Geology Reports⌕ Search

SEARCH · Geology Reports

Results for “Water-Resources Report”

Search indexed USGS publications on groundwater, aquifers, geologic maps, mineral resources and earthquakes. Explore source records by subject and place.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41Linked to original sources

One-dimensional simulation of stratification and dissolved oxygen in McCook Reservoir, Illinois

As part of the Chicagoland Underflow Plan/Tunnel and Reservoir Plan, the U.S. Army Corps of Engineers, Chicago District, plans to build McCook Reservoir.a flood-control reservoir to store combined stormwater and raw sewage (combined sewage). To prevent the combined sewage in the reservoir from becoming anoxic and producing hydrogen sulfide gas, a coarse-bubble aeration system will be designed and installed on the basis of results from CUP 0-D, a zero-dimensional model, and MAC3D, a three-dimensional model. Two inherent assumptions in the application of MAC3D are that density stratification in the simulated water body is minimal or not present and that surface heat transfers are unimportant and, therefore, may be neglected. To test these assumptions, the previously tested, one-dimensional Dynamic Lake Model (DLM) was used to simulate changes in temperature and dissolved oxygen in the reservoir after a 1-in-100-year event. Results from model simulations indicate that the assumptions made in MAC3D application are valid as long as the aeration system, with an air-flow rate of 1.2 cubic meters per second or more, is operated while the combined sewage is stored in the reservoir. Results also indicate that the high biochemical oxygen demand of the combined sewage will quickly consume the dissolved oxygen stored in the reservoir and the dissolved oxygen transferred through the surface of the reservoir; therefore, oxygen must be supplied by either the rising bubbles of the aeration system (a process not incorporated in DLM) or some other technique to prevent anoxia.

Illlinois↗

Ground-water quality in Quaternary deposits of the central High Plains aquifer, south-central Kansas, 1999

Water samples from 20 randomly selected domestic water-supply wells completed in the Quaternary deposits of south-central Kansas were collected as part of the High Plains Regional Ground-Water Study conducted by the U.S. Geological Survey's National Water-Quality Assessment Program. The samples were analyzed for about 170 water-quality constituents that included physical properties, dissolved solids and major ions, nutrients and dissolved organic carbon, trace elements, pesticides, volatile organic compounds, and radon. The purpose of this study was to provide a broad overview of ground-water quality in a major geologic subunit of the High Plains aquifer. Water from five wells (25 percent) exceeded the 500-milligrams-per-liter of dissolved solids Secondary Maximum Contaminant Level for drinking water. The Secondary Maximum Contaminant Levels of 250 milligrams per liter for chloride and sulfate were exceeded in water from one well each. The source of these dissolved solids was probably natural processes. Concentrations of most nutrients in water from the sampled wells were small, with the exception of nitrate. Water from 15 percent of the sampled wells had concentrations of nitrate greater than the 10-milligram-per-liter Maximum Contaminant Level for drinking water. Water from 80 percent of the sampled wells showed nitrate enrichment (concentrations greater than 2.0 milligrams per liter), which is more than what might be expected for natural background concentrations. This enrichment may be the result of synthetic fertilizer applications, the addition of soil amendment (manure) on cropland, or livestock production. Most trace elements in water from the sampled wells were detected only in small concentrations, and few exceeded respective water-quality standards. Only arsenic was detected in one well sample at a concentration (240 micrograms per liter) that exceeded its proposed Maximum Contaminant Level (5.0 micrograms per liter). Additionally, one concentration of iron and two concentrations of manganese were larger than the Secondary Maximum Contaminant Levels of 300 and 50 micrograms per liter, respectively. Some occurrences of trace elements may have originated from human-related sources; however, the generally small concentrations that were measured probably reflect mostly natural sources for these constituents. A total of 47 pesticide compounds from several classes of herbicides and insecticides that included triazine, organophosphorus, organochlorine, and carbamate compounds and three pesticide degradation products were analyzed in ground-water samples during this study. Water from 50 percent of the wells sampled had detectable concentrations of one or more of these 47 compounds. The herbicide atrazine and its degradation product deethylatrazine were detected most frequently (in water from eight and nine wells, respectively); other pesticides detected were the insecticides carbofuran (in water from one well) and diazinon (in water from one well), and the herbicide metolachlor (in water from two wells). However, all concentrations of these compounds were small and substantially less than established Maximum Contaminant Levels. The use of pesticides in crop production probably is largely responsible for the occurrence of pesticides in the ground-water samples collected during this study. Although concentrations of detected pesticides were small (relative to established Maximum Contaminant Levels), the synergistic effect of these concentrations and long-term exposure to multiple pesticides on human health are unknown. Water samples from the Quaternary deposits were analyzed for 85 volatile organic compounds. Water from two wells (10 percent) had a detectable concentration of a volatile organic compound. Chloroform was detected at concen-trations of 0.18 and 0.25 microgram per liter, substantially less than the 100-microgram-per-liter Maximum Contaminant Level for total trihalomethanes. In general, the occurrence and detectio

Water-Resources Investigations Report↗

Quantification of metal loads by tracer injection and synoptic sampling in Daisy Creek and the Stillwater River, Park County, Montana, August 1999

A metal-loading study using tracer-injection and synoptic-sampling methods was conducted in Daisy Creek and a short reach of the Stillwater River during baseflow in August 1999 to quantify the metal inputs from acid rock drainage in the New World Mining District near Yellowstone National Park and to examine the downstream transport of these metals into the Stillwater River. Loads were calculated for many mainstem and inflow sites by combining streamflow determined using the tracer-injection method with concentrations of major ions and metals that were determined in synoptic water-quality samples. Water quality and aquatic habitat in Daisy Creek have been affected adversely by drainage derived from waste rock and adit discharge at the McLaren Mine as well as from natural weathering of pyrite-rich mineralized rock that comprises and surrounds the ore zones. However, the specific sources and transport pathways are not well understood. Knowledge of the main sources and transport pathways of metals and acid can aid resource managers in planning and conducting effective and cost-efficient remediation activities. The metals cadmium, copper, lead, and zinc occur at concentrations that are sufficiently elevated to be potentially lethal to aquatic life in Daisy Creek and to pose a toxicity risk in part of the Stillwater River. Copper is of most concern in Daisy Creek because it occurs at higher concentrations than the other metals. Acidic surface inflows had dissolved concentrations as high as 20.6 micrograms per liter (μg/L) cadmium, 26,900 μg/L copper, 76.4 μ g/L lead, and 3,000 μ g/L zinc. These inflows resulted in maximum dissolved concentrations in Daisy Creek of 5.8 μ g/L cadmium, 5,790 μ g/L copper, 3.8 μ g/L lead, and 848 μ g/L zinc. Significant copper loading to Daisy Creek occurred only in the upper half of the stream. Sources included subsurface inflow and right-bank (mined side) surface inflows. Copper loads in left-bank (unmined side) surface inflows were negligible. Most (71 percent) of the total copper loading in the study reach occurred along a 341-foot reach near the stream’s headwaters. About 53 percent of the total copper load was contributed by five surface inflows that drain a manganese bog and the southern part of the McLaren Mine. Copper loading from subsurface inflow was substantial, contributing 46 percent of the total dissolved copper load to Daisy Creek. More than half of this subsurface copper loading occurred downstream from the reaches that received significant surface loading. Flow through the shallow subsurface appears to be the main copper-transport pathway from the McLaren Mine and surrounding altered and mineralized bedrock to Daisy Creek during base-flow conditions. Little is known about the source of acid and copper in this subsurface flow. However, possible sources include the mineralized rocks of Fisher Mountain upgradient of the McLaren Mine area, the surficial waste rock at the mine, and the underlying pyritic bedrock.

Montana↗

Summary of water-quality data, October 1987 through September 1997, for Fountain and Monument Creeks, El Paso and Pueblo Counties, Colorado

Fountain and Monument Creeks, which drain parts of El Paso and Pueblo Counties in Colorado, have been sampled systematically by the U.S. Geological Survey for many years to obtain records of water-quality properties and constituents; the data are stored in the National Water Inventory System. Statistical summaries of these data indicate that they have spatial and temporal trends. Comparison of water-quality data to in-stream regulatory standards, some of which were calculated in this report, indicate that some exceedances are widespread in the system and that some occur locally. Nonparametric tests to quantitatively detect monotonic trends in water-quality data indicate that many water-quality properties and constituents do not have significant monotonic trends; detected trends were mostly downward.

Water-Resources Investigations Report↗

Aquifer test to determine hydraulic properties of the Elm aquifer near Aberdeen, South Dakota

The Elm aquifer, which consists of sandy and gravelly glacial-outwash deposits, is present in several counties in northeastern South Dakota. An aquifer test was conducted northeast of Aberdeen during the fall of 1999 to determine the hydraulic properties of the Elm aquifer in that area. An improved understanding of the properties of the aquifer will be useful in the possible development of the aquifer as a water resource. Historical water-level data indicate that the saturated thickness of the Elm aquifer can change considerably over time. From September 1977 through November 1985, water levels at three wells completed in the Elm aquifer near the aquifer test site varied by 5.1 ft, 9.50 ft, and 11.1 ft. From June 1982 through October 1999, water levels at five wells completed in the Elm aquifer near the aquifer test site varied by 8.7 ft, 11.4 ft, 13.2 ft, 13.8 ft, and 19.7 ft. The water levels during the fall of 1999 were among the highest on record, so the aquifer test was affected by portions of the aquifer being saturated that might not be saturated during drier times. The aquifer test was conducted using five existing wells that had been installed prior to this study. Well A, the pumped well, has an operating irrigation pump and is centrally located among the wells. Wells B, C, D, and E are about 70 ft, 1,390 ft, 2,200 ft, and 3,100 ft, respectively, in different directions from Well A. Using vented pressure transducers and programmable data loggers, water-level data were collected at the five wells prior to, during, and after the pumping, which started on November 19, 1999, and continued a little over 72 hours. Based on available drilling logs, the Elm aquifer near the test area was assumed to be unconfined. The Neuman (1974) method theoretical response curves that most closely match the observed water-level changes at Wells A and B were calculated using software (AQTESOLV for Windows Version 2.13-Professional) developed by Glenn M. Duffield of HydroSOLVE, Inc. These best fit theoretical response curves are based on a transmissivity of 24,000 ft 2 /d or a hydraulic conductivity of about 600 ft/d, a storage coefficient of 0.05, a specific yield of 0.42, and vertical hydraulic conductivity equal to horizontal hydraulic conductivity. The theoretical type curves match the observed data fairly closely at Wells A and B until about 2,500 minutes and 1,000 minutes, respectively, after pumping began. The increasing rate of drawdown after these breaks is an indication that a no-flow boundary (an area with much lower hydraulic conductivity) likely was encountered and that Wells A and B may be completed in a part of the Elm aquifer with limited hydraulic connection to the rest of the aquifer. Additional analysis indicates that if different assumptions regarding the screened interval for Well B and aquifer anisotropy are used, type curves can be calculated that fit the observed data using a lower specific yield that is within the commonly accepted range. When the screened interval for Well B was reduced to 5 ft near the top of the aquifer and horizontal hydraulic conductivity was set to 20 times vertical hydraulic conductivity, the type curves calculated using a specific yield of 0.1 and a transmissivity of 30,200 ft 2 /d also matched the observed data from Wells A and B fairly well. A version of the Theim equilibrium equation was used to calculate the theoretical drawdown in an idealized unconfined aquifer when a perfectly efficient well is being pumped at a constant rate. These calculations were performed for a range of pumping rates, drawdowns at the wells, and distances between wells that might be found in a production well field in the Elm aquifer. Although the aquifer test indicates that hydraulic conductivity near the well may be adequate to support a production well, the comparison of drawdown and recovery curves indicates the possibility that heterogeneities may limit the productive capacity of specific locations in the Elm aquifer during certain times. Additional test hole drilling and geophysical studies could help characterize these heterogeneities in the aquifer.

South Dakota↗

Simulation of projected water demand and ground-water levels in the Coffee Sand and Eutaw-McShan aquifers in Union County, Mississippi, 2010 through 2050

Ground water from the Eutaw-McShan and the Coffee Sand aquifers is the major source of supply for residential, commercial, and industrial purposes in Union County, Mississippi. Unbiased, scientifically sound data and assessments are needed to assist agencies in better understanding and managing available water resources as continuing development and growth places more stress on available resources. The U.S. Geological Survey, in cooperation with the Tennessee Valley Authority, conducted an investigation using water-demand and ground-water models to evaluate the effect of future water demand on groundwater levels. Data collected for the 12 public-supply facilities and the self-supplied commercial and industrial facilities in Union County were used to construct water-demand models. The estimates of water demand to year 2050 were then input to a ground-water model based on the U.S. Geological Survey finite-difference computer code, MODFLOW. Total ground-water withdrawals for Union County in 1998 were estimated as 2.85 million gallons per day (Mgal/d). Of that amount, municipal withdrawals were 2.55 Mgal/d with about 1.50 Mgal/d (59 percent) delivered to residential users. Nonmunicipal withdrawals were 0.296 Mgal/d. About 80 percent (2.27 Mgal/d) of the total ground-water withdrawal is produced from the Eutaw-McShan aquifer and about 13 percent (0.371 Mgal/d) from the Coffee Sand aquifer. Between normal- and high-growth conditions, total water demand could increase from 72 to 131 percent (2.9 Mgal/d in 1998 to 6.7 Mgal/d in year 2050) with municipal demand increasing from 77 to 146 percent (2.6 to 6.4 Mgal/d). Increased pumping to meet the demand for water was simulated to determine the effect on water levels in the Coffee Sand and Eutaw- McShan aquifers. Under baseline-growth conditions, increased water use by year 2050 could result in an additional 65 feet of drawdown in the New Albany area below year 2000 water levels in the Coffee Sand aquifer and about 120 feet of maximum drawdown in the Eutaw-McShan aquifer. Under normal-growth conditions, increased water use could result in an additional 65 feet of drawdown in the New Albany area below year 2000 water levels in the Coffee Sand aquifer and about 135 feet of maximum drawdown in the Eutaw-McShan aquifer. Under high-growth conditions, increased water use could result in 75 feet of drawdown in the New Albany area below year 2000 water levels in the Coffee Sand aquifer and about 190 feet of maximum drawdown in the Eutaw-McShan aquifer. The resulting highgrowth projected water level for the year 2050 at the center of the drawdown cone in the New Albany area is between 450 and 500 feet above the top of the Eutaw-McShan aquifer.

Mississippi↗

Surface-water and ground-water quality in the Yucaipa area, San Bernardino and Riverside Counties, California, 1996-98

The quality of surface water and ground water in the Yucaipa area was evaluated to determine general chemical characteristics and to identify areas of recent ground-water recharge. Water samples, collected from 8 sites on 3 creeks and from 25 wells, were analyzed for general chemistry, nutrients, tritium, and stable isotopes of hydrogen and oxygen. At one production well (1S/2W-25R4), water samples were collected at discrete depths during pumping and a continuous profile of the vertical flow rate inside the well casing was recorded. In addition to general-chemistry samples, tritium and carbon-14 samples were collected at this well to interpret the age of water at different depths.Results indicate that most water in the Yucaipa area is a calcium-bicarbonate type. The general chemical composition of surface water resembles that of ground water, although the concentration of most constituents is higher in ground water. The chemical composition of most ground-water samples is similar. Elevated concentrations of nitrate in some ground-water samples may indicate recharge from agricultural areas.In surface water that recharges ground water tritium activity ranged from 7 to 18 picocuries per liter. The range of tritium activity found in ground water indicates different times since recharge and possible mixing along ground-water flow paths. The oldest ground-water sample had a tritium activity less than 0.3 picocuries per liter, indicating more than 50 years since recharge. Water samples that had tritium activity greater than 0.3 picocuries per liter indicate that some of the water was recharged since 1952. The youngest ground water (greater than 7 picocuries per liter) was found near the hills and mountains surrounding the Yucaipa area; the oldest ground water (less than 0.3 picocuries per liter) was found in the Western Heights subbasin. Testing of the vertical contribution of ground water to well 1S/2W-25R4 showed that more than one-half of the water flowed into the well between depths of about 450 and 600 feet below land surface; the rest of the water flowed into the well between 600 and about 850 feet below land surface. At a discharge rate of 750 gallons per minute, virtually no water was contributed to the well below a depth of about 850 feet. The water samples collected at this well ranged in age from less than 50 to less than 400 years before present.

Water-Resources Investigations Report↗

Analysis of water levels in the Frenchman Flat area, Nevada Test Site

Analysis of water levels in 21 wells in the Frenchman Flat area, Nevada Test Site, provides information on the accuracy of hydraulic-head calculations, temporal water-level trends, and potential causes of water-level fluctuations. Accurate hydraulic heads are particularly important in Frenchman Flat where the hydraulic gradients are relatively flat (less than 1 foot per mile) in the alluvial aquifer. Temporal water-level trends with magnitudes near or exceeding the regional hydraulic gradient may have a substantial effect on ground-water flow directions. Water-level measurements can be adjusted for the effects of barometric pressure, formation water density (from water-temperature measurements), borehole deviation, and land-surface altitude in selected wells in the Frenchman Flat area. Water levels in one well were adjusted for the effect of density; this adjustment was significantly greater (about 17 feet) than the adjustment of water levels for barometric pressure, borehole deviation, or land-surface altitude (less than about 4 feet). Water-level measurements from five wells exhibited trends that were statistically and hydrologically significant. Statistically significant water-level trends were observed for three wells completed in the alluvial aquifer (WW-5a, UE-5n, and PW-3), for one well completed in the carbonate aquifer (SM-23), and for one well completed in the quartzite confining unit (Army-6a). Potential causes of water-level fluctuations in wells in the Frenchman Flat area include changes in atmospheric conditions (precipitation and barometric pressure), Earth tides, seismic activity, past underground nuclear testing, and nearby pumping. Periodic water-level measurements in some wells completed in the carbonate aquifer indicate cyclic-type water-level fluctuations that generally correlate with longer term changes (more than 5 years) in precipitation. Ground-water pumping fromthe alluvial aquifer at well WW-5c and pumping and discharge from well RNM-2s appear to cause water-level fluctuations in nearby observation wells. The remaining known sources of water-level fluctuations do not appear to substantially affect water-level changes (seismic activity and underground nuclear testing) or do not affect changes over a period of more than 1 year (barometric pressure and Earth tides) in wells in the Frenchman Flat area.

Water-Resources Investigations Report↗

Occurrence of selected radionuclides in ground water used for drinking water in the United States: A reconnaissance survey, 1998

The U.S. Geological Survey, in collaboration with the U.S. Environmental Protection Agency, the American Water Works Association, and the American Water Works Service Company, completed a targeted national reconnaissance survey of selected radionuclides in public ground-water supplies. Radionuclides analyzed included radium-224 (Ra-224), radium-226 (Ra-226), radium-228 (Ra-228), polonium-210 (Po-210) and lead-210 (Pb-210).This U.S. Geological Survey reconnaissance survey focused intentionally on areas with known or suspected elevated concentrations of radium in ground water to determine if Ra-224 was also present in the areas where other isotopes of radium had previously been detected and to determine the co-occurrence characteristics of the three radium isotopes (Ra-224, Ra-226, and Ra-228) in those areas. Ninety-nine raw-water samples (before water treatment) were collected once over a 6-month period in 1998 and 1999 from wells (94 of which are used for public drinking water) in 27 States and 8 physiographic provinces. Twenty-one of the 99 samples exceeded the current U.S. Environmental Protection Agency drinking-water maximum contaminant level of 5 picocuries per liter (pCi/L) for combined radium (Ra-226 + Ra-228). Concentrations of Ra-224 were reported to exceed 1 pCi/L in 30 percent of the samples collected, with a maximum concentration of 73.6 pCi/L measured in water from a nontransient, noncommunity, public-supply well in Maryland. Radium-224 concentrations generally were higher than those of the other isotopes of radium. About 5 percent of the samples contained concentrations of Ra-224 greater than 10 pCi/L, whereas only 2 percent exceeded 10 pCi/L for either Ra-226 or Ra-228. Concentrations of Ra-226 greater than 1 pCi/L were reported in 33 percent of the samples, with a maximum concentration of 16.9 pCi/L measured in water from a public-supply well in Iowa. Concentrations of Ra-228 greater than 1 pCi/L were reported in 22 samples, with a maximum concentration of 72.3 pCi/L measured in water from a non-transient, noncommunity, public-supply well in Maryland.Radium-224, which is a decay product of Ra-228 in the Th-232 decay series, was significantly correlated with Ra-228 (Spearman?s rank correlation coefficient ?r? equals 0.82) and to a lesser degree with Ra-226 (r equals 0.69), which is an isotope in the U-238 decay series. The rank correlation coefficient between Ra-226 and Ra-228 was 0.63. The high correlation between Ra-224 and Ra-228 concentrations and the corresponding isotopic ratios of the two (about 1:1 in 90 percent of the samples) indicates that the two radionuclides occur in approximately equal concentrations in most ground water sampled. Thus, Ra-228 can be considered as a reasonable proxy indicator for the occurrence of Ra-224 in ground water.The maximum concentration of Po-210 was 4.85 pCi/L and exceeded 1 pCi/L in only two samples. The maximum concentration of Pb-210 was 4.14 pCi/L, and about 10 percent of the samples exceeded 1 pCi/L. Areas with known, or suspected, elevated concentrations of polonium and lead were not targeted in this survey.Three major implications are drawn for future radionuclide monitoring on the basis of this information: (1) grossalpha particle analyses of ground water should be done within about 48-72 hours after collection to determine the presence of the short-lived, alpha-particle emitting isotopes, such as Ra-224, which was detected in elevated concentrations in many of the samples collected for this survey; (2) the isotope ratios of Ra-224 to Ra-228 in ground water are variable on a national scale, but the two radioisotopes generally occur in ratios near 1:1, therefore, the more commonly measured Ra-228 can be used as an indicator of Ra-224 occurrence for some general purposes other than compliance; and (3) the isotopic ratios of Ra-226 to Ra-228 were less than 3:2 in many samples. These ratios corroborate results of previous studies that have shown the presence of Ra-228.

Water-Resources Investigations Report↗

Simulated ground-water flow and water quality of the Mississippi River alluvium near Burlington, Iowa, 1999

The City of Burlington, Iowa, obtains some of its public water supply by withdrawing ground water from the Mississippi River alluvium, an alluvial aquifer adjacent to the Mississippi River. The U.S. Geological Survey, in cooperation with the City of Burlington, conducted a hydrologic study of the Mississippi River alluvium near Burlington in 1999 to improve understanding of the flow system, evaluate the effects of hypothetical pumping scenarios on the flow system, and evaluate selected water-quality constituents in parts of the alluvium. A steady-state, ground-water flow model was constructed for a 7-square-mile area of the alluvium using October 1999 hydrologic conditions to help conceptualize the flow system, identify sources of water to the alluvium, and assess potential effects from additional hypothetical ground-water withdrawals from the lower alluvium. The model was discretized into a 70-row by 68-column grid using cells measuring 200 feet by 200 feet. Three model layers were used to represent flow in the upper part of the alluvium, lower part of the alluvium, and bedrock. The primary sources of ground water to the alluvium were subsurface flow from areas of the alluvium adjacent to the modeled area, recharge from precipitation, subsurface flow from Flint River streamchannel deposits adjacent to the alluvium, and river leakage. The primary components of outflow from the flow system were river leakage, municipal ground-water withdrawals (pumpage), and leakage to drainage ditches. Three hypothetical pumping scenarios were used to assess the potential effects of increased ground-water withdrawals from the lower part of the alluvium: (1) pumping a second existing municipal well at a rate of 0.5 million gallons per day, (2) pumping a hypothetical well completed in an area between the city water-treatment facility and Flint River at a rate of 1.0 million gallons per day, and (3) pumping a hypothetical well completed in an area south of the Flint River at a rate of 1.0 million gallons per day. Maximum additional simulated drawdown in the upper alluvium ranged from less than 3 feet (for scenario 1) to about 9 feet (for scenario 3). Maximum additional simulated drawdown in the lower alluvium ranged from about 12 feet (for scenario 1) to about 34 feet (for scenario 3). Water budgets for each scenario indicated future additional withdrawals from the flow system near Burlington’s existing municipal wells would significantly increase the amount of river leakage into the flow system. Water samples collected from the alluvium indicated ground water can be classified as a calcium-magnesium-bicarbonate type. Reducing conditions likely occur in some localized areas of the alluvium, as suggested by relatively large concentrations of dissolved iron (4,390 micrograms per liter) and manganese (2, 430 micrograms per liter) in some ground-water samples. Nitrite plus nitrate was detected at concentrations greater than or equal to 8 milligrams per liter in three samples collected from observation wells completed in close proximity to cropland; the nitrite plus nitrate concentration in one groundwater sample exceeded the U.S. Environmental Protection Agency Maximum Contaminant Level for nitrate in drinking water (10 milligrams per liter as N). Triazine herbicides (atrazine, cyanazine, propazine, simazine, and selected degradation products) and chloroacetanilide herbicides (acetochlor, alachlor, and metolachlor) were detected in some water samples. A greater number of herbicide compounds were detected in surface-water samples than in ground-water samples. Herbicide concentrations typically were at least an order of magnitude greater in surfacewater samples than in ground-water samples. The Maximum Contaminant Level for alachlor (2 micrograms per liter) was exceeded in a sample from Dry Branch Creek at Tama Road and for atrazine (3 micrograms per liter) was exceeded in samples collected from Dry Branch Creek at Tama Road and the county drainage ditch at Tama Road.

Iowa↗

Simulated transport and biodegradation of chlorinated ethenes in a fractured dolomite aquifer near Niagara Falls, New York

Leakage of trichloroethene (TCE) from a neutralization pond at a former manufacturing facility near Niagara Falls, N.Y. during 1950-87 into the Guelph Formation of the Lockport Group, a fractured dolomite aquifer, created a plume of TCE and its metabolites that, by 1990, extended about 4,300 feet south of the facility. A smaller plume of dense, nonaqueous-phase liquids (DNAPL) probably serves as a continuing source of TCE. The presence of the TCE metabolites cis-1,2-dichloroethene (DCE), vinyl chloride (VC), and ethene in the plume, and the results of previous laboratory microcosm studies, indicate that the TCE is being degraded by naturally occurring microorganisms. Biodegradation rates of TCE and its metabolites were estimated through simulation with BIOMOC, a solute-transport model that represents multispecies reactions through Monod kinetics. A fracture zone in the Guelph Formation was represented as a porous medium containing an extensive, 3-foot thick layer with several interconnected fractures; this layer is bounded above and below by subhorizontal stratigraphic contacts. The Monod reaction constants were estimated through nonlinear regression to minimize the difference between computed concentrations of TCE and its metabolites, and the concentrations measured before and during 5 years of pump-and-treat remediation. Transport simulations indicated that, by April 1998, the chlorinated ethene plume had reached a dynamic equilibrium between the rate of TCE dissolution and the rate of removal through pumping and biodegradation. Biodegradation of chlorinated ethenes at the site can be simulated as first-order reactions because the concentrations are generally less than the half-saturation constants estimated for Monod kinetics (320 mg/L for TCE, 10 mg/L for DCE, and 1 mg/L for VC). Computed degradation rates are proportional to the estimated ground-water velocity, which could vary by more than an order magnitude at the site, as indicated by the estimated range of fracture porosity--3 to 0.3 percent. Half-lives corresponding to first-order rate constants estimated for the lower velocity (5 to 15 feet per day) ranged from 21 to 25 days for TCE, 170 to 230 days for DCE, and 18 to 23 days for VC. Chlorinated ethene concentrations of April 1998 were better reproduced when the TCE source was represented as a constant concentration than as a constant flux, because the latter predicted that the plume would dissipate after 5 years of pump-and-treat remediation. This result indicates that the rate of TCE dissolution is not limited by the mass of TCE in the DNAPL plume. Simulation of diffusion by the transport model MOC3D indicated that concentrations of these contaminants within the rock matrix surrounding the fracture zone were relatively unchanged after 5 years of pump-and-treat remediation. The principal sources of uncertainty in the prediction of biodegradation rates and of the fate of chlorinated ethenes at the site are the fracture porosity and DNAPL mass in the aquifer.

New York↗

Use of advanced borehole geophysical techniques to delineate fractured-rock ground-water flow and fractures along water-tunnel facilities in northern Queens County, New York

Advanced borehole geophysical methods were used to assess the geohydrology of crystalline bedrock along the course of a new water tunnel for New York City. The logging methods include natural gamma, spontaneous potential, single-point resistance, mechanical and acoustic caliper, focused electromagnetic induction, electromagnetic resistivity, magnetic susceptibility, borehole-fluid temperature and conductance, differential temperature, heat-pulse flowmeter, acoustic televiewer, borehole deviation, optical televiewer, and borehole radar. Integrated interpretation of the geophysical logs from an 825-foot borehole (1) provided information on the extent, orientation, and structure (foliation and fractures) within the entire borehole, including intensely fractured intervals from which core recovery may be poor; (2) delineated transmissive fracture zones intersected by the borehole and provided estimates of their transmissivity and hydraulic head; and (3) enabled mapping of the location and orientation of structures at distances as much as 100 ft from the borehole. Analyses of the borehole-wall image and the geophysical logs from the borehole on Crescent Street, in northern Queens County, are presented here to illustrate the application of the methods. The borehole penetrates gneiss and other crystalline bedrock that has predominantly southeastward dipping foliation and nearly horizontal and southeastward-dipping fractures. The heat-pulse flowmeter logs obtained under pumping and nonpumping conditions, together with the other geophysical logs, indicate five transmissive fracture zones. More than 90 percent of the open-hole transmissivity is associated with a fracture zone 272 feet BLS (below land surface). A transmissive zone at 787 feet BLS that consists of nearly parallel fractures lies within the projected tunnel path; here the hydraulic head is 12 to 15 feet lower than that of transmissive zones above the 315-foot depth. The 60-megahertz directional borehole radar logs indicate the location and orientation of two closely spaced radar reflectors that would intersect the projection of the borehole below its drilled depth. Subsequent excavation of the tunnel past the borehole allowed comparison of the log analysis with conditions observed in the tunnel. The tunnel was found to intersect gneiss with southeastward dipping foliation; many nearly horizontal fractures; and a southeastward dipping fracture zone whose location, character, and orientation was consistent with that of the mapped radar reflectors. The fracture zone produced inflow to the tunnel at a rate of 50 to 100 gallons per minute. All conditions indicated by the logging methods were consistent with those observed within the tunnel.

New York↗

Hydrogeology of Picacho Basin, south-central Arizona

The hydrogeology of Picacho Basin was studied to define the stratigraphy, basin structure, physical and hydraulic properties of the basin sediments, and predevelopment and postdevelopment conditions of ground-water flow as of 1985. The study area includes about 900 square miles and contains a sedimentfilled asymmetric graben. The greatest sediment thickness occurs along the east margin of the graben. Basin sediments contain the principal water-bearing units and are separated into lower, middle, and upper units. The lower unit is several thousand feet thick and contains a conglomerate facies and a playa facies that contains a thick evaporite sequence. The middle and upper units contain alluvial and playa facies that are as much as 1,500 feet thick. Ground water occurs in lower and upper aquifer systems separated by a middle confining unit that comprises the playa facies of the three units. Hydraulic properties and compressibility of the middle and upper units are much greater than those of the lower unit. Vertical-head gradients exist, and vertical flow occurs within and between the aquifer systems. Early development of surface-water supplies resulted in increased recharge through deep percolation of irrigation water. Later development of the ground-water supplies resulted in extensive water-level declines, changes in the direction of ground-water flow, removal of water from storage, aquifer compaction, land subsidence, and earth fissures. Dewatering of pore spaces in the upper unit has been the primary source of water; however, as much as 80 percent of the water derived from storage in the Eloy area has resulted from compaction of pore spaces.

Arizona↗

Estimated recharge to the Madison and Minnelusa aquifers in the Black Hills area, South Dakota and Wyoming, water years 1931-98

The Madison and Minnelusa aquifers are two of the most important aquifers in the Black Hills area. Long-term estimates of recharge to the Madison and Minnelusa aquifers are important for managing the water resources in the Black Hills area. Thus, annual recharge from streamflow losses and infiltration of precipitation on outcrop areas is estimated for water years 1931-98. All estimates are for recharge that contributes to regional ground-water flow patterns and that occurs in outcrop areas connected to the regional flow system. Estimates exclude recharge to outcrop areas that are isolated from the regional flow system, which generally results in ground-water discharge to area streams. Streamflow recharge is calculated directly for 11 streams in the Black Hills area that have continuous-record gaging stations located upstream from loss zones, using available records of daily streamflow, against which estimated loss thresholds (from previous investigations) are applied. Daily streamflow records are extrapolated, when necessary, using correlations with long-term gages, to develop annual estimates of streamflow recharge for 1950-98. Streamflow recharge is estimated for a number of smaller basins using loss thresholds for miscellaneous-record sites. Annual recharge estimates are derived from synthetic records of daily streamflow for 1992-98, which are based on drainage-area ratios applied to continuous-record gaging stations. Recharge estimates are further extrapolated for 1950-91, based on the average percentage of streamflow recharge contributed by these basins during 1992-98, relative to overall streamflow recharge.Streamflow recharge also is estimated for small drainage areas with undetermined loss thresholds that are situated between larger basins with known thresholds. Estimates for 1992-98 are based on estimates of annual streamflow derived using drainage-area ratios, with assumed losses equal to 90 percent of annual streamflow. Recharge estimates also are extrapolated for 1950-91, based on the average percentage of streamflow recharge contributed by these basins.Precipitation recharge for 1931-98 is estimated using relations between precipitation and streamflow (or basin yield) for representative gaging stations. Basin yields are first normalized, relative to drainage area, by expressing in inches per unit of drainage area. Yields are further converted to yield efficiencies, by dividing by precipitation on contributing drainage areas. Relations between yield efficiency and precipitation are identified, which are developed for use in generically estimating annual yield for given areas, based on average yield efficiency and annual precipitation. The resulting annual yield is used as a surrogate for estimating annual recharge from infiltration of precipitation on outcrop areas of the Madison and Minnelusa aquifers. Annual yield (or recharge) efficiencies are estimated to range from about 2 percent to in excess of 30 percent, with corresponding average annual recharge estimates ranging from 0.4 inch in the southern Black Hills to about 8.7 inches in the northwestern Black Hills.Estimates of precipitation recharge for 1931-49 are used to estimate streamflow recharge for the same period, based on correlations between the two variables for 1989-98. Combined streamflow and precipitation recharge to both aquifers averaged about 344 ft3/s for 1931-98. Streamflow recharge averaged about 93 ft3/s, or 27 percent of combined recharge, and precipitation recharge averaged about 251 ft3/s, or 73 percent of combined recharge. Combined recharge ranged from 62 ft3/s in 1936 to 847 ft3/s in 1995. The lowest recharge amounts generally occurred during the 1930?s; however, a more prolonged period of low recharge occurred during 1947-61.For 1931-98, average precipitation recharge to the Madison aquifer is about 3.6 inches, compared with 2.6 inches for the Minnelusa aquifer. However, recharge volumes to these aquifers are nearly identical because th

Water-Resources Investigations Report↗

Optimization of ground-water withdrawal at the old O-Field area, Aberdeen Proving Ground, Maryland

The U.S. Army disposed of chemical agents, laboratory materials, and unexploded ordnance at the Old O-Field landfill at Aberdeen Proving Ground, Maryland, beginning prior to World War II and continuing until at least the 1950?s. Soil, ground water, surface water, and wetland sediments in the Old O-Field area were contaminated by the disposal of these materials. The site is in the Atlantic Coastal Plain, and is characterized by a complex series of Pleistocene and Holocene sediments formed in various fluvial, estuarine, and marine-marginal hydrogeologic environments. A previously constructed transient finite-difference ground-water-flow model was used to simulate ground-water flow and the effects of a pump-and-treat remediation system designed to prevent contaminated ground water from flowing into Watson Creek (a tidal estuary and a tributary to the Gunpowder River). The remediation system consists of 14 extraction wells located between the Old O-Field landfill and Watson Creek.Linear programming techniques were applied to the results of the flow-model simulations to identify optimal pumping strategies for the remediation system. The optimal management objective is to minimize total withdrawal from the water-table aquifer, while adhering to the following constraints: (1) ground-water flow from the landfill should be prevented from reaching Watson Creek, (2) no extraction pump should be operated at a rate that exceeds its capacity, and (3) no extraction pump should be operated at a rate below its minimum capacity, the minimum rate at which an Old O-Field pump can function. Water withdrawal is minimized by varying the rate and frequency of pumping at each of the 14 extraction wells over time. This minimizes the costs of both pumping and water treatment, thus providing the least-cost remediation alternative while simultaneously meeting all operating constraints.The optimal strategy identified using this objective and constraint set involved operating 13 of the 14 extraction wells at rates ranging from 0.4 to 4.9 gallons per minute.

Water-Resources Investigations Report↗