Geology ReportsSearch

SEARCH · Geology Reports

Results for “Ground Water Monitoring and Remediation”

Search indexed USGS publications on groundwater, aquifers, geologic maps, mineral resources and earthquakes. Explore source records by subject and place.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3Linked to original sources

Design and implementation of evapotranspiration measuring equipment for Owens Valley, California

As part of a plant survivability and ground water study in Owens Valley, California, semipermanent installations are used to measure continuous range‐land evapotranspiration in the valley's phreatophyte community. A proposed mobile installation also has been designed. The semipermanent micrometeoro‐logical station collects continuous data for solution of the Bowen ratio/energy budget equation and the Penman combination equation. Three sites were chosen for this type of installation to provide a representative sampling of Owens Valley. The proposed mobile aerodynamic installation should be capable of calculating evapotranspiration by the eddy correlation method. This instrumentation will be used throughout the valley for short periods of time (up to five days). Many problems with equipment operation, calibration and design have been identified and resolved by means of improved calibration techniques, systematic error‐removal techniques, reduced cycle times, modified equipment design and proper observer training. The collected evapotranspiration data will be instrumental in developing a one‐dimensional evapotranspiration flux algorithm for a model of valleywide ground water flow.

California

Geohydrology and contamination at the Michigan Department of Transportation maintenance garage area, Kalamazoo County, Michigan

A leaking underground storage tank was removed from the Michigan Department of Transportation maintenance garage area in Kalamazoo County., Mich., in 1985. The tank had been leaking unleaded gasoline. Although a remediation system was operational at the site for several years after the tank was removed, ground-water samples collected from monitoring wells in the area consistently showed high concentrations of benzene, toluene. ethylbenzene, and xylenes--indicators of the presence of gasoline. The U.S. Geological Survey did a study in cooperation with the Michigan Department of Transportation, to define the geology, hydrology, and occurrence of gasoline contamination in the maintenance garage area. The aquifer affected by gasoline contamination is an unconfined glaci'a.l sand and gravel aquifer. The average depth to water in the study area is about 74.7 feet. Water-level fluctuations are small; maximum fluctuation was slightly more than 1 foot during August 1993-August 1994. Hydraulic conductivities based on aquifer-test data collected for the study and estimated by use of the Cooper-Jacob method of solution ranged from 130 to 144 feet per day. Ground water is moving in an east-southeasterly direction at a rate of about I foot per day. Leakage from perforated pipes leading from the underground storage tanks to the pump station was identified as a second source of gasoline contamination to saturated and unsaturated zones. The existence of this previously unknown second source is part of the reason that previous remediation efforts were ineffective. Residual contaminants in the unsaturated zone are expected to continue to move to the water table with recharge, except in a small area covered by asphalt at the land surface. The gasoline plume from the perforated pipe source has merged with that from the leaking underground storage tank, and the combined plume in the saturated zone is estimated to cover an area of 30,000 square feet. The combined plume is in the upper 20 feet of the saturated zone. The relative distribution of benzene, toluene, ethylbenzene, and xylenes indicate that factors such as sorption, solubility, and susceptibility to microbial degradation are affecting the movement of the combined plume. Given these factors, the plume is expected to move at a rate of less than 1 foot per day.

Michigan

Results of a monitoring program of continuous water levels and physical water properties at the Operable Unit 1 area of the Savage Municipal Well Superfund site, Milford, New Hampshire, water years 2000-03

The Milford-Souhegan glacial-drift (MSGD) aquifer, in south-central New Hampshire, is an important source of industrial, commercial, and domestic water. The MSGD aquifer was also an important source of drinking water for the town of Milford until it was found to contain high concentrations of volatile organic compounds (VOCs) in the Savage and Keyes municipal-supply wells in the early 1980s. A VOC plume was found to cover part of the southwestern half of the MSGD aquifer. In September 1984, the site was designated a Superfund site, called the Savage Municipal Well Superfund site. The primary source area of contaminants was a former tool manufacturing facility (called the OK Tool facility, and now called the Operable Unit 1 (OU1) area) that disposed of solvents at the surface and in the subsurface. The facility was closed in 1987 and removed in 1998. A low-permeability containment barrier wall was constructed and installed in the overburden (MSGD aquifer) in 1998 to encapsulate the highest concentrations of VOCs, and a pump-and-treat remediation facility was also added. Remedial operations of extraction and injection wells started in May 1999. A network of water-level monitoring sites was implemented in water year 2000 (October 1, 1999, through September 30, 2000) in the OU1 area to help assess the effectiveness of remedial operations to mitigate the VOC plume, and to evaluate the effect of the barrier wall and remedial operations on the hydraulic connections across the barrier and between the overburden and underlying bedrock. Remedial extraction and injections wells inside and outside the barrier help isolate ground-water flow inside the barrier and the further spreading of VOCs. This report summarizes both continuous and selected periodic manual measurements of water level and physical water properties (specific conductance and water temperature) for 10 monitoring locations during water years 2000-03. Additional periodic manual measurements of water levels were made at four nearby monitoring wells. Water levels are referenced to periods of remedial extraction and injection operations. Remedial extraction inside the barrier in the overburden causes water-level drawdowns in interior (inside the barrier) monitoring wells but also exterior (outside the barrier) monitoring wells. Drawdowns were observed in the following descending sequence at: interior overburden wells, interior underlying bedrock wells, exterior underlying bedrock wells, and exterior overburden wells.

Open-File Report

Time-series monitoring in fractured-rock aquifers

Time-lapse monitoring of subsurface processes is an emerging and promising area of hydrogeophysics. The combined use of non-invasive or minimally invasive geophysical methods with hydraulic and geochemical sampling is a cost-effective approach for aquifer characterization, long-term aquifer monitoring, and remediation monitoring. Time-lapse geophysical surveys can indirectly measure time-varying hydrologic parameters such as fluid saturation or solute concentration. Monitoring of time-varying hydrologic processes provides insight into aquifer properties and structure and aquifer responses to natural or induced stresses, such as seasonal fluctuations or fluid injection experiments for active remediation. The U.S. Geological Survey (USGS) Office of Ground Water, Branch of Geophysics, in cooperation with USGS Toxic Substances Hydrology Program, Environmental Protection Agency (USEPA), Department of Defense, the University of Connecticut, and Stanford University researchers, has applied time-lapse geophysics for site characterization and remediation monitoring in a number of studies. Recent and ongoing examples of time-lapse monitoring in fractured-rock aquifers include: 1) application of attenuation-difference, boreholeradar tomography used to monitor a series of sodium chloride tracer injection tests in fractured crystalline rock; 2) application of attenuation- and velocity-difference tomography and radar-reflection data to monitor steam injection in a fractured limestone aquifer; 3) design of an electrical resistivity tomography investigation to monitor the injection of resistive water into brackish water in a fractured limestone aquifer for aquifer storage and recovery (ASR); and 4) combined application of borehole-geophysical logging with long-term discreteinterval monitoring of hydraulic head and water-chemistry in a fractured crystalline-rock aquifer. These investigations demonstrate the application of geophysical methods to provide quantitative information about the subsurface critical for characterizing aquifer structure, flow dynamics, and hydraulic processes.

New Hampshire

Field methods for measurement of ground water redox chemical parameters

An inexpensive, versatile, and portable system is presented, which facilitates rapid field determinations of redox potentials, pH, conductivity, ferrous and total iron, nitrite, specific conductance, dissolved oxygen, and temperature. Accuracy is facilitated by on‐site measurements of most parameters using specially constructed flow‐through cells and, for several analyses, sealed reagent ampoules, which can be broken and developed inside a flowing stream of ground water. Coupled with laboratory analyses of more stable ground water parameters, this system can provide accurate and relatively inexpensive determinations of redox conditions in ground water.

Groundwater Monitoring & Remediation

Hydraulic logging methods - A summary and field demonstration in Conyers, Rockdale County, Georgia

Geophysical surveying techniques provide important information for ground-water investigations (Zohdy and others, 1974; Keys, 1997; Haeni and others, 2001). Subsurface-geophysical methods are used to delineate and characterize hydraulically active zones; the extent of contamination, and contaminant sources; identify geologic features; optimize monitoring well placement; and guide remediation efforts. Borehole-geophysical methods provide information about the physical, chemical, and hydraulic properties of rock, sediments, and fluids in the subsurface and provide important information on subsurface bedrock structures including lithology, rock fabric, location, orientation, and hydraulic properties of fractures (Keys, 1990). Effective use of geophysical data requires that the data be interpreted in the context of known local and regional geology and hydrogeology. In addition, because of the complexity and heterogeneity of crystalline-rock aquifers, a suite of borehole geophysical methods is used to determine the location, extent, and nature of fractures and other structural features in the bedrock aquifer. The geophysical data from each borehole and method are analyzed together to provide an integrated interpretation, thereby reducing the ambiguity that can occur by interpreting each geophysical log individually (Shapiro and others, 1999). Previous work using borehole geophysics to characterize ground-water availability in crystalline rock aquifers includes Chapman and Lane (1996), Mack and others (1998), and Johnson and others (1999). Other investigations that focused on contamination in fractured-rock aquifers used geophysical methods to relate highly transmissive features to structural features in the bedrock (Hansen and Lane, 1995; and Lane and others, 2002).

Georgia

Effects of surface applications of biosolids on soil, crops, ground water, and streambed sediment near Deer Trail, Colorado, 1999-2003

The U.S. Geological Survey, in cooperation with Metro Wastewater Reclamation District and North Kiowa Bijou Groundwater Management District, studied natural geochemical effects and the effects of biosolids applications to the Metro Wastewater Reclamation District properties near Deer Trail, Colorado, during 1999 through 2003 because of public concern about potential contamination of soil, crops, ground water, and surface water from biosolids applications. Parameters analyzed for each monitoring component included arsenic, cadmium, copper, lead, mercury, molybdenum, nickel, selenium, and zinc (the nine trace elements regulated by Colorado for biosolids), gross alpha and gross beta radioactivity, and plutonium, as well as other parameters. Concentrations of the nine regulated trace elements in biosolids were relatively uniform and did not exceed applicable regulatory standards. All plutonium concentrations in biosolids were below the minimum detectable level and were near zero. The most soluble elements in biosolids were arsenic, molybdenum, nickel, phosphorus, and selenium. Elevated concentrations of bismuth, mercury, phosphorus, and silver would be the most likely inorganic biosolids signature to indicate that soil or streambed sediment has been affected by biosolids. Molybdenum and tungsten, and to a lesser degree antimony, cadmium, cobalt, copper, mercury, nickel, phosphorus, and selenium, would be the most likely inorganic 'biosolids signature' to indicate ground water or surface water has been affected by biosolids. Soil data indicate that biosolids have had no measurable effect on the concentration of the constituents monitored. Arsenic concentrations in soil of both Arapahoe and Elbert County monitoring sites (like soil from all parts of Colorado) exceed the Colorado soil remediation objectives and soil cleanup standards, which were determined by back-calculating a soil concentration equivalent to a one-in-a-million cumulative cancer risk. Lead concentrations in soil slightly exceed the U.S. Environmental Protection Agency toxicity-derived ecological soil-screening levels for avian wildlife. Plutonium concentration in the soil was near zero. Wheat-grain data were insufficient to determine any measurable effects from biosolids. Comparison with similar data from other parts of North America where biosolids were not applied indicates similar concentrations. However, the Deer Trail study area had higher nickel concentrations in wheat from both the biosolids-applied fields and the control fields. Plutonium content of the wheat was near zero. Ground-water levels generally declined at most wells during 1999 through 2003. Ground-water quality did not correlate with ground-water levels. Vertical ground-water gradients during 1999 through 2003 indicate that bedrock ground-water resources downgradient from the biosolids-applied areas are not likely to be contaminated by biosolids applications unless the gradients change as a result of pumping. Ground-water quality throughout the study area varied over time at each site and from site to site at the same time, but plutonium concentrations in the ground water always were near zero. Inorganic concentrations at well D6 were relatively high compared to other ground-water sites studied. Ground-water pH and concentrations of fluoride, nitrite, aluminum, arsenic, barium, chromium, cobalt, copper, lead, mercury, nickel, silver, zinc, and plutonium in the ground water of the study area met Colorado standards. Concentrations of chloride, sulfate, nitrate, boron, iron, manganese, and selenium exceeded Colorado ground-water standards at one or more wells. Nitrate concentrations at well D6 significantly (alpha = 0.05) exceeded the Colorado regulatory standard. Concentrations of arsenic, cadmium, chromium, lead, mercury, nickel, and zinc in ground water had no significant (alpha = 0.05) upward trends. During 1999-2003, concentrations of nitrate, copper, molybdenum, and selenium

Scientific Investigations Report

Laboratory comparison of polyethylene and dialysis membrane diffusion samplers

The ability of diffusion samplers constructed from regenerated cellulose dialysis membrane and low density, lay flat polyethylene tubing to collect volatile organic compounds and inorganic ions was compared in a laboratory study. Concentrations of vinyl chloride, cis ‐1, 2‐dichloroethene, bromochloromethane, trichloroethene, bromodichloromethane, and tetrachloroethene collected by both types of diffusion samplers reached equilibrium with the concentrations of these compounds in test solution within three days. Concentrations of bromide and iron collected by the dialysis membrane diffusion samplers reached equilibrium with the concentrations of these compounds in a test solution within three to seven days. No detectable concentrations of bromide or iron were found in polyethylene diffusion samplers even after 21 days. No measurable concentrations of aluminum, arsenic, barium, cadmium, chromium, iron, mercury, manganese, nickel, and lead, or sulfide, were leached out of dialysis membrane samplers over seven days. Compared with using a gas‐tight syringe to sample the diffusion sampler, clipping the bag and pouring the water sample into a sample vial resulted in only a small 6.2% average loss of volatile organic compounds. Dialysis membrane diffusion samplers offer promise for use in sampling ground water for inorganic constituents as well as volatile organic compounds.

Groundwater Monitoring & Remediation

Interpretation of geophysical logs, aquifer tests, and water levels in wells in and near the North Penn Area 7 Superfund site, Upper Gwynedd Township, Montgomery County, Pennsylvania, 2000-02

Ground water in the vicinity of various industrial facilities in Upper Gwynedd Township and Lansdale Borough, Montgomery County, Pa., is contaminated with various volatile organic compounds (VOCs). The 2-square-mile area was placed on the National Priorities List as the North Penn Area 7 Superfund site by the U.S. Environmental Protection Agency (USEPA) in 1989. The U.S. Geological Survey (USGS) conducted geophysical logging, aquifer testing, water-level monitoring, and streamflow measurements in the vicinity of North Penn Area 7 beginning autumn 2000 to assist the USEPA in developing an understanding of the hydrogeologic framework in the area as part of the USEPA Remedial Investigation. The study area is underlain by Triassic and Jurassic-age sandstones, siltstones, and shales of the Lockatong Formation and the Brunswick Group. Regionally, these rocks strike northeast and dip to the northwest. The sequence of rocks form a fractured-sedimentary-rock aquifer that acts as a set of confined to partially confined layered aquifers of differing permeabilities. The aquifers are recharged by precipitation and discharge to streams and wells. The Wissahickon Creek headwaters are less than 1 mile northeast of the study area, and this stream flows southwest to bisect North Penn Area 7. Ground water is pumped in the vicinity of North Penn Area 7 for industrial use and public supply. The USGS collected geophysical logs for 16 wells that ranged in depth from 50 to 623 feet. Aquifer-interval-isolation testing was done in 9 of the 16 wells, for a total of 30 zones tested. A multiple-well aquifer test was conducted by monitoring the response of 14 wells to pumping a 600-ft deep production well in February and March 2002. In addition, water levels were monitored continuously in three wells in the area and streamflow was measured quarterly at two sites on Wissahickon Creek from December 2000 through September 2002. Geophysical logging identified water-bearing zones associated with high-angle fractures and bedding-plane openings throughout the depth of the boreholes. Heatpulse-flowmeter measurements under nonpumping, ambient conditions indicated that borehole flow, where detected, was in the upward direction in three of the eight wells and in the downward direction in three wells. In two wells, both upward and downward flow were measured. Heatpulse-flowmeter measurements under pumping conditions were used to identify the most productive intervals in wells. Correlation of natural-gamma-ray and single-point-resistance logs indicated that bedding in the area probably strikes about 40 degrees northeast and dips from 6 to 7 degrees northwest. Aquifer intervals isolated by inflatable packers in wells were pumped to test productivity and to collect samples to determine chemical quality of water produced from the interval. Interval-isolation testing confirmed the presence of vertical hydraulic gradients indicated by heatpulse-flowmeter measurements. The specific capacities of isolated intervals ranged over two orders of magnitude, from 0.02 to more than 3.6 gallons per minute per foot. Intervals adjacent to isolated pumped intervals showed little response to pumping the isolated zone. The presence of vertical hydraulic gradients and lack of adjacent-interval response to pumping in isolated intervals indicate a limited degree of vertical hydraulic connection between the aquifer intervals tested. Concentrations of most VOC contaminants generally were highest in well-water samples from the shallowest isolated intervals, with some exceptions. Trichloroethylene, cis-1,2-dichloroethylene, and toluene were the most frequently detected VOCs, with maximum concentrations of greater than 340, 680, and greater than 590 micrograms per liter, respectively. Results of the aquifer test with multiple observation wells showed that water levels in 4 of the 14 wells declined in response to pumping. The four wells that responded to pumping are either along str

Scientific Investigations Report

Time-lapse electrical geophysical monitoring of amendment-based biostimulation

Biostimulation is increasingly used to accelerate microbial remediation of recalcitrant groundwater contaminants. Effective application of biostimulation requires successful emplacement of amendment in the contaminant target zone. Verification of remediation performance requires postemplacement assessment and contaminant monitoring. Sampling-based approaches are expensive and provide low-density spatial and temporal information. Time-lapse electrical resistivity tomography (ERT) is an effective geophysical method for determining temporal changes in subsurface electrical conductivity. Because remedial amendments and biostimulation-related biogeochemical processes often change subsurface electrical conductivity, ERT can complement and enhance sampling-based approaches for assessing emplacement and monitoring biostimulation-based remediation. Field studies demonstrating the ability of time-lapse ERT to monitor amendment emplacement and behavior were performed during a biostimulation remediation effort conducted at the Department of Defense Reutilization and Marketing Office (DRMO) Yard, in Brandywine, Maryland, United States. Geochemical fluid sampling was used to calibrate a petrophysical relation in order to predict groundwater indicators of amendment distribution. The petrophysical relations were field validated by comparing predictions to sequestered fluid sample results, thus demonstrating the potential of electrical geophysics for quantitative assessment of amendment-related geochemical properties. Crosshole radar zero-offset profile and borehole geophysical logging were also performed to augment the data set and validate interpretation. In addition to delineating amendment transport in the first 10 months after emplacement, the time-lapse ERT results show later changes in bulk electrical properties interpreted as mineral precipitation. Results support the use of more cost-effective surface-based ERT in conjunction with limited field sampling to improve spatial and temporal monitoring of amendment emplacement and remediation performance.

Maryland

Evaluation of ground-penetrating radar to detect free-phase hydrocarbons in fractured rocks: Results of numerical modeling and physical experiments

The suitability of common-offset ground-penetrating radar (GPR) to detect free-phase hydrocarbons in bedrock fractures was evaluated using numerical modeling and physical experiments. The results of one- and two-dimensional numerical modeling at 100 megahertz indicate that GPR reflection amplitudes are relatively insensitive to fracture apertures ranging from 1 to 4 mm. The numerical modeling and physical experiments indicate that differences in the fluids that fill fractures significantly affect the amplitude and the polarity of electromagnetic waves reflected by subhorizontal fractures. Air-filled and hydrocarbon-filled fractures generate low-amplitude reflections that are in-phase with the transmitted pulse. Water-filled fractures create reflections with greater amplitude and opposite polarity than those reflections created by air-filled or hydrocarbon-filled fractures. The results from the numerical modeling and physical experiments demonstrate it is possible to distinguish water-filled fracture reflections from air- or hydrocarbon-filled fracture reflections, nevertheless subsurface heterogeneity, antenna coupling changes, and other sources of noise will likely make it difficult to observe these changes in GPR field data. This indicates that the routine application of common-offset GPR reflection methods for detection of hydrocarbon-filled fractures will be problematic. Ideal cases will require appropriately processed, high-quality GPR data, ground-truth information, and detailed knowledge of subsurface physical properties. Conversely, the sensitivity of GPR methods to changes in subsurface physical properties as demonstrated by the numerical and experimental results suggests the potential of using GPR methods as a monitoring tool. GPR methods may be suited for monitoring pumping and tracer tests, changes in site hydrologic conditions, and remediation activities.The suitability of common-offset ground-penetrating radar (GPR) to detect free-phase hydrocarbons in bedrock fractures was evaluated using numerical modeling and physical experiments. The results of one- and two-dimensional numerical modeling at 100 megahertz indicate that GPR reflection amplitudes are relatively insensitive to fracture apertures ranging from 1 to 4 mm. The numerical modeling and physical experiments indicate that differences in the fluids that fill fractures significantly affect the amplitude and the polarity of electromagnetic waves reflected by subhorizontal fractures. Air-filled and hydrocarbon-filled fractures generate low-amplitude reflections that are in-phase with the transmitted pulse. Water-filled fractures create reflections with greater amplitude and opposite polarity than those reflections created by air-filled or hydrocarbon-filled fractures. The results from the numerical modeling and physical experiments demonstrate it is possible to distinguish water-filled fracture reflections from air- or hydrocarbon-filled fracture reflections, nevertheless subsurface heterogeneity, antenna coupling changes, and other sources of noise will likely make it difficult to observe these changes in GPR field data. This indicates that the routine application of common-offset GPR reflection methods for detection of hydrocarbon-filled fractures will be problematic. Ideal cases will require appropriately processed, high-quality GPR data, ground-truth information, and detailed knowledge of subsurface physical properties. Conversely, the sensitivity of GPR methods to changes in subsurface physical properties as demonstrated by the numerical and experimental results suggests the potential of using GPR methods as a monitoring tool. GPR methods may be suited for monitoring pumping and tracer tests, changes in site hydrologic conditions, and remediation activities.

Ground Water

Geophysical Logs, Aquifer Tests, and Water Levels in Wells in and Near the North Penn Area 7 Superfund Site, Upper Gwynedd Township, Montgomery County, Pennsylvania, 2002-2006

Ground water in the vicinity of several industrial facilities in Upper Gwynedd Township and Lansdale Borough, Montgomery County, Pa., is contaminated with several volatile organic compounds (VOCs). The 2-square-mile area was placed on the National Priorities List as the North Penn Area 7 Superfund Site by the U.S. Environmental Protection Agency (USEPA) in 1989. The U.S. Geological Survey (USGS) conducted geophysical logging, aquifer testing, water-level monitoring, and streamflow measurements in the vicinity of North Penn Area 7 from October 2002 through December 2006. This followed work that began in 2000 to assist the USEPA in developing an understanding of the hydrogeologic framework in the area as part of the USEPA Remedial Investigation. The study area is underlain by Triassic- and Jurassic-age sandstones, siltstones, and shales of the Lockatong Formation and the Brunswick Group. Regionally, these rocks strike northeast and dip to the northwest. The sequence of rocks form fractured-rock aquifers that act as a set of confined to semi-confined layered aquifers of differing permeabilities. The aquifers are recharged by precipitation and discharge to streams and wells. The Wissahickon Creek headwaters are less than 1 mile northeast of the study area. This stream flows southwest approximately parallel to strike and bisects North Penn Area 7. Ground water is pumped in the vicinity of North Penn Area 7 for industrial use and public supply. The USGS collected geophysical logs for 42 wells that ranged in depth from 40 to 477 ft. Aquifer-interval-isolation testing was done in 17 of the 42 wells, for a total of 122 zones tested. A multiple-well aquifer test was conducted by monitoring the response of 14 wells to pumping and shutdown of a 600-ft deep production well in November-December 2004. In addition, water levels were monitored continuously in four wells in the area from October 2002 through September 2006, and streamflow was measured quarterly at two sites on Wissahickon Creek from December 2002 through September 2005. Geophysical logging identified water-bearing zones associated with high-angle fractures and bedding-plane openings throughout the depth of the boreholes. Heatpulse-flowmeter measurements under non-pumping, ambient conditions in 16 wells greater than 200 ft in depth indicated that borehole flow, where detected, was only upward in 2 wells and only downward in 5 wells. In nine wells, both upward and downward flow were measured. Geologic structure and pumping in the area affect the spatial distribution of vertical gradients. Heatpulse-flowmeter measurements under pumping conditions were used to identify the most productive intervals in wells. Correlation of natural-gamma-ray logs indicated bedding in the area probably strikes about 45 to 65 degrees northeast and dips about 9 degrees northwest. Aquifer intervals isolated by inflatable packers in 17 wells were pumped to test productivity of water-bearing zones and to collect samples to determine chemical quality of water produced from the interval. Interval-isolation testing confirmed the vertical hydraulic gradients indicated by heatpulse-flowmeter measurements. The specific capacities of the 122 isolated intervals ranged over about three orders of magnitude, from 0.01 to 10.6 gallons per minute per foot, corresponding to calculated transmissivities of 1.2 to 2,290 feet squared per day. Intervals adjacent to isolated pumped intervals commonly showed little response to pumping of the isolated zone. The presence of vertical hydraulic gradients and lack of adjacent-interval response to pumping in isolated intervals indicate a limited degree of vertical hydraulic connection between the aquifer sections tested. Differences were apparent in inorganic water quality of water from isolated intervals, including pH, specific conductance, and dissolved oxygen. Concentrations of most VOC contaminants in most wells with predominantly upward vertical gradients were g

Scientific Investigations Report

Methodology for applying monitored natural attenuation to petroleum hydrocarbon-contaminated ground-water systems with examples from South Carolina

Natural attenuation processes such as dispersion, advection, and biogradation serve to decrease concentrations of disssolved contaminants as they are transported in all ground-water systems. However, the efficiency of these natural attenuation processes and the degree to which they help attain remediation goals, varies considerably from site to site. This report provides a methodology for quantifying various natural attenuation mechanisms. This methodology incorporates information on (1) concentrations of contaminants in space and/or time; (2) ambient reduction/oxidation (redox) conditions; (3) rates and directions of ground-water flow; (4) rates of contaminant biodegradation; and (5) demographic considerations, such as the presence of nearby receptor exposure points or property boundaries. This document outlines the hydrologic, geochemical, and biologic data needed to assess the efficiency of natural attenuation, provides a screening tool for making preliminary assessments, and provides examples of how to determine when natural attenuation can be a useful component of site remediation at leaking underground storage tank sites. At a site in the Piedmont Physiographic Province (Laurens, South Carolina), hydrologic and water-chemistry data indicate that the natural attenuation capacity for benzene is approximately 5 percent per foot of flowpath. As a result, benzene concentrations would decrease from about 28,000 micrograms per liter in ground water at the source area to less than 5 micrograms per liter 200 feet downgradient and prior to discharging to a stream. Because of this rapid attenuation, contaminants do not presently impact the stream downgradient of the site. In contrast, at a site in the coastal Plain Physiographic Province (Charleston, South Carolina), hydrologic and water-chemistry data indicate that, even thought the site has a substantial natural attenuation capacity, it may not be sufficient to fully protect a nearby point of ground-water discharge. These two sites illustrate how the efficiency of natural attenuation processes acting on petroleum hydrocarbons can be systematically evaluated using hydrologic, geochemical, and microbiologic methods. These methods, in turn, can be used to assess the role that the natural attenuation of petroleum hydrocarbons can play in achieving overall site remediation.

South Carolina

Pharmaceuticals and other organic wastewater contaminants within a leachate plume downgradient of a municipal landfill

Ground water samples collected from the Norman Landfill research site in central Oklahoma were analyzed as part of the U.S. Geological Survey (USGS) Toxic Substances Hydrology Program's national reconnaissance of pharmaceuticals and other organic waste water contaminants (OWCs) in ground water. Five sites, four of which are located downgradient of the landfill, were sampled in 2000 and analyzed for 76 OWCs using four research methods developed by the USGS. OWCs were detected in water samples from all of the sites sampled, with 22 of the 76 OWCs being detected at least once. Cholesterol (a plant and animal steroid), was detected at all five sites and was the only compound detected in a well upgradient of the landfill. N,Ndiethyltoluamide (DEET used in insect repellent) and tri(2-chloroethyl) phosphate (fire-retardant) were detected in water samples from all four sites located within the landfill-derived leachate plume. The sites closest to the landfill had more detections and greater concentrations of each of the detected compounds than sites located farther away. Detection of multiple OWCs occurred in the four sites located within the leachate plume, with a minimum of four and a maximum of 17 OWCs detected. Because the landfill was established in the 1920s and closed in 1985, many compounds detected in the leachate plume were likely disposed of decades ago. These results indicate the potential for long-term persistence and transport of some OWCs in ground water.

Oklahoma

Hydrologic, sediment, and biological data associated with irrigation drainage in the middle Green River basin, Utah and Colorado, water years 1991-2000

Hydrologic, sediment, and biological data were collected in the middle Green River basin in eastern Utah from 1991 to 2000 in an effort to monitor the effects of irrigation drainage on wetland areas and streams, aid in the development of remediation plans, and evaluate the effectiveness of selenium remediation efforts at Stewart Lake Waterfowl Management Area (WMA). Data consist primarily of selenium concentrations in surface water, ground water, bottom sediment, and biological samples. Supporting hydrologic data include field measurements of temperature, pH, specific conductance, water levels in wells, and discharge at surface-water sites. Selected water samples also were analyzed for major ions, trace elements, nutrients, and gross alpha and beta radiation. The concentration of selected selenium species is reported for several bottom-sediment samples from Stewart Lake WMA and the concentration of total selenium in suspended-sediment samples from the area are included. Well logs for six wells installed at Stewart Lake WMA are presented along with trace-element data for several biological samples collected at selected sites throughout the middle Green River basin.

Colorado, Utah, Wyoming

Technical protocol for evaluating natural attenuation of chlorinated solvents in ground water

This Protocol is designed to evaluate the fate in ground water of chlorinated aliphatic hydrocarbons and/or fuel hydrocarbons. Documentation of natural attenuation requires detailed site characterization. The data collected under this protocol can be used to compare the relative effectiveness of other remedial options. and natural attenuation. This protocol should be used to evaluate whether monitored natural attenuation by itself or in conjunction with other remedial technologies is sufficient to achieve site-specific remedial objectives. Understanding the contaminant flow field in the subsurface is essential for a technically justified evaluation of a monitored natural attenuation remedial option; therefore, use of this protocol is not appropriate for evaluating monitored natural attenuation at sites where the contaminant flow field cannot be determined with an acceptable degree of certainty (e.g., complex fractured bedrock, karst, aquifers.)

Report

Fate of MTBE relative to benzene in a gasoline-contaminated aquifer (1993-98):

Methyl tert -butyl ether (MTBE) and benzene have been measured since 1993 in a shallow, sandy aquifer contaminated by a mid-1980s release of gasoline containing fuel oxygenates. In wells downgradient of the release area, MTBK was detected before benzene, reflecting a chromatographic-like separation of these compounds in the direction of ground water flow. Higher concentrations of MTBE and benzene were measured in the deeper sampling ports of multilevel sampling wells located near the release area, and also up to 10 feet (3 m) below the water table surface in nested wells located farther from the release area. This distribution of higher concentrations at depth is caused by recharge events that deflect originally horizontal ground water flowlines. In the laboratory, microcosms containing aquifer material incubated with uniformly labeled 14 C-MTBE under aerobic and anaerobic. Fe(III)-reducing conditions indicated a low but measurable biodegradation potential (<3% 14 C-MTBW as 14 CO 2 ) after a seven-month incubation period, Tert -butyl alcohol (TBA), a proposed microbial-MTBE transformation intermediate, was detected in MTBE-contaminated wells, but TBA was also measured in unsaturated release area sediments. This suggests that TBA may have been present in the original fuel spilled and does not necessarily reflect microbial degradation of MTBE. Combined, these data suggest that milligram per liter to microgram per liter decreases in MTBE concentrations relative to benzene are caused by the natural attenuation processes of dilution and dispersion with less-contaminated ground water in the direction of flow rather than biodegradation at this point source gasoline release site.

Groundwater Monitoring & Remediation

Detection of contaminant plumes by bore­ hole geophysical logging

Two borehole geophysical methods—electromagnetic induction and natural gamma radiation logs—were used to vertically delineate landfill leachate plumes in a glacial aquifer. Geophysical logs of monitoring wells near two land-fills in a glacial aquifer in west-central Vermont show that borehole geophysical methods can aid in interpretation of geologic logs and placement of monitoring well screens to sample landfill leachate plumes. Zones of high electrical conductance were delineated from the electromagnetic log in wells near two landfills. Some of these zones were found to correlate with silt and clay units on the basis of drilling and gamma logs. Monitoring wells were screened specifically in zones of high electrical conductivity that did not correlate to a silt or clay unit. Zones of high electrical conductivity that did not correlate to a silt or clay unit were caused by the presence of ground water with a high specific conductance, generally from 1000 to 2370 μS/cm (microsiemens per centimeter at 25 degrees Celsius). Ambient ground water in the study area has a specific conductance of approximately 200 to 400 μS/cm. Landfill leachate plumes were found to be approximately 5 to 20 feet thick and to be near the water table surface.

Groundwater Monitoring & Remediation