Geology Reports⌕ Search

SEARCH · Geology Reports

Results for “Atmosphere”

Search indexed USGS publications on groundwater, aquifers, geologic maps, mineral resources and earthquakes. Explore source records by subject and place.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20Linked to original sources

External Quality Assurance Programs Managed by the U.S. Geological Survey in Support of the National Atmospheric Deposition Program/Mercury Deposition Network

The U.S. Geological Survey (USGS) Branch of Quality Systems operates external quality assurance programs for the National Atmospheric Deposition Program/Mercury Deposition Network (NADP/MDN). Beginning in 2004, three programs have been implemented: the system blank program, the interlaboratory comparison program, and the blind audit program. Each program was designed to measure error contributed by specific components in the data-collection process. The system blank program assesses contamination that may result from sampling equipment, field exposure, and routine handling and processing of the wet-deposition samples. The interlaboratory comparison program evaluates bias and precision of analytical results produced by the Mercury Analytical Laboratory (HAL) for the NADP/MDN, operated by Frontier GeoSciences, Inc. The HAL's performance is compared with the performance of five other laboratories. The blind audit program assesses bias and variability of MDN data produced by the HAL using solutions disguised as environmental samples to ascertain true laboratory performance. This report documents the implementation of quality assurance procedures for the NADP/MDN and the operating procedures for each of the external quality assurance programs conducted by the USGS. The USGS quality assurance information provides a measure of confidence to NADP/MDN data users that measurement variability is distinguished from environmental signals.

Open-File Report↗

Historical Zinc Smelting in New Jersey, Pennsylvania, Virginia, West Virginia, and Washington, D.C., with Estimates of Atmospheric Zinc Emissions and Other Materials

The metallurgical industry can be broadly divided into metal production from feedstock consisting of primary and secondary sources. Primary production refers to the extraction of metal derived from ores and concentrates. Secondary production refers to the recovery of metal from materials such as alloys, electric arc furnace dust, ingots, and scrap. The foci of this study are the histories of selected pyrometallurgical plants that treated mostly primary zinc feedstock and the atmospheric emissions, primarily zinc, generated by those plants during the course of producing zinc and zinc oxide in New Jersey, Pennsylvania, Virginia, West Virginia, and Washington, D.C.

Open-File Report↗

Four studies on effects of environmental factors on the quality of National Atmospheric Deposition Program measurements

Selected aspects of National Atmospheric Deposition Program / National Trends Network (NADP/NTN) protocols are evaluated in four studies. Meteorological conditions have minor impacts on the error in NADP/NTN sampling. Efficiency of frozen precipitation sample collection is lower than for liquid precipitation samples. Variability of NTN measurements is higher for relatively low-intensity deposition of frozen precipitation than for higher-intensity deposition of liquid precipitation. Urbanization of the landscape surrounding NADP/NTN sites is not affecting trends in wet-deposition chemistry data to a measureable degree. Five NADP siting criteria intended to preserve wet-deposition sample integrity have varying degrees of effectiveness. NADP siting criteria for objects within the 90 degrees cones and trees within the 120 degrees cones projected from the collector bucket to sky are important for protecting sample integrity. Tall vegetation, fences, and other objects located within 5 meters of the collectors are related to the frequency of visible sample contamination, indicating the importance of these factors in NADP siting criteria.

Open-File Report↗

Effects of equipment performance on data quality from the National Atmospheric Deposition Program/National Trends Network and the Mercury Deposition Network

The U.S. Geological Survey Branch of Quality Systems operates the Precipitation Chemistry Quality Assurance project (PCQA) to provide independent, external quality-assurance for the National Atmospheric Deposition Program (NADP). NADP is composed of five monitoring networks that measure the chemical composition of precipitation and ambient air. PCQA and the NADP Program Office completed five short-term studies to investigate the effects of equipment performance with respect to the National Trends Network (NTN) and Mercury Deposition Network (MDN) data quality: sample evaporation from NTN collectors; sample volume and mercury loss from MDN collectors; mercury adsorption to MDN collector glassware, grid-type precipitation sensors for precipitation collectors, and the effects of an NTN collector wind shield on sample catch efficiency. Sample-volume evaporation from an NTN Aerochem Metrics (ACM) collector ranged between 1.1–33 percent with a median of 4.7 percent. The results suggest that weekly NTN sample evaporation is small relative to sample volume. MDN sample evaporation occurs predominantly in western and southern regions of the United States (U.S.) and more frequently with modified ACM collectors than with N-CON Systems Inc. collectors due to differences in airflow through the collectors. Variations in mercury concentrations, measured to be as high as 47.5 percent per week with a median of 5 percent, are associated with MDN sample-volume loss. Small amounts of mercury are also lost from MDN samples by adsorption to collector glassware irrespective of collector type. MDN 11-grid sensors were found to open collectors sooner, keep them open longer, and cause fewer lid cycles than NTN 7-grid sensors. Wind shielding an NTN ACM collector resulted in collection of larger quantities of precipitation while also preserving sample integrity.

Open-File Report↗

User’s guide and reference to Ash3d—A three-dimensional model for Eulerian atmospheric tephra transport and deposition

Ash3d is a three-dimensional Eulerian atmospheric model for tephra transport, dispersal, and deposition to study and forecast hazards of volcanic ash clouds and tephra fall. In this report, we explain how to set up simulations using a web interface, and how to view and interpret model output. We also summarize the architecture of the model and some of its properties.

Open-File Report↗

External quality-assurance results for the national atmospheric deposition program/national trends network, 2000-2001

Five external quality-assurance programs were operated by the U.S. Geological Survey for the National Atmospheric Deposition Program/National Trends Network (NADP/NTN) from 2000 through 2001 (study period): the intersite-comparison program, the blind-audit program, the field-audit program, the interlaboratory-comparison program, and the collocated-sampler program. Each program is designed to measure specific components of the total error inherent in NADP/NTN wet-deposition measurements. The intersite-comparison program assesses the variability and bias of pH and specific-conductance determinations made by NADP/NTN site operators with respect to accuracy goals. The accuracy goals are statistically based using the median of all of the measurements obtained for each of four intersite-comparison studies. The percentage of site operators responding on time that met the pH accuracy goals ranged from 84.2 to 90.5 percent. In these same four intersite-comparison studies, 88.9 to 99.0 percent of the site operators met the accuracy goals for specific conductance. The blind-audit program evaluates the effects of routine sample handling, processing, and shipping on the chemistry of weekly precipitation samples. The blind-audit data for the study period indicate that sample handling introduced a small amount of sulfate contamination and slight changes to hydrogen-ion content of the precipitation samples. The magnitudes of the paired differences are not environmentally significant to NADP/NTN data users. The field-audit program (also known as the 'field-blank program') was designed to measure the effects of field exposure, handling, and processing on the chemistry of NADP/NTN precipitation samples. The results indicate potential low-level contamination of NADP/NTN samples with calcium, ammonium, chloride, and nitrate. Less sodium contamination was detected by the field-audit data than in previous years. Statistical analysis of the paired differences shows that contaminant ions are entrained into the solutions from the field-exposed buckets, but the positive bias that results from the minor amount of contamination appears to affect the analytical results by less than 6 percent. An interlaboratory-comparison program is used to estimate the analytical variability and bias of participating laboratories, especially the NADP Central Analytical Laboratory (CAL). Statistical comparison of the analytical results of participating laboratories implies that analytical data from the various monitoring networks can be compared. Bias was identified in the CAL data for ammonium, chloride, nitrate, sulfate, hydrogen-ion, and specific-conductance measurements, but the absolute value of the bias was less than analytical minimum reporting limits for all constituents except ammonium and sulfate. Control charts show brief time periods when the CAL's analytical precision for sodium, ammonium, and chloride was not within the control limits. Data for the analysis of ultrapure deionized-water samples indicated that the laboratories are maintaining good control of laboratory contamination. Estimated analytical precision among the laboratories indicates that the magnitudes of chemical-analysis errors are not environmentally significant to NADP data users. Overall precision of the precipitation-monitoring system used by the NADP/NTN was estimated by evaluation of samples from collocated monitoring sites at CA99, CO08, and NH02. Precision defined by the median of the absolute percent difference (MAE) was estimated to be approximately 10 percent or less for calcium, magnesium, sodium, chloride, nitrate, sulfate, specific conductance, and sample volume. The MAE values for ammonium and hydrogen-ion concentrations were estimated to be less than 10 percent for CA99 and NH02 but nearly 20 percent for ammonium concentration and about 17 percent for hydrogen-ion concentration for CO08. As in past years, the variability in the collocated-site data for sam

Scientific Investigations Report↗

External quality-assurance results for the National Atmospheric Deposition Program/National Trends Network, 2002-03

Six external quality-assurance programs were operated by the U.S. Geological Survey (USGS) External Quality-Assurance (QA) Project for the National Atmospheric Deposition Program/National Trends Network (NADP/NTN) from 2002 through 2003. Each program measured specific components of the overall error inherent in NADP/NTN wet-deposition measurements. The intersite-comparison program assessed the variability and bias of pH and specific conductance determinations made by NADP/NTN site operators twice per year with respect to accuracy goals. The percentage of site operators that met the pH accuracy goals decreased from 92.0 percent in spring 2002 to 86.3 percent in spring 2003. In these same four intersite-comparison studies, the percentage of site operators that met the accuracy goals for specific conductance ranged from 94.4 to 97.5 percent. The blind-audit program and the sample-handling evaluation (SHE) program evaluated the effects of routine sample handling, processing, and shipping on the chemistry of weekly NADP/NTN samples. The blind-audit program data indicated that the variability introduced by sample handling might be environmentally significant to data users for sodium, potassium, chloride, and hydrogen ion concentrations during 2002. In 2003, the blind-audit program was modified and replaced by the SHE program. The SHE program was designed to control the effects of laboratory-analysis variability. The 2003 SHE data had less overall variability than the 2002 blind-audit data. The SHE data indicated that sample handling buffers the pH of the precipitation samples and, in turn, results in slightly lower conductivity. Otherwise, the SHE data provided error estimates that were not environmentally significant to data users. The field-audit program was designed to evaluate the effects of onsite exposure, sample handling, and shipping on the chemistry of NADP/NTN precipitation samples. Field-audit results indicated that exposure of NADP/NTN wet-deposition samples to onsite conditions tended to neutralize the acidity of the samples by less than 1.0 microequivalent per liter. Onsite exposure of the sampling bucket appeared to slightly increase the concentration of most of the analytes but not to an extent that was environmentally significant to NADP data users. An interlaboratory-comparison program was used to estimate the analytical variability and bias of the NADP Central Analytical Laboratory (CAL) during 2002-03. Bias was identified in the CAL data for calcium, magnesium, sodium, potassium, ammonium, chloride, nitrate, sulfate, hydrogen ion, and specific conductance, but the absolute value of the bias was less than analytical minimum detection limits for all constituents except magnesium, nitrate, sulfate, and specific conductance. Control charts showed that CAL results were within statistical control approximately 90 percent of the time. Data for the analysis of ultrapure deionized-water samples indicated that CAL did not have problems with laboratory contamination. During 2002-03, the overall variability of data from the NADP/NTN precipitation-monitoring system was estimated using data from three collocated monitoring sites. Measurement differences of constituent concentration and deposition for paired samples from the collocated samplers were evaluated to compute error terms. The medians of the absolute percentage errors (MAEs) for the paired samples generally were larger for cations (approximately 8 to 50 percent) than for anions (approximately 3 to 33 percent). MAEs were approximately 16 to 30 percent for hydrogen-ion concentration, less than 10 percent for specific conductance, less than 5 percent for sample volume, and less than 8 percent for precipitation depth. The variability attributed to each component of the sample-collection and analysis processes, as estimated by USGS quality-assurance programs, varied among analytes. Laboratory analysis variability accounted for approximately 2 percent of the

Scientific Investigations Report↗

External quality-assurance results for the National Atmospheric Deposition Program / National Trends Network and Mercury Deposition Network, 2004

The U.S. Geological Survey (USGS) used five programs to provide external quality-assurance monitoring for the National Atmospheric Deposition Program/National Trends Network (NADP/NTN) and two programs to provide external quality-assurance monitoring for the NADP/Mercury Deposition Network (NADP/MDN) during 2004. An intersite-comparison program was used to estimate accuracy and precision of field-measured pH and specific-conductance. The variability and bias of NADP/NTN data attributed to field exposure, sample handling and shipping, and laboratory chemical analysis were estimated using the sample-handling evaluation (SHE), field-audit, and interlaboratory-comparison programs. Overall variability of NADP/NTN data was estimated using a collocated-sampler program. Variability and bias of NADP/MDN data attributed to field exposure, sample handling and shipping, and laboratory chemical analysis were estimated using a system-blank program and an interlaboratory-comparison program. In two intersite-comparison studies, approximately 89 percent of NADP/NTN site operators met the pH measurement accuracy goals, and 94.7 to 97.1 percent of NADP/NTN site operators met the accuracy goals for specific conductance. Field chemistry measurements were discontinued by NADP at the end of 2004. As a result, the USGS intersite-comparison program also was discontinued at the end of 2004. Variability and bias in NADP/NTN data due to sample handling and shipping were estimated from paired-sample concentration differences and specific conductance differences obtained for the SHE program. Median absolute errors (MAEs) equal to less than 3 percent were indicated for all measured analytes except potassium and hydrogen ion. Positive bias was indicated for most of the measured analytes except for calcium, hydrogen ion and specific conductance. Negative bias for hydrogen ion and specific conductance indicated loss of hydrogen ion and decreased specific conductance from contact of the sample with the collector bucket. Field-audit results for 2004 indicate dissolved analyte loss in more than one-half of NADP/NTN wet-deposition samples for all analytes except chloride. Concentrations of contaminants also were estimated from field-audit data. On the basis of 2004 field-audit results, at least 25 percent of the 2004 NADP/NTN concentrations for sodium, potassium, and chloride were lower than the maximum sodium, potassium, and chloride contamination likely to be found in 90 percent of the samples with 90-percent confidence. Variability and bias in NADP/NTN data attributed to chemical analysis by the NADP Central Analytical Laboratory (CAL) were comparable to the variability and bias estimated for other laboratories participating in the interlaboratory-comparison program for all analytes. Variability in NADP/NTN ammonium data evident in 2002-03 was reduced substantially during 2004. Sulfate, hydrogen-ion, and specific conductance data reported by CAL during 2004 were positively biased. A significant (a = 0.05) bias was identified for CAL sodium, potassium, ammonium, and nitrate data, but the absolute values of the median differences for these analytes were less than the method detection limits. No detections were reported for CAL analyses of deionized-water samples, indicating that contamination was not a problem for CAL. Control charts show that CAL data were within statistical control during at least 90 percent of 2004. Most 2004 CAL interlaboratory-comparison results for synthetic wet-deposition solutions were within ?10 percent of the most probable values (MPVs) for solution concentrations except for chloride, nitrate, sulfate, and specific conductance results from one sample in November and one specific conductance result in December. Overall variability of NADP/NTN wet-deposition measurements was estimated during water year 2004 by the median absolute errors for weekly wet-deposition sample concentrations and precipitation measurements for tw

Scientific Investigations Report↗

External quality-assurance project report for the National Atmospheric Deposition Program/National Trends Network and Mercury Deposition Network, 2009-2010

The U.S. Geological Survey operated six distinct programs to provide external quality-assurance monitoring for the National Atmospheric Deposition Program/National Trends Network (NTN) and Mercury Deposition Network (MDN) during 2009–2010. The field-audit program assessed the effects of onsite exposure, sample handling, and shipping on the chemistry of NTN samples; a system-blank program assessed the same effects for MDN. Two interlaboratory-comparison programs assessed the bias and variability of the chemical analysis data from the Central Analytical Laboratory (CAL) and Mercury (Hg) Analytical Laboratory (HAL). The blind-audit program was also implemented for the MDN to evaluate analytical bias in total Hg concentration data produced by the HAL. The co-located-sampler program was used to identify and quantify potential shifts in NADP data resulting from replacement of original network instrumentation with new electronic recording rain gages (E-gages) and precipitation collectors that use optical sensors. The results indicate that NADP data continue to be of sufficient quality for the analysis of spatial distributions and time trends of chemical constituents in wet deposition across the United States. Results also suggest that retrofit of the NADP networks with the new precipitation collectors could cause –8 to +14 percent shifts in NADP annual precipitation-weighted mean concentrations and total deposition values for ammonium, nitrate, sulfate, and hydrogen ion, and larger shifts (+13 to +74 percent) for calcium, magnesium, sodium, potassium, and chloride. The prototype N-CON Systems bucket collector is more efficient in the catch of precipitation in winter than Aerochem Metrics Model 301 collector, especially for light snowfall.

Scientific Investigations Report↗

External quality assurance project report for the National Atmospheric Deposition Program’s National Trends Network and Mercury Deposition Network, 2017–18

The U.S. Geological Survey (USGS) Precipitation Chemistry Quality Assurance project (PCQA) operated five distinct programs to provide external quality-assurance monitoring for the National Atmospheric Deposition Program’s (NADP) National Trends Network and Mercury Deposition Network during 2017–18. The National Trends Network programs included (1) a field audit program to evaluate sample contamination and stability, (2) an interlaboratory comparison program to evaluate analytical laboratory performance, and (3) a colocated sampler program to evaluate variability attributed to automated precipitation samplers. The Mercury Deposition Network programs include the (4) system blank program and (5) an interlaboratory comparison program. The results indicate consistently low levels of sample contamination, generally strong analytical laboratory performance, and low overall variability in concentration data imparted by field equipment. The NADP operations moved from its 40-year home at the Illinois State Water Survey to the Wisconsin State Laboratory of Hygiene in June 2018. The PCQA programs were modified and (or) temporarily curtailed during the transition in 2018. Bias and variability of sample analysis results were evaluated for the two Central Analytical Laboratories, and ongoing monitoring will be helpful to differentiate true environmental signals from the effects of changing laboratory conditions and performance. Results of quality assurance sample analyses are provided to document that NADP data continue to be of sufficient quality for the analysis of spatial distributions and time trends for chemical constituents in wet deposition.

Scientific Investigations Report↗

External quality-assurance project report for the National Atmospheric Deposition Program’s National Trends Network and Mercury Deposition Network, 2019–20

The U.S. Geological Survey Precipitation Chemistry Quality Assurance project (PCQA) operated four distinct programs to provide external quality-assurance monitoring for the National Atmospheric Deposition Program’s (NADP) National Trends Network (NTN) and Mercury Deposition Network (MDN) during 2019–20. The NTN programs included (1) a field audit program to evaluate sample contamination and stability, and (2) an interlaboratory comparison program to evaluate analytical laboratory performance. The MDN programs included the (3) system blank program to evaluate sample contamination and stability, and (4) an interlaboratory comparison program. The results indicated increased levels of sample contamination compared to previous years for NTN samples and decreased contamination in MDN samples. Strong analytical laboratory performance with low overall variability and bias in concentration data were indicated for the NTN’s Central Analytical Laboratory. A positive bias in the hydrogen ion concentrations in NTN samples during 2019 was eliminated by correction of a pH calibration protocol during 2020. The MDN’s Mercury Analytical Laboratory performance declined in 2020 compared to 2019 as indicated by increased variability in analytical results and a negative bias of approximately -1 nanogram per liter in the concentrations of total mercury. Slight perturbations in contamination levels in NTN samples and in analytical performance for MDN are considered small. The PCQA results indicate that NADP data continue to be of sufficient quality for applications in independent research and NADP data products, including spatial interpolations and time trends for chemical constituents in wet deposition. Small shifts in data quality indicated by the 2019–20 PCQA results are intended to be used for interpretation of the NADP data products.

Scientific Investigations Report↗

External quality-assurance project report for the National Atmospheric Deposition Program National Trends Network and Mercury Deposition Network, 2021–22

The U.S. Geological Survey Precipitation Chemistry Quality Assurance project (PCQA) operated five distinct programs to provide external quality-assurance monitoring for the National Atmospheric Deposition Program (NADP) National Trends Network (NTN) and Mercury Deposition Network (MDN) during 2021–22. The NTN programs included (1) a field audit program to evaluate sample contamination and stability, (2) an interlaboratory-comparison program to evaluate analytical laboratory performance, and (3) a colocated sampler program to estimate overall variability of NTN wet-deposition measurements, and the MDN programs included the (4) system blank program to evaluate sample contamination and stability and (5) an interlaboratory-comparison program. The results indicated increased levels of sample contamination compared to previous years for NTN samples and decreased contamination in MDN samples. Strong analytical laboratory performance with low overall variability and bias in concentration data was indicated for the NTN Central Analytical Laboratory. Slight perturbations in contamination levels in NTN samples and in analytical performance for MDN are considered inconsequential. The colocated sampler program results indicated overall variability in NTN data to range from 0 to 30.3 percent for cations, 1.6 to 11.4 percent for ammonium, 0.8 to 20.2 percent for anions, 10.3 to 17.2 percent for hydrogen-ion concentration, and 1.5 to 12.2 percent for specific conductance. The PCQA results indicate that NADP data continue to be of sufficient quality for applications in independent research and NADP data products, including spatial interpolations and time trends for chemical constituents in wet deposition. Small shifts in data quality indicated by the 2021–22 PCQA results are included to be used for interpretation of the NADP data products.

Scientific Investigations Report↗

External quality-assurance results for the National Atmospheric Deposition Program/National Trends Network, 1997-99

Five external quality-assurance programs were operated by the U.S. Geological Survey for the National Atmospheric Deposition Program/ National Trends Network (NADP/NTN) during 1997 through 1999: the intersite-comparison program, the blind-audit program, the field- audit program, the interlaboratory-comparison program, and the collocated-sampler program. The intersite-comparison program assesses the accuracy of pH and specific-conductance determinations made by NADP/NTN site operators. In two 1997 intersite-comparison studies, 83.7 and 85.8 percent of the pH determinations met the NADP/NTN accuracy goals, whereas 97.3 and 92.4 percent of the specific-conductance determinations met the NADP/NTN accuracy goals. The percentage of pH and specific-conductance determinations that met the accuracy goals in 1998 were, for the most part, higher than in 1997. In two 1998 studies, 90.9 and 90.3 percent of the pH determinations met the accuracy goals compared to 94.7 and 96.0 percent of the specific- conductance measurements meeting the accuracy goals. In one 1999 intersite-comparison study, 89.5 percent and 99.4 percent of pH and specific- conductance determinations, respectively, met the NADP/NTN accuracy goals. The blind-audit program evaluates the effects of routine sample handling, processing, and shipping on the analytical bias and precision of weekly precipitation samples. A portion of the blind-audit sample subject to the normal onsite handling and processing of a weekly precipitation sample is referred to as the bucket portion, whereas the portion receiving only minimal handling is referred to as the bottle portion. Positive bias in regard to blind-audit results indicates that the bucket portion has a higher concentration than the bottle portion. The paired t-test for the 1997 through 1999 blind- audit data indicates that routine sample handling, processing, and shipping introduced a positive bias (a=0.05) for calcium and chloride and a negative bias (cz=0.05) for hydrogen ion. During 1997 through 1999, the median paired differences between the bucket and bottle portions ranged from 0.00 milligram per liter for nitrate and ammonium to +0.010 milligram per liter for both chloride and sulfate. The median paired difference between the bucket and bottle portions for hydrogen ion was -1.086 microequivalents per liter, whereas for specific conductance, the median paired difference between the bucket and bottle portions was -0.200 microsiemen per centimeter during 1997 through 1999. Surface-chemistry effects due to variable amounts of precipitation contacting prewashed sample-collection and shipping-container surfaces were studied in the blind-audit program by using three different sample volumes. The sample- collection and shipping containers used for the blind-audit study were obtained from the site operator's supply and could have been used for precipitation samples. Results of a Kruskal-Wallis analysis of variance test of the relation between paired blind-audit sample differences in units of concentration and sample volume were statistically significant for magnesium, chloride, sulfate, and hydrogen ion during 1997 through 1999. Before 1994, at least 5 of the 10 analytes displayed a statistically significant difference between paired blind-audit differences in units of concentration and sample volume, supporting the premise that chemical reactions between the 13-liter bucket shipping container (primarily the butadiene o-ring lid of the shipping container) and the sample, which resulted in an increasing loss of hydrogen ion with increasing volume, have been eliminated by the new l-liter bottle sample- shipping protocol. The field-audit program measures the effects of field exposure, handling, and processing on the chemistry of NADP/NTN precipitation samples. In the field-audit program, the site operator is instructed to process and submit a quality- control sample following a standard 7-day, Tuesday-to-Tuesday sampling period with no

Water-Resources Investigations Report↗

Trace organic compounds in wet atmospheric deposition: an overview

An overview of the occurrence of organic compounds in wet atmospheric deposition is given. Multiplicity of sources and problems associated with source identification are discussed. Available literature is reviewed by using citations from Chemical Abstracts and Water Resources Abstracts through June 1985 and includes reports published through December 1984 that summarize current knowledge. Approaches to the chemical determination of organic compounds in precipitation are examined in addition to aspects of sampling protocols. Best methods for sample collection and preparation for instrumental analysis continue to be discussed among various investigators. Automatic wet-deposition-only devices for collection and extraction are preferred. Classes of organic compounds that have been identified in precipitation include a spectrum of compounds with differing properties of acidity or basicity, polarity, and water solubility. Those compounds that have been reported in rainfall, snowfall, and ice include hydrocarbons (both aromatic and nonaromatic), chlorinated derivatives of these hydrocarbons, carbonyl compounds (both acidic and nonacidic), and carboxylic acids and esters. Formic and acetic are the most abundant organic acids present. Cloudwater, fogwater, and mist also have been collected and analyzed for organic composition.

Water-Resources Investigations Report↗

Bias and precision of selected analytes reported by the National Atmospheric Deposition Program and National Trends Network, 1984

The U.S. Geological Survey operated a blind audit sample program during 1974 to test the effects of the sample handling and shipping procedures used by the National Atmospheric Deposition Program and National Trends Network on the quality of wet deposition data produced by the combined networks. Blind audit samples, which were dilutions of standard reference water samples, were submitted by network site operators to the central analytical laboratory disguised as actual wet deposition samples. Results from the analyses of blind audit samples were used to calculate estimates of analyte bias associated with all network wet deposition samples analyzed in 1984 and to estimate analyte precision. Concentration differences between double blind samples that were submitted to the central analytical laboratory and separate analyses of aliquots of those blind audit samples that had not undergone network sample handling and shipping were used to calculate analyte masses that apparently were added to each blind audit sample by routine network handling and shipping procedures. These calculated masses indicated statistically significant biases for magnesium, sodium , potassium, chloride, and sulfate. Median calculated masses were 41.4 micrograms (ug) for calcium, 14.9 ug for magnesium, 23.3 ug for sodium, 0.7 ug for potassium, 16.5 ug for chloride and 55.3 ug for sulfate. Analyte precision was estimated using two different sets of replicate measures performed by the central analytical laboratory. Estimated standard deviations were similar to those previously reported. (Author 's abstract)

Water-Resources Investigations Report↗

An assessment of the variability in performance of wet atmospheric deposition samplers

The variability in performance of two brands of wet/dry atmospheric deposition samplers were compared for 1 year at a sincle site. A total of nine samplers were used. Samples were collected weekly and analyzed for pH, specific conductance, common chemical constituents, and sample volume. Additionally, data on the duration of each sampler opening were recorded using a microdatalogger. These data disprove the common perception that samplers remain open throughout a precipitation event. The sensitivity of sampler sensors within the range tested did not have a defineable impact on sample collection. The nonnormal distribution within the data set necessitated application of the nonparametric Friedman Test to assess comparability of sample chemical composition and volume between and within sampler brands. Statistically significant differences existed for most comparisons, however the test did not permit quantification of their magnitudes. Differences in analyte concentrations between samplers were small. (USGS)

Water-Resources Investigations Report↗

External quality-assurance results for the National Atmospheric Deposition Program and the National Trends Network during 1986

During 1986, the U.S. Geological Survey operated three programs to provide external quality-assurance monitoring of the National Atmospheric Deposition Program and National Trends Network. An intersite-comparison program was used to assess the accuracy of onsite pH and specific-conductance determinations at quarterly intervals. The blind-audit program was used to assess the effect of routine sample handling on the precision and bias of program and network wet-deposition data. Analytical results from four laboratories, which routinely analyze wet-deposition samples, were examined to determine if differences existed between laboratory analytical results and to provide estimates of the analytical precision of each laboratory. An average of 78 and 89 percent of the site operators participating in the intersite-comparison met the network goals for pH and specific conductance. A comparison of analytical values versus actual values for samples submitted as part of the blind-audit program indicated that analytical values were slightly but significantly (a = 0.01) larger than actual values for pH, magnesium, sodium, and sulfate; analytical values for specific conductance were slightly less than actual values. The decreased precision in the analyses of blind-audit samples when compared to interlaboratory studies indicates that a large amount of uncertainty in network deposition data may be a result of routine field operations. The results of the interlaboratory comparison study indicated that the magnitude of the difference between laboratory analyses was small for all analytes. Analyses of deionized, distilled water blanks by participating laboratories indicated that the laboratories had difficulty measuring analyte concentrations near their reported detection limits. (USGS)

Water-Resources Investigations Report↗

External quality-assurance results for the National Atmospheric Deposition Program/National Trends Network during 1991

The U.S. Geological Survey used four programs in 1991 to provide external quality assurance for the National Atmospheric Deposition Program/National Trends Network (NADP/NTN). An intersite-comparison program was used to evaluate onsite pH and specific-conductance determinations. The effects of routine sample handling, processing, and shipping of wet-deposition samples on analyte determinations and an estimated precision of analyte values and concentrations were evaluated in the blind-audit program. Differences between analytical results and an estimate of the analytical precision of four laboratories routinely measuring wet deposition were determined by an interlaboratory-comparison program. Overall precision estimates for the precipitation-monitoring system were determined for selected sites by a collocated-sampler program. Results of the intersite-comparison program indicated that 93 and 86 percent of the site operators met the NADP/NTN accuracy goal for pH determinations during the two intersite-comparison studies completed during 1991. The results also indicated that 96 and 97 percent of the site operators met the NADP/NTN accuracy goal for specific-conductance determinations during the two 1991 studies. The effects of routine sample handling, processing, and shipping, determined in the blind-audit program indicated significant positive bias (a=.O 1) for calcium, magnesium, sodium, potassium, chloride, nitrate, and sulfate. Significant negative bias (or=.01) was determined for hydrogen ion and specific conductance. Only ammonium determinations were not biased. A Kruskal-Wallis test indicated that there were no significant (*3t=.01) differences in analytical results from the four laboratories participating in the interlaboratory-comparison program. Results from the collocated-sampler program indicated the median relative error for cation concentration and deposition exceeded eight percent at most sites, whereas the median relative error for sample volume, sulfate, and nitrate concentration at all sites was less than four percent. The median relative error for hydrogen ion concentration and deposition ranged from 4.6 to 18.3 percent at the four sites and as indicated in previous years of the study, was inversely proportional to the acidity of the precipitation at a given site. Overall, collocated-sampling error typically was five times that of laboratory error estimates for most analytes.

Water-Resources Investigations Report↗