement in OLI signal to noise ratio and along-track striping performance resulting from enhanced bias correction, as well as reduction of cross-track striping in TIRS data as a result of relative gain updates. In addition, we discuss effects of two safehold events that Landsat 8 experienced in November 2020 on the radiometric calibration of both sensors and product performance.

Conference Paper↗

Comparing geometric differences between Landsat Collection 1 to Collection 2 level-1 products

In late 2020 the U.S. Geological Survey (USGS) began the distribution of Landsat products associated with their collection 2 reprocessing of the archive. Several changes were implemented within the Landsat Product Generation System (LPGS) and the calibration parameters applied to the Landsat imagery for the collection 2 processing. When comparing between collection 1 and collection 2 products, radiometric and geometric differences will be present. One of the most substantial changes between the two collections was an adjustment to the ground control which made the control more accurate from an absolute and relative perspective. Some of the other changes associated with collection 2 processing were to the Digital Elevation Model (DEM) used in terrain correction, the Thermal Infrared Sensor (TIRS) relative gains, TIRS absolute calibration, Operational Land Imagery (OLI) absolute gain model, OLI relative gain, and OLI bias calculation to name a few. Although these changes also have an effect on the differences between the product associated with these two collections, the change in the ground control, although typically less than one 30-meter multispectral pixel in magnitude, will have the largest effect on the differences between the products. This change in ground control is also a spatially dynamic change that although is low in spatial frequency, is nonlinear and is not a change that can be modeled on a global or even on a local Worldwide Reference System-2 (WRS-2) path and row scale. The effects of these ground control changes will be discussed and demonstrated within this paper along with examples showing their effect on specific datasets. This paper demonstrates some of these geometric differences associated with the ground control through both the registration statistics created during product generation and through an example comparison of a set of collection 1 and collection 2 products.

Conference Paper↗

Landsat Collection 2 geometric calibration updates

The U.S. Geological Survey (USGS) changed the management and delivery of Landsat products to the public in its archive through the implementation of Collections. The Collections process ensures consistent data quality through time and across all the Landsat sensors with a few modifications to the metadata. The consistent data products from Collections are more conducive for applications such as time-series analysis, because the data can be used without a need for sensor-specific geometric or radiometric adjustments. The Collections process also allows for calibration improvements from updated reference sources, model trending, and enhanced algorithms that are grouped together and applied at one time, thus limiting the operational impacts to users. The first collection, Collection-1 was released in 2016, and Collection-2 is expected to be released in 2020. This paper addresses the geometric improvements to the Collection -2 dataset. Geometric improvements in Collection-2 include improvements to the geometric accuracy and interoperability of all Landsat products by implementing the Sentinel 2 Global Reference Image (GRI), improved elevation dataset using NASADEM and other sources of Digital Elevation Model (DEM) for terrain correction, improvements to the precision correction process for Enhanced Thematic Mapper Plus (ETM+) and Thematic Mapper (TM) sensors, changes to the Thermal Infrared Sensor (TIRS) to Operational Land Imager (OLI) alignment estimates, thermal band detector alignments and focal plane adjustments for ETM+, and improvements to the ETM+ sensor to attitude control system (ACS).

Conference Paper↗

Landsat 1-5 Multispectral Scanner System (MSS) sensors radiometric calibration update

First launched in 1972, the Landsat satellite sensors have provided the longest continuous record of high quality images of the Earth’s surface that are used in both civilian and military applications. The Landsat Multispectral Scanner (MSS) sensor was on-board Landsat-1 through Landsat-5. In fact, the MSS sensors provide the only systematic global multispectral space-based imagery of the Earth’s surface from 1972 to 1982. This paper focuses on the radiometric calibration update of the Landsat 1-5 MSS sensors. The radiometric calibration was performed in both radiance and reflectance-based scales through cross-calibration approach. Simultaneous or a near simultaneous image collections were available for MSS sensor pairs and used for the cross-calibration. The estimated uncertainties for this calibration update exhibit progressively decreasing calibration accuracy, ranging from 5.1% for MSS 5 to 8.8% for MSS-1 in the Green spectral band, for example. Lastly, the new radiometric calibration coefficients were validated through the use of pseudo invariant calibration sites (PICS). The temporal TOA Radiance and TOA Reflectance over the Sonoran Desert were plotted with the purpose of verifying the lifetime radiometric stability of MSS sensors. With the previous calibration, the agreement between the measurements of TOA Reflectance over the Sonoran Desert was around 7.5% for all spectral bands. With the calibration update implemented in this study, the agreement between MSS sensors is 3.6%, 2.9%, 3.5% and 5.9% for the Green, Red, NIR-1 and NIR 2 spectral bands, respectively. This study ties all the Landsat legacy instruments from Landsat-1 MSS through Landsat-8 OLI to a consistent radiometric scale.

IEEE Transactions on Geoscience and Remote Sensing↗

Radiometric characterization of Landsat Collection 1 products

Landsat data in the U.S. Geological Survey (USGS) archive are being reprocessed to generate a tiered collection of consistently geolocated and radiometrically calibrated products that are suitable for time series analyses. With the implementation of the collection management, no major updates will be made to calibration of the Landsat sensors within a collection. Only calibration parameters needed to maintain the established calibration trends without an effect on derived environmental records will be regularly updated, while all other changes will be deferred to a new collection. This first collection, Collection 1, incorporates various radiometric calibration updates to all Landsat sensors including absolute and relative gains for Landsat 8 Operational Land Imager (OLI), stray light correction for Landsat 8 Thermal Infrared Sensor (TIRS), absolute gains for Landsat 4 and 5 Thematic Mappers (TM), recalibration of Landsat 1-5 Multispectral Scanners (MSS) to ensure radiometric consistency among different formats of archived MSS data, and a transfer of Landsat 8 OLI reflectance based calibration to all previous Landsat sensors. While all OLI/TIRS, ETM+ and majority of TM data have already been reprocessed to Collection 1, a completion of MSS and remaining TM data reprocessing is expected by the end of this year. It is important to note that, although still available for download from the USGS web pages, the products generated using the Pre-Collection processing do not benefit from the latest radiometric calibration updates. In this paper, we are assessing radiometry of solar reflective bands in Landsat Collection 1 products through analysis of trends in on-board calibrator and pseudo invariant site (PICS) responses.

Conference Paper↗

Radiometric calibration updates to the Landsat collection

The Landsat Project is planning to implement a new collection management strategy for Landsat products generated at the U.S. Geological Survey (USGS) Earth Resources Observation and Science (EROS) Center. The goal of the initiative is to identify a collection of consistently geolocated and radiometrically calibrated images across the entire Landsat archive that is readily suitable for time-series analyses. In order to perform an accurate land change analysis, the data from all Landsat sensors must be on the same radiometric scale. Landsat 7 Enhanced Thematic Mapper Plus (ETM+) is calibrated to a radiance standard and all previous sensors are cross-calibrated to its radiometric scale. Landsat 8 Operational Land Imager (OLI) is calibrated to both radiance and reflectance standards independently. The Landsat 8 OLI reflectance calibration is considered to be most accurate. To improve radiometric calibration accuracy of historical data, Landsat 1-7 sensors also need to be cross-calibrated to the OLI reflectance scale. Results of that effort, as well as other calibration updates including the absolute and relative radiometric calibration and saturated pixel replacement for Landsat 8 OLI and absolute calibration for Landsat 4 and 5 Thematic Mappers (TM), will be implemented into Landsat products during the archive reprocessing campaign planned within the new collection management strategy. This paper reports on the planned radiometric calibration updates to the solar reflective bands of the new Landsat collection.

Conference Paper↗

Landsat-8 Operational Land Imager (OLI) radiometric performance on-orbit

Expectations of the Operational Land Imager (OLI) radiometric performance onboard Landsat-8 have been met or exceeded. The calibration activities that occurred prior to launch provided calibration parameters that enabled ground processing to produce imagery that met most requirements when data were transmitted to the ground. Since launch, calibration updates have improved the image quality even more, so that all requirements are met. These updates range from detector gain coefficients to reduce striping and banding to alignment parameters to improve the geometric accuracy. This paper concentrates on the on-orbit radiometric performance of the OLI, excepting the radiometric calibration performance. Topics discussed in this paper include: signal-to-noise ratios that are an order of magnitude higher than previous Landsat missions; radiometric uniformity that shows little residual banding and striping, and continues to improve; a dynamic range that limits saturation to extremely high radiance levels; extremely stable detectors; slight nonlinearity that is corrected in ground processing; detectors that are stable and 100% operable; and few image artifacts.

Remote Sensing↗

On-orbit performance of the Landsat 8 Operational Land Imager

The Landsat 8 satellite was launched on February 11, 2013, to systematically collect multispectral images for detection and quantitative analysis of changes on the Earth’s surface. The collected data are stored at the U.S. Geological Survey (USGS) Earth Resources Observation and Science (EROS) Center and continue the longest archive of medium resolution Earth images. There are two imaging instruments onboard the satellite: the Operational Land Imager (OLI) and the Thermal InfraRed Sensor (TIRS). This paper summarizes radiometric performance of the OLI including the bias stability, the system noise, saturation and other artifacts observed in its data during the first 1.5 years on orbit. Detector noise levels remain low and Signal-To-Noise Ratio high, largely exceeding the requirements. Impulse noise and saturation are present in imagery, but have negligible effect on Landsat 8 products. Oversaturation happens occasionally, but the affected detectors quickly restore their nominal responsivity. Overall, the OLI performs very well on orbit and provides high quality products to the user community. © (2014) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.

Conference Paper↗

Landsat 4 Thematic Mapper calibration update

The Landsat 4 Thematic Mapper (TM) collected imagery of the Earth's surface from 1982 to 1993. Although largely overshadowed by Landsat 5 which was launched in 1984, Landsat 4 TM imagery extends the TM-based record of the Earth back to 1982 and also substantially supplements the image archive collected by Landsat 5. To provide a consistent calibration record for the TM instruments, Landsat 4 TM was cross-calibrated to Landsat 5 using nearly simultaneous overpass imagery of pseudo-invariant calibration sites (PICS) in the time period of 1988-1990. To determine if the radiometric gain of Landsat 4 had changed over its lifetime, time series from two PICS locations (a Saharan site known as Libya 4 and a site in southwest North America, commonly referred to as the Sonoran Desert site) were developed. The results indicated that Landsat 4 had been very stable over its lifetime, with no discernible degradation in sensor performance in all reflective bands except band 1. In contrast, band 1 exhibited a 12% decay in responsivity over the lifetime of the instrument. Results from this paper have been implemented at USGS EROS, which enables users of Landsat TM data sets to obtain consistently calibrated data from Landsat 4 and 5 TM as well as Landsat 7 ETM+ instruments.

IEEE Transactions on Geoscience and Remote Sensing↗

Landsat 8 on-orbit characterization and calibration system

The Landsat Data Continuity Mission (LDCM) is planning to launch the Landsat 8 satellite in December 2012, which continues an uninterrupted record of consistently calibrated globally acquired multispectral images of the Earth started in 1972. The satellite will carry two imaging sensors: the Operational Land Imager (OLI) and the Thermal Infrared Sensor (TIRS). The OLI will provide visible, near-infrared and short-wave infrared data in nine spectral bands while the TIRS will acquire thermal infrared data in two bands. Both sensors have a pushbroom design and consequently, each has a large number of detectors to be characterized. Image and calibration data downlinked from the satellite will be processed by the U.S. Geological Survey (USGS) Earth Resources Observation and Science (EROS) Center using the Landsat 8 Image Assessment System (IAS), a component of the Ground System. In addition to extracting statistics from all Earth images acquired, the IAS will process and trend results from analysis of special calibration acquisitions, such as solar diffuser, lunar, shutter, night, lamp and blackbody data, and preselected calibration sites. The trended data will be systematically processed and analyzed, and calibration and characterization parameters will be updated using both automatic and customized manual tools. This paper describes the analysis tools and the system developed to monitor and characterize on-orbit performance and calibrate the Landsat 8 sensors and image data products.

Conference Paper↗

Operational calibration and validation of landsat data continuity mission (LDCM) sensors using the image assessment system (IAS)

Systematic characterization and calibration of the Landsat sensors and the assessment of image data quality are performed using the Image Assessment System (IAS). The IAS was first introduced as an element of the Landsat 7 (L7) Enhanced Thematic Mapper Plus (ETM+) ground segment and recently extended to Landsat 4 (L4) and 5 (L5) Thematic Mappers (TM) and Multispectral Sensors (MSS) on-board the Landsat 1-5 satellites. In preparation for the Landsat Data Continuity Mission (LDCM), the IAS was developed for the Earth Observer 1 (EO-1) Advanced Land Imager (ALI) with a capability to assess pushbroom sensors. This paper describes the LDCM version of the IAS and how it relates to unique calibration and validation attributes of its on-board imaging sensors. The LDCM IAS system will have to handle a significantly larger number of detectors and the associated database than the previous IAS versions. An additional challenge is that the LDCM IAS must handle data from two sensors, as the LDCM products will combine the Operational Land Imager (OLI) and Thermal Infrared Sensor (TIRS) spectral bands.

Conference Paper↗

Landsat 5 Thematic Mapper (TM) recalibration procedure for data processed using the National Landsat Archive Production System (NLAPS)

The multispectral data from the Landsat 5 (L5) Thematic Mapper (TM) sensor provides the backbone of an extensive archive of moderate resolution Earth imagery. Even after more than 24 years of service, the L5 TM is still operational. Given the longevity of the instrument, the detectors have aged, and the system's radiometric characteristics have changed since launch. The calibration procedures and parameters in National Land Archive Production System (NLAPS) have also changed with time. Revised radiometric calibrations in 2003 and 2007 have improved the radiometric accuracy of recently processed data; however, users with data processed prior to the calibration update have not benefited from these revisions. A general procedure has been developed to give users the ability to recalibrate their existing systematically corrected (Level-1) products. The best recalibration can be obtained if the work order report originally used in product generation is still available. This paper discusses the procedure to recalibrate the L5 TM data for the users who have the work order files that were delivered with their products.

Conference Paper↗