Geology Reports⌕ Search

SEARCH · Geology Reports

Results for “Electronics”

Search indexed USGS publications on groundwater, aquifers, geologic maps, mineral resources and earthquakes. Explore source records by subject and place.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,153 records · Page 64Linked to original sources

Report of the River Master of the Delaware River for the period December 1, 2013–November 30, 2014

Executive Summary A Decree of the Supreme Court of the United States, entered June 7, 1954 ( New Jersey v. New York , 347 U.S. 995), established the position of Delaware River Master within the U.S. Geological Survey. In addition, the Decree authorizes the diversion of water from the Delaware River Basin and requires compensating releases from specific reservoirs owned by New York City to be made under the supervision and direction of the River Master. The Decree stipulates that the River Master provide reports to the Court, not less frequently than annually. This report is the 61st annual report of the River Master of the Delaware River. The report covers the 2014 River Master report year, which is the period from December 1, 2013, to November 30, 2014. During the report year, precipitation in the upper Delaware River Basin was 42.40 inches or 95 percent of the long-term average. On December 1, 2013, combined useable storage in New York’s Pepacton, Cannonsville, and Neversink Reservoirs in the upper Delaware River Basin was 200.133 billion gallons or 73.9 percent of the combined capacity of 270.8 billion gallons. The reservoirs were at about 99.7 percent of usable capacity on May 31, 2014. Combined storage in the Pepacton, Cannonsville, and Neversink Reservoirs decreased below 80 percent of combined capacity in late August. The lowest combined storage was 151.730 billion gallons or 56 percent of combined capacity on November 24, 2014. Delaware River Master operations during the year were conducted as stipulated by the Decree and the Flexible Flow Management Program. Diversions from the Delaware River Basin by New York City and the State of New Jersey fully complied with the Decree. Reservoir releases were made as directed by the River Master at rates designed to meet the flow objective for the Delaware River at Montague, New Jersey, on 94 days during the report year. Interim Excess Release Quantity and conservation releases, designed to relieve thermal stress and protect the fishery and aquatic habitat in the tailwaters of the reservoirs, were also made during the report year. Water quality in the Delaware River estuary between streamgages at Trenton, New Jersey, and Reedy Island Jetty, Delaware, was monitored at several locations. Data on water temperature, specific conductance, dissolved oxygen, and pH were collected continuously by electronic instruments at four locations.

New Jersey, New York, Pennsylvania↗

Report of the River Master of the Delaware River for the period December 1, 2014–November 30, 2015

Executive Summary A Decree of the Supreme Court of the United States, entered June 7, 1954 ( New Jersey v. New York , 347 U.S. 995), established the position of Delaware River Master within the U.S. Geological Survey. In addition, the Decree authorizes the diversion of water from the Delaware River Basin and requires compensating releases from specific reservoirs owned by New York City be made under the supervision and direction of the River Master. The Decree stipulates that the River Master provide reports to the Court, not less frequently than annually. This report is the 62nd annual report of the River Master of the Delaware River. This report covers the 2015 River Master report year, which is the period from December 1, 2014, to November 30, 2015. During the report year, precipitation in the upper Delaware River Basin was 42.22 inches or 95 percent of the long-term average. The combined storage remained above 80 percent of the combined capacity until August 2015. The lowest combined storage of the report year was 57 percent of the total combined capacity on December 1, 2014. Delaware River Master operations during the year were conducted as stipulated by the Decree and the Flexible Flow Management Program. Diversions from the Delaware River Basin by New York City and New Jersey fully complied with the Decree. The reservoir releases were made as directed by the River Master at rates designed to meet the flow objective for the Delaware River at Montague, New Jersey, on 72 days during the report year. Interim Excess Release Quantity and conservation releases, designed to relieve thermal stress and protect the fishery and aquatic habitat in the tailwaters of the reservoirs, were also made during the report year. Water quality in the Delaware River estuary between the streamgages at Trenton, New Jersey, and Reedy Island Jetty, Delaware, was monitored at several locations. Data on water temperature, specific conductance, dissolved oxygen, and pH were collected continuously by electronic instruments at four sites.

Delaware, New Jersey New York, Pennsylvania↗

Summary of Creepmeter Data from 1980 to 2020—Measurements Spanning the Hayward, Calaveras, and San Andreas Faults in Northern and Central California

This report is an update to the presentation by Schulz (1989) introducing potential users to the creepmeter data collected between the publication of Schulz’s report and mid-2020. The creepmeter network monitors aseismic, surface slip at various locations on the Hayward, Calaveras, and San Andreas Faults in northern and central California. There are different designs of creepmeters and these are briefly described. For a majority of the creepmeters, these data are automatically sent to the U.S. Geological Survey (USGS) offices where they are stored and processed. In addition, for most of the creepmeters, occasional manual measurements are made and these are compared with digitally recorded data. For some sites, the comparisons indicated degradation of the electronic sensor and consequently corrections are made to the digital data. The largest transient deformation is that which followed the 2004, M6 , Parkfield earthquake. Various functions found in the literature that have been used to model postseismic slip were tested with the observed postseismic behavior seen on the creepmeters in the vicinity of Parkfield, California. No single function adequately fit all the data from these Parkfield instruments. This report is a discussion and analysis of data from creepmeters deployed by the USGS. The discussion primarily focuses on instruments that are currently operating in 2020 or have operated quite recently but are no longer in service.

California↗

Report of the River Master of the Delaware River for the period December 1, 2015 - November 30, 2016

Executive Summary A Decree of the Supreme Court of the United States, entered June 7, 1954 ( New Jersey v. New York , 347 U.S. 995), established the position of Delaware River Master within the U.S. Geological Survey. In addition, the Decree authorizes the diversion of water from the Delaware River Basin and requires compensating releases from reservoirs owned by New York City to be made under the supervision and direction of the River Master. The Decree stipulates that the River Master provide reports to the Court not less frequently than annually. This report is the 63rd annual report of the River Master of the Delaware River. The report covers the 2016 River Master report year, which is the period from December 1, 2015, to November 30, 2016. During the report year, precipitation in the upper Delaware River Basin was 38.6 inches or 87 percent of the long-term average. Combined storage remained high (above 80 percent of combined capacity) for much of the year and did not decline below 80 percent of combined capacity until August 2016. The lowest combined storage was 106.406 billion gallons or 39 percent of combined capacity on November 28, 2016. Delaware River Basin Commission Resolution 2016–07 necessitated a basinwide drought watch on November 23, 2016. The drought watch continued through the remainder of the 2016 report year. Delaware River Master operations during the year were conducted as stipulated by the Decree and the Flexible Flow Management Program. New York City and New Jersey fully complied with the terms of the Decree and, during drought watch conditions, with the Delaware River Basin Commission Resolution 2016–07 terms. Diversions from the Delaware River Basin by New York City and New Jersey fully complied with the Decree. The reservoir releases were made as directed by the River Master at rates designed to meet the flow objective for the Delaware River at Montague, New Jersey, on 126 days during the report year. Interim Excess Release Quantity and conservation releases, designed to relieve thermal stress and protect the fishery and aquatic habitat in the tailwaters of the reservoirs, were also made during the report year. Water quality in the Delaware River estuary between the streamgages at Trenton, New Jersey, and Reedy Island Jetty, Delaware, was monitored at several locations. Data on water temperature, specific conductance, dissolved oxygen, and pH were collected continuously by electronic instruments at four sites.

Delaware, Maryland, New Jersey, New York, Pennsylv↗

Report of the River Master of the Delaware River for the period December 1, 2016–November 30, 2017

Executive Summary A Decree of the Supreme Court of the United States, entered June 7, 1954 ( New Jersey v. New York , 347 U.S. 995), established the position of Delaware River Master within the U.S. Geological Survey. In addition, the Decree authorizes the diversion of water from the Delaware River Basin and requires compensating releases from certain reservoirs owned by New York City be made under the supervision and direction of the River Master. The Decree stipulates that the River Master provide reports to the Court, not less frequently than annually. This report is the 64th annual report of the River Master of the Delaware River. The report covers the 2017 River Master report year, from December 1, 2016, to November 30, 2017. During the report year, precipitation in the upper Delaware River Basin was 47.85 inches or 108 percent of the long-term average. On December 1, 2016, combined useable storage in the New York City reservoirs in the upper Delaware River Basin was 110.115 billion gallons or 40.7 percent of combined storage capacity, the lowest combined storage of the 2017 report year. The reservoirs were at about 100 percent of useable capacity on May 31, 2017. Combined storage remained above 80 percent of combined capacity until September 2017. A lower basin drought watch issued by the Delaware River Basin Commission in 2016 extended from the beginning of this report year to January 18, 2017. The drought watch was ended on January 18, 2017, due to increased precipitation in December 2016. River Master operations during the year were conducted as stipulated by the Decree and the Flexible Flow Management Programs. Diversions from the Delaware River Basin by New York City and New Jersey fully complied with the Decree. Reservoir releases were made as directed by the River Master at rates designed to meet the flow objective for the Delaware River at Montague, New Jersey (N.J.), on 52 days during the report year. Interim Excess Release Quantity and conservation releases, designed to relieve thermal stress and protect the fishery and aquatic habitat in the tailwaters of the reservoirs, were made during the report year. Excess Release Quantity and Interim Excess Release Quantity Bank releases were also made during the report year. The water quality in the Delaware River estuary between the streamgages at Trenton, N.J., and Reedy Island Jetty, Delaware, was monitored at various locations. The data on water temperature, specific conductance, dissolved oxygen, and pH were collected continuously by electronic instruments at four sites.

New Jersey, New York, Pennsylvania↗

Report on the operation of Barnaby, summer, 1948

Barnaby is a self-contained truck-mounted unit for gamma-ray logging of diamond drillholes less than 200 feet deep. The radiation is detected by Geiger-Muller counter and the impulses are transmitted up a single-conductor shielded cable by a special circuit. At the surface the impulses are electronically counted and the average counting rate is automatically plotted by a recording meter synchronized with the advance of the G-M counter in the hole. Barnaby was designed and built for the Union Mines Development Corp. by Robert J. Smith and the writer in the spring of 1945 at the shops of the Metallurgical Laboratories, University of Chicago.

Open-File Report↗

Preliminary report on the use of LANDSAT-1 (ERTS-1) reflectance data in locating alteration zones associated with uranium mineralization near Cameron, Arizona

LANDSAT-I (ERTS-I) multispectral reflectance data were used to enhance the detection of alteration around uranium deposits near Cameron, Ariz. The technique involved stretching and ratioing computer-enhanced data from which electronic noise and atmospheric haze had been removed. Using present techniques, the work proves that LANDSAT-I data are useful in detecting alteration around uranium deposits, but the method may still be improved. Bluish-gray mudstone in the target area could not be differentiated from the altered zones on the ratioed images. Further experiments involving combinations of ratioed and nonratioed data will be required to uniquely define the altered zones.

Open-File Report↗

Helium detection as a guide for uranium exploration

Helium, a byproduct of radioactive decay, may prove to be a valuable indicator of the presence and distribution of uranium deposits. Recent technological advances permit the development of instrumentation not previously adapted for this purpose. Commercially available equipment can provide high sensitivity at low cost and allow reasonable mobility for field use. A truck-mounted mass-spectrometer, tuned for helium-4, permits immediate adjustment or modification of sampling patterns in response to accumulating data. The inlet system of the spectrometer has been designed to allow flexibility in gas analyses from various sample types--soil gas, atmosphere, or gases in water. Sensitivity of the instrument is better than 50 parts of helium per 10 9 parts of gas. Replicate samples and standards can be analyzed in only 3 minutes. Helium in soil gas is being used for the initial evaluation of the technique. A hollow probe, as much as 2 m long, is driven into the ground; and a 10-cc syringe is used to purge the probe and extract the gas. This sample is then injected into the inlet system and introduced into the spectrometer at constant pressure. The output signal is displayed on a chart recorder. Investigations can be performed on a qualitative, relative basis, or on a quantitative basis by comparison to calibrated helium standards. Preliminary field testing includes studies of the responses to variations in wind speed, temperature, barometric pressure, moisture, and sampling depth over extended time periods, as well as studies of geologic controls on the helium content in soil gas. Surveys over known uranium occurrences reveal some anomalous helium distributions. This report describes an updated technological approach to an old idea: that of using helium, a byproduct of uranium radioactive decay, as an exploration tool for uranium. Helium is the sixth most abundant gas found in the earth's atmosphere (Table 1). It is an inert gas and very mobile, mixing rapidly. When the alpha particles from the radioactive decay of uranium and thorium pick up two electrons, atoms of the isotope helium-4 are formed. Several helium-4 atoms are produced from each decay series of U-238, U-235, and Th-232 (fig. 1). The half-lives of the parent isotopes are5also shown in figure 1. One gram of uranium will produce ~10 5 atoms of helium-4 per second, and one gram of thorium produces ~2.5 x 10 4 atoms of helium-4 per second (fig. 2). Calculations of the helium produced from the crust and mantle reveal that 1,125 x 10 30 atoms per year are produced, but only 7 x 10 30 atoms per year escape from the earth (Damon and Kulp, 1958). More is being produced than is being lost; in fact, the total atmospheric content of helium could be produced in only 2 million years (MacDonald, 1963)! However, all the crustal and mantle helium-4 does not degas into the atmosphere as it is formed. It is trapped in crystal lattices and in pore spaces within the earth. What this means is that there is excess helium-4 in the earth--excess, that is, compared to the atmospheric concentration in equilibrium with the helium-4 escape rate into space and the helium-4 flux from the crust and mantle (Nicolet, 1957). Near-surface pockets of high helium-4 concentrations are known, and some natural gas fields are so enriched that they are the source for commercial production of helium. Work by Roberts and others (1975) has shown high helium concentration in the soil gas associated with geothermal areas; and work by Clark and Kugler (1973), Dyck (1975), and Goldak (1974), for example, has noted high helium concentrations in soils and waters in the vicinity of uranium deposits. These latter studies certainly indicate the potential of helium detection for use as an exploration tool for uranium.

Open-File Report↗

Empirical transfer functions for stations in the Central California seismological network

A sequence of calibration signals composed of a station identification code, a transient from the release of the seismometer mass at rest from a known displacement from the equilibrium position, and a transient from a known step in voltage to the amplifier input are generated by the automatic daily calibration system (ADCS) now operational in the U.S. Geological Survey central California seismographic network. Documentation of a sequence of interactive programs to compute, from the calibration data, the complex transfer functions for the seismographic system (ground motion through digitizer) the electronics (amplifier through digitizer), and the seismometer alone are presented. The analysis utilizes the Fourier transform technique originally suggested by Espinosa et al (1962). Section I is a general description of seismographic calibration. Section II contrasts the 'Fourier transform' and the 'least-squares' techniques for analyzing transient calibration signals. Theoretical consideration for the Fourier transform technique used here are described in Section III. Section IV is a detailed description of the sequence of calibration signals generated by the ADCS. Section V is a brief 'cookbook description' of the calibration programs; Section VI contains a detailed sample program execution. Section VII suggests the uses of the resultant empirical transfer functions. Supplemental interactive programs by which smooth response functions, suitable for reducing seismic data to ground motion, are also documented in Section VII. Appendices A and B contain complete listings of the Fortran source Codes while Appendix C is an update containing preliminary results obtained from an analysis of some of the calibration signals from stations in the seismographic network near Oroville, California.

Open-File Report↗

Preliminary report on certain metals of potential economic interest in thin vanadium-rich zones in the Meade Park member of the Phosphoria Formation in western Wyoming and eastern Idaho

Electron microprobe, optical and chemical studies of fresh and weathered rocks permit preliminary conclusions concerning the concentration and mineralogical residence of certain elements of potential economic significance in thin, vanadium-rich zones in the Meade Peak Member of the Phosphoria Formation in western Wyoming and eastern Idaho. Elements of particular interest are V, Cr, Zn, Cd, Ag, Se, S, Ti, and Mo. Their principal mineralogical residence in fresh or unweathered rock has been established as follows: V is in, or associated with, organic material and minor amounts of V are in Ti-Fe oxysulfide and an unidentified Fe sulfide; Cr is in a 10 A mica. Zn and Cd are in sphalerite; Se is in pyrite; S is in pyrite, sphalerite and organic material; Ti is in TiO 2 and Ti 2 Fe(SO 3 ) 2 and Mo is in powellite. The principal minerals in fresh rocks are quartz, K-feldspar, albite, illite, calcite, and dolomite. Weathering or leaching by ground water removes pyrite, calcite, and dolomite. The leached rock sequences currently mined for phosphate may be amenable to extraction of the metals associated with the organic material.

Idaho, Wyoming↗

Regional and local networks of horizontal control, Cerro Prieto geothermal area, Mexico

The Cerro Prieto geothermal area in the Mexicali Valley 30 km southeast of Mexicali, Baja California, is probably deforming due to (1) the extraction of large volumes of steam and hot water, and (2) active tectonism. Two networks of precise horizontal control were established in Mexicali Valley by the U.S. Geological Survey in 1977-78 to measure both types of movement as they occur. These networks consisted of (1) a regional trilateration net brought into the mountain ranges west of the geothermal area from survey stations on an existing U.S. Geological Survey crustal-strain network north of the international border, and (2) a local net tied to stations in the regional net and encompassing the area of present and planned geothermal production. Survey lines in this net were selected to span areas of probable ground-surface movements in and around the geothermal area. Electronic distance measuring (EDM) instruments, operating with a modulated laser beam, were used to measure the distances between stations in both networks. The regional net was run using a highly precise long-range EDM instrument, helicopters for transportation of men and equipment to inaccessible stations on mountain peaks, and a fixed wing airplane flying along the line of sight. Precision of measurements with this complex long-range system approached 0.2 parts per million of line length. The local net was measured with medium range EDM instrument requiring minimal ancillary equipment. Precision of measurements with this less complex system approached 3 parts per million for the shorter line lengths. The detection and analysis of ground-surface movements resulting from tectonic strains or induced by geothermal fluid withdrawal is dependent on subsequent resurveys of these networks.

Baja California↗

The Earth Resources Observation Systems data center's training technical assistance, and applications research activities

The Earth Resources Observation Systems (EROS) Data Center (EDO, administered by the U.S. Geological Survey, U.S. Department of the Interior, provides remotely sensed data to the user community and offers a variety of professional services to further the understanding and use of remote sensing technology. EDC reproduces and sells photographic and electronic copies of satellite images of areas throughout the world. Other products include aerial photographs collected by 16 organizations, including the U.S. Geological Survey and the National Aeronautics and Space Administration. Primary users of the remotely sensed data are Federal, State, and municipal government agencies, universities, foreign nations, and private industries. The professional services available at EDC are primarily directed at integrating satellite and aircraft remote sensing technology into the programs of the Department of the Interior and its cooperators. This is accomplished through formal training workshops, user assistance, cooperative demonstration projects, and access to equipment and capabilities in an advanced data analysis laboratory. In addition, other Federal agencies, State and local governments, universities, and the general public can get assistance from the EDC Staff. Since 1973, EDC has contributed to the accelerating growth in development and operational use of remotely sensed data for land resource problems through its role as educator and by conducting basic and applied remote sensing applications research. As remote sensing technology continues to evolve, EDC will continue to respond to the increasing demand for timely information on remote sensing applications. Questions most often asked about EDC's research and training programs include: Who may attend an EDC remote sensing training course? Specifically, what is taught? Who may cooperate with EDC on remote sensing projects? Are interpretation services provided on a service basis? This report attempts to define the goals and objectives of and policies on the following EDC services: Training Program. User Assistance. Data Analysis Laboratory. Cooperative Demonstration Projects. Research Projects.

Open-File Report↗

Crustal deformation observatory: Part B, precision geodesy

The primary purpose of this investigation this past year was to establish and monitor a precise leveling array at Pinon Flat Geophysical Observatory to monitor tilt strain. The leveling array is one of several strain measurement techniques established at the observatory by several investigators for side-byside testing. Precise leveling is an optical method of measuring vertical strain in contrast to the various tiltmeters which measure electronically or electro-optically. The advantages of establishing several strain measuring techniques at one location is to obtain a high degree of redundancy so that the precision of each technique can be better evaluated. A secondary and on-going objective of the leveling is the observation of closely-spaced benchmarks to determine factors affecting their stability. Tectonic interpretations from analyses of historic levelings are frequently suspect because of benchmark instability (Karcz and others, 1976).

Open-File Report↗

A crustal deformation observatory near the San Andreas Fault in central California (PB3)

This final technical report discusses several objectives and accomplishments of the first years effort of a project titled A Crustal Deformation Observatory Near the San Andreas Fault in Central California. This period saw the conclusion of the Hollister MWDM effort that has produced nearly continuous, high precision, line length measurements for the last 5 years. The establishment of an observatory similar to that used during the Hollister MWDM effort is underway near San Juan Bautista and both high precision vertical and horizontal measurements will commence in the near future. An interim measurement program was begun near Palmdale in Southern California during October 1980 and is continuing at the present time. Extensive electronic modification to the MWDM instrument has also been successfully completed during this reporting period. Each of these efforts will be discussed in more detail in the following sections of this report.

California↗

Tilt networks of Mount Shasta and Lassen Peak, California

In response to recent eruptions at Mount St. Helens and with support from the USGS Volcanic Hazards Program, the Cascades Volcano Observatory (CVO) has initiated a program to monitor all potentially-active volcanoes of the Cascade Range. As part of that effort, we installed tilt networks and obtained baseline measurements at Mount Shasta and Lassen Peak, California during July 1981. At the same time, baseline electronic distance measurements (EDM) were made and fumarole surveys were conducted by other crews from CVO. Annual surveys are planned initially, with subsequent visits as conditions warrant. These geodetic and geochemical measurements supplement a program of continuous seismic monitoring of Cascade volcanoes by the USGS Office of Earthquake Studies in cooperation with local universities. Other tilt networks were established at Mount Baker in 1975 and at Mount St. Helens in 1981. EDM networks were established at Mount Baker in 1975, Mount St. Helens in 1980, and Crater Lake in 1981. Additional tilt and/or EDM networks are planned for Mount Rainier, Mount Hood, Glacier Peak, Three Sisters, and Crater Lake as funds permit.

Open-File Report↗

The Emma Bell deposit, Siskiyou Co., California: A possible low-grade source of chromite

The Emma Bell chromite deposit in Siskiyou County, California contains over 5 million tons of dunite averaging about 4 percent Cr 2 O 3 . Chromite is not evenly disseminated throughout the dunite, however. For the most part the deposit consists of many chromite-rich bands in sharp contact with, and separated by, common dunite containing 1 to 2 percent accessory chromite. Electron microprobe and petrographic analysis of accessory chromite shows that it is fine grained (average grain size 0.14 mm), generally lower in Cr 2 O 3 , and has a lower Cr/Fe ratio than segregated chromite. In addition, unusual patchy zoning is exhibited by some accessory chromite. These patchy zones are extremely rich in iron (>60 percent total iron oxide). The negative factors such as the fine-grained nature of the accessory chromite and high iron content compared to segregated chromite, could be overcome by the very large tonnage in the deposit.

California↗

Hydrologic data for Leviathan Mine and vicinity, Alpine County, California, 1981-83

The U.S. Geological Survey collected basic hydrologic and water-quality data during 1981-83 to facilitate the geohydrologic evaluation of the Leviathan Mine area and the design of a pollution-abatement project. Surface-water field data included one or more measurements of pH, water temperature, and specific conductance at 45 sites in and adjacent to the mine area. At nine of these sites, daily data on discharge, specific conductance, and water temperature were collected during parts of 1981-82 by using electronic monitor-recorder systems. Ground-water field data included one or more of the water-quality measurements listed above at 71 piezometers in the mine area. Borehole geophysical data included neutron-moisture, neutron-porosity, gamma-gamma density, natural gamma, and temperature logs at three sites. Mineralogic and hydrologic data were obtained for cores taken from nine test holes. One or more surface-water samples from 26 sites were analyzed for major cations, major anions, and a wide range of minor inorganic constituents. Single ground-water samples from 36 piezometers were analyzed for the same array of major and minor constituents. (USGS)

Open-File Report↗