Geology Reports⌕ Search

SEARCH · Geology Reports

Results for “Sensors”

Search indexed USGS publications on groundwater, aquifers, geologic maps, mineral resources and earthquakes. Explore source records by subject and place.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88Linked to original sources

USGS Polar Temperature Logging System, Description and Measurement Uncertainties

This paper provides an updated technical description of the USGS Polar Temperature Logging System (PTLS) and a complete assessment of the measurement uncertainties. This measurement system is used to acquire subsurface temperature data for climate-change detection in the polar regions and for reconstructing past climate changes using the 'borehole paleothermometry' inverse method. Specifically designed for polar conditions, the PTLS can measure temperatures as low as -60 degrees Celsius with a sensitivity ranging from 0.02 to 0.19 millikelvin (mK). A modular design allows the PTLS to reach depths as great as 4.5 kilometers with a skid-mounted winch unit or 650 meters with a small helicopter-transportable unit. The standard uncertainty (uT) of the ITS-90 temperature measurements obtained with the current PTLS range from 3.0 mK at -60 degrees Celsius to 3.3 mK at 0 degrees Celsius. Relative temperature measurements used for borehole paleothermometry have a standard uncertainty (urT) whose upper limit ranges from 1.6 mK at -60 degrees Celsius to 2.0 mK at 0 degrees Celsius. The uncertainty of a temperature sensor's depth during a log depends on specific borehole conditions and the temperature near the winch and thus must be treated on a case-by-case basis. However, recent experience indicates that when logging conditions are favorable, the 4.5-kilometer system is capable of producing depths with a standard uncertainty (uZ) on the order of 200-250 parts per million.

Techniques and Methods↗

Computing discharge using the index velocity method

Application of the index velocity method for computing continuous records of discharge has become increasingly common, especially since the introduction of low-cost acoustic Doppler velocity meters (ADVMs) in 1997. Presently (2011), the index velocity method is being used to compute discharge records for approximately 470 gaging stations operated and maintained by the U.S. Geological Survey. The purpose of this report is to document and describe techniques for computing discharge records using the index velocity method. Computing discharge using the index velocity method differs from the traditional stage-discharge method by separating velocity and area into two ratings—the index velocity rating and the stage-area rating. The outputs from each of these ratings, mean channel velocity (V) and cross-sectional area (A), are then multiplied together to compute a discharge. For the index velocity method, V is a function of such parameters as streamwise velocity, stage, cross-stream velocity, and velocity head, and A is a function of stage and cross-section shape. The index velocity method can be used at locations where stage-discharge methods are used, but it is especially appropriate when more than one specific discharge can be measured for a specific stage. After the ADVM is selected, installed, and configured, the stage-area rating and the index velocity rating must be developed. A standard cross section is identified and surveyed in order to develop the stage-area rating. The standard cross section should be surveyed every year for the first 3 years of operation and thereafter at a lesser frequency, depending on the susceptibility of the cross section to change. Periodic measurements of discharge are used to calibrate and validate the index rating for the range of conditions experienced at the gaging station. Data from discharge measurements, ADVMs, and stage sensors are compiled for index-rating analysis. Index ratings are developed by means of regression techniques in which the mean cross-sectional velocity for the standard section is related to the measured index velocity. Most ratings are simple-linear regressions, but more complex ratings may be necessary in some cases. Once the rating is established, validation measurements should be made periodically. Over time, validation measurements may provide additional definition to the rating or result in the creation of a new rating. The computation of discharge is the last step in the index velocity method, and in some ways it is the most straight-forward step. This step differs little from the steps used to compute discharge records for stage-discharge gaging stations. The ratings are entered into database software used for records computation, and continuous records of discharge are computed.

Techniques and Methods↗

Stage measurement at gaging stations

Stream and reservoir stage are critical parameters in the computation of stream discharge and reservoir volume, respectively. In addition, a record of stream stage is useful in the design of structures that may be affected by stream elevation, as well as for the planning for various uses of flood plains. This report describes equipment and methodology for the observation, sensing, and recording of stage in streams and reservoirs. Although the U.S. Geological Survey (USGS) still uses the traditional, basic stilling-well float system as a predominant gaging station, modern electronic stage sensors and water-level recorders are now commonly used. Bubble gages coupled with nonsubmersible pressure transducers eliminate the need for stilling wells. Submersible pressure transducers have become common in use for the measurement of stage in both rivers and lakes. Furthermore, noncontact methods, such as radar, acoustic, and laser methods of sensing water levels, are being developed and tested, and in the case of radar, are commonly used for the measurement of stage. This report describes commonly used gaging-station structures, as well as the design and operation of gaging stations. Almost all of the equipment and instruments described in this report will meet the accuracy standard set by the USGS Office of Surface Water (OSW) for the measurement of stage for most applications, which is ±0.01 foot (ft) or 0.2 percent of the effective stage. Several telemetry systems are used to transmit stage data from the gaging station to the office, although satellite telemetry has become the standard. These telemetry systems provide near real-time stage data, as well as other information that alerts the hydrographer to extreme or abnormal events, and instrument malfunctions.

Techniques and Methods↗

Chapter A6. Section 6.2. Dissolved oxygen

Accurate data for the concentration of dissolved oxygen in surface and ground waters are essential for documenting changes in environmental water resources that result from natural phenomena and human activities. Dissolved oxygen is necessary in aquatic systems for the survival and growth of many aquatic organisms and is used as an indicator of the health of surface-water bodies. This section of the National Field Manual (NFM) includes U.S. Geological Survey (USGS) guidance and protocols for four methods to determine dissolved-oxygen concentrations: the amperometric, luminescent-sensor, spectrophotometric, and iodometric (Winkler) methods. Each chapter of the National Field Manual is published separately and revised periodically. Newly published and revised chapters will be announced on the USGS Home Page on the World Wide Web under 'New Publications of the U.S. Geological Survey.'

Techniques of Water-Resources Investigations↗

Total dissolved gas and water temperature in the lower Columbia River, Oregon and Washington, 2002: Quality-assurance data and comparison to water-quality standards

Significant Findings The U.S. Geological Survey (USGS), in cooperation with the U.S. Army Corps of Engineers, collected total-dissolved-gas and water-temperature data at eight sites near dams on the lower Columbia River in 2002. When water is released through the spillways of dams, air is entrained in the water, increasing the concentration of total dissolved gas to levels that can have adverse effects on freshwater aquatic life. Significant findings include: For the eight monitoring sites in water year 2002, an average of 99.6% of the total-dissolved gas data were received in real time by the USGS satellite downlink and were within 1% saturation of the expected value, based on calibration data and ambient river conditions at adjacent sites. Most field checks of total-dissolved-gas sensors with a secondary standard were within 1% saturation. Field checks of barometric pressure and water temperature were usually within 1 millimeter of mercury and 0.05 degrees Celsius, respectively. In June and July 2002, spills exceeded 140,000 cubic feet per second at the John Day, The Dalles, and Bonneville Dams. These spills resulted in levels of total dissolved gas that exceeded 120% saturation downstream of the dams. The variance to the State of Oregon water-quality standard for total dissolved gas of 110% saturation was exceeded at seven of the eight monitoring sites. The sites at Camas and Bonneville are considered forebay sites and had the most days exceeding the variance of 115% saturation. The forebay exceedances may have been the result of the cumulative effects of significant spill throughout the lower Columbia River. Apparently, the levels of total dissolved gas did not dissipate rapidly enough downstream of the dams before reaching the next site. From mid-July to mid-September, water temperatures were usually above 20 degrees Celsius at each of the seven lower Columbia River sites in operation. According to the Oregon water-quality standard, when the temperature of the lower Columbia River exceeds 20 degrees Celsius, no measurable temperature increase resulting from anthropogenic activities is allowed.

Oregon, Washington↗

Attenuation of runoff and chemical loads in grass filter strips at two cattle feedlots, Minnesota, 1995-98

Attenuation of cattle feedlot runoff in two grass-covered filter strips in Minnesota was estimated by measuring chemical loads into and out of the strips. Filter strips of the Bock and Sanborn sites were 60-m long and 20-m wide and received runoff from cattle feedlots that supported 35 and 225 cattle, respectively. Feedlot and filter-strip runoff were measured using flumes with stage sensors. Water samples were collected using automated samplers. Attenuation values were calculated from four storm-runoff events. Ground water sampled beneath and outside the filter strips indicated some infiltration losses of sulfate, chloride, and nitrogen at the Bock site where soil permeability was greater than at the Sanborn site. Chemical constituents in filter-strip runoff, and their corresponding ranges of attenuation were as follows: chemical oxygen demand, 30–81 percent; dissolved chloride, 6–79 percent; dissolved sulfate, -3–82 percent; dissolved ammonia nitrogen, 33–80 percent; suspended ammonia plus organic nitrogen, 29–85 percent; dissolved organic nitrogen, 14–75 percent; suspended phosphorus, 24–82 percent; dissolved phosphorus, 14–72 percent; and fecal coliform bacteria, 18–79 percent. The ranges seem to be affected by barriers of direct contact of the runoff water with the soil. This varies seasonally by coverage of the soil by ice in winter and vegetation in summer months. Greater attenuation values occurred in October and May when mats of wilted, flat-lying grass covered the filter strips; attenuation values were less during the summer when tall growing grass covered the filter strips.

Minnesota↗

Mass balance, meteorology, area altitude distribution, glacier-surface altitude, ice motion, terminus position, and runoff at Gulkana Glacier, Alaska, 1996 balance year

The 1996 measured winter snow, maximum winter snow, net, and annual balances in the Gulkana Glacier Basin were evaluated on the basis of meteorological, hydrological, and glaciological data. Averaged over the glacier, the measured winter snow balance was 0.87 meter on April 18, 1996, 1.1 standard deviation below the long-term average; the maximum winter snow balance, 1.06 meters, was reached on May 28, 1996; and the net balance (from August 30, 1995, to August 24, 1996) was -0.53 meter, 0.53 standard deviation below the long-term average. The annual balance (October 1, 1995, to September 30, 1996) was -0.37 meter. Area-averaged balances were reported using both the 1967 and 1993 area altitude distributions (the numbers previously given in this abstract use the 1993 area altitude distribution). Net balance was about 25 percent less negative using the 1993 area altitude distribution than the 1967 distribution. Annual average air temperature was 0.9 degree Celsius warmer than that recorded with the analog sensor used since 1966. Total precipitation catch for the year was 0.78 meter, 0.8 standard deviations below normal. The annual average wind speed was 3.5 meters per second in the first year of measuring wind speed. Annual runoff averaged 1.50 meters over the basin, 1.0 standard deviation below the long-term average. Glacier-surface altitude and ice-motion changes measured at three index sites document seasonal ice-speed and glacier-thickness changes. Both showed a continuation of a slowing and thinning trend present in the 1990s. The glacier terminus and lower ablation area were defined for 1996 with a handheld Global Positioning System survey of 126 locations spread out over about 4 kilometers on the lower glacier margin. From 1949 to 1996, the terminus retreated about 1,650 meters for an average retreat rate of 35 meters per year.

Water-Resources Investigations Report↗

Relations among floodplain water levels, instream dissolved-oxygen conditions, and streamflow in the lower Roanoke River, North Carolina, 1997-2001

The lower Roanoke River corridor in North Carolina contains a floodplain of national significance. Data from a network of 1 streamflow-measurement site, 13 river-stage sites, 13 floodplain water-level sites located along 4 transects, and 5 in situ water-quality monitoring sites were used to characterize temporal and spatial variations of floodplain and river water levels during 1997-2000 and to describe dissolved-oxygen conditions in the lower Roanoke River for the period 1998-2001. Major differences in the relation of floodplain inundation to flow occurred both among sites at a given transect and among transects. Several floodplain sites were inundated for the full range of flow conditions measured during the study. These included one site on the Big Swash transect (at about river kilometer 119); one site on the Broadneck Swamp transect (river kilometer 97), which was inundated 91 percent of the time during the study; one site on the Devils Gut transect (river kilometer 44), which was inundated throughout the study; and three sites on the Cow Swamp transect (near river kilometer 10). The relation of floodplain inundation depth to Roanoke River flow was highly variable among sites. There was no relation between flow and inundation depth at one of the Big Swash sites or at any of the four Cow Swamp sites. At two of the Big Swash transect sites, there was some relation between inundation depth and 10-day mean flow for flows greater than 700 cubic meters per second. A relatively strong relation between inundation depth and 10-day mean flow occurred at two of the Broadneck Swamp sites and, to a lesser degree, at two of the Devils Gut transect sites. There was much greater interannual variability in floodplain water levels, as represented by the difference between the maximum and minimum daily water level for a given calendar date during January-May and September-October than during the summer and late fall months. If data from this study are representative of long-term conditions, then this means that there is less uncertainty about what future floodplain water levels will be during June-August and November-December than during other months. Rates of ground-water decline, primarily due to evapotranspiration, were fairly similar at all sites, ranging from about 3 to 4 centimeters per day. For a 10-day mean flow of 300 cubic meters per second, an evaporative loss of 2 centimeters per day is equal to about 56 cubic meters per second. Evapotranspiration rates are much lower during the fall and winter months, so losses of river flow to floodplain processes likely are much lower during those months. The ground-water gradient at most sites was from the floodplain to the river, indicating a potential for ground-water movement into the river from the floodplain. At two of the Devils Gut sites, however, the water level often was higher in the river than in the floodplain when floodplain sites were not inundated. This indicates that there is a potential for river water to move as ground water from the river into the floodplain. It seems likely that this feature observed at the Devils Gut transect occurs elsewhere in the lower Roanoke River corridor. Dissolved-oxygen concentrations typically decrease with increasing distance from Roanoke Rapids Dam. During the 1998-2001 study period, the median dissolved-oxygen concentration at Halifax (river kilometer 187), the upstream-most station, was 8.4 milligrams per liter, and the median concentration at the downstream-most station (NC-45, bottom sensor; river kilometer 2.6) was 6.6 milligrams per liter. Several synoptic measurements of dissolved-oxygen concentration down the river identified the presence of a dissolved-oxygen sag in the vicinity of Halifax, with some recovery of concentrations between Halifax and about Scotland Neck at river kilometer 156. Data from the synoptic measurements also indicated that the greatest rate of dissolved-oxygen change with distance along the riv

North Carolina↗

Total dissolved gas and water temperature in the lower Columbia River, Oregon and Washington, 2003: Quality-assurance data and comparison to water-quality standards

Significant Findings When water is released through the spillways of dams, air is entrained in the water, increasing the concentration of total dissolved gas. Excess dissolved-gas concentrations can have adverse effects on freshwater aquatic life. The U.S. Geological Survey (USGS), in cooperation with the U.S. Army Corps of Engineers, collected total- dissolved-gas and water-temperature data at seven sites on the lower Columbia River in 2003. Significant findings from the data include: For the seven monitoring sites in water year 2003, an average of 98.9% of the total-dissolved-gas data were received in real time by the USGS satellite downlink and were within 1% saturation of the expected value, based on calibration data, replicate quality-control measurements in the river, and comparison to ambient river conditions at adjacent sites. Most field checks of total-dissolved-gas sensors with a secondary standard were within plus or minus 1% saturation. Field checks of barometric pressure and water temperature were usually within plus or minus 1 millimeter of mercury and plus or minus 0.1 degree Celsius, respectively. The variances to the States of Oregon and Washington water-quality standards for total dissolved gas were exceeded at six of the seven monitoring sites. The sites at Camas and Bonneville forebay had the most days exceeding the variance of 115% saturation. The forebay exceedances may have been the result of the cumulative effects of supersaturated water moving downstream through the lower Columbia River. Apparently, the levels of total dissolved gas did not decrease rapidly enough downstream from the dams before reaching the next site. From mid-July to mid-September, water temperatures were usually above 20 degrees Celsius at each of the seven lower Columbia River sites. According to the Oregon water-quality standard, when the temperature of the lower Columbia River exceeds 20 degrees Celsius, no measurable temperature increase resulting from anthropogenic activities is allowed. Transient increases of about 1 degree Celsius were noted at the John Day forebay site, due to localized solar heating.

Oregon, Washington↗

Design, operation, and monitoring capability of an experimental artificial-recharge facility at East Meadow, Long Island, New York

Artificial recharge with tertiary-treated sewage is being tested at East Meadow to evaluate the physical and chemical effects on the groundwater system. The recharge facility contains 11 recharge basins and 5 injection wells and is designed to accept 4 million gallons of reclaimed water per day. Of the 11 basins, 7 are recently constructed and will accept 0.5 million gallons per day each. An observation manhole (12-foot inside diameter and extending 16 feet below the basin floor) was installed in each of two basins to enable monitoring and sampling of percolating reclaimed water in the unsaturated zone with instruments such as tensiometers, gravity lysimeters, thermocouples, and soil-gas samplers. Five shallow (100-feet deep) injection wells will each return 0.5 million gallons per day to the groundwater reservoir. Three types of injection-well design are being tested; the differences are in the type of gravel pack around the well screen. When clogging at the well screen occurs, redevelopment should restore the injection capability. Flow to the basins and wells is regulated by automatic flow controllers in which a desired flow rate is maintained by electronic sensors. Basins can also operate in a constant-head mode in which a specified head is maintained in the basin automatically. An observation-well network consisting of 2-inch- and 6-inch-diameter wells was installed within a 1-square-mile area at the recharge facility to monitor aquifer response and recharge. During 48 days of operation within a 17-week period (October 1982 through January 1983), 88.5 million gallons of reclaimed water was applied to the shallow water table aquifer through the recharge basins. A 4.29-foot-high groundwater mound developed during a 14-day test; some water level increase associated with the mound was detected 1,000 ft from the basins. Preliminary water quality data from wells affected by reclaimed water show evidence that mechanisms of mixing, dilution, and dispersion are affecting chemical concentrations of certain constituents, such as nitrogen and trichloroethane, in the shallow aquifer beneath the recharge area. (USGS)

Water-Resources Investigations Report↗

An assessment of the variability in performance of wet atmospheric deposition samplers

The variability in performance of two brands of wet/dry atmospheric deposition samplers were compared for 1 year at a sincle site. A total of nine samplers were used. Samples were collected weekly and analyzed for pH, specific conductance, common chemical constituents, and sample volume. Additionally, data on the duration of each sampler opening were recorded using a microdatalogger. These data disprove the common perception that samplers remain open throughout a precipitation event. The sensitivity of sampler sensors within the range tested did not have a defineable impact on sample collection. The nonnormal distribution within the data set necessitated application of the nonparametric Friedman Test to assess comparability of sample chemical composition and volume between and within sampler brands. Statistically significant differences existed for most comparisons, however the test did not permit quantification of their magnitudes. Differences in analyte concentrations between samplers were small. (USGS)

Water-Resources Investigations Report↗

Summary of sediment resuspension monitoring activities, Old Tampa Bay and Hillsborough Bay, Florida, 1988-91

Sediment resuspension was studied in Old Tampa BaY, the northwestern subembayment of Tampa Bay, and in Hillsborough Bay, the northeastern subembayment of Tampa Bay located along the coast of west-central Florida. Electromagnetic current meters, optical backscatterance sensors, and water samples were used to collect sediment resuspension data at several study sites in the two bays. This report describes the data-collection methods and summaries sediment resuspension data collected intermittently from October 1988 through December 1990 in Old Tampa Bay and from March 1990 through September 1991 in Hillsborough Bay. Example data are presented for selected monitoring events.

Water-Resources Investigations Report↗

Water movement in the unsaturated zone at a low-level radioactive-waste burial site near Barnwell, South Carolina

Four unsaturated-zone monitoring sites and a meteorologic station were installed at the low-level radioactive-waste burial site near Barnwell, S.C., to investigate the geohydrologic and climatologic factors affecting water movement in the unsaturated zone. The study site is located in the Atlantic Coastal Plain. The unsaturated zone consists of a few centimeters to more than 1 meter of surface sand, underlain by up to 15 meters of clayey sand. Two monitoring sites were installed in experimental trenches, and two were installed in radioactive-waste trenches. Two different trench designs were evaluated at the monitoring sites. A meteorologic station was used to measure precipitation and to calculate actual evapotranspiration using the Bowen ratio method. Soil-moisture tensiometers, soil-moisture conductance probes, and temperature sensors were used to monitor soil-water movement in and adjacent to the trenches. Tracer tests using sodium chloride were conducted at each monitoring site. Hydrologic properties of unsaturated-zone materials were also determined. Data collection at the monitoring sites began in January 1982 and continued until early May 1984. Tensiometer data show that the unsaturated materials had their highest percent saturations in winter and spring. Saturations in the backfill sand varied from 20 to 100 percent, and in the adjacent undisturbed and overlying compacted clayey sand, from about 75 to 100 percent. The same pattern generally was observed at all four monitoring sites. The tracer-test data indicate that water movement occurred mainly during the recharge period, winter and spring. The tracer-test results enabled computation of rates of unsaturated flow in the compacted clayey-sand cap, the compacted clayey-sand barrier, and the backfill sand. A micro-scale hydrologic budget was determined for an undisturbed part of the site from July 1983 through June 1984.Total precipitation was 144 centimeters, and actual evapotranspiration was 101 centimeters. Additionally, because tensiometer data indicate negligible water-storage changes in the unsaturated zone, it is estimated that approximately 43 centimeters of recharge reached the water table. During 1984, the rise and fall of ponded water in an experimental trench was continuously monitored with a digital recorder. This water-level record was used to compute the rate of leakage of ponded water from that trench--1 x 10 -5 centimeter per second. A cross-sectional finite-element model of variably saturated flow was used to test the conceptual model of water movement in the unsaturated zone and to illustrate the effect of trench design on water movement into the experimental trenches. Monitoring and model results show that precipitation on trenches infiltrated the trench cap and moved vertically into the trench backfill material. Precipitation on the undisturbed material adjacent to the trenches moved vertically through the surface sand and continued either downward into undisturbed clayey sand or laterally along the sand/clayey-sand interface into the backfill sand, depending on trench design. The trench construction practice of placing a compacted clayey-sand barrier around the trench greatly inhibits soil water from entering the trench.

South Carolina↗

A new high-precision borehole-temperature logging system used at GISP2, Greenland, and Taylor Dome, Antarctica

We describe a high-precision (0.1–1.0 mK) borehole-temperature (BT) logging system developed at the United States Geological Survey (USGS) for use in remote polar regions. We discuss calibration, operational and data-processing procedures, and present an analysis of the measurement errors. The system is modular to facilitate calibration procedures and field repairs. By interchanging logging cables and temperature sensors, measurements can be made in either shallow air-filled boreholes or liquid-filled holes up to 7 km deep. Data can be acquired in either incremental or continuous-logging modes. The precision of data collected by the new logging system is high enough to detect and quantify various thermal effects at the milli-Kelvin level. To illustrate this capability, we present sample data from the 3 km deep borehole at GISP2, Greenland, and from a 130 m deep air-filled hole at Taylor Dome, Antarctica. The precision of the processed GISP2 continuous temperature logs is 0.25–0.34 mK, while the accuracy is estimated to be 4.5 mK. The effects of fluid convection and the dissipation of the thermal disturbance caused by drilling the borehole are clearly visible in the data. The precision of the incremental Taylor Dome measurements varies from 0.11 to 0.32 mK. depending on the wind strength during the experiments. With this precision, we found that temperature fluctuations and multi-hour trends in the BT measurements correlate well with atmospheric-pressure changes.

Journal of Glaciology↗

Analysis of glacier facies using satellite techniques

The different snow and ice types on a glacier may be subdivided according to the glacier-facies concept. The surficial expression of some facies may be detected at the end of the balance year by the use of visible and near-infrared image data from the Landsat multispectral scanner (MSS) and thematic mapper (TM) sensors. Ice and snow can be distinguished by reflectivity differences in individual or ratioed TM bands on Brúarjökull, an outlet glacier on the northern margin of the Vatnajökull ice cap, Iceland. The Landsat scene shows the upper limit of wet snow on 24 August 1986. Landsat-derived reflectance is lowest for exposed ice and increases markedly at the transient snow line. Above the slush zone is a gradual increase in near-infrared reflectance as a result of decreasing grain-size of the snow, which characterizes drier snow. Landsat data are useful in measuring the areal extent of the ice facies, the slush zone within the wet-snow facies, the snow facies (combined wet-snow, percolation and dry-snow facies), and the respective positions of the transient snow line and the slush limit. In addition, fresh snowfall and/or airborne contaminants, such as soot and tcphra, can limit the utility of Landsat data for delineation of the glacier facies in some cases.

Journal of Glaciology↗

Numerical analysis of Landsat Thematic Mapper images of Antarctica

Landsat-5 Thematic Mapper (TM) data from Dronning [Queen] Maud Land, Antarctica, have been analysed to provide insights into physical properties of the ice sheet. Brightness (at-satellite) temperatures calculated from digital numbers of the thermal band (TM band 6), using state-of-the-art equations and constants ( Markham and Barker 1986 ), are 8° to 20°C lower than temperatures measured on the surface. Such differences cannot be ascribed to atmospheric absorption or to emissivity variations; instead, they suggest errors in either the sensor or instrument calibration for the temperature range 0° to −20°C. The results indicate an excess gain factor of about 1.63. The TM band 6 data seem to reproduce faithfully the relative temperature variations across the surface. Principal components (PCs) calculated for TM bands 2, 3, 4, 5, and 7 are presented for a region of the interior ice sheet. PCs are superior to individual bands or combinations of bands for analysing the main characteristics of an image, such as rendition of surface topography (mostly given in PCl), and for distinguishing between different surface materials (mostly given in PCs 2 and 3). Band ratioing was most useful for enhancing subtle albedo variations, such as those caused by changes in surface properties due to melting. TM data of the region, collected 18 d apart, show large changes on the snow surface; strong patterns shown in PC2 and TM bands 5 and 7 of the earlier image were nearly faded 18 d later. These strong patterns are not present at visual wavelengths or in the thermal band, and we believe they reflect wind-related variations in the physical properties of the snow.

Annals of Glaciology↗

West Florida shelf pipeline serves as sea turtle benthic habitat based on in-situ towed camera observations

The use of marine offshore benthic habitats by sea turtles is poorly characterized due to the difficulty of obtaining in situ data. Understanding benthic habitat use that is important to the species’ reproduction, foraging, and migrations is critical for guiding management decisions. A towed camera-based assessment survey system (C-BASS) equipped with environmental sensors was used to characterize and assess benthic habitats on the West Florida Shelf (WFS) from 2014 to 2018. During these cruises, sea turtles were opportunistically observed during the surveys, and critical in situ data such as spatiotemporal information, species identification, habitat use, behavior, and environmental data were collected and evaluated. In total, 79 sea turtles were observed during 97 transects of approximately 2700 km of seafloor, which was recorded on 380 h of video. Several sea turtle species were spotted within the WFS, including loggerhead Caretta caretta, Kemp’s ridley Lepidochelys kempii, and green turtles Chelonia mydas. These opportunistic sightings revealed an area of high use on the WFS, an anthropogenic structure known as the Gulfstream natural gas pipeline (GSPL). C-BASS survey results suggest that 2 sea turtle species (C. caretta and L. kempii) utilize this artificial structure primarily as a resting area. We emphasize the importance of combining habitat mapping techniques (towed underwater video and multibeam bathymetry/backscatter) with tracking technology to better understand the fine-scale habitat use of sea turtles.

Florida↗

Using tri-axial accelerometers to identify wild polar bear behaviors

Tri-axial accelerometers have been used to remotely identify the behaviors of a wide range of taxa. Assigning behaviors to accelerometer data often involves the use of captive animals or surrogate species, as their accelerometer signatures are generally assumed to be similar to those of their wild counterparts. However, this has rarely been tested. Validated accelerometer data are needed for polar bears Ursus maritimus to understand how habitat conditions may influence behavior and energy demands. We used accelerometer and water conductivity data to remotely distinguish 10 polar bear behaviors. We calibrated accelerometer and conductivity data collected from collars with behaviors observed from video-recorded captive polar bears and brown bears U. arctos , and with video from camera collars deployed on free-ranging polar bears on sea ice and on land. We used random forest models to predict behaviors and found strong ability to discriminate the most common wild polar bear behaviors using a combination of accelerometer and conductivity sensor data from captive or wild polar bears. In contrast, models using data from captive brown bears failed to reliably distinguish most active behaviors in wild polar bears. Our ability to discriminate behavior was greatest when species- and habitat-specific data from wild individuals were used to train models. Data from captive individuals may be suitable for calibrating accelerometers, but may provide reduced ability to discriminate some behaviors. The accelerometer calibrations developed here provide a method to quantify polar bear behaviors to evaluate the impacts of declines in Arctic sea ice.

Endangered Species Research↗