Geology Reports⌕ Search

USGS · sir20165088

Completion summary for boreholes TAN-2271 and TAN‑2272 at Test Area North, Idaho National Laboratory, Idaho

Abstract

In 2015, the U.S. Geological Survey, in cooperation with the U.S. Department of Energy, drilled and constructed boreholes TAN-2271 and TAN-2272 for stratigraphic framework analyses and long-term groundwater monitoring of the eastern Snake River Plain aquifer at the Idaho National Laboratory in southeast Idaho. Borehole TAN-2271 initially was cored to collect continuous geologic data, and then re-drilled to complete construction as a monitor well. Borehole TAN-2272 was partially cored between 210 and 282 feet (ft) below land surface (BLS) then drilled and constructed as a monitor well. Boreholes TAN-2271 and TAN-2272 are separated by about 63 ft and have similar geologic layers and hydrologic characteristics based on geologic, geophysical, and aquifer test data collected. The final construction for boreholes TAN-2271 and TAN-2272 required 10-inch (in.) diameter carbon-steel well casing and 9.9-in. diameter open-hole completion below the casing to total depths of 282 and 287 ft BLS, respectively. Depth to water is measured near 228 ft BLS in both boreholes. Following construction and data collection, temporary submersible pumps and water-level access lines were placed to allow for aquifer testing, for collecting periodic water samples, and for measuring water levels. Borehole TAN-2271 was cored continuously, starting at the first basalt contact (about 33 ft BLS) to a depth of 284 ft BLS. Excluding surface sediment, recovery of basalt and sediment core at borehole TAN-2271 was better than 98 percent. Based on visual inspection of core and geophysical data, material examined from 33 to 211ft BLS primarily consists of two massive basalt flows that are about 78 and 50 ft in thickness and three sediment layers near 122, 197, and 201 ft BLS. Between 211 and 284 ft BLS, geophysical data and core material suggest a high occurrence of fractured and vesicular basalt. For the section of aquifer tested, there are two primary fractured aquifer intervals: the first between 235 and 255 ft BLS and the second between 272 and 282 ft BLS. Basalt texture for borehole TAN-2271 generally was described as aphanitic, phaneritic, and porphyritic. Sediment layers, starting near 122 ft BLS, generally were composed of fine-grained sand and silt with a lesser amount of clay. Basalt flows generally ranged in thickness from 2 to 78 ft and varied from highly fractured to dense with high to low vesiculation. Geophysical data and limited core material collected from TAN-2272 show similar lithologic sequences to those reported for TAN-2271. Geophysical and borehole video logs were collected during certain stages of the drilling and construction process at boreholes TAN-2271 and TAN-2272. Geophysical logs were examined synergistically with available core material to confirm geologic and hydrologic similarities and suggest possible fractured network interconnection between boreholes TAN-2271 and TAN-2272. Natural gamma log measurements were used to assess the completeness of the vapor port lines behind 10-in. diameter well casing. Electromagnetic flow meter results were used to identify downward flow conditions that exist for boreholes TAN-2271 and TAN-2272. Furthermore, gyroscopic deviation measurements were used to measure horizontal and vertical displacement at all depths in boreholes TAN-2271 and TAN-2272. After borehole construction was completed, single‑well aquifer tests were done within wells TAN-2271 and TAN ‑ 2272 to provide estimates of transmissivity and hydraulic conductivity. The transmissivity and hydraulic conductivity were estimated for the pumping well and observation well during the aquifer tests conducted on August 25 and August 27, 2015. Estimates for transmissivity range from 4.1 . 10 3 feet squared per day (ft 2 /d) to 8.1 . 10 3 ft 2 /d; estimates for hydraulic conductivity range from 5.8 to 11.5 feet per day (ft/d). Both TAN-2271 and TAN ‑ 2272 show sustained pumping rates of about 30 gallons per minute (gal/min) with measured drawdown in the pumping well of 1.96 ft and 1.14 ft, respectively. The transmissivity estimates for wells tested were within the range of values determined from previous aquifer tests in other wells near Test Area North. Groundwater samples were collected from both wells and were analyzed for cations, anions, metals, nutrients, volatile organic compounds, stable isotopes, and radionuclides. Groundwater samples for most of the inorganic constituents showed similar water chemistry in both wells. Groundwater samples for strontium-90, trichloroethene, and vinyl chloride exceeded maximum contaminant levels for public drinking water supplies in one or both wells.

Explore related subjects

90° N90° S · 180° W ← longitude → 180° E
Source-reported bounding extent: 43.54058479482877° to 44.545462718849755° latitude; -113.65905761718749° to -111.829833984375° longitude. This indicates report coverage, not an exact sampling location. View area on OpenStreetMap.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Brian V. Twining, Roy C. Bartholomay, Mary Hodges. 2016-06-30. Completion summary for boreholes TAN-2271 and TAN‑2272 at Test Area North, Idaho National Laboratory, Idaho. https://doi.org/10.3133/sir20165088

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

Baseline water-quality inventory and summary for the Paterson Great Falls National Historical Park, New Jersey

The Paterson Great Falls National Historical Park (PAGR), established in 2011 in the City of Paterson, New Jersey, contains many cultural, historical, and natural resources. Because of the PAGR’s young age and limited resources, a long record of natural resource data is not available for use to guide future park management and planning decisions. A detailed natural resource inventory was identified as an immediate need in the “Foundation Document—Paterson Great Falls National Historical Park,” given the history of extensive industrial activity throughout the PAGR and the Passaic River Basin. The U.S. Geological Survey, in cooperation with the National Park Service and the Urban Waters Federal Partnership for the Lower Passaic River, inventoried water-quality monitoring efforts and compiled historical water-quality data from secondary data sources to define baseline conditions in the PAGR and the surrounding study area. This report documents the methods used to harmonize water-quality data aggregated from multiple sources for the PAGR study area. Procedures implemented during data harmonization include compiling data from multiple sources, assessing the dataset for completeness, addressing metadata concerns, and creating a consistent and quality-assured dataset for future analysis. The harmonized dataset contains 14 aggregated surface-water sites, 1,103 individual sampling days, and 32,000 water-quality records throughout the period of record defined for this study (1952–2021). Summary statistics and comparison to water-quality criteria are provided for focus parameters that can support PAGR management, including field properties, suspended material, total dissolved solids, specific conductance, chloride, sulfate, Escherichia coli, nutrients, contaminants of concern related to fish consumption advisories, and litter and floatable debris. A spatial data gap was identified for the recreational area near the base of the Great Falls and immediately downstream from a known combined sewer overflow discharge location. Analytic data gaps were identified for continuous streamflow and water-quality parameters, floatable debris characterization, and harmful algal blooms identification. Continuous collection of contaminants of concern was identified as a temporal data gap, as these parameters were not consistently collected within the study area. The water-quality data synthesis and summary presented in this report can assist PAGR staff in understanding the complex baseline water resources within the study area and can serve as a baseline to design future water-quality monitoring efforts and evaluate changes in water quality over time. The harmonized dataset, as well as future New Jersey Department of Environmental Protection and New Jersey Harbor Discharge Group monitoring data and assessments, can also be used to examine the status and trends in surface-water quality, support compliance with the Clean Water Act (33 U.S.C. 1251 et seq.), and further investigate changes to park water resources that can affect ecological and human health.

New Jersey↗

Slip tendency and dilation tendency of Quaternary faults in the Great Basin region, Arizona, California, Idaho, Nevada, Oregon, Utah, and Wyoming

This report presents the results of slip tendency and dilation tendency analysis of Quaternary faults in the Great Basin region, in the states of Arizona, California, Idaho, Nevada, Oregon, Utah, and Wyoming. This effort was undertaken as part of two studies: the U.S. Department of Energy Geothermal Technologies Office-funded Innovative Geothermal Exploration through Novel Investigations of Undiscovered Systems (INGENIOUS) project, which is a multidisciplinary, multi-institution effort to develop new methodologies and best practices to accelerate the discovery of new, commercially viable hydrothermal resources; and the U.S. Geological Survey Geothermal Resources Investigations Project. The goal of this work is to identify faults and fault segments that are appropriately oriented to be stress-loaded for slip or to dilate under the ambient stress conditions. Both conditions may make such faults more likely to host permeability and fluid flow relative to other faults in the region. Slip tendency and dilation tendency were calculated for all fault segments in the study area from the U.S. Geological Survey Quaternary Fault and Fold Database. Results demonstrate that faults with high slip tendency and dilation tendency are common in the Great Basin region. The areas containing many high slip tendency and dilation tendency fault segments are associated with high strain rates. These areas also host a relatively high proportion of the known hydrothermal systems. This indicates that faults with high slip tendency and dilation tendency in areas with high strain-rate are potentially most prospective for hosting hydrothermal systems. The database published in coordination with this report contains the slip tendency and dilation tendency results data, including the fault geometry and stress data used to calculate these quantities, for both the Great Basin study area and the smaller INGENIOUS study area.

Arizona, California, Idaho, Nevada, Oregon, Utah, ↗

A spatial analysis of the groundwater emergence flood hazard in Long Island, New York, and coastal areas surrounding Long Island Sound in New York, Connecticut, and Rhode Island

Long Island, New York, and nearby coastal areas surrounding Long Island Sound are densely populated and, like other coastal areas, are susceptible to flooding from several potential sources, including stormwater from precipitation events, tidal flooding and storm surge, and groundwater emergence flooding. Groundwater emergence fooding refers to the intersection of a rising water table with land surface or critical infrastructure. Many studies of flood drivers either neglect or only briefly discuss how shallow groundwater conditions may contribute to or exacerbate flood conditions. As a part of a comprehensive study of compound flood hazards in the coastal areas of Long Island and Long Island Sound, a spatial analysis was completed by the U.S. Geological Survey, in cooperation with the Environmental Protection Agency’s Long Island Sound Partnership, formerly called the Long Island Sound Study, using available regional datasets to characterize the potential hazard for groundwater emergence flooding. The approximately 3,100 square mile study area was subdivided into 11,407 grid cells that were 900 meters by 900 meters (approximately 3,000 feet by 3,000 feet), for the purpose of integrating the spatial datasets to calculate and map the groundwater emergence flood hazard. The depth to the water table, hydrologic soil groups, and National Land Cover Database were harmonized to the common grid. A groundwater emergence flood hazard score was calculated for each grid cell for current average conditions following a set of rules accounting for the depth to the water table and the percentage of area within each cell with slow infiltrating soils. A scenario with a higher sea-level position was also calculated for the Long Island part of the study area. The calculated groundwater emergence flood hazard score was reviewed in conjunction with the National Land Cover Database to identify developed areas and associated infrastructure that may be at risk of potential groundwater emergence flooding. Study results indicate that the groundwater emergence flood hazard is highest in coastal areas and near surface water where the water table is close to ground surface. Inland areas away from surface waterbodies are not likely to be exposed to groundwater emergence flooding. For Long Island, in the scenario with higher sea-level position, a greater groundwater emergence flood hazard is calculated for some locations closer to the coast and where land is submerged. Away from the coast and surface-water drainage, the groundwater emergence flood hazard is similar between the current average sea-level condition and the higher sea-level position scenario.

Connecticut, New York, Rhode Island↗