Geology Reports⌕ Search

SEARCH · Geology Reports

Results for “Test”

Search indexed USGS publications on groundwater, aquifers, geologic maps, mineral resources and earthquakes. Explore source records by subject and place.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39Linked to original sources

Drilling, construction, and aquifer-test data from wells 3-3307-20 and -21, Thompson Corner exploratory wells I and II, Oahu, Hawaii

The Thompson Corner exploratory wells I and II (State well numbers 3-3307-20 and -21) were drilled near Thompson Corner, about 2.2 miles south-southwest of the town of Haleiwa. The wells are located on agricultural land in the Waialua ground-water area. The wells are about 50 feet apart and penetrate about 90 feet into the ground water. Aquifer tests were conducted using well 3-3307-20 as a pumping well and well 3-3307-21 as an observation well. Well-construction data, logs of drilling notes, geologic descriptions for the samples, and aquifer-test data are presented for the wells. The wells are two of twelve exploratory wells drilled in the north-central Oahu area between July 1993 and May 1994 in cooperation with the Honolulu Board of Water Supply.

Open-File Report↗

Field test of two single-frequency GPS receivers

The U.S. Geological Survey's Cascades Volcano Observatory (CVO) has been testing low-cost, low-power Global Positioning System (GPS) receivers for use in the monitoring of restless volcanoes. Field tests of two single-frequency (L1 only) receivers, the Ashtech SCA-12S and the Leica SR261 show that these units can measure positions precisely enough to meet our monitoring needs. For line lengths up to 10 kilometers, I have found repeatibilities to be less than a centimeter for horizontal coordinates. Hourly data using broadcast orbits was processed using manufacturer and Bernese software. Repeatibilities were similar for both data sets.

Open-File Report↗

Geologic map of Paleozoic rocks in the Calico Hills, Nevada Test Site, southern Nevada

The Calico Hills area in the southwestern part of the Nevada Test Site, Nye County, Nevada, exposes a core of pre-Tertiary rocks surrounded by middle Miocene volcanic strata. This map portrays the very complex relationships among the pre-Tertiary stratigraphic units of the region. The Devonian and Mississippian rocks of the Calico Hills are distinct from age-equivalent carbonate-shelf or submarine-fan strata in other parts of the Nevada Test Site. The Calico Hills strata are interpreted to have been deposited beyond the continental shelf edge from alternating silicic and carbonate clastic sources. Structures of the Calico Hills area record the compounded effects of: 1) eastward-directed, foreland-vergent thrusting; 2) younger folds, kink zones, and thrusts formed by hinterland-vergent deformation toward northwesterly and northerly directions; and 3) low-angle normal faults that displaced blocks of Middle Paleozoic carbonate strata across the contractionally deformed terrane. All of these structures are older than any of the middle Miocene volcanic rocks that were erupted across the Calico Hills.

Nevada↗

Design, operation, and data analysis for a wireline packer system in open boreholes, with field-test results from Belvidere, Illinois

A wireline-operated packer was designed for use with a standard geophysical logging system. The packer probe consists of a downhole packer inflated with water removed from the borehole by an in-line submersible pump, and a differential pressure transducer calibrated to measure the hydraulic-head difference between the zones above and below the packer. Analysis of the packer data is based on a numerical model that predicts the water levels above and below the packer for a given set of aquifer zones of specified hydraulic head and transmissivity. Various computations are used to indicate the sensitivity of the packer measurements to the hydraulic head and transmissivity contrasts between aquifer zones. The wireline-packer probe was field tested in a series of open-bedrock boreholes in Belvidere, Illinois, at a site where vertical hydraulic-head differences are produced in a horizontally stratified aquifer by water production from an underlying aquifer. Analysis of the wireline-packer data produced estimates of hydraulic-head gradient and aquifer-zone transmissivity consistent with results from straddle-packer hydraulic tests. However, the wireline-packer data also indicated that there are significant variations of vertical hydraulic gradient with depth, and that the gradient is sharply reversed near the bottom of the boreholes. This result is consistent with upward ambient flow measured on previous occasions near the bottom of these boreholes, and has important consequences for the monitoring of ground-water flow at the study site.

Illinois↗

Geology, hydrology, and results of tracer testing in the Galena-Platteville aquifer at a waste-disposal site near Byron, Illinois

A study was conducted by the U.S. Geological Survey and the U.S. Environmental Protection Agency of the geohydrology of the dolomite bedrock at a waste-disposal site near Byron, Illinois. The study was designed to identify and characterize the flow pathways through the bedrock aquifer beneath the site. The geologic units of concern at the site are the Glenwood Formation of the Ancell Group, and the Platteville and Galena Groups. These deposits compose the Galena-Platteville aquifer and the underlying Harmony Hill Shale semiconfining unit. The Galena-Platteville aquifer is an unconfined aquifer. Geophysical logging, water levels, and aquifer-test data indicate the presence of interconnected, hydraulically active fractures in the middle of the Galena-Platteville aquifer (the upper flow pathway), and a second set of hydraulically active fractures (the lower flow pathway). The lower flow pathway may be present through much of the site. Few hydraulically active fractures are present in the upper part of the aquifer near the center of the site, but appear to be more numerous in the upper part of the aquifer in the western and northeastern parts of the site. Water-level data obtained during the tracer test indicate that pumping effects were present near the pumped wells. Pumping effects may have been present at several wells located along directions of identified fracture orientation from the pumped well. The upper part of the aquifer did not appear to be hydraulically well connected to the flow pathways supplying water to the pumped well. Large background changes in water levels obscured the effects of pumping and prevented calculation of aquifer properties. The velocity of the bromide tracer through the lower flow pathway under the hydraulic gradient resulting from the pumping was about 152 feet per day. Solution of the Darcy velocity equation results in a calculated effective porosity for this interval of 3.5 percent, indicating hydraulic interconnection between the fractures and the aquifer matrix. Ground-water velocity through the lower flow pathway was calculated to be 15.4 feet per day under hydrostatic conditions.

Illinois↗

Selected data for wells and test holes used in structure-contour maps of the Inyan Kara Group, Minnekahta Limestone, Minnelusa Formation, Madison Limestone, and Deadwood Formation in the Black Hills area, South Dakota

This report presents selected data on wells and test holes that were used in the construction of structure-contour maps of selected formations that contain major aquifers in the Black Hills area of western South Dakota. Altitudes of the top of the Inyan Kara Group, Minnekahta Limestone, Minnelusa Formation, Madison Limestone, and Deadwood Formation are presented for the wells and test holes presented in this report.

South Dakota↗

Evaluation of geophysical logs and slug tests, phase II, at AIW Frank/Mid-County Mustang Superfund Site, Chester County, Pennsylvania

Between September 1997 and October 1998, nine monitor wells were drilled at the AIW Frank/Mid-County Mustang Superfund Site in Chester County, Pa., to determine the horizontal and vertical distribution of contaminated ground water migrating from known contaminant sources. The U.S. Geological Survey conducted borehole geophysical logging and borehole television surveys in these boreholes to identify water-producing zones so that appropriate intervals could be screened in each borehole. Caliper logs and borehole television surveys were used to locate fractures; inflections on fluid-temperature and fluid-resistivity logs were used to locate possible water-bearing fractures, and heatpulseflowmeter measurements verified these locations. The borehole television surveys indicated that locally, the rocks of the Conestoga Limestone and Ledger Dolomite that underlie the site strike generally from northeast-southwest to east-west and dip steeply to the southeast and south approximately 63? to 76?. Slug tests were conducted at six boreholes to estimate transmissivity. Transmissivity from slug tests ranged from 21 feet squared per day in borehole CH-5669 to greater than 12,000 feet squared per day in boreholes CH-5665 and CH-5667. After interpretation of geophysical logs, borehole television surveys, and driller's logs, all boreholes were screened such that water-level fluctuations could be monitored and discrete water samples collected from one or more water-producing zones in each borehole.

Open-File Report↗

Field tests of nylon-screen diffusion samplers and pushpoint samplers for detection of metals in sediment pore water, Ashland and Clinton, Massachusetts, 2003

Efficient and economical screening methods are needed to detect and to determine the approximate concentrations of potentially toxic trace-element metals in shallow groundwater- discharge areas (pore water) where the metals may pose threats to aquatic organisms; such areas are likely to be near hazardous-waste sites. Pushpoint and nylon-screen diffusion samplers are two complementary options for use in such environments. The pushpoint sampler, a simple well point, is easy to insert manually and to use. Only 1 day is required to collect samples. The nylon-screen diffusion sampler is well suited for use in sediments that do not allow a pump to draw water into a pushpoint sampler. In this study, both types of devices were used in sediments suitable for the use of the pushpoint sampler. Sampling with the nylon-screen diffusion sampler requires at least two site visits: one to deploy the samplers in the sediment, and a second to retrieve the samplers and collect the samples after a predetermined equilibration period. Extensive laboratory quality-control studies, field testing, and laboratory analysis of samples collected at the Nyanza Chemical Waste Dump Superfund site along the Sudbury River in Ashland, Massachusetts, and at a Superfund site-assessment location on Rigby Brook in Clinton, Massachusetts, indicate that these two devices yield comparable results for most metals and should be effective tools for pore-water studies. The nylon-screen diffusion samplers equilibrated within 1-2 days in homogeneous, controlled conditions in the laboratory. Nylon-screen diffusion samplers that were not purged of dissolved oxygen prior to deployment yielded results similar to those that were purged. Further testing of the nylon-screen diffusion samplers in homogeneous media would help to resolve any ambiguities about the data variability from the field studies. Comparison of data from replicate samples taken in both study areas shows that even samples taken from sites within a half-meter radius of one another have distinct differences in pore-water trace-element concentrations. Sequential replicate samples collected with the pushpoint sampler yield consistent results; moving the pushpoint sampler even 5 to 10 centimeters, however, generally produces a second set of data that differs enough from the first set of data to indicate a heterogeneous environment. High concentration biases for barium and zinc in laboratory and field samples collected with nylon-screen diffusion samplers, however, may make their use inappropriate for studies of these metals. Analyzing samples with high iron concentrations required sample dilution by factors of 2 or 10. Because these dilutions caused increases in the reporting levels by the same proportion, a substantial fraction of the data was censored. The results from undiluted samples, however, indicate that both devices should be useful for sampling ground water with metal concentrations close to reporting limits.

Scientific Investigations Report↗

Assessing hydraulic connections across a complex sequence of volcanic rocks - Analysis of U-20 WW multiple-well aquifer test, Pahute Mesa, Nevada National Security Site, Nevada

Groundwater beneath Pahute Mesa flows through a complexly layered sequence of volcanic rock aquifers and confining units that have been faulted into distinct structural blocks. Hydraulic property estimates of rocks and structures in this flow system are necessary to assess radionuclide migration near underground nuclear testing areas. The U.S. Geological Survey (USGS) used a 12 month (October 1, 2008&mdash; October 1, 2009) intermittent pumping schedule of well U-20 WW and continuously monitored water levels in observation wells ER-20-6 #3, UE-20bh 1, and U-20bg as a multi-well aquifer test to evaluate hydraulic connections across structural blocks, bulk hydraulic properties of volcanic rocks, and the hydraulic significance of a major fault. Measured water levels were approximated using synthetic water levels generated from an analytical model. Synthetic water levels are a summation of environmental water-level fluctuations and a Theis (1935) transform of the pumping signal from flow rate to water-level change. Drawdown was estimated by summing residual differences between measured and synthetic water levels and the Theis-transformed pumping signal from April to September 2009. Drawdown estimates were used in a three‑dimensional numerical model to estimate hydraulic properties of distinct aquifers, confining units, and a major fault. A maximum water-level drawdown of nearly 0.4 foot in well UE-20bh 1, which is more than 1 mile from the pumping well, was detected across a major fault. Drawdown estimates in the observation well nearest to (ER-20-6 #3, less than 1 mile) and within the same structural block as the pumping well were less than detection (<0.1 foot). Minimal drawdown within the same structural block indicates that lava units are likely separated by bedded tuff confining units. Hydraulic property estimates indicate that wells U-20 WW, UE-20bh 1, and ER-20-6 #3 produce water from moderately permeable fractured lava, as hydraulic conductivity and specific storage estimates average 4.8 feet per day and 2.1&times;10 &ndash;6 per foot, respectively, and transmissivity estimates range from 1,200 to 3,600 feet squared per day. Sensitivity analyses indicate that the major fault is hydraulically similar to the permeable host rock and connects flow between structural blocks.

Nevada↗

Geophysical-log and hydraulic-test analyses of groundwater-production wells at the Hannahville Indian Community, Menominee County, Michigan

The U.S. Geological Survey, in cooperation with the Hannahville Indian Community, evaluated the geohydrology of the bedrock formations and hydraulic properties of groundwater-production wells at the Hannahville Indian Community in Menominee County, Michigan. Geophysical logs were collected from five wells at two sites during September 2012. The logs were analyzed to characterize the lithostratigraphy, bedding and fractures, and hydraulic properties of the geologic formations and aquifers beneath the Hannahville Indian Community. The geophysical logs collected included natural gamma radiation, electromagnetic conductivity, wellbore image, caliper, ambient and stressed flowmeter, fluid resistivity, temperature, and wellbore deviation. The geophysical logs were analyzed with results from short-term hydraulic tests to estimate the transmissivity and water-level altitudes of flow zones penetrated by the wells. The geophysical log analysis indicated the wells penetrated four distinct lithostratigraphic units—shale and carbonate rock, upper carbonate rock, carbonate rock and glauconitic sandstone, and lower carbonate rock. Most of the fractures penetrated by the wellbores appeared to be related bedding partings. The lower carbonate rock unit contained solution features. Analysis of the geophysical logs and hydraulic tests indicated that each of the five wells penetrated from one to four flow zones. The Casino 5 well penetrated a flow zone that was associated with solution features and had an estimated total transmissivity of 4,280 feet squared per day (ft 2 /d), the highest estimate for all the wells. The Casino 3 well penetrated four flow zones and had an estimated total transmissivity of 3,570 ft 2 /d. The flow zones penetrated in the lower carbonate rock unit by the Casino 3 and 5 wells were hydraulically connected. The Golf Shack well penetrated two flow zones and had an estimated total transmissivity of 40 ft 2 /d, the lowest estimate for all the wells. The Community 1 and Community 2 wells penetrated three and four flow zones, respectively, and had estimated total transmissivity values of 185 and 280 ft 2 /d, respectively.

Michigan↗

Occurrence and concentrations of selected trace elements, halogenated organic compounds, and polycyclic aromatic hydrocarbons in streambed sediments and results of water-toxicity testing in Westside Creeks and the San Antonio River, San Antonio, Texas, 2014

Sediment samples and samples for water-toxicity testing were collected during 2014 from several streams in San Antonio, Texas, known locally as the Westside Creeks (Alazán, Apache, Martínez, and San Pedro Creeks) and from the San Antonio River. Samples were collected during base flow and after periods of stormwater runoff (poststorm conditions) to determine baseline sediment- and water-quality conditions. Streambed-sediment samples were analyzed for selected constituents, including trace elements and organic contaminants such as pesticides, polychlorinated biphenyls (PCBs), brominated flame retardants, and polycyclic aromatic hydrocarbons (PAHs). Potential risks of contaminants in sediment were evaluated by comparing concentrations of contaminants in sediment to two effects-based sediment-quality guidelines: (1) a lower level, called the threshold effect concentration, below which, harmful effects to benthic biota are not expected, and (2) a higher level, the probable effect concentration (PEC), above which harmful effects are expected to occur frequently. Samples for water-toxicity testing were collected from each stream to provide information about fish toxicity in the study area. The trace metal lead was detected at potentially toxic concentrations greater than the PEC in both the base-flow and poststorm samples collected at two sites sampled on San Pedro Creek. The PECs for the pesticides dichlorodiphenyldichloroethane, dichlorodiphenyldichloroethylene, dichlorodiphenyltrichloroethane, and chlordane were exceeded in some of the samples at the same two sites on San Pedro Creek. Brominated flame retardants and polybrominated diphenyl ether (PBDE) 85, 153, and 154 were found in all streambed-sediment samples. Federal Environmental Quality Guidelines established by Environment Canada for PBDE 99 and PBDE 100 were exceeded in all samples in which PBDE 99 was detected and in a majority of the samples in which PBDE 100 was detected; the greatest concentrations occurred in samples collected at the same two sites on San Pedro Creek where the samples containing elevated lead and pesticide concentrations were collected. All concentrations of total PCBs (computed as the sum of the 18 reported PCB congeners) in the individual streambed-sediment samples were less than the threshold effect concentration, but the concentrations were elevated in the two sites on San Pedro Creek compared to concentrations at other sites. At one site on Apache Creek, 6 of the individual PAHs measured in the sample collected during base-flow conditions exceeded the PECs and 8 of the 9 PECs were exceeded in the sample collected during poststorm conditions. The total PAH concentration in the sample collected at the site during poststorm conditions was 3.3 times greater than the PEC developed for total PAHs. Average PAH profiles computed for base-flow samples and poststorm samples most closely resemble the parking lot coal-tar sealcoat dust PAH source profile, defined as the average PAH concentrations in dust swept from parking lots in six cities in the United States that were sealed with a black, viscous liquid containing coal-tar pitch. Six of ten water samples collected during base-flow conditions caused reductions in Pimephales promelas (fathead minnow) survival and were considered to be toxic.

Texas↗

Geological investigations in the U12b.03 and U12b.04 tunnels, Nevada Test Site

The papers comprising the various parts of this report contain preliminary results of the U. S. Geological Survey investigations in the U12b.03 and U12b.04 tunnels at the Nevada Test Site, Nye County, Nevada (fig. 1). The geologic studies were undertaken to define the structural, chemical, mineralogic, and some of the physical properties of the tuffaceous rocks that enclose the explosion chambers at the end of each tunnel. The U12b.03 and .04 tunnels are part of the U12b (Rainier) tunnel complex that was driven northwestward from the steep east slope of Rainier Mesa (a prominent topographic feature in the northwest part of the Test Site (fig . 2)). The U12b.03 tunnel trends north from a point about 980 feet from the portal of the U12b tunnel (fig. 3). The U12b.03 tunnel consists of 620 feet of tunnel, two alcoves, and a shot chamber. The tunnel is irregular, ranging from 6 to 10 feet in width, and 6 to 9 feet in height. The shot chamber at the north end of the tunnel is 22 feet on each sidee The vertical and minimum cover over the shot chamber are 610 and 510 feet, respectively.

Nevada↗

Development and testing of method for assessing and mapping agricultural areas susceptible to atrazine leaching in the state of Washington

In a joint effort by the Washington State Department of Agriculture, the Washington Department of Ecology, and the U.S. Geological Survey, the Environmental Protection Agency's Pesticide Root Zone Model and a Geographic Information System were used to develop and test a method for screening and mapping the susceptibility of ground water in agricultural areas to pesticide contamination. The objective was to produce a map that would be used by the Washington State Department of Agriculture to allocate resources for monitoring pesticide levels in ground water. The method was tested by producing a map showing susceptibility to leaching of the pesticide atrazine for the Columbia Basin Irrigation Project, which encompasses an area of intensive agriculture in eastern Washington. The reliability of the atrazine map was assessed by using statistical procedures to determine whether the median of the percentage of atrazine simulated to leach below the root zone in wells where atrazine was detected was statistically greater than the median percentage at wells where atrazine was not detected (at or above 0.001 microgram per liter) in 134 wells sampled by the U.S. Geological Survey. A statistical difference in medians was not found when all 134 wells were compared. However, a statistical difference was found in medians for two subsets of the 134 wells that were used in land-use studies (studies examining the quality of ground water beneath specific crops). The statistical results from wells from the land-use studies indicate that the model potentially can be used to map the relative susceptibility of agricultural areas to atrazine leaching. However, the distinction between areas of high and low susceptibility may not yet be sufficient to use the method for allocating resources to monitor water quality. Several options are offered for improving the reliability of future simulations.

Water-Resources Investigations Report↗

Evaluation of tracer tests completed in 1999 and 2000 on the upper Santa Clara River, Los Angeles and Ventura Counties, California

The interaction of surface water and hyporheic water along the Santa Clara River in Los Angeles and Ventura Counties, California, was evaluated by conducting tracer tests and analyzing water-quality data under different flow conditions in October 1999 and May 2000. Tracer and water-quality samples were collected at multiple river and hyporheic sites as well as at the Los Angeles County Sanitation Districts Saugus and Valencia Water Reclamation Plants. These water reclamation plants provide the main source of base flow in the river. Rhodamine WT dye was injected into the river to determine river traveltimes and to indicate when Lagrangian water-quality sampling could be performed at each site. Sodium bromide was injected into the river at a constant rate at the water reclamation plants to evaluate the surface-water and shallow ground-water interactions in the hyporheic zone. In the upper reach of the study area, which extends 2.9 river miles downstream from the Saugus Water Reclamation Plant, traveltime was 3.2 hours during May 2000. In the lower reach, which extends 14.1 river miles downstream from the Valencia Water Reclamation Plant, traveltime was 9.6 hours during October 1999 and 7.1 hours during May 2000. The sodium bromide tracer was detected at both hyporheic locations sampled during October 1999, and at two of the three hyporheic locations sampled during May 2000. On the basis of Rhodamine dye tests, flow curves were constructed from the discharge measurements in the Valencia reach. Flow-curve results indicate net gains in flow throughout most, but not all, of the upper parts of the reach and net losses in flow at the lower part of the reach. Lagrangian water-quality sampling provides information on the changes in chemistry as the water flows downstream from the water reclamation plants. Along both reaches there is an increase in sulfate (40-60 mg/L in the Saugus reach and 160 mg/L in the Valencia reach) and a decrease in chloride (about 45 mg/L in the Saugus reach and about 10 mg/L in the Valencia reach). The increasing sulfate concentrations are consistent with discharge of higher sulfate ground water into the river. Along both reaches there is a trend of decreasing ammonia and slightly increasing nitrate concentrations. This trend is consistent with nitrification. Samples were also analyzed for numerous compounds associated with wastewater, but analysis focused on four indicators. Concentrations of wastewater indicators in the Santa Clara River were low and decreased downstream from the reclamation plants. There is general consistency between the chemical and tracer data collected from the hyporheic and the river-aquifer flow regime within a reach. The water quality at the hyporheic site in a gaining reach of the river resembled that of the local ground water and no wastewater indicators or injected tracers were observed; whereas, the water quality at the hyporheic sites in a losing reach of the river resembled the water quality of the river at the corresponding river site, and injected tracers were observed.

California↗

Aquifer tests in the Summit reach of the proposed Cross-Florida Barge Canal near Ocala, Florida

Values for the horizontal and vertical hydraulic conductivity of Floridan aquifer materials are estimated by analyses of specially-designed aquifer tests at three sites along the Summit Pool reach of the proposed Cross-Florida Barge Canal for use in evaluating the exchange of water between the aquifer and the canal. Methods are described that deal with unique boundary conditions and aquifer anisotropy at two sites. Extreme aquifer heterogeneity precluded the determination of aquifer coefficients at one of the sites and probably affected the results of the tests at the other two. Therefore, the calculated aquifer coefficients reported should be regarded only as estimates. Calculated coefficients of horizontal hydraulic conductivity ranged from 0.025 to 3,500 gallons per day per square foot (0.0010 to 143 metres per day) and calculated coefficients of vertical hydraulic conductivity ranged from 0.05 to 23,000 gallons per day per square foot (0.0021 to 943 metres per day). Ratio of horizontal to vertical hydraulic conductivity ranged from 0.09 to 2.9.

Florida↗

Calibration and testing of selected portable flowmeters for use on large irrigation systems

Existing methods for measuring discharge of irrigation systems in the High Plains region are not suitable to provide the pumpage data required by the High Plains Regional Aquifer System Analysis. Three portable flowmeters that might be suitable for obtaining fast and accurate discharge measure-ments on large irrigation systems were tested during 1979 under both laboratory and field conditions: propeller type gated-pipe meter, a Doppler meter, and a transient-time meter. The gated-pipe meter was found to be difficult to use and sensitive to particulate matter in the fluid. The Doppler meter, while easy to use, would not function suitably on steel pipe 6 inches or larger in diameter, or on aluminum pipe larger than 8 inches in diameter. The transient-time meter was more difficult to use than the other two meters; however, this instrument provided a high degree of accuracy and reliability under a variety of conditions. Of the three meters tested, only the transient-time meter was found to be suitable for providing reliable discharge measurements on the variety of irrigation systems used in the High Plains region.

High Plains Aquifer↗

Hydrogeology of the Cambrian-Ordovician aquifer system at a test well in northeastern Illinois

A 3,475-ft-deep test well was drilled in northeastern Illinois near Lake Michigan and the Illinois-Wisconsin State line as part of a regional hydrologic study of the Cambrian-Ordovician aquifer. The well penetrates the Cambrian-Ordovician aquifer system and 40 ft of Precambrian granite. From oldest to youngest the aquifer system consists of the lower Mount Simon aquifer, Mount Simon confining unit, Elmhurst-Mount Simon aquifer, Eau Claire confining unit, Ironton-Galesville aquifer, Franconia confining unit, St. Peter aquifer, and an upper confining unit composed of the Glenwood Formation, Galena Dolomite and Platteville Limestone, and Maquoketa Shale. Aquifer tests were performed on hydrogeologic units that were isolated with inflatable packers. Results indicate that the Ironton-Galesville aquifer has the highest hydraulic conductivity - 10 ft/day. The St. Peter and Elmhurst-Mount Simon aquifers have hydraulic conductivities of 1.8 and 1.5 ft/day, respectively. The Mount Simon confining bed has a hydraulic conductivity of 1.3 ft/day. The Mount Simon confining unit confines saline water present in the lower Mount Simon aquifer. The dissolved solids concentration in water from this aquifer is > than 55,000 mg/L, and the head is at least 50 ft higher than heads in any of the overlying Cambrian and Ordovician aquifers. (USGS)

Water-Resources Investigations Report↗

Development and testing of highway storm-sewer flow measurement and recording system

A comprehensive study and development of measuring instruments and techniques for measuring all components of flow in a storm-sewer drainage system was undertaken by the U.S. Geological Survey under the sponsorship of the Federal Highway Administration. The study involved laboratory and field calibration and testing of measuring flumes, pipe insert meters, weirs, electromagnetic velocity meters as well as the development and calibration of pneumatic-bubbler pressure transducer head measuring systems. Tracer-dilution and acoustic flow meter measurements were used in field verification tests. A single micrologger was used to record data from all the above instruments as well as from a tipping-bucket rain gage and also to activate on command the electromagnetic velocity meter and tracer-dilution systems. (Author 's abstract)

Water-Resources Investigations Report↗