Geology ReportsSearch

USGS · sir20185073

Geochemistry and microbiology of groundwater and solids from extraction and monitoring wells and their relation to well efficiency at a Federally operated confined disposal facility, East Chicago, Indiana

Abstract

In cooperation with the U.S. Army Corps of Engineers, Chicago District, the U.S. Geological Survey investigated the processes affecting water quality, geochemistry, and microbiology in representative extraction and monitoring wells at a confined disposal facility (CDF) in East Chicago, Indiana. The CDF is a 140-acre Federally-managed facility that was the former location of an oil refinery and is now used for the long-term disposal and storage of dredge material from the Indiana Harbor and Indiana Harbor Canal. Residual petroleum hydrocarbons and leachate from the CDF are contained within the facility by use of a groundwater cutoff wall. The wall consists of a soil-bentonite slurry and a gradient control system made up of an automated network of 96 extraction wells, 42 monitoring wells, and 2 ultrasonic sensors that maintain an inward hydraulic gradient at the site. The pumps in the extraction wells require vigilant maintenance and must be replaced when unable to withdraw water at a rate sufficient to maintain the required inward gradient. The wells are screened in the Calumet aquifer, a coarse-grained sand and gravel unit that extends approximately 35 feet below the land surface and is not utilized for drinking-water supply at the CDF or in the surrounding area. This study was initiated to identify the cause of decreased pump discharges and to identify potential mitigation strategies. For this study, the U.S. Geological Survey collected groundwater and solids from monitoring and extraction wells. Groundwater samples were collected during June 2014 for precautionary health screening and on four occasions during September 2014 through November 2014. Groundwater samples collected from two extraction wells during June 2014 were analyzed for concentrations of anthropogenic organic constituents. During September through November 2014, groundwater samples were collected from one additional extraction well, and samples from three monitoring wells were analyzed for concentrations of inorganic and organic constituents, dissolved gases, and bacterial abundance and diversity. Solid samples were collected during April 2014, during September 2014 through November 2014, and during November 2016. Solid samples were collected from the exterior of extraction-well pumps and as flocculent from water samples. Solid samples were collected from 10 wells, including 1 extraction well and 3 monitoring wells sampled for water quality. Solid samples were analyzed for mineralogy, solid-phase habit, geochemistry, and organic composition. The following is a list of observations that were made during this study: (1) the water quality is substantially variable among the six well locations sampled as part of this study—lower (more negative) redox values and higher concentrations of many constituents (including calcium, magnesium, sodium, and sulfate) and properties (including dissolved solids, hardness, and turbidity) were detected in sampled wells located near the extraction wells with the highest frequency of failure; (2) water-level drawdown is variable between extraction wells—wells with the greatest drawdown may pull deeper groundwater into the borehole; (3) dissolved gas results indicate reducing oxidation-reduction processes in the aquifer material that can feasibly contribute iron, carbon dioxide, and other byproducts from hydrocarbon degradation to precipitates and solids that accumulate on and impair pump operation; (4) crystalline and amorphous solid-phase minerals are precipitating in the borehole; (5) several types of bacteria are present in water pumped from extraction wells and are likely responsible for bonding mineral and microbiologic matter to the pump (and other well components); and (6) bacteria may create microenvironments that facilitate precipitation of solids or inhibit dissolution of unstable minerals once the bacteria adhere to biofilm attached to the pump. Results of the study indicate that bacteria may be accumulating and entrapping solid material on the exterior of pumps. This accumulation reduces heat transfer and water discharge from the pump and may lead to decreased efficiency or mechanical failure. Observations could not be made on the well screen, gravel pack, or surrounding geologic formation; therefore, mitigating measures in the borehole may not solve well-productivity issues. Remedies for the pump fouling problems were derived from the review and interpretation of data collected during this study and from information documented in other sources about groundwater well fouling. Potential remedies to problems associated with pump fouling at the CDF may include the following: (1) reducing attractiveness of the extraction wells for microbiological growth by modifying the chemical or physical environment of the well, (2) modifying the pump exterior to decrease microbiological adherence, (3) changing the pumping regime to control the chemistry of water entering the well from the surrounding aquifer material, (4) modifying the pumps to be less physically and thermally attractive, and (5) removing hydrocarbons from groundwater and the aquifer material surrounding the wells or adding surfactants to make them more mobile. Pilot scale testing may be necessary to identify the most effective treatment or combination of treatments.

Explore related subjects

90° N90° S · 180° W ← longitude → 180° E
Source-reported bounding extent: 41.59105362325491° to 41.71444263601197° latitude; -87.52395629882812° to -87.32585906982422° longitude. This indicates report coverage, not an exact sampling location. View area on OpenStreetMap.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Randall E. Bayless, Travis R. Cole, David C. Lampe, R. E. Travis, Marjorie S. Schulz, Paul M. Buszka. 2018-07-24. Geochemistry and microbiology of groundwater and solids from extraction and monitoring wells and their relation to well efficiency at a Federally operated confined disposal facility, East Chicago, Indiana. https://doi.org/10.3133/sir20185073

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

Monitoring recreation on federally managed lands and waters—Aspects of visitor use

Federally managed public lands and waters receive around 1 billion recreational visits each year. Data on these visitors can aid in guiding policy decisions, managing resources effectively, and communicating the economic contributions of lands and waters. This report explores the methods used by agencies to collect data on aspects of recreational visitor use to Federal lands and waters (apart from visitation numbers, which are the focus of a companion publication). Aspects of recreational visitor use include visitor demographics, recreational activity participation, visitor satisfaction, visitor attitudes and experiences, trip characteristics, and economic contributions. We review practices used to understand aspects of visitor use across seven Federal agencies, revealing similarities such as the use of visitor intercept surveys and coverage of similar topic areas, and differences in how survey programs are operationalized and how specific questions on visitor surveys are worded. We also evaluate emerging technologies, such as geolocated social media and mobile device location data, for their potential to aid in understanding aspects of visitor use. This report concludes with potential opportunities to enhance data collection and coordination, ensuring cost-effective data collection and informed decision making.

Scientific Investigations Report

Evaluation of best management practices at an edge-of-field site in the Eagle Creek watershed, Ohio, 2012–20

In 2010, the U.S. Geological Survey worked in partnership with the Great Lakes Restoration Initiative and the Natural Resources Conservation Service to identify farm fields in priority watersheds—watersheds critically important to Great Lake health. Intensive best management practices were implemented in five States to test the efficacy of best management practices, also referred to as agricultural conservation practices, to reduce sediment and nutrient runoff on agricultural fields. These fields were chosen as representatives of the priority watersheds because their farming practices and geographical conditions were common among farms in those watersheds. A farm site located near Findlay, Ohio, in the Eagle Creek watershed used two conservation practices, cover crop (Natural Resources Conservation Service practice standard 340) and variable rate technology (VRT; Natural Resources Conservation Service practice standard 590), which represent common practices in the Maumee priority watershed. This study monitored surface runoff and subsurface tile runoff at the Eagle Creek watershed site. The effects of cover crop and VRT nutrient application on sediment and nutrient runoff were assessed from October 2012 to September 2020. Cover crops were applied in fall of 2016, 2017, and 2018, coinciding with VRT applications. The following parameters were analyzed as part of the study: runoff discharge; peak discharge; and concentrations and loads of total phosphorus, particulate phosphorus, dissolved reactive phosphorus, and suspended sediment. High peak runoff events disproportionally affected nutrient concentrations and loads in runoff. A threshold of the 85th percentile of the peak discharge was chosen to assess the effect of cover crop and VRT nutrient application on nutrient mitigation at each gage. Runoff events below the 85th percentile were considered small, and runoff events over the 85th percentile were considered large. Concentrations from collected water-quality samples were used for the analysis; estimated concentrations were excluded from the statistical evaluation. All surface runoff parameters during small runoff events, except surface runoff volume, were significantly lower in the period with cover crops and VRT implementation. Contrarily, subsurface runoff parameters during small events were not statistically different between the periods with and without cover crops and VRT implementation. Surface and subsurface parameters during large events were also not statistically different between the periods with and without cover crops and VRT implementation. These results indicate cover crops and VRT may improve water quality during small runoff events, but additional best management practices that mitigate large runoff events may lead to greater water-quality improvement given the contribution of large events to overall losses.

Ohio

Continuous monitoring and temporal variability of fluorescence of dissolved organic matter in karst groundwater of the Edwards aquifer, south-central Texas, 2019–24

Widespread urbanization on the Edwards aquifer recharge zone in south-central Texas has prompted the development of new approaches and tools for evaluating the current and future status of water quality in the San Antonio and Barton Springs segments of the Edwards aquifer. The U.S. Geological Survey, in cooperation with the San Antonio Water System and the City of Austin, applied continuous monitoring of fluorescence of dissolved organic matter (fDOM) to characterize the sources and transport of dissolved organic matter and associated constituents in the Edwards aquifer. Continuous fDOM time-series data were adjusted using empirically derived temperature, turbidity, and inner-filter-effect correction factors prior to analysis and interpretation. Fully corrected fDOM time-series data from the study sites were evaluated for short- and long-term temporal variability in fDOM in the context of the hydrologic and climatic conditions that occurred during the 5-year study period to understand vulnerability of the aquifer to potential contaminants in recharge. Study results indicate that fDOM is an effective proxy for dissolved organic carbon that, in turn, is indicative of the influx of recent surface water and associated contaminants, and thus, aquifer vulnerability to those contaminants. Although other continuously monitored water-quality parameters provide insights into changes in water quality in response to varying hydrologic conditions, the quantitative relation between fDOM and dissolved organic carbon directly indicates the timing and magnitude of pulses of organic constituents derived from the land surface, whereas other water-quality parameters do not.

Texas