Geology ReportsSearch

SEARCH · Geology Reports

Results for “Sensors”

Search indexed USGS publications on groundwater, aquifers, geologic maps, mineral resources and earthquakes. Explore source records by subject and place.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15Linked to original sources

Absolute radiometric calibration of Landsat using a pseudo invariant calibration site

Pseudo invariant calibration sites (PICS) have been used for on-orbit radiometric trending of optical satellite systems for more than 15 years. This approach to vicarious calibration has demonstrated a high degree of reliability and repeatability at the level of 1-3% depending on the site, spectral channel, and imaging geometries. A variety of sensors have used this approach for trending because it is broadly applicable and easy to implement. Models to describe the surface reflectance properties, as well as the intervening atmosphere have also been developed to improve the precision of the method. However, one limiting factor of using PICS is that an absolute calibration capability has not yet been fully developed. Because of this, PICS are primarily limited to providing only long term trending information for individual sensors or cross-calibration opportunities between two sensors. This paper builds an argument that PICS can be used more extensively for absolute calibration. To illustrate this, a simple empirical model is developed for the well-known Libya 4 PICS based on observations by Terra MODIS and EO-1 Hyperion. The model is validated by comparing model predicted top-of-atmosphere reflectance values to actual measurements made by the Landsat ETM+ sensor reflective bands. Following this, an outline is presented to develop a more comprehensive and accurate PICS absolute calibration model that can be Système international d'unités (SI) traceable. These initial concepts suggest that absolute calibration using PICS is possible on a broad scale and can lead to improved on-orbit calibration capabilities for optical satellite sensors.

IEEE Transactions on Geoscience and Remote Sensing

Landsat Collection 2 geometric calibration updates

The U.S. Geological Survey (USGS) changed the management and delivery of Landsat products to the public in its archive through the implementation of Collections. The Collections process ensures consistent data quality through time and across all the Landsat sensors with a few modifications to the metadata. The consistent data products from Collections are more conducive for applications such as time-series analysis, because the data can be used without a need for sensor-specific geometric or radiometric adjustments. The Collections process also allows for calibration improvements from updated reference sources, model trending, and enhanced algorithms that are grouped together and applied at one time, thus limiting the operational impacts to users. The first collection, Collection-1 was released in 2016, and Collection-2 is expected to be released in 2020. This paper addresses the geometric improvements to the Collection -2 dataset. Geometric improvements in Collection-2 include improvements to the geometric accuracy and interoperability of all Landsat products by implementing the Sentinel 2 Global Reference Image (GRI), improved elevation dataset using NASADEM and other sources of Digital Elevation Model (DEM) for terrain correction, improvements to the precision correction process for Enhanced Thematic Mapper Plus (ETM+) and Thematic Mapper (TM) sensors, changes to the Thermal Infrared Sensor (TIRS) to Operational Land Imager (OLI) alignment estimates, thermal band detector alignments and focal plane adjustments for ETM+, and improvements to the ETM+ sensor to attitude control system (ACS).

Conference Paper

Noise reduction in long‐period seismograms by way of array summing

Long‐period (>100 s period) seismic data can often be dominated by instrumental noise as well as local site noise. When multiple collocated sensors are installed at a single site, it is possible to improve the overall station noise levels by applying stacking methods to their traces. We look at the noise reduction in long‐period seismic data by applying the time–frequency phase‐weighted stacking method of Schimmel and Gallart (2007) as well as the phase‐weighted stacking (PWS) method of Schimmel and Paulssen (1997) to four collocated broadband sensors installed in the quiet Albuquerque Seismological Laboratory underground vault. We show that such stacking methods can improve vertical noise levels by as much as 10 dB over the mean background noise levels at 400 s period, suggesting that greater improvements could be achieved with an array involving multiple sensors. We also apply this method to reduce local incoherent noise on horizontal seismic records of the 2 March 2016 M w 7.8 Sumatra earthquake, where the incoherent noise levels at very long periods are similar in amplitude to the earthquake signal. To maximize the coherency, we apply the PWS method to horizontal data where relative azimuths between collocated sensors are estimated and compared with a simpler linear stack with no azimuthal rotation. Such methods could help reduce noise levels at various seismic stations where multiple high‐quality sensors have been deployed. Such small arrays may also provide a solution to improving long‐period noise levels at Global Seismographic Network stations.

Bulletin of the Seismological Society of America

Seismic Station Installation Orientation Errors at ANSS and IRIS/USGS Stations

Many seismological studies depend on the published orientations of sensitive axes of seismic instruments relative to north (e.g., Li et al., 2011). For example, studies of the anisotropic structure of the Earth’s mantle through SKS‐splitting measurements (Long et al., 2009), constraints on core–mantle electromagnetic coupling from torsional normal‐mode measurements (Dumberry and Mound, 2008), and models of three‐dimensional (3D) velocity variations from surface waves (Ekström et al., 1997) rely on accurate sensor orientation. Unfortunately, numerous results indicate that this critical parameter is often subject to significant error (Laske, 1995; Laske and Masters, 1996; Yoshizawa et al., 1999; Schulte‐Pelkum et al., 2001; Larson and Ekström, 2002). For the Advanced National Seismic System (ANSS; ANSS Technical Integration Committee, 2002), the Global Seismographic Network (GSN; Butler et al., 2004), and many other networks, sensor orientation is typically determined by a field engineer during installation. Successful emplacement of a seismic instrument requires identifying true north, transferring a reference line, and measuring the orientation of the instrument relative to the reference line. Such an exercise is simple in theory, but there are many complications in practice. There are four commonly used methods for determining true north at the ANSS and GSN stations operated by the USGS Albuquerque Seismological Laboratory (ASL), including gyroscopic, astronomical, Global Positioning System (GPS), and magnetic field techniques. A particular method is selected based on site conditions (above ground, below ground, availability of astronomical observations, and so on) and in the case of gyroscopic methods, export restrictions. Once a north line has been determined, it must be translated to the sensor location. For installations in mines or deep vaults, this step can include tracking angles through the one or more turns in the access tunnel leading to the vault (e.g., GSN station WCI in Wyandotte Cave, Indiana). Finally, the third source of error comes from the ability of field engineers to orient the sensor relative to the reference line. In order to quantify bounds on the errors in each step in the orientation process, we conducted a series of tests at the ASL using twelve GSN and ANSS field engineers. The results from this exercise allow us to estimate upper bounds on the precision of our ability to orient instruments, as well as identify the sources of error in the procedures. We are also able to identify systematic bias of various true‐north‐finding methods relative to one another. Although we are unable to estimate the absolute accuracy of our orientation measurements due to our inability to identify true north without some error, the agreement between independent methods for finding true north provides confidence in the different approaches, assuming no systematic bias. Finally, our study neglects orientation errors that are beyond the control of the field engineer during a station visit. These additional errors can arise from deviations in the sensitive axes of the instruments relative to the case markings, processing errors (Holcomb, 2002) when comparing horizontal orientations relative to other sensors (e.g., borehole installations), and deviations of the sensitive axes of instruments from true orthogonality (e.g., instruments with separate modules such as the Streckeisen STS‐1).

Seismological Research Letters

Do low-cost seismographs perform well enough for your network? An overview of laboratory tests and field observations of the OSOP Raspberry Shake 4D

Seismologists have recently begun utilizing low-cost nodal sensors in dense deployments to sample the seismic wavefield at unprecedented spatial resolution. Earthquake Early Warning Systems (EEWS) and other monitoring networks (e.g. wastewater injection) would additionally benefit from network densification; however, current nodal systems lack power systems and/or real-time data transmission required for these applications. A candidate sensor for these networks may instead be a low-cost, all-in-one package such as the OSOP Raspberry Shake 4D (RS-4D). The RS-4D includes a vertical component geophone, 3-component accelerometer, digitizer, and near real-time miniSEED data transmission, and costs only a few hundred dollars per unit. Here, we step through instrument testing of three RS-4Ds at the Albuquerque Seismological Laboratory. We find the geophones have sensitivities constrained to within 4% of nominal, but that they have relatively high self-noise levels compared to the broadband sensors typically used in seismic networks. To demonstrate the impact this would have on characterizing nearby events, we estimate local magnitudes of earthquakes in Oklahoma using Trillium Compact broadband sensor data from U.S. Geological Survey (USGS) aftershock deployments as well as 23 Raspberry Shakes operated by hobbyists and private owners within Oklahoma. We find that for ML 2.0-4.0 earthquakes at distances of 20-100 km from seismic stations, the Raspberry Shakes require events of magnitude ~0.3 larger than the broadband sensors in order to reliably estimate ML at a given distance from the epicenter. We conclude that RS-4Ds are suitable for densifying backbone networks designed for studies of local and regional events.

Seismological Research Letters

Airborne digital-image data for monitoring the Colorado River corridor below Glen Canyon Dam, Arizona, 2009 - Image-mosaic production and comparison with 2002 and 2005 image mosaics

Airborne digital-image data were collected for the Arizona part of the Colorado River ecosystem below Glen Canyon Dam in 2009. These four-band image data are similar in wavelength band (blue, green, red, and near infrared) and spatial resolution (20 centimeters) to image collections of the river corridor in 2002 and 2005. These periodic image collections are used by the Grand Canyon Monitoring and Research Center (GCMRC) of the U.S. Geological Survey to monitor the effects of Glen Canyon Dam operations on the downstream ecosystem. The 2009 collection used the latest model of the Leica ADS40 airborne digital sensor (the SH52), which uses a single optic for all four bands and collects and stores band radiance in 12-bits, unlike the image sensors that GCMRC used in 2002 and 2005. This study examined the performance of the SH52 sensor, on the basis of the collected image data, and determined that the SH52 sensor provided superior data relative to the previously employed sensors (that is, an early ADS40 model and Zeiss Imaging's Digital Mapping Camera) in terms of band-image registration, dynamic range, saturation, linearity to ground reflectance, and noise level. The 2009 image data were provided as orthorectified segments of each flightline to constrain the size of the image files; each river segment was covered by 5 to 6 overlapping, linear flightlines. Most flightline images for each river segment had some surface-smear defects and some river segments had cloud shadows, but these two conditions did not generally coincide in the majority of the overlapping flightlines for a particular river segment. Therefore, the final image mosaic for the 450-kilometer (km)-long river corridor required careful selection and editing of numerous flightline segments (a total of 513 segments, each 3.2 km long) to minimize surface defects and cloud shadows. The final image mosaic has a total of only 3 km of surface defects. The final image mosaic for the western end of the corridor has areas of cloud shadow because of persistent inclement weather during data collection. This report presents visual comparisons of the 2002, 2005, and 2009 digital-image mosaics for various physical, biological, and cultural resources within the Colorado River ecosystem. All of the comparisons show the superior quality of the 2009 image data. In fact, the 2009 four-band image mosaic is perhaps the best image dataset that exists for the entire Arizona part of the Colorado River.

Arizona

Geophysical investigation of the pressure field produced by water guns at a pond site in La Crosse, Wisconsin

Three different geophysical sensor types were used to characterize the underwater pressure waves generated by the underwater firing of a seismic water gun and their suitability for establishing a pressure barrier to potentially direct or prevent the movement of the Asian carps. The sensors used to collect the seismic information were blast rated hydrophones and underwater blast sensors. Specific location information for the water guns and the sensors was obtained using either laser rangefinders or differentially corrected global positioning systems (GPS). Two separate studies are discussed in this report. The two studies were completed during September 2012 and July 2013. Both of these studies took place in an earthen testing pond on the campus of Upper Midwest Environmental Sciences Center (UMESC) in La Crosse, Wisconsin. Previous studies had identified 5 pounds per square inch (lb/in 2 ) as a target value for the successful operation of a water gun barrier. The September 2012 study evaluated the performance of 1-cubic-inch (in 3) and 80-in 3 water guns. Data from the 1-in 3 gun showed that it produces a very planar wave with limited effect on the depths above and below its gun ports. The 1-in 3 gun did not produce the 5-lb/in 2 target pressure at a sufficient distance to be considered effective. The 80-in 3 gun produced a bowl-shaped pressure field with the 5-lb/in 2 target radius at the surface extending to 45 feet. The July 2013 study consisted of three scenarios: fish behavior, single gun assessment, and experimental barrier evaluation. The fish behavior scenario simulated the pond conditions from previous studies. Two 80-in 3 water guns were fired in the south end of the testing pond. Pressures essentially doubled from the testing of the single 80-in 3 water gun. The single gun assessment scenario sought to replicate the setup of the 80-in 3 scenario in September 2012, but with additional sensors to better define the pressure field. The 5-lb/in 2 target pressure field continued to show a radius ranging from 40 to 45 feet, dependent on the pressure of the input air. The final scenario, the experimental barrier evaluation, showed that a two-dimensional continuous plane of 5 lb/in 2 can be created between two 80-in 3 water guns to a separation of 99 feet and a depth of 6.5 feet with 1,500 lb/in 2 of input air.

Wisconsin

The use of continuous water-quality time-series data to compute nutrient loadings for selected Iowa streams, 2008–17

In support of nutrient reduction efforts, nitrate (as nitrate plus nitrite) and phosphorus loads and yields were computed for selected streams in Iowa based on continuously monitored sensor data for 2008–17 and 2014–17, respectively. Sample data were used to assess nitrate sensor bias and to create phosphorus-turbidity surrogate models. Where needed, nitrate loads were corrected for site-specific sensor bias, which was determined to be as high as 9.25 percent. Nitrate loads presented in this report using continuous (generally 15-minute interval) data were on average 4 percent less, but as much as 38 percent less, than annual loads computed from daily mean nitrate concentrations not corrected for sensor bias. Streamflow-based phosphorus models had poorer fit (adjusted coefficient of determination values less than 0.75) than turbidity-based models (adjusted coefficient of determination approximately 0.9). However, alternate models based on streamflow were used to obtain a more complete annual phosphorus load despite seasonal and fragmentary sensor data. Mean annual nitrate yields for 18 selected sites (96 site-years) ranged from 1.68 to 164 pounds per square mile per day (lb/mi 2 /d), compared to 19.4 lb/mi 2 /d average statewide yield needed to achieve the nitrate-reduction goal. Mean annual phosphorus yields for selected sites on the Maquoketa River, South Raccoon River, and West Nishnabotna River range from 1.57 to 7.19 lb/mi 2 /d, compared to 1.06 lb/mi 2 /d average statewide yield needed to achieve the phosphorus-reduction goal.

Iowa

Infrasound for volcano monitoring

Introduction Volcanic eruptions produce acoustic waves when volcanic gases and hot material rapidly expand in the atmosphere. Volcanic activity can produce acoustic signals with a wide range of frequencies, from very long period (>10 seconds) to audible (>20 hertz [Hz]), but the most energetic band is typically in the infrasound from 0.5 to 20 Hz. Studies of volcanic infrasound and the deployment of infrasound for volcano monitoring have increased rapidly in the past two decades as sensors have improved and as analytical tools have become more widely available. Improved sensors and tools have led to a growing diversity of eruptive activity being recorded and characterized, from Hawaiian to Plinian eruption styles at scales from local to global (Johnson and Ripepe, 2011; Fee and Matoza, 2013). Infrasound sensors on volcanoes are most commonly deployed locally with seismic stations, and the combination of co-located seismic and infrasound is more useful for characterizing unrest and detecting changes in activity than either data stream alone (for example, Lyons and others, 2016; Fee and others, 2017a; Matoza and others, 2018). At local (<15 kilometers [km]) to regional (15–250 km) distances from volcanoes, arrays of infrasound sensors are commonly deployed to detect coherent signals, constrain the direction to the source, and provide information on eruption dynamics; thus, infrasound is well suited to regional monitoring of volcanoes when local sensor networks are not feasible. A common usage of infrasound data in an observatory is to provide rapid confirmation that an explosion has occurred (for example, Coombs and others, 2018), although near-real-time eruption intensity quantification is also possible (Fee and others, 2010a; Ripepe and others, 2018; fig. C1). Infrasound is well suited to this task because it is not affected by clouds or precipitation and can propagate long distances with little attenuation. However, wind and ocean noise also produce infrasound, and spatiotemporal variability in the atmosphere can affect the propagation of infrasound, so care must be taken when deploying, analyzing, and interpreting the data. In addition to detecting and monitoring explosive activity, investigations of infrasound records from eruptions help constrain source processes, which in turn enhance syneruptive forecasting capabilities (for example, Fee and others, 2017b; Lyons and others, 2019). The following is a description of the capabilities recommended for real-time monitoring of eruptive phenomena with infrasound. Infrasound is also beginning to be used for tracking hazardous surface flows that occur on volcanoes, including pyroclastic density currents (Ripepe and others, 2010), lahars (Johnson and Palma, 2015), debris flows (Marchetti and others, 2019), snow avalanches (Havens and others, 2014), and lava flows (Patrick and others, 2019). Please refer to the chapter on lahars (this volume; Thelen and others, 2024a) for more information on this application.

Scientific Investigations Report

Measuring and computing natural ground-water recharge at sites in south-central Kansas

To measure the natural groundwater recharge process, two sites in south-central Kansas were instrumented with sensors and data microloggers. The atmospheric-boundary layer and the unsaturated and saturated soil zones were monitored as a single regime. Direct observations also were used to evaluate the measurements. Atmospheric sensors included an anemometer, a tipping-bucket rain gage, an air-temperature thermistor, a relative-humidity probe, a net radiometer, and a barometric-pressure transducer. Sensors in the unsaturated zone consisted of soil-temperature thermocouples, tensiometers coupled with pressure transducers and dial gages, gypsum blocks, and a neutron-moisture probe. The saturated-zone sensors consisted of a water-level pressure transducer, a conventional float gage connected to a variable potentiometer, soil thermocouples, and a number of multiple-depth piezometers. Evaluation of the operation of these sensors and recorders indicates that certain types of equipment, such as pressure transducers, are very sensitive to environmental conditions. A number of suggestions aimed at improving instrumentation of recharge investigations are outlined. Precipitation and evapotranspiration data, taken together with soil moisture profiles and storage changes, water fluxes in the unsaturated zone and hydraulic gradients in the saturated zone at various depths, soil temperature, water table hydrographs, and water level changes in nearby wells, describe the recharge process. Although the two instrumented sites are located in sand-dune environments in area characterized by a shallow water table and a sub-humid continental climate, a significant difference was observed in the estimated total recharge. The estimates ranged from less than 2.5 mm at the Zenith site to approximately 154 mm at the Burrton site from February to June 1983. The principal reasons that the Burrton site had more recharge than the Zenith site were more precipitation, less evapotranspiration, and a shallower depth to the water table. Effective recharge took place only during late winter and spring. No summer or fall recharge was observed at either site during the observation period of this study. (Author 's abstract)

Water-Resources Investigations Report

Comparison of accuracy and completeness of data obtained from three types of automatic water-quality monitors

A comparison of data (specific conductance, dissolved-oxygen concentration, temperature, and pH) collected by the U.S. Geological Survey flowthrough monitor, the U.S. Geological Survey minimonitor, and a self-contained commercial 'packaged-sensor' system indicates that the data obtained by means of the most complete of the three systems. The U.S. Geological Survey flowthrough monitor is powered by 120-volt alternating current and in a heated weather-proof shelter. A pumping system brings water from the stream to sensors clustered in a sample clustered in a sample chamber located in the shelter. This instrument measures output from the senors; data are recorded in binary-coded decimal form on a 16-channel punched-paper tape recorder tape recorder housed in the shelter. The U.S. Geological Survey's minimonitor is powered by an external battery and is housed in a weatherproof shelter. This instrument measures output of instream sensors with extension cables having underwater connectors; data are recorded in binary-coded decimal form on a 16-channel punched-paper tape recorder housed in the shelter. The packaged-sensor system also measures output of senors housed in a packages that is submerged in the stream. It has internal power supply, no moving parts, and does not requires a weatherproof shelter; data are stored are stored in solid-state memory. Minimonitors were installed at four sites in Ohio where U.S. Geological survey flowthrough were in operation. Two package-sensor systems also were assigned to each site and were alternated every two weeks. Detailed records were kept of (1) field measurements, for comparison with monitor-system data from each instrument, and (2) equipment problems that resulted in loss of data. Results of the comparisons shows that the flow-through monitor gave the most accurate and the most complete data.

Water-Resources Investigations Report

Community tools for cartographic and photogrammetric processing of Mars Express HRSC images

The High Resolution Stereo Camera (HRSC) on the Mars Express orbiter (Neukum et al. 2004) is a multi-line pushbroom scanner that can obtain stereo and color coverage of targets in a single overpass, with pixel scales as small as 10 m at periapsis. Since commencing operations in 2004 it has imaged ~ 77 % of Mars at 20 m/pixel or better. The instrument team uses the Video Image Communication And Retrieval (VICAR) software to produce and archive a range of data products from uncalibrated and radiometrically calibrated images to controlled digital topographic models (DTMs) and orthoimages and regional mosaics of DTM and orthophoto data (Gwinner et al. 2009; 2010b; 2016). Alternatives to this highly effective standard processing pipeline are nevertheless of interest to researchers who do not have access to the full VICAR suite and may wish to make topographic products or perform other (e. g., spectrophotometric) analyses prior to the release of the highest level products. We have therefore developed software to ingest HRSC images and model their geometry in the USGS Integrated Software for Imagers and Spectrometers (ISIS3), which can be used for data preparation, geodetic control, and analysis, and the commercial photogrammetric software SOCET SET (® BAE Systems; Miller and Walker 1993; 1995) which can be used for independent production of DTMs and orthoimages. The initial implementation of this capability utilized the then-current ISIS2 system and the generic pushbroom sensor model of SOCET SET, and was described in the DTM comparison of independent photogrammetric processing by different elements of the HRSC team (Heipke et al. 2007). A major drawback of this prototype was that neither software system then allowed for pushbroom images in which the exposure time changes from line to line. Except at periapsis, HRSC makes such timing changes every few hundred lines to accommodate changes of altitude and velocity in its elliptical orbit. As a result, it was necessary to split observations into blocks of constant exposure time, greatly increasing the effort needed to control the images and collect DTMs. Here, we describe a substantially improved HRSC processing capability that incorporates sensor models with varying line timing in the current ISIS3 system (Sides 2017) and SOCET SET. This enormously reduces the work effort for processing most images and eliminates the artifacts that arose from segmenting them. In addition, the software takes advantage of the continuously evolving capabilities of ISIS3 and the improved image matching module NGATE (Next Generation Automatic Terrain Extraction, incorporating area and feature based algorithms, multi-image and multi-direction matching) of SOCET SET, thus greatly reducing the need for manual editing of DTM errors. We have also developed a procedure for geodetically controlling the images to Mars Orbiter Laser Altimeter (MOLA) data by registering a preliminary stereo topographic model to MOLA by using the point cloud alignment ( pc_align ) function of the NASA Ames Stereo Pipeline (ASP; Moratto et al. 2010). This effectively converts inter-image tiepoints into ground control points in the MOLA coordinate system. The result is improved absolute accuracy and a significant reduction in work effort relative to manual measurement of ground control. The ISIS and ASP software used are freely available; SOCET SET, is a commercial product. By the end of 2017 we expect to have ported our SOCET SET HRSC sensor model to the Community Sensor Model (CSM; Community Sensor Model Working Group 2010; Hare and Kirk 2017) standard utilized by the successor photogrammetric system SOCET GXP that is currently offered by BAE. In early 2018, we are also working with BAE to release the CSM source code under a BSD or MIT open source license.

The International Archives of the Photogrammetry,

New hydrologic instrumentation in the U.S. Geological Survey

New water-level sensing and recording instrumentation is being used by the U.S. Geological Survey for monitoring water levels, stream velocities, and water-quality characteristics. Several of these instruments are briefly described. The Basic Data Recorder (BDR) is an electronic data logger, that interfaces to sensor systems through a serial-digital interface standard (SDI-12), which was proposed by the data-logger industry; the Incremental Shaft Encoder is an intelligent water-level sensor, which interfaces to the BDR through the SDI-12; the Pressure Sensor is an intelligent, nonsubmersible pressure sensor, which interfaces to the BDR through the SDI-12 and monitors water levels from 0 to 50 feet; the Ultrasonic Velocity Meter is an intelligent, water-velocity sensor, which interfaces to the BDR through the SDI-12 and measures the velocity across a stream up to 500 feet in width; the Collapsible Hand Sampler can be collapsed for insertion through holes in the ice and opened under the ice to collect a water sample; the Lighweight Ice Auger, weighing only 32 pounds, can auger 6- and 8-inch holes through approximately 3.5 feet of ice; and the Ice Chisel has a specially hardened steel blade and 6-foot long, hickory D-handle.

Conference Paper

Rainfall and River Currents Retrieved from Microwave Backscatter

The use of CW microwave sensors in yielding information on both river surface velocities and rain rates was discussed. Eight CW microwave sensors were installed at Cowlitz river in Western Washington State in the US. The sensors measured the river surface velocity via Doppler shifts at eight locations across the river. Comparison of the surface velocities derived from the sensors mounted on the bridge with those measured by current meters and acoustic sensors demonstrated good agreement.

Conference Paper

Identifying conditions associated with outliers produced by three different chlorophyll fluorometers: A comparison of instrumentation and development of correction formulae

Measurements of chlorophyll concentration reported by fluorometers (fChl) are used in environmental research and monitoring, as inputs to models, and in the interpretation of remote sensing data. Researchers and managers benefit from understanding how to interpret and ensure the accuracy of fChl data collected by in situ fluorometers. Although fChl values produced by different manufacturers are often in agreement with discrete laboratory-derived Chlorophyll a (Chl a ) concentration measurements, there are instances in which results significantly differ. Further, when measuring fChl side by side, different fluorometers may report values that differ significantly from each other, despite passing calibration checks prior to deployment. We compared environmental conditions and phytoplankton species composition associated with instances in which fChl measurements from three different fluorometers (EXO2 Total Algae Smart Sensor, YSI Inc./Xylem Inc., Yellow Springs, Ohio; FluoroProbe III, bbe Moldaenke GmbH, Kiel, Germany; WETStar, Sea-Bird Scientific, Bellevue, Washington) were significantly different from laboratory-derived Chl a concentrations. Results indicated that elevated primary productivity, as indicated by high pH, dissolved oxygen, and the ratio of Chl a to phaeophytin, were correlated with underestimated fChl values recorded by each sensor. After removing outliers, we determined unique correction guidance for each of the three sensors and demonstrated that after applying correction formulae, fChl measurements produced by each sensor became directly comparable.

California

Land surface phenology

Certain vegetation types (e.g., deciduous shrubs, deciduous trees, grasslands) have distinct life cycles marked by the growth and senescence of leaves and periods of enhanced photosynthetic activity. Where these types exist, recurring changes in foliage alter the reflectance of electromagnetic radiation from the land surface, which can be measured using remote sensors. The timing of these recurring changes in reflectance is called land surface phenology (LSP). During recent decades, a variety of methods have been used to derive LSP metrics from time series of reflectance measurements acquired by satellite-borne sensors. In contrast to conventional phenology observations, LSP metrics represent the timing of reflectance changes that are driven by the aggregate activity of vegetation within the areal unit measured by the satellite sensor and do not directly provide information about the phenology of individual plants, species, or their phenophases. Despite the generalized nature of satellite sensor-derived measurements, they have proven useful for studying changes in LSP associated with various phenomena. This chapter provides a detailed overview of the use of satellite remote sensing to monitor LSP. First, the theoretical basis for the application of satellite remote sensing to the study of vegetation phenology is presented. After establishing a theoretical foundation for LSP, methods of deriving and validating LSP metrics are discussed. This chapter concludes with a discussion of major research findings and current and future research directions.

Book chapter

Imaging spectroscopy for the detection, assessment and monitoring of natural and anthropogenic hazards

Natural and anthropogenic hazards have the potential to impact all aspects of society including its economy and the environment. Diagnostic data to inform decision-making are critical for hazard management whether for emergency response, routine monitoring or assessments of potential risks. Imaging spectroscopy (IS) has unique contributions to make via the ability to provide some key quantitative diagnostic information. In this paper, we examine a selection of key case histories representing the state of the art to gain an insight into the achievements and perspectives in the use of visible to shortwave infrared IS for the detection, assessment and monitoring of a selection of significant natural and anthropogenic hazards. The selected key case studies examined provide compelling evidence for the use of the IS technology and its ability to contribute diagnostic information currently unattainable from operational spaceborne Earth observation systems. User requirements for the applications were also evaluated. The evaluation showed that the projected launch of spaceborne IS sensors in the near-, mid and long term future, together with the increasing availability, quality and moderate cost of off the shelf sensors, the possibilities to couple unmanned autonomous systems with miniaturized sensors, should be able to meet these requirements. The challenges and opportunities for the scientific community in the future when such data become available will then be ensuring consistency between data from different sensors, developing techniques to efficiently handle, process, integrate and deliver the large volumes of data, and most importantly translating the data to information that meets specific needs of the user community in a form that can be digested/understood by them. The latter is especially important to transforming the technology from a scientific to an operational tool. Additionally, the information must be independently validated using current trusted practices and uncertainties quantified before IS derived measurement can be integrated into operational monitoring services.

Colorado

Advantage of hyperspectral EO-1 Hyperion over multispectral IKONOS, GeoEye-1, WorldView-2, Landsat ETM+, and MODIS vegetation indices in crop biomass estimation

Crop biomass is increasingly being measured with surface reflectance data derived from multispectral broadband (MSBB) and hyperspectral narrowband (HNB) space-borne remotely sensed data to increase the accuracy and efficiency of crop yield models used in a wide array of agricultural applications. However, few studies compare the ability of MSBBs versus HNBs to capture crop biomass variability. Therefore, we used standard data mining techniques to identify a set of MSBB data from the IKONOS, GeoEye-1, Landsat ETM+, MODIS, WorldView-2 sensors and compared their performance with HNB data from the EO-1 Hyperion sensor in explaining crop biomass variability of four important field crops (rice, alfalfa, cotton, maize). The analysis employed two-band (ratio) vegetation indices (TBVIs) and multiband (additive) vegetation indices (MBVIs) derived from Singular Value Decomposition (SVD) and stepwise regression. Results demonstrated that HNB-derived TBVIs and MBVIs performed better than MSBB-derived TBVIs and MBVIs on a per crop basis and for the pooled data: overall, HNB TBVIs explained 5&ndash;31% greater variability when compared with various MSBB TBVIs; and HNB MBVIs explained 3&ndash;33% greater variability when compared with various MSBB MBVIs. The performance of MSBB MBVIs and TBVIs improved mildly, by combining spectral information across multiple sensors involving IKONOS, GeoEye-1, Landsat ETM+, MODIS, and WorldView-2. A number of HNBs that advance crop biomass modeling were determined. Based on the highest factor loadings on the first component of the SVD, the &ldquo;red-edge&rdquo; spectral range (700&ndash;740 nm) centered at 722 nm (bandwidth = 10 nm) stood out prominently, while five additional and distinct portions of the recorded spectral range (400&ndash;2500 nm) centered at 539 nm, 758 nm, 914 nm, 1130 nm, 1320 nm (bandwidth = 10 nm) were also important. The best HNB vegetation indices for crop biomass estimation involved 549 and 752 nm for rice ( R 2 = 0.91); 925 and 1104 nm for alfalfa ( R 2 = 0.81); 722 and 732 nm for cotton ( R 2 = 0.97); and 529 and 895 nm for maize ( R 2 = 0.94). The higher spectral resolution of the EO-1 Hyperion hyperspectral sensor and the ability of users to choose distinct HNBs for improved crop biomass estimation outweigh the benefits that come with higher spatial resolution of MSBBs.

California