Geology Reports⌕ Search

SEARCH · Geology Reports

Results for “Geostandards and Geoanalytical Research”

Search indexed USGS publications on groundwater, aquifers, geologic maps, mineral resources and earthquakes. Explore source records by subject and place.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

18 recordsLinked to original sources

GSD-1G and MPI-DING Reference Glasses for In Situ and Bulk Isotopic Determination

This paper contains the results of an extensive isotopic study of United States Geological Survey GSD-1G and MPI-DING reference glasses. Thirteen different laboratories were involved using high-precision bulk (TIMS, MC-ICP-MS) and microanalytical (LA-MC-ICP-MS, LA-ICP-MS) techniques. Detailed studies were performed to demonstrate the large-scale and small-scale homogeneity of the reference glasses. Together with previously published isotopic data from ten other laboratories, preliminary reference and information values as well as their uncertainties at the 95% confidence level were determined for H, O, Li, B, Si, Ca, Sr, Nd, Hf, Pb, Th and U isotopes using the recommendations of the International Association of Geoanalysts for certification of reference materials. Our results indicate that GSD-1G and the MPI-DING glasses are suitable reference materials for microanalytical and bulk analytical purposes. Ce document contient les r??sultats d'une importante ??tude isotopique des verres de r??f??rence USGS GSD-1G et MPI-DING. Treize laboratoires diff??rents ont particip?? au travers de techniques analytiques de haute pr??cision travaillant soit sur ??chantillon total (TIMS, MC-ICP-MS) soit par microanalyse ??in situ?? (LA-MC-ICP-MS, LA-ICP-MS). ?? 2010 The Authors. Geostandards and Geoanalytical Research ?? 2010 International Association of Geoanalysts.

Geostandards and Geoanalytical Research↗

Statistical perspective on the petrologic utility of polyphase groundmass compositions inferred via defocused beam electron probe microanalysis

Polyphase groundmasses (micro-scale minerals with or without glass) are generated from silicate liquids during the cooling of natural lavas often alongside larger minerals formed long before eruption. Many researchers have posited that compositions gleaned from the analysis of groundmasses closely approximate the compositions of the melts they were derived from, and these have been used frequently to model pre-eruptive magma conditions. However, it is difficult to confidently identify and sample these groundmasses once they are formed. Using a sample of lava that exhibits a wide degree of textural variation (ranging from holocrystalline to hypohyaline) we show that compositions of groundmasses sampled using defocused electron beams are significantly different from glass compositions in terms of mean composition and covariance. Despite this, several groundmass compositions qualify as ‘in equilibrium’ with matrix/rim olivine. When processed using available thermometers, however, modelled equilibrium temperatures are significantly higher than those produced using glass data, on average. Because of this, we prescribe caution in using polyphase groundmass data generated using defocused beam analysis even as a rudimentary approach.

Geostandards and Geoanalytical Research↗

Antarctic ice-core water (USGS49) – A new isotopic reference material for δ2H and δ18O measurements of water

As a result of the scarcity of isotopic reference waters for daily use, a new secondary isotopic reference material for international distribution has been prepared from ice-core water from the Amundsen–Scott South Pole Station. This isotopic reference material, designated as USGS49, was filtered, homogenised, loaded into glass ampoules, sealed with a torch, autoclaved to eliminate biological activity and measured by dual-inlet isotope-ratio mass spectrometry. The δ 2 H and δ 18 O values of USGS49 are −394.7 ± 0.4 and −50.55 ± 0.04 mUr (where mUr = 0.001 = ‰), respectively, relative to VSMOW, on scales normalised such that the δ 2 H and δ 18 O values of SLAP reference water are, respectively, −428 and −55.5 mUr. Each uncertainty is an estimated expanded uncertainty ( U = 2 u c ) about the reference value that provides an interval that has about a 95% probability of encompassing the true value. This isotopic reference material is intended as one of two isotopic reference waters for daily normalisation of stable hydrogen and oxygen isotopic analysis of water with an isotope-ratio mass spectrometer or a laser absorption spectrometer. It is available by the case of 144 glass ampoules or as a set of sixteen glass ampoules containing 5 ml of water in each ampoule.

Geostandards and Geoanalytical Research↗

Instrumentation development for In Situ 40Ar/39Ar planetary geochronology

The chronology of the Solar System, particularly the timing of formation of extra-terrestrial bodies and their features, is an outstanding problem in planetary science. Although various chronological methods for in situ geochronology have been proposed (e.g., Rb-Sr, K-Ar), and even applied (K-Ar), the reliability, accuracy, and applicability of the 40 Ar/ 39 Ar method makes it by far the most desirable chronometer for dating extra-terrestrial bodies. The method however relies on the neutron irradiation of samples, and thus a neutron source. Herein, we discuss the challenges and feasibility of deploying a passive neutron source to planetary surfaces for the in situ application of the 40 Ar/ 39 Ar chronometer. Requirements in generating and shielding neutrons, as well as analysing samples are described, along with an exploration of limitations such as mass, power and cost. Two potential solutions for the in situ extra-terrestrial deployment of the 40 Ar/ 39 Ar method are presented. Although this represents a challenging task, developing the technology to apply the 40 Ar/ 39 Ar method on planetary surfaces would represent a major advance towards constraining the timescale of solar system formation and evolution.

Geostandards and Geoanalytical Research↗

Trace element characterisation of MAD‐559 zircon reference material for ion microprobe analysis

We document the composition of a natural zircon gemstone sourced from Madagascar, MAD‐559 – a new reference material for calibrating trace element mass fractions in zircon measured by SIMS. The composition of MAD‐559 was quantified by calibration relative to the well‐documented zircon reference material 91500, for which we compiled existing published data (Mg, Al, Y, rare earth elements, Hf, U, Th) and performed new measurements to characterise the mass fraction of less commonly measured elements (Li, Be, B, F, Na, P, K, Ca, Sc, Ti, Fe, Nb). Measurement results of SL13, CZ3 and MAD‐1 zircons and NIST SRM glasses were performed as quality control materials to test measurement bias and repeatability. We show the intermediate precision for most trace element measurement results of MAD‐559 to be between ± 3% and ± 5% RSD based on 139 measurements by SIMS on twenty‐five individual polished zircon chips measured during a 24‐h period, as well as repeat measurements performed over five separate analytical sessions. Trace element mass fractions were also measured by LA‐ICP‐MS in two different laboratories, and major element compositions measured by electron microprobe, to compare with results measured by SIMS. Based on laser Raman and hyperspectral cathodoluminescence spectroscopy, we show MAD‐559 to have high crystal disorder due to radiation damage relative to crystalline zircon (e.g., SL13 and 91500 zircon). Although the high cumulative alpha dose of MAD‐559 zircon makes it a poor reference material for geochronology, the consistency of the trace element mass fraction results measured in multiple sessions and by various measurement methods shows that it is an ideal reference material for microanalytical trace element mass fraction quantification of zircon.

Geostandards and Geoanalytical Research↗

GHR1 Zircon – A new Eocene natural reference material for microbeam U-Pb geochronology and Hf isotopic analysis of zircon

We present multitechnique U-Pb geochronology and Hf isotopic data from zircon separated from rapakivi biotite granite within the Eocene Golden Horn batholith in Washington, USA. A weighted mean of twenty-five Th-corrected 206 Pb/ 238 U zircon dates produced at two independent laboratories using chemical abrasion-isotope dilution-thermal ionisation mass spectrometry (CA-ID-TIMS) is 48.106 ± 0.023 Ma (2 s analytical including tracer uncertainties, MSWD = 1.53) and is our recommended date for GHR1 zircon. Microbeam 206 Pb/ 238 U dates from laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) and secondary ion mass spectrometry (SIMS) laboratories are reproducible and in agreement with the CA-ID-TIMS date to within < 1.5%. Solution multi-collector ICP-MS (MC-ICP-MS) measurements of Hf isotopes from chemically purified aliquots of GHR1 yield a mean 176 Hf/ 177 Hf of 0.283050 ± 17 (2 s , n = 10), corresponding to a εHf 0 of +9.3. Hafnium isotopic measurements from two LA-ICP-MS laboratories are in agreement with the solution MC-ICP-MS value. The reproducibility of 206 Pb/ 238 U and 176 Hf/ 177 Hf ratios from GHR1 zircon across a variety of measurement techniques demonstrates their homogeneity in most grains. Additionally, the effectively limitless reserves of GHR1 material from an accessible exposure suggest that GHR1 can provide a useful reference material for U-Pb geochronology of Cenozoic zircon and Hf isotopic measurements of zircon with radiogenic 176 Hf/ 177 Hf.

Geostandards and Geoanalytical Research↗

Direct trace element determination in oil and gas produced waters with inductively coupled plasma - Optical emission spectrometry (ICP-OES): Advantages of high salinity tolerance

Waters co-produced during petroleum extraction are the largest waste stream from oil and gas development. Reuse or disposal of these waters is difficult due to their high salinities and the sheer volumes generated. Produced waters may also contain valuable mineral commodities. While an understanding of produced water trace element composition is required for evaluating the associated resource and waste potential of these materials, measuring trace elements in brines is challenging due to the dilution requirements of typical methods. Alternatively, inductively coupled plasma-optical emission spectrometry (ICP-OES) has shown promise as being capable of direct measurements of trace elements within produced waters with minimal dilution. Here we evaluate direct ICP-OES trace element quantification in produced waters for 17 trace elements (As, Al, Ba, Be, Cd, Cr, Co, Cu, Hg, Mo, Ni, Pb, Rb, Sb, U, V, and Zn) within 15 produced waters from five U.S. continuous reservoirs. The ICP-OES results are compared against trace element levels determined using inductively coupled plasma-mass spectrometry from the same samples. Our results demonstrate the potential for direct analysis of high salinity waters using ICP-OES with minimal dilution and provide trace element concentrations in waters from several important U.S. petroleum-generating reservoirs where available data is sparse.

Montana, New York, North Dakota, Ohio, Pennsylvani↗

Evaluating the utility of principal component analysis on EDS x-ray maps to determine bulk mineralogy

Due to advances in EDS technology, electron microscopy techniques have become an important tool to determine the relative abundance of mineral phases. However, few studies have directly compared EDS X‐ray mineralogy with traditional techniques for assessing bulk mineralogy and elemental composition. We show that analysing a limited area (~ 0.5–3.2 mm 2 ) of fine‐grained metal extraction samples using EDS X‐ray principal component analysis phase mapping yields results that agree within 10% with more traditional techniques for mineral phases present at greater than 5% m / m . Electron beam sensitive minerals, such as the carbonates, have poor correlations between EDS and X‐ray Diffraction (XRD) and/or WD‐XRF. Likewise, poor correlations between methods can be expected for particles that are smaller than the interaction volume of the electron beam (~ 1.5 µm); this strongly affected the phyllosilicates. One strength of EDS phase mapping is that it can identify phases present below the detection limit of powder XRD (< 1%). Our results demonstrate that EDS phase mapping is sufficient to estimate bulk sample mineralogy. If polished thin sections have been prepared, this approach may save time and/or money relative to the more traditional approaches of preparing separate subsamples for XRD and/or WD‐XRF.

Geostandards and Geoanalytical Research↗

First principles calibration of 40Ar abundances in 40Ar/39Ar mineral neutron fluence monitors: Methodology and preliminary results

The accuracy and traceability of geochronometers are of vital importance to questions asked by many Earth scientists. The widely applied 40 Ar/ 39 Ar geochronometer relies on the co-irradiation of samples with neutron fluence monitors (reference materials) of known ages; the ages and uncertainties of these monitors are critical to our ability to apply this chronometer. Previously, first principles, astronomical and optimisation calibrations have been made. The first principles method for determining the age of monitor minerals is the K-Ar method, which involves measurement of their 40 K and 40 Ar* abundances. The AQuA (Absolute Quantities of Argon) pipette system, which emits calibrated quantities of 40 Ar* via the ideal gas law, was used to calibrate the sensitivity of the system across a range of source pressures and estimate 40 Ar* abundances in neutron fluence monitors. These 40 Ar abundances were combined with existing 40 K abundance data for these monitors. Ages for HD-B1 and MD2 (GA1550) biotite fluence monitors were calculated and combined with intercalibration data for HD-B1 and Fish Canyon sanidine (FCs) to determine ages for FCs. Current results do not have the targeted accuracy when compared with previous calibrations; however, we show how the extensive methodology development presented here can be used towards making reliable future measurements.

Geostandards and Geoanalytical Research↗

Using peak geometry and shifts in the x-ray spectrum of carbon from electron probe microanalysis to determine thermal maturity of organic matter

During the burial of mudstones, the associated organic matter undergoes gradual thermal maturation, a key process that can influence the reactivity of organic matter during catagenesis, the formation of hydrocarbon deposits and the chemical weathering of mudstones. Conventional methods for assessing the thermal maturity of organic matter often fail to reflect the geochemical heterogeneity between individual organic phases in mudstone samples. Here, we report an alternative, non-destructive, surficial and micro-scale (analytical spot size of ~ 300 nm with about 4 μm diffusion depth for micrometre-size organic grains) method to evaluate the thermal maturity of organic matter in mudstones using the carbon K α X-ray spectrum measured by field emission-electron probe microanalyser (FE-EPMA). Using this method, we observed correlations between parameter values derived from FE-EPMA spectra, including the peak position, the peak area and the intra-sample heterogeneity of these measurements, and independently measured vitrinite/solid bitumen reflectance for a suite of mudstones, representing different age, geological context and burial depth. With the increased values in peak area and position, we identified an increase in the carbon mass fraction of organic matter and the mean nominal oxidation state of carbon approaching zero. These trends, which are consistent with aromatisation and graphitisation, provide the rationale for using FE-EPMA to estimate the thermal maturity of organic matter. To explore some of these trends in more detail, we employed time-of-flight secondary ionisation mass spectrometry, X-ray photoelectron spectroscopy and optical reflectance measurements on a subset of samples.

Geostandards and Geoanalytical Research↗

RioM-1: A new calcite reference material for U-Pb LA-ICP-MS geochronology

Determining absolute ages of carbonate diagenesis, faulting, fossil formation, speleothem growth, carbonate-hosted hydrocarbon deposits, vein mineralisation and hydrothermal alteration has become increasingly accessible through LA-ICP-MS U-Pb dating of calcite, complementing traditional isotope dilution methods still applicable to certain materials (e.g., speleothems via micro-drilling). However, well-calibrated reference materials for LA-ICP-MS calcite geochronology remain scarce. Here, we characterise the Rio Maior calcite, designated ‘RioM-1’, as a potential reference material for U-Pb dating by LA-ICP-MS. Fragments (0.1 to 1 cm 3 ) from a single scalenohedral crystal were analysed by ID-TIMS (U-Pb), LA-ICP-MS (U-Pb and 87 Sr/ 86 Sr), and SIMS (O isotopes). RioM-1 displays high U mass fraction and low, though variable, proportions of common Pb. Combined ID-TIMS analyses from two independent laboratories yielded a Tera-Wasserburg lower intercept date of 63.93 ± 0.11 Ma (2 s , MSWD = 1.3, n = 16). LA-ICP-MS U-Pb data from three independent laboratories are concordant with the TIMS age, producing a pooled date of 64.10 ± 0.12/1.2 Ma (2 s , MSWD = 7.7, n = 708) and an initial 207 Pb/ 206 Pb ratio of 0.85 ± 0.01. Other calcite reference materials, when normalised to RioM-1, yielded dates within uncertainty of their published values. SIMS measurements returned a mean 18 O/ 16 O of 0.002044450 ± 181 (1 s ) and δ 18 O SMOW of 19.57 ± 0.92‰ (1 s ), while LA-ICP-MS strontium isotope measurement yielded a mean 87 Sr/ 86 Sr of 0.708177 ± 9 (2 s ).

Geostandards and Geoanalytical Research↗

Triple oxygen isotope compositions of isotopic reference waters: Implications for VSMOW-Scale and VSMOW-SLAP-Scale Δ′¹⁷O calibration

Triple oxygen isotope ratios of waters are commonly reported on the VSMOW–SLAP scale, whereas comparison with theoretical calculations and assessment of instrumental scale distortion require accurate constraints on the measured isotopic compositions of the primary isotopic reference materials (iRMs) themselves. In particular, the measured δ 17 O VSMOW and Δ ′ 17 O VSMOW values for SLAP and its substitute, SLAP2, remain insufficiently constrained and reported values differ among laboratories. Here, we measured triple oxygen isotope ratios for two primary iRMs (VSMOW and SLAP) and twelve secondary iRMs (VSMOW2, SLAP2, GISP, GRESP, USGS45, USGS46, USGS46a, USGS47, USGS48, USGS49, USGS50 and USGS53) using BrF 5 fluorination and dual-inlet isotope-ratio mass spectrometry. For SLAP, we obtained δ 18 O VSMOW = -55.50 ± 0.15‰ and δ 17 O VSMOW = -29.66 ± 0.08‰, giving Δ ′ 17 O VSMOW = 34 ± 6 per meg (all expanded uncertainties, k = 2). The corresponding values for SLAP2 agree within uncertainty. When expressed on the conventional VSMOW–SLAP scale, our Δ ′ 17 O VSMOW–SLAP values for all secondary iRMs with available literature values agree with previously published values within uncertainty, confirming interlaboratory comparability on that scale. In contrast, waters with low δ 18 O values, Δ ′ 17 O VSMOW values are systematically higher than the corresponding Δ ′ 17 O VSMOW–SLAP values. These results further suggest that accurate determination of the VSMOW-scale isotopic composition of SLAP and/or SLAP2 across laboratories is essential, particularly for low- δ 18 O samples, for which the difference between VSMOW-scale and VSMOW–SLAP-scale Δ ′ 17 O values becomes large, and for meaningful comparison between measured data and theoretical calculations.

Geostandards and Geoanalytical Research↗

Preparation and certification of Re-Os dating reference materials: Molybdenites HLP and JDC

Two Re-Os dating reference material molybdenites were prepared. Molybdenite JDC and molybdenite HLP are from a carbonate vein-type molybdenum-(lead)-uranium deposit in the Jinduicheng-Huanglongpu area of Shaanxi province, China. The samples proved to be homogeneous, based on the coefficient of variation of analytical results and an analysis of variance test. The sampling weight was 0.1 g for JDC and 0.025 g for HLP. An isotope dilution method was used for the determination of Re and Os. Sample decomposition and pre-concentration of Re and Os prior to measurement were accomplished using a variety of methods: acid digestion, alkali fusion, ion exchange and solvent extraction. Negative thermal ionisation mass spectrometry and inductively coupled plasma-mass spectrometry were used for the determination of Re and 187 Os concentration and isotope ratios. The certified values include the contents of Re and Os and the model ages. For HLP, the Re content was 283.8 ± 6.2 μg g −1 , 187 Os was 659 ± 14 ng g −1 and the Re-Os model age was 221.4 ± 5.6 Ma. For JDC, the Re content was 17.39 ± 0.32 μg g −1 , 187 Os was 25.46 ± 0.60 ng g −1 and the Re-Os model age was 139.6 ± 3.8 Ma. Uncertainties for both certified reference materials are stated at the 95% level of confidence. Three laboratories (from three countries: PR. China, USA, Sweden) joined in the certification programme. These certified reference materials are primarily useful for Re-Os dating of molybdenite, sulfides, black shale, etc.

Geostandards and Geoanalytical Research↗

Preliminary characterisation of new glass reference materials (GSA-1G, GSC-1G, GSD-1G and GSE-1G) by laser ablation-inductively coupled plasma-mass spectrometry using 193 nm, 213 nm and 266 nm wavelengths

New glass reference materials GSA-1G, GSC-1G, GSD-1G and GSE-1G have been characterised using a prototype solid state laser ablation system capable of producing wavelengths of 193 nm, 213 nm and 266 nm. This system allowed comparison of the effects of different laser wavelengths under nearly identical ablation and ICP operating conditions. The wavelengths 213 nm and 266 nm were also used at higher energy densities to evaluate the influence of energy density on quantitative analysis. In addition, the glass reference materials were analysed using commercially available 266 nm Nd:YAG and 193 nm ArF excimer lasers. Laser ablation analysis was carried out using both single spot and scanning mode ablation. Using laser ablation ICP-MS, concentrations of fifty-eight elements were determined with external calibration to the NIST SRM 610 glass reference material. Instead of applying the more common internal standardisation procedure, the total concentration of all element oxide concentrations was normalised to 100%. Major element concentrations were compared with those determined by electron microprobe. In addition to NIST SRM 610 for external calibration, USGS BCR-2G was used as a more closely matrix-matched reference material in order to compare the effect of matrix-matched and non matrix-matched calibration on quantitative analysis. The results show that the various laser wavelengths and energy densities applied produced similar results, with the exception of scanning mode ablation at 266 nm without matrix-matched calibration where deviations up to 60% from the average were found. However, results acquired using a scanning mode with a matrix-matched calibration agreed with results obtained by spot analysis. The increased abundance of large particles produced when using a scanning ablation mode with NIST SRM 610, is responsible for elemental fractionation effects caused by incomplete vaporisation of large particles in the ICP.

Geostandards and Geoanalytical Research↗

Homogeneity of the geochemical reference material BRP-1 (paraná basin basalt) and assessment of minimum mass

Reference materials (RM) are required for quantitative analyses and their successful use is associated with the degree of homogeneity, and the traceability and confidence limits of the values established by characterisation. During the production of a RM, the chemical characterisation can only commence after it has been demonstrated that the material has the required level of homogeneity. Here we describe the preparation of BRP-1, a proposed geochemical reference material, and the results of the tests to evaluate its degree of homogeneity between and within bottles. BRP-1 is the first of two geochemical RM being produced by Brazilian institutions in collaboration with the United States Geological Survey (USGS) and the International Association of Geoanalysts (IAG). Two test portions of twenty bottles of BRP-1 were analysed by wavelength dispersive-XRF spectrometry and major, minor and eighteen trace elements were determined. The results show that for most of the investigated elements, the units of BRP-1 were homogeneous at conditions approximately three times more rigorous than those strived for by the test of &ldquo;sufficient homogeneity&rdquo;. Furthermore, the within bottle homogeneity of BRP-1 was evaluated using small beam (1 mm 2 ) synchrotron radiation XRF spectrometry and, for comparison, the USGS reference materials BCR-2 and GSP-2 were also evaluated. From our data, it has been possible to assign representative minimum masses for some major constituents (1 mg) and for some trace elements (1-13 mg), except Zr in GSP-2, for which test portions of 74 mg are recommended.

Sao Paulo↗

Mercury, trace elements and organic constituents in atmospheric fine particulate matter, Shenandoah National Park, Virginia, USA: A combined approach to sampling and analysis

Compliance with U.S. air quality regulatory standards for atmospheric fine particulate matter (PM 2.5 ) is based on meeting average 24 hour (35 μ m −3 ) and yearly (15 μg m −3 ) mass‐per‐unit‐volume limits, regardless of PM 2.5 composition. Whereas this presents a workable regulatory framework, information on particle composition is needed to assess the fate and transport of PM 2.5 and determine potential environmental/human health impacts. To address these important non‐regulatory issues an integrated approach is generally used that includes (1) field sampling of atmospheric particulate matter on filter media, using a size‐limiting cyclone, or with no particle‐size limitation; and (2) chemical extraction of exposed filters and analysis of separate particulate‐bound fractions for total mercury, trace elements and organic constituents, utilising different USGS laboratories optimised for quantitative analysis of these substances. This combination of sampling and analysis allowed for a more detailed interpretation of PM 2.5 sources and potential effects, compared to measurements of PM 2.5 abundance alone. Results obtained using this combined approach are presented for a 2006 air sampling campaign in Shenandoah National Park (Virginia, USA) to assess sources of atmospheric contaminants and their potential impact on air quality in the Park. PM 2.5 was collected at two sampling sites (Big Meadows and Pinnacles) separated by 13.6 km. At both sites, element concentrations in PM 25 were low, consistent with remote or rural locations. However, element/Zr crustal abundance enrichment factors greater than 10, indicating anthropogenic input, were found for Hg, Se, S, Sb, Cd, Pb, Mo, Zn and Cu, listed in decreasing order of enrichment. Principal component analysis showed that four element associations accounted for 84% of the PM 2.5 trace element variation; these associations are interpreted to represent: (1) crustal sources (Al, REE); (2) coal combustion (Se, Sb), (3) metal production and/or mobile sources (Mo, Cd, Pb, Cu, Zn) and (4) a transient marine source (Sr, Mg). Concentrations of Hg in PM 2.5 at background levels in the single pg m −3 were shown by collection and analysis of PM 2.5 on filters and by an automated speciation analyser set up at the Big Meadows air quality site. The speciation unit revealed periodic elevation of reactive gaseous mercury (RGM) that co‐occurred with peaks in SO 2 , indicating an anthropogenic source. GC/MS total ion current chromatograms for the two sites were quite similar indicating that organic signatures were regional in extent and/or that the same compounds were present locally at each site. Calculated carbon preference index values for n ‐alkanes indicated that plant waxes rather than anthropogenic sources, were the dominant alkane source. Polycyclic aromatic hydrocarbons (PAHs) were detected, with a predominance of non‐alkylated, and higher molecular weight PAHs in this fraction, suggestive of a combustion source (fossil fuel or forest fires).

Virginia↗

USGS46 Greenland ice core water – A new isotopic reference material for δ2H and δ18O measurements of water

Ice core from Greenland was melted, filtered, homogenised, loaded into glass ampoules, sealed, autoclaved to eliminate biological activity, and calibrated by dual-inlet isotope-ratio mass spectrometry. This isotopic reference material (RM), USGS46, is intended as one of two secondary isotopic reference waters for daily normalisation of stable hydrogen (&delta; 2 H) and stable oxygen (&delta; 18 O) isotopic analysis of water with a mass spectrometer or a laser absorption spectrometer. The measured &delta; 2 H and &delta; 18 O values of this reference water were &minus;235.8 &plusmn; 0.7&permil; and &minus;29.80 &plusmn; 0.03&permil;, respectively, relative to VSMOW on scales normalised such that the &delta; 2 H and &delta; 18 O values of SLAP reference water are, respectively, &minus;428 and &minus;55.5&permil;. Each uncertainty is an estimated expanded uncertainty ( U = 2 u c ) about the reference value that provides an interval that has about a 95-percent probability of encompassing the true value. This reference water is available in cases containing 144 glass ampoules that are filled with either 4 ml or 5 ml of water per ampoule.

Geostandards and Geoanalytical Research↗

Characterisation of a natural quartz crystal as a reference material for microanalytical determination of Ti, Al, Li, Fe, Mn, Ga and Ge

A natural smoky quartz crystal from Shandong province, China, was characterised by laser ablation ICP-MS, electron probe microanalysis (EPMA) and solution ICP-MS to determine the concentration of twenty-four trace and ultra trace elements. Our main focus was on Ti quantification because of the increased use of this element for titanium-in-quartz (TitaniQ) thermobarometry. Pieces of a uniform growth zone of 9 mm thickness within the quartz crystal were analysed in four different LA-ICP-MS laboratories, three EPMA laboratories and one solution-ICP-MS laboratory. The results reveal reproducible concentrations of Ti (57 &plusmn; 4 &mu;g g -1 ), Al (154 &plusmn; 15 &mu;g g -1 ), Li (30 &plusmn; 2 &mu;g g -1 ), Fe (2.2 &plusmn; 0.3 &mu;g g -1 ), Mn (0.34 &plusmn; 0.04 &mu;g g -1 ), Ge (1.7 &plusmn; 0.2 &mu;g g -1 ) and Ga (0.020 &plusmn; 0.002 &mu;g g -1 ) and detectable, but less reproducible, concentrations of Be, B, Na, Cu, Zr, Sn and Pb. Concentrations of K, Ca, Sr, Mo, Ag, Sb, Ba and Au were below the limits of detection of all three techniques. The uncertainties on the average concentration determinations by multiple techniques and laboratories for Ti, Al, Li, Fe, Mn, Ga and Ge are low; hence, this quartz can serve as a reference material or a secondary reference material for microanalytical applications involving the quantification of trace elements in quartz.

Geostandards and Geoanalytical Research↗