Geology Reports⌕ Search

SEARCH · Geology Reports

Results for “Surveys in Geophysics”

Search indexed USGS publications on groundwater, aquifers, geologic maps, mineral resources and earthquakes. Explore source records by subject and place.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43Linked to original sources

Hydrogeological investigation at Site 5, Willow Grove Naval Air Station/Joint Reserve Base, Horsham Township, Montgomery County, Pennsylvania

The U.S. Geological Survey conducted borehole geophysical logging, collected and analyzed water-level data, and sampled sections of a rock core to determine the concentration of volatile organic compounds in the aquifer matrix of the Stockton Formation. Borehole geophysical logs were run in three monitor wells. At well 05MW04I, the vertical gradient was upward at depths above 42 feet below land surface (ft bls), downward between 42 and 82 ft bls, and upward below 82 ft bls. At well 05MW05I, a downward vertical gradient was present. At well 05MW12I, the vertical gradient was downward above 112 ft bls and upward below 112 ft bls. Three water-bearing fractures in a 17-foot long rock core from 23.5 to 40.5 ft bls were identified and sampled. Three samples were analyzed from each water-bearing fracture—at the fracture face, 2 centimeters (cm) below the fracture, and 4 cm below the fracture. Fifteen compounds were detected; however, concentrations of seven compounds were less than 1 microgram per kilogram (mg/kg) when detected. Concentrations of benzene (from 0.39 to 3.3 mg/kg), 1,1-dichloroethene (1,1-DCE) (from 0.15 to 13 mg/kg), 1,1,1-trichloroethane (TCA) (from 0.17 to 22 mg/kg), and trichloroethylene (TCE) (from 0.092 to 9.6 mg/kg) were detected in all samples. The highest concentrations detected were for toluene, which was detected at a concentration of 32 and 86 mg/kg in the samples from unweathered sandstone at 2 and 4 cm below the fracture, respectively. Concentrations generally decreased with distance below the fracture in the mudstone samples. Concentrations of benzene and toluene increased with distance below the fractures in the unweathered sandstone samples. Concentrations of 1,1-DCE, TCA, and TCE were higher in the mudstone samples than in the samples from sandstone. Toluene concentrations were higher in unweathered sandstone than in weathered sandstone or mudstone. The effect of the pumping of Horsham Water and Sewer Authority public supply well 26 (HWSA-26), 0.2 mile southwest of the base boundary, on groundwater levels on the base was determined by shutting the well down for 6 days to allow water levels to recover. Water levels in 22 nearby wells were measured. The only well (02MW01I) that showed an unambiguous response to the shutdown of well HWSA-26 is 1,350 feet directly along strike from well HWSA-26. The recovery of well 05MW11I in response to the shutdown of well HWSA-26 is masked by recharge from snowmelt but probably does not exceed about 0.2 feet on the basis of the water level in well 05MW11I, which showed a response to the pumping of well HWSA-26 that ranged from 0.5 to 0.15 foot. Horizontal gradients differ with depth, and the rate and direction of ground-water flow and contaminant movement is depth dependent. The potentiometric-surface map for water levels measured in wells screened between 5 and 44 ft bls in the aquifer shows a ground-water mound that is the high point on a regional ground-water divide. From this divide, ground water flows both northwest toward Park Creek and southeast toward Pennypack Creek. The hydraulic gradient around this mound is relatively flat to the southeast and particularly flat to the northwest. The potentiometric-surface map for water levels measured in wells screened between 40 and 100 ft bls in the aquifer shows a very flat hydraulic gradient. Differences in the elevation of the potentiometric surface are less than 2 feet. The potentiometric-surface map for water levels measured in wells screened between 105 and 179 ft bls in the aquifer shows a steep hydraulic gradient between Sites 5 and 2 and a relatively flat hydraulic gradient between Sites 5 and 3. Water levels measured on October 7, 1999, showed downward vertical head gradients for all well clusters at Site 5. Vertical gradients ranged from 0.01 at well cluster 05MW10 to 0.2 at cluster 05MW11. Most gradients were between 0.01 and 0.026. Vertical head gradients vary with time. The variability is caused by a difference in the magnitude of water-level fluctuations between shallow and the deep fractures. The difference in the magnitude of water-level fluctuations is because of differences in lithology and aquifer storativity.

Pennsylvania↗

Geophysical characterization of fractured bedrock at Site 8, former Pease Air Force Base, Newington, New Hampshire

Borehole-geophysical logs collected from eight wells and direct-current resistivity data from three survey lines were analyzed to characterize the fractured bedrock and identify transmissive fractures beneath the former Pease Air Force Base, Newington, N.H. The following logs were used: caliper, fluid temperature and conductivity, natural gamma radiation, electromagnetic conductivity, optical and acoustic televiewer, and heat-pulse flowmeter. The logs indicate several foliation and fracture trends in the bedrock. Two fracture-correlated lineaments trending 28? and 29?, identified with low-altitude aerial photography, are coincident with the dominant structural trend. The eight boreholes logged at Site 8 generally have few fractures and have yields ranging from 0 to 40 gallons per minute. The fractures that probably resulted in high well yields (20?40 gallons per minute) strike northeast-southwest or by the right hand rule, have an orientation of 215?, 47?, and 51?. Two-dimensional direct-current resistivity methods were used to collect detailed subsurface information about the overburden, bedrock-fracture zone depths, and apparent-dip directions. Analysis of data inversions from data collected with dipole-dipole and Schlumberger arrays indicated electrically conductive zones in the bedrock that are probably caused by fractured rock. These zones are coincident with extensions of fracture-correlated lineaments. The fracture-correlated lineaments and geophysical-survey results indicate a possible northeast-southwest anisotropy to the fractured rock.

Open-File Report↗

Potential application of radiogenic isotopes and geophysical methods to understand the hydrothermal dystem of the Upper Geyser Basin, Yellowstone National Park

Numerous geochemical and geophysical studies have been conducted at Yellowstone National Park to better understand the hydrogeologic processes supporting the thermal features of the Park. This report provides the first 87Sr/86Sr and 234U/238U data for thermal water from the Upper Geyser Basin (UGB) intended to evaluate whether heavy radiogenic isotopes might provide insight to sources of groundwater supply and how they interact over time and space. In addition, this report summarizes previous geophysical studies made at Yellowstone National Park and provides suggestions for applying non-invasive ground and airborne studies to better understand groundwater flow in the subsurface of the UGB. Multiple samples from Old Faithful, Aurum, Grand, Oblong, and Daisy geysers characterized previously for major-ion concentrations and isotopes of water (δ2H, δ18O, and 3H) were analyzed for Sr and U isotopes. Concentrations of dissolved Sr and U are low (4.3–128 ng g-1 Sr and 0.026–0.0008 ng g-1 U); consequently only 87Sr/86Sr data are reported for most samples. Values of 87Sr/86Sr for most geysers remained uniform between April and September 2007, but show large increases in all five geysers between late October 2007 and early April, 2008. By late summer of 2008, 87Sr/86Sr values returned to values similar to those observed a year earlier. Similar patterns are not present in major-ion data measured on the same samples. Furthermore, large geochemical differences documented between geysers are not observed in 87Sr/86Sr data, although smaller differences between sites may be present. Sr-isotope data are consistent with a stratified hydrologic system where water erupted in spring and summer of 2007 and summer of 2008 equilibrated with local intracaldera rhyolite flows at shallower depths. Water erupted between October 2007 and April 2008 includes greater amounts of groundwater that circulated deep enough to acquire a radiogenic 87Sr/86Sr, most likely from Archean basement rocks. Details of how the shallow and deep components interact and mechanisms causing these interactions remain unknown, but the data demonstrate the usefulness of obtaining Sr-isotope data from future sample campaigns. Geophysical methods that would be useful for characterization of the UGB subsurface properties and geothermal system include electromagnetic (EM), gravity, and ambient seismic. A suite of ground-based EM methods could be used in a synergistic combination together with airborne EM surveys to provide data for a range of spatial scales and resolutions. Existing thermal data for the shallow subsurface could be used to relate ground and airborne EM survey data to locations of geothermal fluids near the surface. Gravity surveys would be useful for mapping subsurface density anomalies and possibly monitoring changes in degree of saturation with groundwater. Ambient seismic surveys would be useful for estimating the thickness of unconsolidated deposits that contain the shallow groundwater system. A study that combines radiogenic isotope tracers with geophysical methods has the potential to better characterize the geothermal workings in the UGB. Insights gained could lead to a better understanding of the geothermal system and how Park infrastructure may cause perturbations. Measurements of radiogenic isotopes from multiple geysers and pools in localized areas within the UGB that are coupled with data from geophysical surveys would help refine conceptual models of mixing between deep- and shallow-derived subsurface fluids.

Wyoming↗

Geophysical assessment of a proposed landfill site in Fredericktown, Missouri

In June 2018, U.S. Geological Survey in cooperation with the U.S. Environmental Protection Agency (EPA) collected geophysical measurements to help evaluate the suitability of a proposed landfill site for disposing mine-waste materials in Fredericktown, MO. The geophysical investigation included electromagnetic induction, electrical resistivity tomography, horizontal-to-vertical spectral ratio passive seismic, and shear-wave refraction to characterize the unconsolidated sediment or regolith above the bedrock and the depth to crystalline bedrock. Water-based electromagnetic surveys and forward looking infrared imagery were used along the lake shoreline to identify potential groundwater-surface water interactions. Nested piezometers were installed at two locations along the shoreline to further characterize and validate the groundwater-surface water interactions identified with geophysical methods. Collectively, geophysical surveys were used to evaluate the overall suitability of the proposed site for use as a mine waste-soil and sediment repository and to evaluate this suite of geophysical methods for rapid collection and assessment of very shallow sediments.

Missouri↗

Lithostratigraphic, geophysical, and hydrogeologic observations from a boring drilled to bedrock in glacial sediments near Nantucket Sound in East Falmouth, Massachusetts

In spring 2016, a 310-foot-deep boring (named MA–FSW 750) was drilled by the U.S. Geological Survey near Nantucket Sound in East Falmouth, Massachusetts, to investigate the hydrogeology of the southern coast of western Cape Cod. Few borings that are drilled to bedrock exist in the area, and the study area was selected to fill a gap between comprehensive geologic datasets inland to the north and marine geophysical data from beneath Nantucket Sound to the south. A permanent monitoring well (MA–FSW 750–0100) was installed in the boring upon the completion of the drilling and core collection. Observations from sediment cores and surface and borehole geophysical measurements were used to delineate three zones relevant to understanding groundwater flow at the study location. Shallow sands and gravels (0–107 feet [ft] below land surface [bls]) underlain by silt-rich fine and very fine sand (107–175 ft bls) form a zone of high permeability underlain by a zone of relatively lower permeability, referred to as the “shallow high-permeability” and “low-permeability” zones, respectively. A sharp lithological contact separating the shallow high-permeability and low-permeability zones may affect vertical flow of groundwater. Fine to coarse sand with intervals of clay and silt from 175 to 300 ft bls represent a deep zone of relatively high permeability, referred to as the “deep high-permeability” zone. A compacted, nonsorted unit (identified as basal till) and the bedrock surface were encountered at 300 and 305 ft bls, respectively. Hydraulic conductivity estimates from nuclear magnetic resonance logs and sediment grain-size distribution analyses indicated that the shallow high-permeability zone contributes substantially to the capacity of the aquifer to transmit groundwater at the study location. Results from geophysical surveys indicate a gradual transition from fresh to saline groundwater in the interval from 105 to 160 ft bls. Freshwater at the study site is present in the saturated unconsolidated sediments only in the 75 ft between 30 ft (the water table) and 105 ft bls in the shallow high-permeability zone. Sediments shallower than 175 ft bls closely resemble the downward fining post-Wisconsinan age deltaic and lacustrine deposits present in many parts of western Cape Cod; sediments deeper than 175 ft appear to be the product of earlier depositional processes more local to the southern coast of western Cape Cod. This study highlights how high-resolution observations of cored material coupled with a multitool geophysical approach can characterize a single boring to help better understand regional glacial history and hydrogeology.

Massachusetts↗

Geophysical and video logs of selected wells at and near the former Naval Air Warfare Center Warminster, Bucks County, Pennsylvania, 2017-19

The U.S. Geological Survey (USGS) collected borehole geophysical and video logs in 17 open-hole wells in Northampton, Warminster, and Warwick Townships, Bucks County, Pennsylvania during 2017–19 to support detailed groundwater investigations at and near the former Naval Air Warfare Center (NAWC) Warminster, where groundwater contamination with per- and polyfluoroalkyl substances (PFAS) had become a concern since 2014. The area is underlain by the Triassic Stockton Formation, which forms a fractured-sedimentary-rock aquifer used for private, industrial, and public drinking-water supply. The geophysical and video logs were used to characterize the boreholes and identify potential water-bearing fractures for subsequent detailed investigations. Of the 17 wells that were logged, subsequent investigations were conducted by USGS in 15 wells and included hydraulic tests of discrete water-bearing zones using a straddle-packer system in 13 wells and depth-discrete point sampling in 2 wells. These 15 wells ranged in depth from about 210 to 604 feet (ft) below land surface (bls) and included six new 6-inch diameter wells drilled to initial depths of 600 ft bls on the former NAWC Warminster base property in 2018 and nine 8- to 12-inch diameter existing former production or unused test wells. Partial geophysical or video logs also were collected by USGS during 2018 in two other wells that were not included in subsequent detailed investigations. Most wells had numerous water-bearing fractures or openings throughout the depth of the open boreholes. Most of these water-bearing features appeared to be openings parallel to bedding or high-angle fractures approximately orthogonal to bedding. Casing lengths ranged from about 19 to 93 ft bls. Depth to the ambient water level at the time of logging ranged from about 1.8 ft above land surface in a flowing well to about 55 ft bls. Measured borehole flow was predominantly downward in most of the deepest wells (greater than 400 ft), which were commonly located at the highest land-surface elevations, and contained inflow from fractures at relatively shallow depths and outflow through fractures near or below depths of 500 ft bls. Borehole flow was predominantly upward in most wells less than 400 ft in depth.

Pennsylvania↗

Hydrogeophysical investigations at Hidden Dam, Raymond, California

Self-potential and direct current resistivity surveys are carried out at the Hidden Dam site in Raymond, California to assess present-day seepage patterns and better understand the hydrogeologic mechanisms that likely influence seepage. Numerical modeling is utilized in conjunction with the geophysical measurements to predict variably-saturated flow through typical two-dimensional dam cross-sections as a function of reservoir elevation. Several different flow scenarios are investigated based on the known hydrogeology, as well as information about typical subsurface structures gained from the resistivity survey. The flow models are also used to simulate the bulk electrical resistivity in the subsurface under varying saturation conditions, as well as the self-potential response using petrophysical relationships and electrokinetic coupling equations. The self-potential survey consists of 512 measurements on the downstream area of the dam, and corroborates known seepage areas on the northwest side of the dam. Two direct-current resistivity profiles, each approximately 2,500 ft (762 m) long, indicate a broad sediment channel under the northwest side of the dam, which may be a significant seepage pathway through the foundation. A focusing of seepage in low-topography areas downstream of the dam is confirmed from the numerical flow simulations, which is also consistent with past observations. Little evidence of seepage is identified from the self-potential data on the southeast side of the dam, also consistent with historical records, though one possible area of focused seepage is identified near the outlet works. Integration of the geophysical surveys, numerical modeling, and observation well data provides a framework for better understanding seepage at the site through a combined hydrogeophysical approach.

California↗

Scenario Evaluator for Electrical Resistivity survey pre-modeling tool

Geophysical tools have much to offer users in environmental, water resource, and geotechnical fields; however, techniques such as electrical resistivity imaging (ERI) are often oversold and/or overinterpreted due to a lack of understanding of the limitations of the techniques, such as the appropriate depth intervals or resolution of the methods. The relationship between ERI data and resistivity is nonlinear; therefore, these limitations depend on site conditions and survey design and are best assessed through forward and inverse modeling exercises prior to field investigations. In this approach, proposed field surveys are first numerically simulated given the expected electrical properties of the site, and the resulting hypothetical data are then analyzed using inverse models. Performing ERI forward/inverse modeling, however, requires substantial expertise and can take many hours to implement. We present a new spreadsheet-based tool, the Scenario Evaluator for Electrical Resistivity (SEER), which features a graphical user interface that allows users to manipulate a resistivity model and instantly view how that model would likely be interpreted by an ERI survey. The SEER tool is intended for use by those who wish to determine the value of including ERI to achieve project goals, and is designed to have broad utility in industry, teaching, and research.

Groundwater↗

Geophysical bed sediment characterization of the Androscoggin River from the former Chlor-Alkali Facility Superfund Site, Berlin, New Hampshire, to the state border with Maine, August 2009

The former Chlor-Alkali Facility in Berlin, New Hampshire, was listed on the U.S. Environmental Protection Agency National Priorities List in 2005 as a Superfund site. The Chlor-Alkali Facility lies on the east bank of the Androscoggin River. Elemental mercury currently discharges from that bank into the Androscoggin River. The nature, extent, and the speciation of mercury and the production of methyl mercury contamination in the adjacent Androscoggin River is the subject of continuing investigations. The U.S. Geological Survey, in cooperation with Region I of the U.S. Environmental Protection Agency, used geophysical methods to determine the distribution, thickness, and physical properties of sediments in the Androscoggin River channel at a small area of an upstream reference reach and downstream from the site to the New Hampshire–Maine State border. Separate reaches of the Androscoggin River in the study area were surveyed with surface geophysical methods including ground-penetrating radar and step-frequency electromagnetics. Results were processed to assess sediment characteristics including grain size, electrical conductivity, and pore-water specific conductance. Specific conductance measured during surface- and pore-water sampling was used to help interpret the results of the geophysical surveys. The electrical resistivity of sediment samples was measured in the laboratory with intact pore water for comparison with survey results. In some instances, anthropogenic features and land uses, such as roads and power lines affected the detection of riverbed properties using geophysical methods; when this occurred, the data were removed. Through combining results, detailed riverbed sediment characterizations were made. Results from ground-penetrating radar surveys were used to image and measure the depth to the riverbed, depth to buried riverbeds, riverbed thickness and to interpret material-type variations in terms of relative grain size. Fifty two percent of the riverbed in the study area was covered with gravel and finer sediments. The electrically resistive river water and sediment in this study area were conducive to the penetration of the ground-penetrating radar and step-frequency electromagnetic signals and allowed for effective sediment characterization by geophysical methods. The reach between the former Chlor-Alkali Facility and the Riverside Dam, had small areas of fine sediment (estimated 11 percent of riverbed area), found on the upstream left bank and the downstream right bank, with an electromagnetic conductivity (31.4 millisiemens per meter (mS/m) maximum) that was higher than the upstream reference reach. The greatest electromagnetic conductivity (195 mS/m), pore-water specific conductance (324 mS/m) and lab measured sediment conductivity of (76.8 mS/m, measured with a direct-current resistivity test box) in the study were measured approximately 1 mile (mi) downstream of the site from a sandbar on the left bank. Reaches adjacent to and within 2 mi downstream from the site had elevated electromagnetic conductivity despite having lower estimated percentages of riverbed area covered in sediment (11, 25, and 61 percent, respectively) than the reference reach (97). Typically finer grained sediment with similar mineralogy will be more conductive. The Shelburne Reservoir is approximately 8 mi downstream from the site had the second greatest pore-water specific conductance measured, 45.8 mS/m. Many of the locations with the largest step-frequency electromagnetic values have not been sampled for pore water and sediment.

New Hampshire↗

Ground geophysical study of the Buckeye mine tailings, Boulder watershed, Montana

The Buckeye mine site is located in the Boulder River watershed along Basin Creek, in northern Jefferson County, Montana. This project is part of the Boulder River watershed Abandoned Mine Lands Initiative, and is a collaborative effort between the U.S. Geological Survey and Bureau of Land Management in the U.S. Department of the Interior, and the U.S. Forest Service in the U.S. Department of Agriculture. The site includes a large flotation milltailing deposit, which extends to the stream and meadows below the mine. These tailings contain elevated levels of metals, such as silver, cadmium, copper, lead, and zinc. Metal-rich fluvial tailings containing these metals, are possible sources of ground and surface water contamination. Geophysical methods were used to characterize the sediments at the Buckeye mine site. Ground geophysical surveys, including electromagnetics, DC resistivity, and total field magnetic methods, were used to delineate anomalies that probably correlate with subsurface metal contamination. Subsurface conductivity was mapped using EM-31 and EM-34 terrain conductivity measuring systems. The conductivity maps represent variation of concentration of dissolved solids in the subsurface from a few meters, to an approximate depth of 30 meters. Conductive sulfides several centimeters thick were encountered in a shallow trench, dug in an area of very high conductivity, at a depth of approximately 1 to1.5 meters. Laboratory measurements of samples of the sulfide layers show the conductivity is on the order of 1000 millisiemens. DC resistivity soundings were used to quantify subsurface conductivity variations and to estimate the depth to bedrock. Total field magnetic measurements were used to identify magnetic metals in the subsurface. The EM surveys identified several areas of relatively high conductivity and detected a conductive plume extending to the southwest, toward the stream. This plume correlates well with the potentiometric surface and direction of ground water flow, and with water quality data from monitoring wells in and around the tailings. The electrical geophysical data suggests there has been vertical migration of high dissolved solids. A DC sounding made on a nearby granite outcrop to the north of the mine showed that the shallow conductivity is on the order of 5 millisiemens/m. Granite underlying the mine tailings, with similar electrical properties as the outcropping area, may be more than 30 meters deep.

Montana↗

Borehole-geophysical investigation of the University of Connecticut landfill, Storrs, Connecticut

A borehole-geophysical investigation was conducted to help characterize the hydrogeology of the fractured-rock aquifer and the distribution of unconsolidated glacial deposits near the former landfill and chemical waste-disposal pits at the University of Connecticut in Storrs, Connecticut. Eight bedrock boreholes near the landfill and three abandoned domestic wells located nearby were logged using conventional and advanced borehole-geophysical methods from June to October 1999. The conventional geophysical-logging methods included caliper, gamma, fluid temperature, fluid resistivity, and electromagnetic induction. The advanced methods included deviation, optical and acoustic imaging of the borehole wall, heat-pulse flowmeter, and directional radar reflection. Twenty-one shallow piezometers (less than 50-feet deep) were logged with gamma and electromagnetic induction tools to delineate unconsolidated glacial deposits. Five additional shallow bedrock wells were logged with conventional video camera, caliper, electromagnetic induction, and fluid resistivity and temperature tools. The rock type, foliation, and fracturing of the site were characterized from high-resolution optical-televiewer (OTV) images of rocks penetrated by the boreholes. The rocks are interpreted as fine- to medium-grained quartz-feldsparbiotite-garnet gneiss and schist with local intrusions of quartz diorite and pegmatite and minor concentrations of sulfide mineralization similar to rocks described as the Bigelow Brook Formation on regional geologic maps. Layers containing high concentrations of sulfide minerals appear as high electrical conductivity zones on electromagneticinduction and borehole-radar logs. Foliation in the rocks generally strikes to the northeast-southwest and dips to the west, consistent with local outcrop observations. The orientation of foliation and small-scale gneissic layering in the rocks, however, varies locally and with depth in some of the boreholes. In two of the boreholes, the foliation strikes predominantly to the northwest and dips to the northeast. Although small-scale faults and lithologic discontinuities were observed in the OTV data, no large-scale faults were observed that appear on regional geologic maps. Fractures were located and characterized through the use of conventional geophysical, OTV, acoustic-televiewer (ATV), and borehole-radar logs. The orientation of fractures varies considerably across the site; some fractures are parallel to the foliation, whereas others cross-cut the foliation. Many of the transmissive fractures in the bedrock boreholes strike about N170°E and N320°E with dips of less than 45°. Other transmissive fractures strike about N60°E with dips of more than 60°. Most of the transmissive fractures in the domestic wells strike about N60°E and N22°E with dips of more than 45°. The strike of N60°E is parallel to the trend of a thrust fault that appears on regional geologic maps. Vertical flow in the boreholes was measured with the heat-pulse flowmeter under ambient and (or) pumping conditions. Results of ATV, OTV, and conventional logs were used to locate specific zones for flowmeter testing. Ambient downflow was measured in three boreholes, ambient upflow was measured in two other boreholes, and both ambient downflow and upflow were measured in a sixth borehole. The other five bedrock boreholes and domestic wells did not have measurable vertical flow. The highest rate of ambient flow was measured in the background borehole in which upflow and downflow converged and exited the borehole at a fracture zone near a depth of 62 feet. Ambient flow of about 340 gallons per day was measured. In the other five wells, ambient flow of about 20 to 35 gallons per day was measured. Under low-rate pumping (0.25 to 1 gallon per minute), one to six inflow zones were identified in each well. Usually the fractures that are active under ambient conditions contribute to the well under pumping conditions. To prevent ambient vertical flow and the potential for cross-contamination, temporary borehole liners were installed in five of the boreholes. Specific-capacity and open-hole transmissivity values were determined in eight boreholes completed in bedrock. The specific capacity estimated for these boreholes ranges from 0.14 to 1.6 gallons per minute per foot. The values for open-hole transmissivity range over two orders of magnitude and when proportioned to individual fracture transmissivity, range from 23 to 340 feet squared per day. Two boreholes had been drilled to intersect electrically conductive zones identified by previous surface-geophysical investigations. The borehole-geophysical results indicate that the boreholes penetrate electrically conductive structures consistent with the anomalies interpreted from the surface-geophysical data. Borehole MW121R was located to intersect a dipping electrically conductive anomaly at about 60 feet, interpreted from the two-dimensional direct currentresistivity survey conducted on the western side of the landfill. The electromagnetic-conductivity log in the borehole contains a high electrical conductivity anomaly at a depth of 69 feet. The magnitude of this anomaly is nearly 10,000 millisiemens per meter and is coincident with a layer containing sulfide mineralization, rather than fractures. The other borehole, MW105R, was located to intersect another anomaly south of the landfill. This anomaly was interpreted as a north-south striking, westward dipping feature. In the borehole, two south-striking, westward dipping fractures were identified in the ATV, OTV, and radar logs. The specific conductance of the fluid measured near these fractures was as high as 1,250 microsiemens per centimeter. Water-quality samples collected in October 1999 from an isolated zone from 71.5 to 76.5 feet indicated high specific conductance (810 microsiemens per centimeter), high concentrations of iron and cadmium, negative oxidation-reduction potential, and chlorobenzene. Collectively, these parameters indicate that the high specific conductance in the borehole logs for MW105R was caused by landfill leachate. Therefore, the anomaly identified by boreholeand surface-geophysical surveys is interpreted as a conductive lithologic feature and a permeable fracture zone that contains landfill leachate.

Connecticut↗

Archive of chirp seismic reflection data collected during USGS cruises 01SCC01 and 01SCC02, Timbalier Bay and offshore East Timbalier Island, Louisiana, June 30 - July 9 and August 1 - 12, 2001

In June, July, and August of 2001, the U.S. Geological Survey (USGS), in cooperation with the University of New Orleans, the U.S. Army Corps of Engineers, and the Louisiana Department of Natural Resources, conducted a shallow geophysical and sediment core survey of Timbalier Bay and the Gulf of Mexico offshore East Timbalier Island, Louisiana. This report serves as an archive of unprocessed digital seismic reflection data, trackline navigation files, trackline navigation maps, observers' logbooks, Geographic Information Systems (GIS) information, and formal Federal Geographic Data Committee (FGDC) metadata. In addition, a gained digital Graphics Interchange Format (GIF) image of each seismic profile is provided. Please see Kulp and others (2002), Flocks and others (2003), and Kulp and others (in prep.) for further information about the sediment cores collected and the geophysical results. For convenience, a list of acronyms and abbreviations frequently used in this report is also included. This Digital Versatile Disc (DVD) document is readable on any computing platform that has standard DVD driver software installed. Documentation on this DVD was produced using Hyper Text Markup Language (HTML) utilized by the World Wide Web (WWW) and allows the user to access the information using a web browser (i.e. Netscape, Internet Explorer). To access the information contained on these discs, open the file 'index.htm' located at the top level of each disc using a web browser. This report also contains WWW links to USGS collaborators and other agencies. These links are only accessible if access to the internet is available while viewing these DVDs. The archived chirp seismic reflection data are in standard Society of Exploration Geophysicists (SEG) SEG-Y format (Barry et al., 1975) and may be downloaded for processing with public domain software such as Seismic Unix (SU), currently located at http://www.cwp.mines.edu/cwpcodes/index.html. Examples of SU processing scripts are provided in the CHIRP.tar file located in the SU subfolder of the SOFTWARE folder located at the top level of each disc. In-house (USGS) DOS and Microsoft Windows compatible software for viewing SEG-Y headers - DUMPSEGY.EXE (Zihlman, 1992) - is provided in the USGS subfolder of the SOFTWARE folder. Processed profile images, trackline navigation maps, logbooks, and formal metadata may be viewed with a web browser.

Louisiana↗

Detection and mapping of fractures and cavities using borehole radar

Borehole radar can be used in a single-hole reflection mode or in a cross-hole tomography mode. In the reflection mode, radar provides an image of discontinuities in the bedrock surrounding a borehole, including bedding planes, lithologic contacts, fractures, and cavities. The measurements are either directional or omni-directional, depending upon the type of equipment and antennas. In the tomography mode, where the transmitter and receiver are in separate boreholes, radar provides an image of the planar section between the boreholes. The radius of investigation depends on the antenna frequency and the electrical conductivity of the bedrock. For a central frequency of 100 megahertz, in the reflection mode the ranges are typically 10 to 40 meters in resistive solid rock and less than 5 meters in conductive, clay-rich, or silty rock. Single-hole and cross-hole radar also have been used for water-supply investigations in the northeast-ern United States. Borehole radar was used to investigate crystalline bedrock in two rapidly developing com-munities that rely on water resources in the bedrock. The surveys were conducted and interpreted along with data from other borehole geophysical tools. The borehole radar surveys were used to identify the location and orientation of reflectors, locate the primary pathways of flow to the supply wells, and identify aquifer character-istics that may be useful in siting a production well and protecting high-yielding wells in crystalline rocks. Borehole radar has been used to investigate fractures, cavities, and lithologic changes at several sites in Europe. The radar data has been interpreted in conjuction with the results of modeling of borehole-radar re-sponse. At the Grimsel nuclear waste laboratory in Switzerland, single-hole reflection and tomography methods were used to characterize the rock in inclined boreholes. At numerous geotechnical sites in Belgium, France, and the Netherlands, borehole radar has been used to characterize the rock and identify fractures and cavities.

Conference Paper↗

Archive of boomer seismic reflection data collected during USGS cruises 01SCC01 and 01SCC02, Timbalier Bay and offshore East Timbalier Island, Louisiana, June - August, 2001

In June, July, and August of 2001, the U.S. Geological Survey (USGS), in cooperation with the University of New Orleans (UNO), the U.S. Army Corps of Engineers, and the Louisiana Department of Natural Resources, conducted a shallow geophysical and sediment core survey of Timbalier Bay and the Gulf of Mexico offshore East Timbalier Island, Louisiana. This report serves as an archive of unprocessed digital seismic reflection data, trackline navigation files, trackline navigation maps, observers' logbooks, Geographic Information Systems (GIS) information, and formal Federal Geographic Data Committee (FGDC) metadata. In addition, a filtered and gained digital Graphics Interchange Format (GIF) image of each seismic profile is provided. Please see Kulp and others (2002), Flocks and others (2003), and Kulp and others (in prep.) for further information about the sediment cores collected and the geophysical results. For convenience, a list of acronyms and abbreviations frequently used in this report is also included. This Digital Versatile Disc (DVD) document is readable on any computing platform that has standard DVD driver software installed. Documentation on this DVD was produced using Hyper Text Markup Language (HTML) utilized by the World Wide Web (WWW) and allows the user to access the information using a web browser (i.e. Netscape, Internet Explorer). To access the information contained on this disc, open the file 'index.htm' located at the top level of the disc using a web browser. This report also contains WWW links to USGS collaborators and other agencies. These links are only accessible if access to the Internet is available while viewing this DVD. The archived boomer seismic reflection data are in standard Society of Exploration Geophysicists (SEG) SEG-Y format (Barry et al., 1975) and may be downloaded for processing with public domain software such as Seismic Unix (SU), currently located at http://www.cwp.mines.edu/cwpcodes/index.html. Examples of SU processing scripts are provided in the BOOM.tar file located in the SU subfolder of the SOFTWARE folder located at the top level of this disc. In-house (USGS) DOS and Microsoft Windows compatible software for viewing SEG-Y headers - DUMPSEGY.EXE (Zihlman, 1992) - is provided in the USGS subfolder of the SOFTWARE folder. Processed profile images, trackline navigation maps, logbooks, and formal metadata may be viewed with a web browser.

Louisiana↗

Hydrogeophysical investigations of earthen dams – Two California case studies

Excessive groundwater seepage can be a common engineering concern with earthen dams. The application of geophysical methods, whether for characterization or for long-term monitoring, to help inform mitigation strategies is becoming a more common addition to these investigations. The U.S. Geological Survey (USGS) has completed geophysical investigations at several earthen dams in cooperation with the U.S. Army Corps of Engineers (USACE) to help characterize subsurface hydrogeologic conditions and to identify potential sources of seepage. Summaries of the investigations of Martis Creek Dam and Hidden Dam, both located in California, are presented.

California↗

Characterizing infiltration through a mine-waste dump using electrical geophysical and tracer-injection methods, Clear Creek County, Colorado

Infiltration of surface water through mine waste can be an important or even dominant source of contaminants in a watershed. The Waldorf mine site in Clear Creek County, Colorado, is typical of tens of thousands of small mines and prospects on public lands throughout the United States. In this study, electromagnetic (EM) conductivity and direct current (dc) resistivity surveys were conducted in tandem with a NaCl tracer study to delineate ground-water flow paths through a mine-waste dump and adjacent wetland area. The tracer was used to tag adit water infiltrating from braided channels flowing over the top of the dump to seeps at the base of the dump. Infiltration from the braided channels had a maximum flow rate of 92 m/day and a hydraulic conductivity of 1.6 × 10 4 cm 3 /s. After rerouting of adit flow around the waste dump, discharge at some of the largest seeps was reduced, although not all seepage was eliminated entirely. Integrating results of the tracer study with those of the EM and dc geophysical surveys revealed two main flow paths of ground water, one beneath the dump and one through the dump. The main source of water to the first flow path is deeper ground water emerging from the fault zone beneath the collapsed adit. This flow path travels beneath the waste dump and appears to have been unaffected by rerouting of the adit discharge around the waste dump. The source of the second flow path is infiltration of adit water from braided channels flowing over the top of the dump, which is intermediate in depth and flows through the center of the waste dump. Following rerouting of adit flow, discharge to seeps at the toe of the dump along this flow path was reduced by as much as two-thirds, although not eliminated entirely. Improved understanding of ground-water flow paths through this abandoned mine site is important in developing effective remediation strategies to target sources of metals emanating from the adit, waste dump, and contaminated wetland area. Any use of trade, firm, or product names is for descriptive purposes only and does not imply endorsement by the U.S. government.

Colorado↗

Geophysical logs from a geologic test hole near Charleston, South Carolina

On March 2, 1975, the U.S. Geological Survey completed a series of geophysical well logs in the Charleston Project Deep Core Hole No. 1 located at Latitude 32° 53.2 'N and Longitude 80° 21 . 5'W in Dorchester County near Charleston, South Carolina. The land surface is at an elevation of 5.4 m (18 ft) above mean sea level. The total depth of the test hole is 793 m (2,600 ft) and the geophysical logs were recorded through fresh barite mud to the bottom. The deep geologic. test hole penetrated the entire section of Atlantic Coastal Plain sediments and extended about 40 m (130 ft) into basement rock composed of basalt flows. The purpose of the logging is to assist in the interpretation of the depositional environments, stratigraphy, structural, and geological history of the onshore and offshore areas surrounding Charleston, S.C. The purpose of this report is to make the uninterpretated geophysical recordings of the entire log suite publicly available . The logs available are shown in table 1, along with the operating depth intervals, total footage, scale, units of measure, combination log, and other pertinent data.

South Carolina↗

Samples from the United States eastern continental margin collected by the U.S. Geological Survey

As part of the National Geophysical and Solar-Terrestrial Data Center's (NGSDC's) project to maintain a computer-accessed list of marine geological samples, the U.S. Geological Survey has inventoried 3,949 samples from the continental margin of the Eastern United States (Fig. 1). Most (3,868) of these samples are grab and dredge samples collected by the U.S. Geological Survey in an earlier cooperative program with the Woods Hole Oceanographic Institution (WHOI) and are stored at WHOI. Samples collected since 1974 are stored by the U.S. Geological Survey. This more recent collection is made up of 3,815.5 m of rotary-drilled cores collected at 19 stations in 1976 by the drill ship GLOMAR CONCEPTION, 243.8 m of piston cores and 38.3 m of gravity cores collected during the 1979 and 1980 cruises of the R/V ENDEAVOR, and &grab samples collected by the M/V STATE ARROW in 1978.

United States eastern continental margin↗