Geology Reports⌕ Search

Geology topics

D.A. Vroblesky

Publications and source records attributed to D.A. Vroblesky.

At least 19 recordsLinked to original sources

Phytoscreening for chlorinated solvents using rapid in vitro SPME sampling: Application to urban plume in Verl, Germany

Rapid detection and delineation of contaminants in urban settings is critically important in protecting human health. Cores from trees growing above a plume of contaminated groundwater in Verl, Germany, were collected in 1 day, with subsequent analysis and plume mapping completed over several days. Solid-phase microextraction (SPME) analysis was applied to detect tetrachloroethene (PCE) and trichloroethene (TCE) to below nanogram/liter levels in the transpiration stream of the trees. The tree core concentrations showed a clear areal correlation to the distribution of PCE and TCE in the groundwater. Concentrations in tree cores were lower than the underlying groundwater, as anticipated; however, the tree core water retained the PCE:TCE signature of the underlying groundwater in the urban, populated area. The PCE:TCE ratio can indicate areas of differing degradation activity. Therefore, the phytoscreening analysis was capable not only of mapping the spatial distribution of groundwater contamination but also of delineating zones of potentially differing contaminant sources and degradation. The simplicity of tree coring and the ability to collect a large number of samples in a day with minimal disruption or property damage in the urban setting demonstrates that phytoscreening can be a powerful tool for gaining reconnaissance-level information on groundwater contaminated by chlorinated solvents. The use of SPME decreases the detection level considerably and increases the sensitivity of phytoscreening as an assessment, monitoring, and phytoforensic tool. With rapid, inexpensive, and noninvasive methods of detecting and delineating contaminants underlying homes, as in this case, human health can be better protected through screening of broader areas and with far faster response times.

Environmental Science & Technology↗

Phytoforensics, dendrochemistry, and phytoscreening: New green tools for delineating contaminants from past and present

As plants evolved to be extremely proficient in mass transfer with their surroundings and survive as earth’s dominant biomass, they also accumulate and store some contaminants from surroundings, acting as passive samplers. Novel applications and analytical methods have been utilized to gain information about a wide range of contaminants in the biosphere soil, water, and air, with information available on both past (dendrochemistry) and present (phytoscreening). Collectively these sampling approaches provide rapid, cheap, ecologically friendly, and overall “green” tools termed “Phytoforensics”.

Environmental Science & Technology↗

Sewers as a source and sink of chlorinated-solvent groundwater contamination, Marine Corps Recruit Depot, Parris Island, South Carolina

Groundwater contamination by tetrachloroethene and its dechlorination products is present in two partially intermingled plumes in the surficial aquifer near a former dry‐cleaning facility at Site 45, Marine Corps Recruit Depot, Parris Island, South Carolina. The northern plume originates from the vicinity of former above‐ground storage tanks. Free‐phase tetrachloroethene from activities in this area entered the groundwater. The southern plume originates at a nearby, new dry‐cleaning facility, but probably was the result of contamination released to the aquifer from a leaking sanitary sewer line from the former dry‐cleaning facility. Discharge of dissolved groundwater contamination is primarily to leaking storm sewers below the water table. The strong influence of sanitary sewers on source distribution and of storm sewers on plume orientation and discharge at this site indicates that groundwater‐contamination investigators should consider the potential influence of sewer systems at their sites.

South Carolina↗

Ground water chlorinated ethenes in tree trunks: Case studies, influence of recharge, and potential degradation mechanism

Trichloroethene (TCE) was detected in cores of trees growing above TCE-contaminated ground at three sites: the Carswell Golf Course in Texas, Air Force Plant PJKS in Colorado, and Naval Weapons Station Charleston in South Carolina. This was true even when the depth to water was 7.9 m or when the contaminated aquifer was confined beneath ∼3 m of clay. Additional ground water contaminants detected in the tree cores were cis -1,2-dichloroethene at two sites and tetrachloroethene at one site. Thus, tree coring can be a rapid and effective means of locating shallow subsurface chlorinated ethenes and possibly identifying zones of active TCE dechlorination. Tree cores collected over time were useful in identifying the onset of ground water contamination. Several factors affecting chlorinated ethene concentrations in tree cores were identified in this investigation. The factors include ground water chlorinated ethene concentrations and depth to ground water contamination. In addition, differing TCE concentrations around the trunk of some trees appear to be related to the roots deriving water from differing areas. Opportunistic uptake of infiltrating rainfall can dilute prerain TCE concentrations in the trunk. TCE concentrations in core headspace may differ among some tree species. In some trees, infestation of bacteria in decaying heartwood may provide a TCE dechlorination mechanism within the trunk.

Ground Water Monitoring and Remediation↗

Influence of dissolved oxygen convection on well sampling

Convective transport of dissolved oxygen (D.O.) from shallow to deeper parts of wells was observed as the shallow water in wells in South Carolina became cooler than the deeper water in the wells due to seasonal changes. Wells having a relatively small depth to water were more susceptible to thermally induced convection than wells where the depth to water was greater because the shallower water levels were more influenced by air temperature. The potential for convective transport of D.O. to maintain oxygenated conditions in a well screened in an anaerobic aquifer was diminished as ground water exchange through the well screen increased and as oxygen demand increased. Transport of D.O. to the screened interval can adversely affect the ability of passive samplers to produce accurate concentrations of oxygen-sensitive solutes such as iron, other redox indicators, and microbiological data. A comparison of passive sampling to low-flow sampling in a well undergoing convection, however, showed general agreement of volatile organic compound concentrations. During low-flow sampling, the pumped water may be a mixture of convecting water from within the well casing and aquifer water moving inward through the screen. This mixing of water during low-flow sampling can substantially increase equilibration times, can cause false stabilization of indicator parameters, can give false indications of the redox state, and can provide microbiological data that are not representative of the aquifer conditions. Data from this investigation show that simple in-well devices can effectively mitigate convective transport of oxygen. The devices can range from inflatable packers to simple, inexpensive baffle systems. ?? 2007 National Ground Water Association.

Ground Water Monitoring and Remediation↗

The effect of terrace geology on ground-water movement and on the interaction of ground water and surface water on a mountainside near Mirror Lake, New Hampshire, USA

The west watershed of Mirror Lake in the White Mountains of New Hampshire contains several terraces that are at different altitudes and have different geologic compositions. The lowest terrace (FSE) has 5 m of sand overlying 9 m of till. The two next successively higher terraces (FS2 and FS1) consist entirely of sand and have maximum thicknesses of about 7 m. A fourth, and highest, terrace (FS3) lies in the north-west watershed directly adjacent to the west watershed. This highest terrace has 2 m of sand overlying 8 m of till. All terraces overlie fractured crystalline bedrock. Numerical models of hypothetical settings simulating ground-water flow in a mountainside indicated that the presence of a terrace can cause local ground-water flow cells to develop, and that the flow patterns differ based on the geologic composition of the terrace. For example, more ground water moves from the bedrock to the glacial deposits beneath terraces consisting completely of sand than beneath terraces that have sand underlain by till. Field data from Mirror Lake watersheds corroborate the numerical experiments. The geology of the terraces also affects how the stream draining the west watershed interacts with ground water. The stream turns part way down the mountainside and passes between the two sand terraces, essentially transecting the movement of ground water down the valley side. Transects of water-table wells were installed across the stream's riparian zone above, between, and below the sand terraces. Head data from these wells indicated that the stream gains ground water on both sides above and below the sand terraces. However, where it flows between the sand terraces the stream gains ground water on its uphill side and loses water on its downhill side. Biogeochemical processes in the riparian zone of the flow-through reach have resulted in anoxic ground water beneath the lower sand terrace. Results of this study indicate that it is useful to understand patterns of ground-water flow in order to fully understand the flow and chemical characteristics of both ground water and surface water in mountainous terrain.

Hydrological Processes↗

Temporal changes in VOC discharge to surface water from a fractured rock aquifer during well installation and operation, Greenville, South Carolina

Analysis of the vapor in passive vapor samplers retrieved from a streambed in fractured rock terrain implied that volatile organic carbon (VOC) discharge from ground water to surface water substantially increased following installation of a contaminant recovery well using air rotary drilling. The air rotary technique forced air into the aquifer near the stream. The injection produced an upward hydraulic gradient that appears to have transported water and contaminants from deeper parts of the aquifer through fractures into shallow parts of the aquifer. Once in the shallow flow regime, the contamination was transported to the stream, where it discharged during the next several weeks following well installation. After the recovery well was activated and began continuously pumping contaminated ground water to a treatment facility, the VOC concentrations in the stream bottom passive vapor samplers decreased to below detectable concentrations, suggesting that the withdrawal had captured the contaminated ground water that previously had discharged to the stream.

South Carolina↗

Locating VOC contamination in a fractured-rock aquifer at the ground-water/surface-water interface using passive vapor collectors

Chlorinated organic solvents introduced to unlined lagoons at an industrial waste-water treatment plant in the Inner Piedmont of South Carolina resulted in ground-water contamination of a fractured-rock aquifer. Part of the ground-water contamination discharges to Little Rocky Creek, downgradient from the waste-water treatment plant. Passive vapor collectors were buried in the bottom sediment of the creek to locate areas where ground water contaminated with volatile organic compounds was discharging to the creek. High concentrations of volatile organic compounds (VOCs) were found in passive vapor collectors in an area where VOCs were known to be discharging from ground water to surface water. This area was also a site where very low frequency electromagnetic anomalies (interpreted as fracture zones) intersected the creek or converged near the creek. The data show that passive vapor collectors in bottom sediment of Little Rocky Creek provided information on the location of fractures that were discharging contaminated ground water to surface water.

Groundwater↗

Measuring rates of biodegradation in a contaminated aquifer using field and laboratory methods

Rates of biodegradation were measured in a petroleum hydrocarbon-contaminated aquifer using a combination of field and laboratory methods. These methods are based on tracking concentration changes of substrates (both electron donors and acceptors) or final products of microbial metabolism over time. Ground water at the study site (Hanahan, South Carolina) is anoxic, and sulfate reduction is the predominant terminal electron accepting process. Laboratory studies conducted with sediment cored from the site showed that 14 C-toluene was mineralized to 14 CO 2 with a first-order degradation rate constant (k tol ) of -0.01 d −1 under sulfate-reducing conditions. Under nitrate-amended, Fe(III)-amended, or nonamended (methanogenic) conditions, toluene was not significantly mineralized. 14 C-Benzene was degraded at low but measurable rates (k ben = -0.003 d −1 ) under sulfate-reducing conditions whereas degradation under methanogenic conditions was negligible. These results illustrate the extreme sensitivity of laboratory-measured biodegradation rates to terminal electron-accepting conditions, and show the necessity of carefully matching experimental conditions to in situ conditions. Concentration decreases of toluene along aquifer flowpaths, when the uncertainty of ground-water flow velocities was considered, indicated k tol values ranging from -0.0075 to -0.03 d −1 . Concentration decreases of sulfate and concentration increases of dissolved inorganic carbon (DIC), when normalized for assumed stoichiometric oxidation of toluene coupled to sulfate reduction, yielded a k so4 range of -0.005 to -0.02 d −1 , and a k DIC value range of +0.00075 to +0.003 d −1 . Because both laboratory and field methods have numerous sources of uncertainty, a combination of these methods is the most appropriate procedure for evaluating biodegradation rate constants in contaminated ground-water systems.

Groundwater↗

Determination of the relative uptake of ground vs. surface water by Populus deltoides during phytoremediation

The use of plants to remediate polluted groundwater is becoming an attractive alternative to more expensive traditional techniques. In order to adequately assess the effectiveness of the phytoremediation treatment, a clear understanding of water-use habits by the selected plant species is essential. We examined the relative uptake of surface water (i.e., precipitation) vs. groundwater by mature Populus deltoides by applying irrigation water at a rate equivalent to a 5-cm rain event. We used stable isotopes of hydrogen (D) and oxygen (18O) to identify groundwater and surface water (irrigation water) in the xylem sap water. Pretreatment isotopic ratios of both deuterium and 18O, ranked from heaviest to lightest, were irrigation water > groundwater > xylem sap. The discrepancy in preirrigation isotopic signatures between groundwater and xylem sap suggests that in the absence of a surface source of water (i.e., between rain events) there is an unknown amount of water being extracted from sources other than groundwater (i.e., soil surface water). We examined changes in volumetric soil water content (%), total hourly sapflux rates, and trichloroethene (TCE) concentrations. Following the irrigation treatment, volumetric soil water increased by 86% and sapflux increased by as much as 61%. Isotopic signatures of the xylem sap became substantially heavier following irrigation, suggesting that the applied irrigation water was quickly taken up by the plants. TCE concentrations in the xylem sap were diluted by an average of 21% following irrigation; however, dilution was low relative to the increase in sapflux. Our results show that water use by Populus deltoides is variable. Hence, studies addressing phytoremediation effectiveness must account for the relative proportion of surface vs. groundwater uptake.

International Journal of Phytoremediation↗

Considerations for sampling inorganic constituents in ground water using diffusion samplers

Data indicate that nylon-screen and dialysis diffusion samplers are capable of obtaining concentrations of inorganic solutes in ground water from wells that closely correspond to concentrations obtained by low-flow sampling. Conservative solutes, such as chloride, can be sampled by filling the diffusion samplers with oxygenated water. The samplers should be filled with anaerobic water for sampling redoxsensitive solutes. Oxidation of iron within the samplers, either by using aerobic fill water or by in-well oxygenation events, can lead to erroneous iron concentrations. Lithologic and chemical heterogeneity and sampler placement depth can lead to differences between concentrations from diffusion samples and low-flow samples because of mixing during pumping. A disadvantage of regenerated cellulose dialysis samplers is that they can begin to biodegrade within the two weeks of deployment. Nylon-screen samplers buried beneath streambed sediment along the unnamed tributary in a discharge zone of arseniccontaminated ground water were useful in locating the specific discharge zone.

Conference Paper↗

Equilibration times, compound selectivity, and stability of diffusion samplers for collection of ground-water VOC concentrations

Vapor-filled polyethylene diffusion samplers (typically used to locate discharge zones of volatile organic compound contaminated ground water beneath streams and lakes) and water-filled polyethylene diffusion bag samplers (typically used to obtain volatile organic compound concentrations in ground-water at wells) were tested to determine compound selectivity, equilibration times, and sample stability. The aqueous concentrations of several volatile organic compounds obtained from within water-filled diffusion samplers closely matched concentrations in ambient water outside the samplers. An exception was methyl-tert-butyl ether, which was detectable, but not reliably quantifiable using the diffusion samplers. The samplers equilibrated to a variety of volatile organic compounds within 24 h for vapor-filled passive diffusion vial samplers and within 48 h for water-filled passive diffusion bag samplers. Under field conditions, however, a longer equilibration time may be required to account for environmental disturbances caused by sampler deployment. An equilibrium period for both vapor- and water-filled diffusion samplers of approximately 2 weeks probably is adequate for most investigations in sandy formations. Longer times may be required for diffusion-sampler equilibration in poorly permeable sediment. The vapor-filled samplers should be capped and water from the diffusion bag samplers should be transferred to sampling vials immediately upon recovery to avoid volatilization losses of the gasses. ?? 2001 Elsevier Science Ltd.

Advances in Environmental Research↗

Biophysical mechanisms of trichloroethene uptake and loss in baldcypress growing in shallow contaminated groundwater

Wetland vegetation may be useful in the remediation of shallow contaminated aquifers. Mesocosm experiments were conducted to describe the regulatory mechanisms affecting trichloroethene (TCE) removal rates from groundwater by flood-adapted wetland trees at a contaminated site. TCE flux through baldcypress [Taxodium distichum (L) Rich] seedlings grown in glass- carboys decreased from day to night and from August to December. The diel fluctuation coincided with changes in leaf-level physiology, as the daytime flux was significantly correlated with net photosynthesis but not with respiration at night. A decrease in seedling water use from summer to winter explained the large seasonal difference in TCE flux. A simple model that simulates gas-phase diffusion through aerenchyma tested the importance of diffusion of TCE vapor from roots to the stem. The modeled diffusive flux was within 64% of the observed value during the winter but could only explain 8% of the summer flux. Seedling water use was a good estimator of flux during the summer. Hence, evapotranspiration (ET) in the summer may serve as a good predictor for the potential of TCE removal by baldcypress trees, while diffusive flux may better approximate potential contaminant loss in the winter.Wetland vegetation may be useful in the remediation of shallow contaminated aquifers. Mesocosm experiments were conducted to describe the regulatory mechanisms affecting trichloroethene (TCE) removal rates from groundwater by flood-adapted wetland trees at a contaminated site. TCE flux through baldcypress [Taxodium distichum (L) Rich] seedlings grown in glass-carboys decreased from day to night and from August to December. The diel fluctuation coincided with changes in leaf-level physiology, as the daytime flux was significantly correlated with net photosynthesis but not with respiration at night. A decrease in seedling water use from summer to winter explained the large seasonal difference in TCE flux. A simple model that simulates gas-phase diffusion through aerenchyma tested the importance of diffusion of TCE vapor from roots to the stem. The modeled diffusive flux was within 64% of the observed value during the winter but could only explain 8% of the summer flux. Seedling water use was a good estimator of flux during the summer. Hence, evapotranspiration (ET) in the summer may serve as a good predictor for the potential of TCE removal by baldcypress trees, while diffusive flux may better approximate potential contaminant loss in the winter.

Environmental Science & Technology↗

Practical considerations for measuring hydrogen concentrations in groundwater

Several practical considerations for measuring concentrations of dissolved molecular hydrogen (H2) in groundwater including 1 sampling methods 2 pumping methods and (3) effects of well casing materials were evaluated. Three different sampling methodologies (a downhole sampler, a gas- stripping method, and a diffusion sampler) were compared. The downhole sampler and gas-stripping methods gave similar results when applied to the same wells, the other hand, appeared to The diffusion sampler, on overestimate H2 concentrations relative to the downhole sampler. Of these methods, the gas-stripping method is better suited to field conditions because it is faster (~ 30 min for a single analysis as opposed to 2 h for the downhole sampler or 8 h for the diffusion sampler), the analysis is easier (less sample manipulation is required), and the data computations are more straightforward (H2 concentrations need not be corrected for water sample volume). Measurement of H2 using the gas-stripping method can be affected by different pumping equipment. Peristaltic, piston, and bladder pumps all gave similar results when applied to water produced from the same well. It was observed, however, that peristaltic-pumped water (which draws water under a negative pressure) enhanced the gas-stripping process and equilibrated slightly faster than either piston or bladder pumps (which push water under a positive pressure). A direct current(dc) electrically driven submersible pump was observed to produce H2 and was not suitable for measuring H2 in groundwater. Measurements from two field sites indicate that iron or steel well casings, produce H2, which masks H2 concentrations in groundwater. PVC-cased wells or wells cased with other materials that do not produce H2 are necessary for measuring H2 concentrations in groundwater.Several practical considerations for measuring concentrations of dissolved molecular hydrogen in groundwater including sampling methods, pumping methods, and effects of well casing materials were evaluated. The downhole sampler and gas-stripping methods gave similar results when applied to the same wells. The diffusional sampler appears to overestimate H2 concentrations relative to the downhole sampler. Gas-stripping method is better for a single analysis and the data computations are more straightforward. Measurement of H2 using the gas-stripping method can be affected by different pumping equipment.

Environmental Science & Technology↗

Lack of correlation between organic acid concentrations and predominant electron-accepting processes in a contaminated aquifer

Long-term (1992-1995) monitoring data from a petroleum hydrocarbon- contaminated aquifer were used to examine the hypothesis that concentrations of low molecular weight (LMW) aliphatic organic acids reflect terminal electron-accepting processes. During the period of study, concentrations of dissolved hydrogen (H2) indicated that methanogenic, sulfate-reducing, and iron(III)-reducing conditions predominated at the site. However, there was no correlation between LMW organic acid concentrations and concentrations of dissolved H2. These results indicate that organic acid concentrations are not a reliable indicator of local redox conditions at this site.

Environmental Science & Technology↗

Water-quality, water-level, and lake-bottom-sediment data collected from the defense fuel supply point and adjacent properties, Hanahan, South Carolina, 1990-96

A 9-year scientific investigation to determine the potential for biore-mediation of ground-water contamination and to monitor the effectiveness of an engineered bioremediation system located at the Defense Fuel Supply Point and adjacent properties in Hanahan, S.C., has culminated in the collection of abundant water-quality and water-level data.This report presents the analytical results of the study that monitored the changes in surface- and ground-water quality and water-table elevations in the study area from December 1990 to January 1996. This report also presents analytical results of lake-bottom sediments collected in the study area.

South Carolina↗