Geology Reports⌕ Search

SEARCH · Geology Reports

Results for “Water Resource Report”

Search indexed USGS publications on groundwater, aquifers, geologic maps, mineral resources and earthquakes. Explore source records by subject and place.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90Linked to original sources

Hydrogeology of the interstream area between Ty Ty Creek and Ty Ty Creek tributary near Plains, Georgia

This report is part of an interdisciplinary effort to identify and describe processes that control movement and fate of selected fertilizers and pesticides in the surface and subsurface environments in the Fall Line Hills district of the Georgia Coastal Plain physiographic province. This report describes the hydrogeology of the interstream area between Ty Ty Creek and it's tributary near Plains, Sumter County, Georgia. Geologic units of interest to this study are, in ascending order, (1) the Tuscahoma Formation, a bluish gray, silty clay; (2) the Tallahatta Formation, a fine-to-coarse, poorly sorted quartz sand that is divided into an upper and lower unit; and (3) the undifferentiated overburden, which consists of fine to medium poorly sorted sand, silt and clay. Continuous-core samples indicate that the unsaturated zone includes the undifferentiated overburden and the upper unit of the Tallahatta Formation, and attains a maximum thickness of about 52 feet (ft) in the southern part of the study area. The Claiborne aquifer in the study area consists of the lower unit of the Tallahatta Formation and ranges in thickness from 3 ft near Ty Ty Creek tributary to about 20 ft in the upland divide area. It is confined below by the clayey sediments of the Tuscahoma Formation. The Claiborne aquifer in the study area generally is confined above by an extensive clay layer that is the base if the upper unit of the Tallahatta Formation. Fluctuations in the amount of vertical recharge to the aquifer result in areal and temporal changes in aquifer conditions from confined to unconfined in parts of the study area. Hydraulic conductivity of the aquifer ranges from 3.5 to 7 feet per day. The transmissivity of the aquifer is approximately 50 feet squared per day. Water-level data indicate the potentiometric surface slopes to the south, southeast, and southwest with a gradient of about 87 to 167 feet per mile. The shape of the potentiometric surface and the direction of groundwater flow remains relatively unchanged during high and low water-level periods. Water levels in the Claiborne aquifer fluctuated by a maximum of 6 ft during the period from January to December 1991. Recharge to the Claiborne aquifer consists of a local and regional flow component. Lateral ground-water flow (regional flow) into the study area is dependent on regional hydraulic controls (pumpage, stream discharge, and rainfall). The rate of lateral movement of ground water is dependent on the hydraulic conductivity of the saturated zone, the hydraulic gradient, and other hydraulic factors, and is considered to be relatively constant. Local recharge enters the ground-water system as rainfall that percolates down to the water table. Annual water-level fluctuations in the Claiborne aquifer indicate that the majority of regional and local recharge occurs in the interstream area with recharge decreasing downslope to the streams. Ground water discharges to Ty Ty Creek and it's tributary throughout the year during low and high water-level periods.

Georgia↗

Sediment transport, particle sizes, and loads in lower reaches of the Chippewa, Black, and Wisconsin Rivers in Western Wisconsin

Hydraulic and sediment data were collected at three sites on the Chippewa River (near Caryville, at Durand, and near Pepin); at one site near Galesville on the Black River; and at one site at Muscoda on the Wisconsin River during water years 1976-83. This report summarizes an interpretation of those data by providing (1) a description of the relation of suspended sediment, bedload, and total-sediment discharge to water discharge; (2) a description of particle-size characteristics of bed material, bedload, and suspended sediment; and (3) estimates of annual and average annual suspended load, bedload, and total-sediment load for water years 1974-83. Direct measurement with a Helley-Smith bedload sampler and calculations by the modified-Einstein procedure were used to estimate bedload. Single equations describe the suspended- and totalsediment transport-rate relations for Chippewa River at Durand and main channel at Pepin, and the Black River near Galesville. Two equations were needed to define the transport- rate relations for the Chippewa River near Caryville and Wisconsin River at Muscoda. Bed material at all sites except Chippewa River near Caryville were of similar particle size and exhibited little variation with time or location in the river cross sections. Median diameter at these sites ranged from 0.35 to 0.84 mm (millimeter). At Chippewa River near Caryville, median diameter ranged from 0.42 to 15 mm. Helley-Smith bedload at Chippewa River at Durand and near Pepin, Black River near Galesville, and Wisconsin River at Muscoda were of similar particle size. About 57 to 65 percent of bedload at all sites except Chippewa River near Caryville was in the 0.4- to 0.6- mm size range. About 50 percent of bedload at Chippewa River near Caryville was in the 0.5- to 1.0-mm size range. Suspended sediment at all sites except Chippewa River near Caryville was in the sand-size range; the average median diameters were between 0.17 and 0.22 mm. At Chippewa River near Caryville, 60 percent (on the average) of suspended sediment was finer than 0.062 mm. Average annual total-sediment load and the percentage transported as bedload were determined for a 10-year period (water years 1974-83)(October 1,1973-September 30, 1982). These loads and percentages were, respectively, 123,000 tons and 35 percent at Chippewa River near Caryville; 1,073,000 tons and 61 percent at Chippewa River at Durand; 940,000 tons and 44 percent at Chippewa River near Pepin; 277,000 tons and 43 percent at Black River near Galesville; and 558,000 tons and 49 percent at Wisconsin River at Muscoda.

Wisconsin↗

Hydrology and water quality of Powers Lake, southeastern Wisconsin

This report describes the hydrology and water quality of Powers Lake, a recreational lake in a densely populated area of southeastern Wisconsin, from October 16, 1986 - October 15, 1987. The hydrologic budget for the study period showed that direct precipitation on the lake and ground water were dominant sources of water entering the lake (37 and 36 percent, respectively) and that streamflow dominated the outflow. Surface runoff contributed 27 percent of the inflow-23 percent from Powers Lake inlet and 4 percent from shoreline drainage. Streamflow through Powers Lake outlet accounted for 62 percent of the outflow and evaporation accounted for 38 percent. Based on the streamflow from Powers Lake outlet, the lake's hydraulic residence time was 3.8 years. During the study period, precipitation was 27.16 inches or 4.08 inches below long-term (1951-80) average. The data were adjusted or normalized to represent an average year of precipitation and runoff to help evaluate the water quality of the lake for an average year. For an average year, precipitation dominated inflow (42 percent), followed by ground water (32 percent), Powers Lake inlet (21 percent), and shoreline drainage (5 percent). Streamflow through Powers Lake outlet accounted for 61 percent of an average year's outflow budget and the remaining 39 percent was evaporation. Based on an average year's streamflow from Powers Lake outlet, the lake's hydraulic residence time was 4.2 years. Phosphorus budgets were prepared for the study period and for an estimated normal year. The phosphorus budget for the study period showed that, of the total inputs (516 pounds), surface runoff contributed the largest amount; shoreline drainage contributed 44 percent, and Powers Lake inlet contributed 36 percent. Direct precipitation contributed 11 percent; ground water, 2 percent; and septic systems, 7 percent. Of the total outputs, 83 pounds (16 percent) was lost from the lake via the outlet; 433 pounds (84 percent) was lost to the sediments as the phosphorus that was attached to particles settled to the lake bottom. An estimated phosphorus budget for a normal year showed that of the total inputs (744 pounds), surface runoff contributed the largest amount; Powers Lake inlet contributed 45 percent and shoreline drainage contributed 35 percent. Precipitation contributed 9 percent; ground water, 1 percent; and septic systems, 10 percent. The health of the lake was evaluated using Carlson's Trophic State Index and Vollenweider's model. Carlson's Trophic State Index showed that Powers Lake was moderately enriched and in the mesotrophic range. Comparison of guidelines from Vollenweider's model showed that the total phosphorus input for the study period and for an estimated average year would not cause eutrophic conditions.

Wisconsin↗

Hydrogeology of the alluvial aquifers at the Pueblo Depot Activity near Pueblo, Colorado

In 1992, the U.S. Army Corps of Engineers and the U.S. Army Pueblo Depot Activity requested that the U.S. Geological Survey study the hydrogeology of the Pueblo Depot Activity, a 36-square-mile facility that has been operated by the U.S. Army since 1942. The purpose of the study was to provide an updated hydrogcological framework to facilitate the investigation of specific sites on the facility that might require remediation. This report describes the hydrogeology of the alluvial aquifers beneath the facility and the distribution of specific conductance of ground water in those aquifers. The Pueblo Depot Activity is underlain by two alluvial aquifers: (1) The terrace alluvial aquifer, which is a southernmost, downgradicnt part of an erosional remnant of an extensive terrace deposit; and (2) the Chico Creek alluvial aquifer, a smaller alluvial system along Chico Creek. These aquifers primarily consist of sand separated by clay layers and are underlain by the almost impermeable Pierre Shale of Upper Cretaceous age. The bedrock surface, which has an average slope of 28 feet per mile to the south-southeast, is relatively regular beneath the northern two-thirds of the terrace deposits at the Pueblo Depot Activity, but forms an irregular surface of troughs, hills, and ridges in the southwestern part of the terrace alluvium. Saturated thickness of the terrace aquifer ranges from 0 to about 45 feet. The bedrock surface beneath the Chico Creek aquifer slopes about 31 feet per mile to the south. Saturated thickness of the Chico Creek alluvium ranges from 0 to about 30 ft, but generally is less than 15 ft. Total thickness of the Chico Creek alluvium in the saturated area ranges from 16 to 41 ft. Water in the terrace alluvial aquifer generally flows southward, except in the southwestern part where directions of flow are complex. Measured hydraulic conductivity ranges from 0.4 to 400 feet per day (median 26 feet per day). Estimates for vertically averaged ground-water-flow velocity range from 0.02 to 3 feet per day (median 0.9 foot per day). Water in the Chico Creek alluvial aquifer generally flows southward to the Arkansas River alluvium. Measured hydraulic conductivity ranges from 14 to 310 feet per day (median 42 feet per day). Estimates for vertically averaged ground water-flow velocity range from 0.5 to 4 feet per day (median 0.7 foot per day). Specific conductance of ground water in the terrace alluvial aquifer generally is less than 800 microsiemens per centimeter; the smallest values were observed in the north-central part of the Pueblo Depot Activity. In the southwestern part of the terrace alluvial aquifer, values varied in an irregular pattern, and values as large as 3,300 microsiemens per centimeter were measured locally. Water in the terrace alluvial aquifer was dominated by the sodium cation and usually by the bicarbonate anion, and sulfate usually was present in substantial (and locally predominant) concentrations. Measured specific conductance of water in the Chico Creek alluvial aquifer ranged from 683 to 1,460 microsiemens per centimeter. This water was dominated by the sodium cation and by the bicarbonate and sulfate anions; sulfate was more predominant to the south.

Colorado↗

Occurrence of organochlorine compounds in whole fish tissue from streams of the lower Susquehanna River Basin, Pennsylvania and Maryland, 1992

Tissue samples of whole body white sucker ( Catostomus commersoni ) were collected at 15 sites and smallmouth bass ( Micropterus dolomieu ) were collected at 5 sites during 1992 in the Lower Susquehanna River Basin to determine the occurrence and distribution of 28 selected organochlorine compounds as part of the U.S. Geological Survey’s National Water-Quality Assessment (NAWQA) Program. Only 12 of the 28 compounds occurred at concentrations greater than the 5 µg/kg reporting limit (total PCB’s reporting limit is ‹50 µg/kg and toxaphene is ‹200 µg/kg). The most frequently reported compounds were p,p ’-DDE (reported in all tissue samples), total polychlorinated biphenyls (PCB’s), and trans-nonachlor. High concentrations of p,p’ -DDE and low concentrations of the other DDT metabolites for the Lower Susquehanna River sites indicate no recent influx of DDT. Comparison with historical data from the Lower Susquehanna River Basin shows a decline of organochlorine concentrations within the basin. In 1987, Quittapahilla Creek had the highest concentrations of p,p’ -DDE in a national survey of contaminant occurrence in fish tissue conducted by the U.S. Environmental Protection Agency. This stream ranked the highest for total DDT of the 20 NAWQA studies started nationally in 1991. Total DDT concentrations were higher in agriculture-dominated (>50 percent) sites than in forest-dominated (>50 percent) sites with the exception of Deer Creek and Big Beaver Creek. These two sites are located more in grazing areas that lack a substantial crop-land use. Concentrations of total PCB’s were highest in basins with greater than 10 percent urban land use excluding the larger river sites. Concentrations of total chlordane were highest at sites with greater than 70 percent agricultural and 10 percent urban land use. Regional comparisons of total DDT, total PCB’s, and total chlordane in white sucker tissue from the Lower Susquehanna, Hudson (in New York), and Connecticut River Basins showed that median concentrations of total DDT were different (p=0.05), with the Lower Susquehanna Basin being the lowest. Total PCB’s and total chlordane medians were similar. Comparison of the data from national and regional studies with data from this local study showed concentrations of p,p’ -DDE in the Lower Susquehanna River Basin are similar to those nationwide and lower than the concentrations measured in the Northeast. PCB concentrations in the Lower Susquehanna River Basin and the Northeast were higher than those nationwide.

Water-Resources Investigations Report↗

SUTRA: A model for 2D or 3D saturated-unsaturated, variable-density ground-water flow with solute or energy transport

SUTRA (Saturated-Unsaturated Transport) is a computer program that simulates fluid movement and the transport of either energy or dissolved substances in a subsurface environment. This upgraded version of SUTRA adds the capability for three-dimensional simulation to the former code (Voss, 1984), which allowed only two-dimensional simulation. The code employs a two- or three-dimensional finite-element and finite-difference method to approximate the governing equations that describe the two interdependent processes that are simulated: 1) fluid density-dependent saturated or unsaturated ground-water flow; and 2) either (a) transport of a solute in the ground water, in which the solute may be subject to: equilibrium adsorption on the porous matrix, and both first-order and zero-order production or decay; or (b) transport of thermal energy in the ground water and solid matrix of the aquifer. SUTRA may also be used to simulate simpler subsets of the above processes. A flow-direction-dependent dispersion process for anisotropic media is also provided by the code and is introduced in this report. As the primary calculated result, SUTRA provides fluid pressures and either solute concentrations or temperatures, as they vary with time, everywhere in the simulated subsurface system. SUTRA flow simulation may be employed for two-dimensional (2D) areal, cross sectional and three-dimensional (3D) modeling of saturated ground-water flow systems, and for cross sectional and 3D modeling of unsaturated zone flow. Solute-transport simulation using SUTRA may be employed to model natural or man-induced chemical-species transport including processes of solute sorption, production, and decay. For example, it may be applied to analyze ground-water contaminant transport problems and aquifer restoration designs. In addition, solute-transport simulation with SUTRA may be used for modeling of variable-density leachate movement, and for cross sectional modeling of saltwater intrusion in aquifers at near-well or regional scales, with either dispersed or relatively sharp transition zones between freshwater and saltwater. SUTRA energy-transport simulation may be employed to model thermal regimes in aquifers, subsurface heat conduction, aquifer thermal-energy storage systems, geothermal reservoirs, thermal pollution of aquifers, and natural hydrogeologic convection systems. Mesh construction, which is quite flexible for arbitrary geometries, employs quadrilateral finite elements in 2D Cartesian or radial-cylindrical coordinate systems, and hexahedral finite elements in 3D systems. 3D meshes are currently restricted to be logically rectangular; in other words, they are similar to deformable finite-difference-style grids. Permeabilities may be anisotropic and may vary in both direction and magnitude throughout the system, as may most other aquifer and fluid properties. Boundary conditions, sources and sinks may be time dependent. A number of input data checks are made to verify the input data set. An option is available for storing intermediate results and restarting a simulation at the intermediate time. Output options include fluid velocities, fluid mass and solute mass or energy budgets, and time-varying observations at points in the system. Both the mathematical basis for SUTRA and the program structure are highly general, and are modularized to allow for straightforward addition of new methods or processes to the simulation. The FORTRAN-90 coding stresses clarity and modularity rather than efficiency, providing easy access for later modifications.

Water-Resources Investigations Report↗

Arsenic and selenium in soils and shallow ground water in the Turtle Lake, New Rockford, Harvey Pumping, Lincoln Valley, and LaMoure irrigation areas of the Garrison Diversion Unit, North Dakota

The Garrison Diversion Unit project was authorized as part of the Pick-Sloan Missouri River Basin program to divert water from Lake Sakakawea to irrigation areas in North Dakota. A special Garrison Commission was created to evaluate an environmental concern that return flow from the irrigation areas might contain metals in toxic concentrations. This report summarizes the results of detailed investigations of the Turtle Lake, New Rockford, Harvey Pumping, Lincoln Valley, and LaMoure irrigation areas. A total of 223 soil samples were collected from the irrigation areas and analyzed for elemental composition. Water extractions were done on 40 of the 223 soil samples using a 1:5 soil-to-water extraction method, and the solution from the extraction was analyzed for elemental composition. A total of 52 ground-water samples were collected and analyzed for inorganic constituents and organic carbon. Average arsenic concentrations in the entire soil column ranged from 1.0 milligram per kilogram in the Harvey Pumping irrigation area to 70 milligrams per kilogram in the New Rockford irrigation area. Average selenium concentrations ranged from less than 0.1 milligram per kilogram in the Turtle Lake, New Rockford, Harvey Pumping, and Lincoln Valley irrigation areas to 6.0 milligrams per kilogram in the Turtle Lake irrigation area. In the Turtle Lake irrigation area, average arsenic and selenium concentrations generally increased with depth through the topsoil, oxidized soil, and transition soil but decreased in the reduced soil at the bottom of the sampled horizons. Average arsenic concentrations in the New Rockford irrigation area follow the same pattern as in the Turtle Lake irrigation area, but selenium concentrations do not show a clear pattern of variation with depth. In the Harvey Pumping and Lincoln Valley irrigation areas, arsenic and selenium concentrations do not appear to vary systematically with depth. No correlation is shown between the concentrations in soils and soil extracts, indicating that, based on conditions of laboratory soil-water extraction experiments, trace-element concentrations in soils are not good predictors of trace-element concentrations in irrigation return flow. Arsenic concentrations in the aquifers ranged from less than 1 microgram per liter to 27 micrograms per liter. Arsenic concentrations generally were larger in the deep part of the aquifers underlying the Turtle Lake and New Rockford irrigation areas than in the shallow part of the aquifers. In the shallow part of the aquifers, where oxidizing conditions prevail, arsenic is strongly adsorbed to soil particles. In the deep part of the aquifers, where reducing conditions prevail, arsenic is more mobile. Selenium concentrations in the aquifers ranged from less than 1 microgram per liter to 4 micrograms per liter. Little difference existed between the selenium concentrations in the shallow part of the aquifers underlying the irrigation areas and the concentrations in the deep part of the aquifers.

Water-Resources Investigations Report↗

Availability and Quality of Water from Underground Coal Mines in Johnson and Martin Counties, Kentucky

This report provides water users with detailed information on the location, quantity, and quality of water available from underground coal mines in the Breathitt Formation of Pennsylvanian age in part of eastern Kentucky. The principal coal seams mined are the Van Lear in Johnson County and the Alma in Martin County. Coal mines that contained water were located by field inventory and coal-mine maps. The principal factors that affect the occurrence of water in coal mines are the size of the recharge area overlying the mine, the intensity and duration of precipitation, and the altitude of the mine relative to that of the nearest perennial stream. Ten above-drainage mines (that is, mines at higher elevations than that of the nearest perennial stream) are considered potential sources of water. Discharge from these mines ranged from 12 to 1,700 gallons per minute. The highest sustained discharge from a mine ranged from 750 to 1,200 gallons per minute. The water in coal mines is part of the hydrologic system and varies seasonally with precipitation. Annual discharge from most above-drainage mines ranged from 3 to 10 percent of annual precipitation on the 1and-surface area above the mine. Eight below-drainage mines are considered potential sources of water. Two were test-pumped at rates of 560 to 620 gallons per minute for as long as 6 hours. After test pumping the Warfield Mining No. 1 mine during September 1977 and March 1978, the recovery (or recharge) rates were significantly different. In September, the recharge rate was about 1,150 gallons per minute, but in March the recharge rate was 103,500 gallons per minute. This difference reflects the seasonal variations in the amount of water available to the ground-water system. Estimates of water stored in below-drainage mines ranged from 22 to 1,462 million gallons. This storage represents a safety factor sufficient to provide water through periods of limited recharge to the mine. Most mine water is of the calcium magnesium sulfate type. In general, water from below-drainage mines had lower concentrations of dissolved constituents and higher pH than water from mines above drainage. The hardness of water ranged from soft to very hard and pH ranged -from 3.1 to 8.0 units. Dissolved iron ranged from 0.01 to 64 milligrams per liter. Phenol concentrations in water from eight coal mines ranged from 0 to 5 micrograms per liter. There seems to be a significant difference in the chemical quality of water from above- and below-drainage mines. The concentration of most constituents was lower in water from below-drainage mines than it was from above-drainage mines. The better quality water from below-drainage mines may reflect (1) lower mineralization resulting from less atmospheric oxygen available to react with pyrite or, (2) the result of sampling only the upper zones of water in below-drainage mines where the water has been diluted by less mineralized surface water or inflow or recharge.

Water-Resources Investigations Report↗

Simulation of regional ground-water flow in the Upper Deschutes Basin, Oregon

This report describes a numerical model that simulates regional ground-water flow in the upper Deschutes Basin of central Oregon. Ground water and surface water are intimately connected in the upper Deschutes Basin and most of the flow of the Deschutes River is supplied by ground water. Because of this connection, ground-water pumping and reduction of artificial recharge by lining leaking irrigation canals can reduce the amount of ground water discharging to streams and, consequently, streamflow. The model described in this report is intended to help water-management agencies and the public evaluate how the regional ground-water system and streamflow will respond to ground-water pumping, canal lining, drought, and other stresses. Ground-water flow is simulated in the model by the finite-difference method using MODFLOW and MODFLOWP. The finite-difference grid consists of 8 layers, 127 rows, and 87 columns. All major streams and most principal tributaries in the upper Deschutes Basin are included. Ground-water recharge from precipitation was estimated using a daily water-balance approach. Artificial recharge from leaking irrigation canals and on-farm losses was estimated from diversion and delivery records, seepage studies, and crop data. Ground-water pumpage for irrigation and public water supplies, and evapotranspiration are also included in the model. The model was calibrated to mean annual (1993-95) steady-state conditions using parameter-estimation techniques employing nonlinear regression. Fourteen hydraulic-conductivity parameters and two vertical conductance parameters were determined using nonlinear regression. Final parameter values are all within expected ranges. The general shape and slope of the simulated water-table surface and overall hydraulic-head distribution match the geometry determined from field measurements. The fitted standard deviation for hydraulic head is about 76 feet. The general magnitude and distribution of ground-water discharge to streams is also well simulated throughout the model. Ground-water discharge to streams in the area of the confluence of the Deschutes, Crooked, and Metolius Rivers is closely matched. The model was also calibrated to transient conditions from 1978 to 1997 using traditional trial-and-error methods. Climatic cycles during this period provided an excellent regional hydrologic signal for calibration. Climate-driven water-level fluctuations are simulated with reasonable accuracy over most of the model area. The timing and magnitude of simulated water-level fluctuations caused by annual pulses of recharge from precipitation match those observed reasonably well, given the limitations of the time discretization in the model. Water-level fluctuations caused by annual canal leakage are simulated very well over most of the area where such fluctuations occur. The transient model also simulates the volumetric distribution and temporal variations in ground-water discharge reasonably well. The match between simulated and measured volume of and variations in ground-water discharge is, however, somewhat dependent on geographic scale. The rates of and variations in ground-water discharge are matched best at regional scales. Example simulations were made to demonstrate the utility of the model for evaluating the effects of ground-water pumping or canal lining. Pumping simulations show that pumped water comes largely from aquifer storage when pumping begins, but as the water table stabilizes, the pumping increasingly diminishes the discharge to streams and, hence, streamflow. The time it takes for pumping to affect streamflow varies spatially depending, in general, on the location of pumping relative to the discharge areas. Canal-lining simulations show similar effects.

Water-Resources Investigations Report↗

Ground-water quality in Bannock, Bear Lake, Caribou, and part of Power counties, southeastern Idaho

This report provides information about the current quality of ground waters in southeastern Idaho and discusses the natural and manmade environmental controls on that quality. This information will be useful in planning and monitoring the development and use of the ground-water resources of southeastern Idaho. The southeastern corner of Idaho, as described in this report, encompasses an area of about 4,000 mil in Bannock, Bear Lake, Caribou, and part of Power Counties. The popu- lation of the area in 1975, based on best estimates by the Idaho Division of Budget, Policy Planning, and Coordination (1976) was 75,200. About 80 percent of the population is in and near the city of Pocatello, which is the second largest population center in the State. Pocatello's economy depends largely on manufacturing and industrial processing, which includes chemicalfertilizer plants. The econ- omy in the rural areas depends largely on agriculture--both dry and irrigated farming are practiced. Mining is important and expected to dominate the economy in the eastcentral part of the area in the future. Natural resources include phosphate ore, which makes up about 35 percent of the U.S. reserves (U.S. Department of Interior and U.S. Department of Agriculture, 1977); ground water, which mostly underlies the several intermontane valleys that dissect the area; and hot springs, which indicate that geothermal energy sources may underlie part of the area. Also, current (1978) speculation is that petroleum reserves may be present in the vicinity of Bear Lake. Development of more sprink- ler-irrigated lands, increases in population, and growth of phosphate mining are expected to place stress on the ground-water resources, both in quality and quantity. The purpose of this report is to present the results of a study whose primary objectives were (1) to provide current waterquality data representative of the water in several different aquifers (water- bearing formations) in the study area, and (2) to relate these data to natural and manmade environmental controls. The wells sampled during this study establish a quasi-network, which could be resampled in the future to document and analyze changes (if any) in ground-water quality. Based on this information, planners and water managers could better understand the causeand-effect relations controlling water quality and could better manage land and water-resource development. The report is designed for ease of reading and presentation. It uses maps, tables, and abbreviated text to describe geology, hydrology, and ground-water quality and how they are interrelated. Some practical ways for improving water quality are discussed for the benefit of individual water users. The field data collected in making the study are contained in the Data Section of this report. The authors gratefully acknowledge the many individual well owners, municipal officials, and private industries that provided well information and allowed access to their properties and collection of water samples. Without their help, this work could not have been done. Water samples were collected at 103 well sites. Waterlevel measurements were made at 98 of these sites during July, August, and September of 1976. This study was made by the U.S. Geological Survey in cooperation with the Idaho Department of Water Resources. A similar study is being made (1978) in north Idaho. Other studies are planned, specifically to obtain ground-water-quality data in areas where land and water-resource development is expected or accelerating.

Idaho↗

Trichloroethylene and 1,1-dichloroethylene concentrations in ground water after temporary shutdown of the reclamation well field at Air Force Plant 44, Tucson, Arizona, 1999

Industrial activities beginning in the early 1940s resulted in extensive contamination of ground water near the Tucson International Airport, Tucson, Arizona, including an area around Air Force Plant 44, an industrial facility located on land owned by the U.S. Air Force and operated by a defense contractor. Principal ground-water contaminants are volatile organic compounds, primarily trichloroethylene (also called trichloroethene) and 1,1-dichloroethylene (also called 1,1-dichloroethene). A ground- water reclamation system was put into operation in 1987 to extract and treat contaminated ground water at Air Force Plant 44 and the downgradient area that is south of Los Reales Road. The ground- water reclamation system consists of 25 extraction wells, 22 recharge wells, and a water-treatment facility. Soil-vapor extraction techniques are being used to remove volatile organic compounds from the unsaturated zone. More than 120,000 pounds of volatile organic compounds have been removed from the regional aquifer and overlying unsaturated zone at Air Force Plant 44 and adjacent downgradient areas south of Los Reales Road. Air Force Plant 44 and adjacent areas being remediated by the ground-water reclamation system are about 7 square miles. To assess ground-water cleanup progress at Air Force Plant 44 and surrounding areas south of Los Reales Road, and possibly to identify areas that are resistant to cleanup attempts, ground-water samples were collected and analyzed after water levels had returned to near-equilibrium conditions following a 3-week shutdown of extraction and recharge wells. Modifications of the standard ground-water sampling procedures used at the site also were tested. The modifications included tests of a reduced-flow purging and sampling method in six monitoring wells and vertical- profile sampling in five extraction wells at the reclamation well field. The water treatment facility and all extraction and recharge wells at the reclamation well field were shut down on April 15, 1999, and water levels were allowed to recover for about 3 weeks before samples of ground water were obtained from 102 wells at Air Force Plant 44 and surrounding areas. Concentrations of trichloroethylene and 1,1-dichloroethylene were determined for samples obtained during the sitewide sampling effort. Data for 101 wells sampled in February 1999 before shutdown were compared with data obtained for wells sampled in May 1999 after shutdown. Concentrations of trichloroethylene increased in 36 wells, remained the same in 32 wells, and decreased in 33 wells. Increases in concentrations of trichloroethylene of as much as 1,476 micrograms per liter and decreases of as much as 2,292 micrograms per liter were reported after shutdown. Concentrations of trichloroethylene remained the same for the two sampling periods in wells that had concentrations that were at, or close to, the lower reporting limit (0.5 micrograms per liter) before shutdown. Net change in concentrations of trichloroethylene after shutdown on a percentage basis ranged from an increase of 1,300 percent to a decrease of 100 percent. Increases in concentrations of 1,1-dichloroethylene after shutdown of the reclamation well field of as much as 66 micrograms per liter and decreases of as much as 411.6 micro- grams per liter were reported. Concentrations of 1,1-dichloroethylene remained the same for the two sampling periods in wells that had concentrations that were at, or close to, the lower reporting limit (0.5 micrograms per liter) before shutdown. Net change in concentrations of 1,1-dichloroethylene after shutdown on a percentage basis ranged from an increase of 660 percent to a decrease of 100 percent. Data obtained from the water samples indicate that the largest changes in concentrations of trichloroethylene and 1,1-dichloroethylene occurred in samples collected from wells completed in the upper zone of the regional aquifer, along the axis of the contaminant plume, in close proximity to previously identified historical disposal areas. Changes in contaminant concentrations observed after shutdown of the well field probably were the result of changes in ground-water flow directions under nonpumping conditions compared with those present when the extraction and recharge wells were operating. Minimal changes occurred at the perimeter of the plume, which suggests that operation of the reclamation well field has been successful at containing the spread of the plume. New contaminant-source areas were not identified within the perimeter of the plume. A modification of the standard sampling technique used at Air Force Plant 44 was tested in six wells. In these wells, greatly reduced flow rates were used for well purging and sampling. Results indicate no distinct pattern of change of contaminant concentrations compared with concentrations in samples subsequently obtained using the standard technique, and no advantage was evident for using this method in routine sampling of the monitoring wells at Air Force Plant 44. Temperature profiles obtained before vertical-profile sampling of selected wells indicate little temperature variation with depth. The temperature-profile information suggests that under nonpumping conditions, most of the water enters these wells near the top of the screened interval and moves downward in response to a hydraulic gradient in the regional aquifer. Samples at depths below the top of the screened interval probably do not accurately represent water from the adjacent sediments. Vertical-profile samples were obtained in five wells and analyzed for concentrations of trichloroethylene. None of the wells showed large enough variation of contaminant concentrations with depth to indicate that a major improvement in extraction efficiency could be obtained by pumping selectively from a restricted interval. The largest variation in concentrations of trichloroethylene with depth that was observed ranged from 62 micrograms per liter near the top of the screened interval to 42 micrograms per liter near the bottom of the screened interval of one of the wells. The lack of large variation is probably the result of downward water flow in the casing of these wells.

Arizona↗

Nutrients in ground water and surface water of the United States; an analysis of data through 1992

Historical data on nutrient (nitrogen and phosphorus species) concentrations in ground-and surface-water samples were compiled from 20 study units of the National Water-Quality Assessment (NAWQA) Program and 5 supplemental study areas. The resultant national retrospective data sets contained analyses of about 12,000 Found-water and more than 22,000 surface-water samples. These data were interpreted on regional and national scales by relating the distributions of nutrient concentrations to ancillary data, such as land use, soil characteristics, and hydrogeology, provided by local study-unit personnel. The information provided in this report on environmental factors that affect nutrient concentrations in ground and surface water can be used to identify areas of the Nation where the vulnerability to nutrient contamination is greatest. Nitrate was the nutrient of greatest concern in the historical ground-water data. It is the only nutrient that is regulated by a national drinking-water standard. Nitrate concentrations were significantly different in ground water affected by various land uses. Concentrations in about 16 percent of the samples collected in agricultural areas exceeded the drinking-water standard. However, the standard was exceeded in only about 1 percent of samples collected from public-supply wells. A variety of ancillary factors had significant relations to nitrate concentrations in ground water beneath agricultural areas. Concentrations generally were highest within 100 feet of the land surface. They were also higher in areas where soil and geologic characteristics promoted rapid movement of water to the aquifer. Elevated concentrations commonly occurred in areas underlain by permeable materials, such as carbonate bedrock or unconsolidated sand and gravel, and where soils are generally well drained. In areas where water movement is impeded, denitrification might lead to low concentrations of nitrate in the ground water. Low concentrations were also related to interspersion of pasture and woodland with cropland in agricultural areas. Elevated nitrate concentrations in areas of more homogeneous cropland probably were a result of intensive nitrogen fertilizer application on large tracts of land. Certain regions of the United States seemed more vulnerable to nitrate contamination of ground water in agricultural areas. Regions of greater vulnerability included parts of the Northeast, Midwest, and West Coast. The well-drained soils, typical in these regions, have little capacity to hold water and nutrients; therefore, these soils receive some of the largest applications of fertilizer and irrigation in the Nation. The agricultural land is intensively cultivated for row crops, with little interspersion of pasture and woodland. Nutrient concentrations in surface water also were generally related to land use. Nitrate concentrations were highest in samples from sites downstream from agricultural or urban areas. However, concentrations were not as high as in ground water and rarely exceeded the drinking-water standard. Elevated concentrations of nitrate in surface water of the Northeastern United States might be related to large amounts of atmospheric deposition (acid rain). High concentrations in parts of the Midwest might be related to tile drainage of agricultural fields. Ammonia and phosphorus concentrations were highest downstream from urban areas. These concentrations generally were high enough to warrant concerns about toxicity to fish and accelerated eutrophication. Recent improvements in wastewater treatment have decreased ammonia concentrations downstream from some urban areas, but the result has been an increase in nitrate concentrations. Information on environmental factors that affect water quality is useful to identify drainage basins throughout the Nation with the greatest vulnerability for nutrient contamination and to delineate areas where ground-water or surface-water contamination is most likely to oc

Water-Resources Investigations Report↗

Numerical simulation of ground-water flow in La Crosse County, Wisconsin, and into nearby pools of the Mississippi River

This report describes a two-dimensional regional screening model and two associated three-dimensional ground-water flow models that were developed to simulate the ground-water flow systems in La Crosse County, Wisconsin, and Pool 8 of the Mississippi River. Although the geographic extents of the three-dimensional models were slightly different, both were derived from the same geologic interpretation and regional screening model, and their calibrations were performed concurrently. The objectives of the La Crosse County (LCC) model were to assess the effects of recent (1990s) and potential future ground-water withdrawals and to provide a tool suitable to evaluate the effects of proposed water-management programs. The Pool 8 model objectives were to quantify the magnitude and distribution of ground-water flow into the Pool. The Wisconsin Geological and Natural History Survey and the U.S. Geological Survey developed the models cooperatively. The report describes: 1) the conceptual hydrogeologic model; 2) the methods used in simulating flow; 3) model calibration and sensitivity analysis; and 4) model results, such as simulation of predevelopment conditions and location and magnitude of ground-water discharge into Pool 8 of the Mississippi. Three aquifer units underlie the model area: 1) a shallow unconsolidated sand and gravel aquifer; 2) an upper bedrock aquifer, composed of Cambrian and Ordovician sandstone and dolomite; and 3) a lower bedrock aquifer composed of Cambrian sandstone of the Eau Claire Formation and the Mount Simon Formation. A shale layer that is part of the Eau Claire Formation forms a confining unit separating the upper and lower bedrock aquifers. This confining unit is absent in the Black River and parts of the La Crosse and Mississippi River valleys. Precambrian crystalline basement rock forms the lower base of the ground-water flow system. The U.S. Geological Survey ground-water flow model code, MODFLOW, was used to develop the La Crosse County (LCC) and Pool 8 ground-water flow models. Boundary conditions for the MODFLOW model were extracted from an analytic element screening model of the regional flow system surrounding La Crosse County. Model input was obtained from previously published and unpublished geologic and hydrologic data. Pumpages from municipal and high-capacity wells were also simulated. Model calibration included a comparison of modeled and field-measured water levels and field-measured base flows to simulated stream flows. At calibration, most measured water levels compared favorably to model-calculated water levels. Simulated streamflows at two targets were within 3 percent of estimated measured base flows. Mass balance results from the LCC and Pool 8 models indicated that 63 to 74 percent of ground water was from recharge and 19 to 26 percent was from surface-water sources. Ground-water flow out of the model was to rivers and streams (85 to 87 percent) and pumping wells (11 and 13 percent). The model demonstrates the effects of development on ground water in the study area. The maximum simulated water-level decline in the city of La Crosse metropolitan area is 9.3 feet. Simulated stream losses are similar to the amount of ground water pumped by wells. This indicates that ground water withdrawn by La Crosse County wells is water that under predevelopment conditions discharged to streams and lakes. The models provide estimates of the locations and amount of ground-water flow into Pool 8 and the southern portion of Pool 7 of the Mississippi River. Ground-water discharges into all areas of the pools, except along the eastern shore in the vicinity of the city of La Crosse and immediately downgradient from lock and dam 7 and 8. Ground-water flow into the pools is generally greatest around the perimeter with decreasing amounts away from the perimeter. An area of relatively high ground-water discharge extends out towards the center of Pool 7 from the upper reaches of the pool and may

Wisconsin↗

Hydrology of the Helena area bedrock, west-central Montana, 1993-98

The Generalized Bedrock Geologic Map of the Helena Area, West-Central Montana (plate 1 in the report) provides an intermediate-scale overview of bedrock in the Helena area. The geologic map has been compiled at a scale of 1:100,000 from the most widely available sources of geologic map information (see index to geologic mapping on pl. 1). That information has been updated by M.W. Reynolds for this report with more recent geologic mapping and field revision of published maps. All well locations and all bedrock units penetrated during drilling have been confirmed on geologic maps at the largest scale available. Source geologic maps are all at scales larger than 1:100,000 scale. Care has been taken to ensure accurate representation of the original geology at the compilation scale. However, positional accuracy of some features might be somewhat diminished at the smaller scale of the base map when compared with the original data source. Also, line thicknesses for contacts and faults necessarily assume a greater width, relative to the real geologic feature, at the scale of the generalized map than on any original map. The map is not intended for large-scale, site-specific detailed planning. Bedrock units throughout the Helena area are generally covered by young surficial deposits such as alluvium, colluvium, glacial debris, or windblown sediment. Thickness of such deposits varies from veneers through which the underlying bedrock is clearly discernible to major thicknesses that conceal all underlying bedrock and structure. Boundaries of major accumulations of surficial deposits are attributed separately from bedrock contacts. These boundaries should not be considered precise at the map scale or at larger scales. Boundaries shown may be less accurate positionally than bedrock contacts and faults because (1) surficial deposits commonly thin to a knife edge; (2) different mappers will interpret the edge differently when drawing a boundary; or (3) the original geologic map maker was concerned principally with bedrock units and structure and thus overlooked, or did not originally map as consistently, some surficial deposits. Veneers of surficial sediment, when saturated, can be local sources of recharge to underlying bedrock. Use of the generalized map to define their distribution does not substitute for site specific mapping of such deposits. Specific knowledge is needed to determine the water-bearing properties of the geologic units at and surrounding a site because the units, including the igneous and metamorphic rocks, have internal differences in stratigraphy, composition, mineralogy and grain size or crystallinity. These differences, together with structural imprints such as faults, folds, and the spacing, orientation, degree of openness of fractures, and extent and type of mineral filling in fractures and faults, all affect the ability of rocks to store and transmit water.

Montana↗

Reconnaissance investigation of water quality, bottom sediment, and biota associated with irrigation drainage in the American Falls Reservoir area, Idaho, 1988-89

Increased concern about the quality of irrigation drainage and its potential effects on human health, fish, and wildlife prompted the Department of the Interior to begin a program during late 1985 to identify irrigation-induced water-quality problems that might exist in the Western States. During `988, the Task Group on Irrigation Drainage selected the American Falls Reservoir area, Idaho, for study to determine whether potentially toxic concentrations of trace elements or organochlorine compounds existed in water, bottom sediment, and biota. The 91-square mile American Falls Reservoir has a total capacity of 1.7 million acre-feet and is used primarily for irrigation-water supply and power generation. Irrigated land upstream from the reservoir totals about 550,000 acres. Total water inflow to the reservoir is about 5.8 million acre-feet per year, of which about 63 percent is from surface-water runoff, 33 percent is from ground-water discharge, and about 4 percent is from ungaged tributaries, canals, ditches, sloughs, and precipitation. Ground-water discharge to the reservoir originates, in part, from irrigation of land upstream from and adjacent to the reservoir. The 1988 water year was a drought year, and water discharge was about 34 percent less than during 1939-88. Water samples were collected during the post-irrigation (October 1987) and irrigation (July 1988) seasons and were analyzed for major ions and trace elements. Bottom-sediment samples were collected during the irrigation season and were analyzed for trace elements and organochlorine compounds. Biota samples were collected during May, June, July, and August 1988 and were analyzed for trace elements and organochlorine compounds. Dissolved-solids concentrations in water ranged from 216 to 561 milligrams per liter. The similarity of dissolved-solids concentrations between the irrigation and post-irrigation seasons can be attributed to the large volume of ground-water discharge in the study area. Most trace-element concentrations in water were near analytical reporting limits; none exceeded State or Federal water-quality standards or criteria. Trace elements that were present at all sites in analytically detectable concentrations (in micrograms per liter) included arsenic (2 to 7), boron (40 to 130), uranium (0.7 to 3.5), vanadium (1 to 6) and zinc (less than 3 to 42). The ranges of arsenic, cadmium, and mercury concentrations in water analyzed during previous investigations. Selenium concentrations ranged from less than 1 (the reporting limit) to 6 micrograms per liter and did not exceed State of Federal water-quality standards or criteria. Concentrations of most trace elements in bottom sediment were similar to geometric mean concentrations in study area soils and were within the expected 95-percent range of concentrations in soils in the Western United States. Mercury concentrations in 9 of the 18 bottom-sediment samples exceeded the 95th-percentile concentration for mercury in area soils. Selenium concentration for selenium in area soils and, in 1 sample, exceeded the upper limit of the expected 95-percent range for selenium in Western United States soils. Most organochlorine compunds in bottom sediment were lower than analytical reporting limits. Only DDE (0.2 micrograms per kilogram) and DDT (0.3 micrograms per kilogram) were detected in bottom sediment from the Portneuf River. Except for mercury and selenium, concentrations of most trace elements in biota were not considered high enough to be harmful to humans or wildlife. Some mercury concentrations in fish exceeded the U.S. Fish and Wildlife Service National Contaminant Biomonitoring Program 85th-percentile concentration and were at levels that might not be safe for human consumption, especially for pregnant women. Elevated mercury concentrations in fish-eating waterbirds, such as double-crested cormorants, indicates biomagnification in the food chain. Selenium concentrations generally were low except in mallard livers (6.6 to 41.8 micrograms per gram, dry weight). This range is within the range of selenium concentrations (19 to 43 micrograms per gram, dry weight) reported in livers of ducks from Kesterson National Wildlife Refuge, California, where waterbird deformities, moralities, and reproductive impairment were observed. Selenium concentrations in mayfly nymphs were at or near dietary concentrations (5 to 8 micrograms per gram, dry weight) that had adverse reproductive effects on mallards during laboratory toxicity studies. p,p'DDE was detected in all waterbird eggs and juvenile mallared carcasses. Highest concentrations were in cormorant eggs (0.59 to 5.70 micrograms per gram, wet weight). p,p'DDE concentrations in four of five cormorant eggs exceeded the National Academy of Sciences, National Academy of Engineering criterion for protection of aquatic wildlife (1 microgram per gram, wet weight, for p,p'DDT and its metabolites). p,p'DDE was detected in all fish samples except rainbow trout. p,p'DDE was detected in one sample of Utah suckers. No concentrations of p,p'DDE or p,p'DDT in fish exceeded the criterion for protection of aquatic life. Total PCB's were detected in all cormorant eggs and all fish samples. PCB's were not detected in other waterbird eggs. PCB concentrations in cormorant eggs (0.28 to 1.8 micro per gram, wet weight) were lower than concentrations that would be expected to cause adverse effects. Two of the three carp samples contained PCB concntrations higher than the recommended level for protection of fish and wildlife (0.4 micrograms per gram, wet weight). Eggshell thinning was noted in cormorant and mallard eggs but was not considered great enough to cause reporductive problems. Observations of the general health of fish and waterbird populations during the study indicated that the area did not appear to have a serious contaminant problem that could be associated with irrigation grainage. No waterbird or fish die-offs were observed, and nesting waterbird populations were noted to be increasing. Selenium concentrations in mallard livers, however, are of concern, as are p,p'DDE residues in cormorant eggs.

Idaho↗

Ground-Water Hydrology of the Upper Deschutes Basin, Oregon

The upper Deschutes Basin is among the fastest growing regions in Oregon. The rapid population growth has been accompanied by increased demand for water. Surface streams, however, have been administratively closed to additional appropriation for many years, and surface water is not generally available to support new development. Consequently, ground water is being relied upon to satisfy the growth in water demand. Oregon water law requires that the potential effects of ground-water development on streamflow be evaluated when considering applications for new ground-water rights. Prior to this study, hydrologic understanding has been insufficient to quantitatively evaluate the connection between ground water and streamflow, and the behavior of the regional ground-water flow system in general. This report describes the results of a hydrologic investigation undertaken to provide that understanding. The investigation encompasses about 4,500 square miles of the upper Deschutes River drainage basin.A large proportion of the precipitation in the upper Deschutes Basin falls in the Cascade Range, making it the principal ground-water recharge area for the basin. Water-balance calculations indicate that the average annual rate of ground- water recharge from precipitation is about 3,500 ft3/s (cubic feet per second). Water-budget calculations indicate that in addition to recharge from precipitation, water enters the ground-water system through interbasin flow. Approximately 800 ft3/s flows into the Metolius River drainage from the west and about 50 ft3/s flows into the southeastern part of the study area from the Fort Rock Basin. East of the Cascade Range, there is little or no ground-water recharge from precipitation, but leaking irrigation canals are a significant source of artificial recharge north of Bend. The average annual rate of canal leakage during 1994 was estimated to be about 490 ft3/s. Ground water flows from the Cascade Range through permeable volcanic rocks eastward out into the basin and then generally northward. About one-half the ground water flowing from the Cascade Range discharges to spring-fed streams along the margins of the range, including the upper Metolius River and its tributaries. The remaining ground water flows through the subsurface, primarily through rocks of the Deschutes Formation, and eventually discharges to streams near the confluence of the Deschutes, Crooked, and Metolius Rivers. Substantial ground-water discharge occurs along the lower 2 miles of Squaw Creek, the Deschutes River between Lower Bridge and Pelton Dam, the lower Crooked River between Osborne Canyon and the mouth, and in Lake Billy Chinook (a reservoir that inundates the confluence of the Deschutes, Crooked, and Metolius Rivers).The large amount of ground-water discharge in the confluence area is primarily caused by geologic factors. North (downstream) of the confluence area, the upper Deschutes Basin is transected by a broad region of low-permeability rock of the John Day Formation. The Deschutes River flows north across the low-permeability region, but the permeable Deschutes Formation, through which most of the regional ground water flows, ends against this rampart of low-permeability rock. The northward-flowing ground water discharges to the streams in this area because the permeable strata through which it flows terminate, forcing the water to discharge to the surface. Virtually all of the regional ground water in the upper Deschutes Basin discharges to surface streams south of the area where the Deschutes River enters this low-permeability terrane, at roughly the location of Pelton Dam.The effects of ground-water withdrawal on streamflow cannot presently be measured because of measurement error and the large amount of natural variability in ground-water discharge. The summer streamflow near Madras, which is made up largely of ground-water discharge, is approximately 4,000 ft3/s. Estimated consumptive ground-water use in the basin i

Water-Resources Investigations Report↗

Flow-frequency characteristics of Vermont streams

The safe and economical design of infrastructure in and near waterways and the effective management of flood-hazard areas require information on streamflow that may not be readily available. This report provides estimates of flow-frequency characteristics for gaged streams in Vermont and describes methods for estimating flow-frequency characteristics for ungaged streams. The flow-frequency characteristics investigated are the magnitude of peak discharges at recurrence intervals of 2, 5, 10, 25, 50, 100, and 500 years, and the magnitude of daily-mean discharges exceeded 25, 50, and 75 percent of the time. Peak-flow frequency characteristics for gaged streams were computed following the guidelines in Bulletin 17B of the U.S. Interagency Advisory Committee on Water Data. To determine the peak-flow exceedance probabilities at stream-gaging stations in Vermont, a new generalized skew coefficient map for the State was developed. This new map has greater resolution and more current data than the existing National map. The standard error of the new map is 0.269. Two methods of extending streamflow record were applied to improve estimates of peak-flow frequency for streams with short flow records (10 to 15 years) in small drainage areas (sites less than 15 square miles). In the first method, a two-station comparison, data from a long-record site was used to adjust the frequency characteristics at the short-record site. This method was applied to 31 crest-stage gages--stations at which only instantaneous peak discharges are determined--in Vermont. The second method used rainfall-runoff modeling. Precipitation and evapotranspiration data from 1948 to 1999 for numerous climate data-collection sites were used as input to a model to simulate flows at 10 stream-gaging stations in Vermont. Also, methods are described to estimate flow-frequency characteristics for ungaged and unregulated rural streams in Vermont. The peak-flow estimating methods were developed by generalized-least-squares regression procedures with data from 138 U.S. Geological Survey stream-gaging stations in Vermont and in adjacent areas of New York, New Hampshire, Massachusetts, and Quebec. The flow-duration (daily flow exceeded a given percentage of the time) estimating methods were developed by ordinary-least-squares regression procedures with data from 81 stream-gaging stations in Vermont and adjacent states.

Vermont↗

Potential effects of structural controls and street sweeping on stormwater loads to the lower Charles River, Massachusetts

The water quality of the lower Charles River is periodically impaired by combined sewer overflows (CSOs) and non-CSO stormwater runoff. This study examined the potential non-CSO load reductions of suspended solids, fecal coliform bacteria, total phosphorus, and total lead that could reasonably be achieved by implementation of stormwater best management practices, including both structural controls and systematic street sweeping. Structural controls were grouped by major physical or chemical process; these included infiltration-filtration (physical separation), biofiltration-bioretention (biological mechanisms), or detention-retention (physical settling). For each of these categories, upper and lower quartiles, median, and average removal efficiencies were compiled from three national databases of structural control performance. Removal efficiencies obtained indicated a wide range of performance. Removal was generally greatest for infiltration-filtration controls and suspended solids, and least for biofiltration-bioretention controls and fecal coliform bacteria. Street sweeping has received renewed interest as a water-quality control practice because of reported improvements in sweeper technology and the recognition that opportunities for implementing structural controls are limited in highly urbanized areas. The Stormwater Management Model that was developed by the U.S. Geological Survey for the lower Charles River Watershed was modified to simulate the effects of street sweeping in a single-family land-use basin. Constituent buildup and washoff variable values were calibrated to observed annual and storm-event loads. Once calibrated, the street sweeping model was applied to various permutations of four sweeper efficiencies and six sweeping frequencies that ranged from every day to once every 30 days. Reduction of constituent loads to the lower Charles River by the combined hypothetical practices of structural controls and street sweeping was estimated for a range of removal efficiencies because of their inherent variability and uncertainty. This range of efficiencies, with upper and lower estimates, provides reasonable bounds on the load that could be removed by the practices examined. The upper estimated load reduction from combined street sweeping and structural controls, as a percentage of the total non-CSO load entering the lower Charles River downstream of Watertown Dam, was 44 percent for suspended solids, 34 percent for total lead, 14 percent for total phosphorus, and 17 percent for fecal coliform bacteria. The lower estimated load reduction from combined street sweeping and structural controls from non-CSO sources downstream of Watertown Dam, was 14 percent for suspended solids, 11 percent for total lead, 4.9 percent for total phosphorus, and 7.5 percent for fecal coliform bacteria. Load reductions by these combined management practices can be a small as 1.4 percent for total phosphorus to about 4 percent for the other constituents if the total load above Watertown Dam is added to the load from below the dam. Although the reductions in stormwater loads to the lower Charles River from the control practices examined appear to be minor, these practices would likely provide water-quality benefits to portions of the river during those times that they are most impaired-during and immediately after storms. It should also be recognized that only direct measurements of changes in stormwater loads before and after implementation of control practices can provide definitive evidence of the beneficial effects of these practices on water-quality conditions in the lower Charles River.

Massachusetts↗