Groundwater-flow and land-subsidence model of Antelope Valley, California

Abstract

Antelope Valley, California, is a topographically closed basin in the western part of the Mojave Desert, about 50 miles northeast of Los Angeles. The Antelope Valley groundwater basin is about 940 square miles and is separated from the northern part of Antelope Valley by faults and low-lying hills. Prior to 1972, groundwater provided more than 90 percent of the total water supply in the valley; since 1972, it has provided between 50 and 90 percent. Most groundwater pumping in the valley occurs in the Antelope Valley groundwater basin, which includes the rapidly growing cities of Lancaster and Palmdale. Groundwater-level declines of more than 270 feet in some parts of the groundwater basin have resulted in an increase in pumping lifts, reduced well efficiency, and land subsidence of more than 6 feet in some areas. Future urban growth and limits on the supply of imported water may increase reliance on groundwater. In 2011, the Los Angeles County Superior Court of California ruled that the Antelope Valley groundwater basin is in overdraft—groundwater extractions are in excess of the Court-defined safe yield of the groundwater basin. The Court determined that the safe yield of the adjudicated area of the basin was 110,000 acre-feet per year (acre-ft/yr). Natural recharge is an important component of total groundwater recharge in Antelope Valley; however, the exact quantity and distribution of natural recharge, primarily in the form of mountain-front recharge, is uncertain, with total estimates ranging from 30,000 to 160,000 acre-ft/yr. Technical experts, retained by parties to the adjudication, used 60,000 acre-ft/yr to estimate the sustainable yield of the basin, and this value was used in this study. In order to better understand the uncertainty associated with natural recharge and to provide a tool to aid in groundwater management, a numerical model of groundwater flow and land subsidence in the Antelope Valley groundwater basin was developed using old and new geohydrologic information. The groundwater-flow system consists of three aquifers: the upper, middle, and lower aquifers. The three aquifers, which were identified on the basis of the hydrologic properties, age, and depth of the unconsolidated deposits, consist of gravel, sand, silt, and clay alluvial deposits and clay and silty clay lacustrine deposits. Prior to groundwater development in the valley, recharge was primarily the infiltration of runoff from the surrounding mountains. Groundwater flowed from the recharge areas to discharge areas around the playas where it discharged from the aquifer system as either evapotranspiration or from springs. Partial barriers to horizontal groundwater flow, such as faults, have been identified in the groundwater basin. Water-level declines owing to groundwater development have eliminated the natural sources of discharge, and pumping for agricultural and urban uses have become the primary source of discharge from the groundwater system. Infiltration of return flow from agricultural irrigation has become an important source of recharge to the aquifer system. The groundwater-flow model of the basin was discretized horizontally into a grid of 130 rows and 118 columns of square cells 1 kilometer (0.621 mile) on a side, and vertically into four layers representing the upper (two layers), middle (one layer), and lower (one layer) aquifers. Faults that were thought to act as horizontal-flow barriers were simulated in the model. The model was calibrated to simulate steady-state conditions, represented by 1915 water levels and transient-state conditions during 1915–95, by using water-level and subsidence data. Initial estimates of the aquifer-system properties and stresses were obtained from a previously published numerical model of the Antelope Valley groundwater basin; estimates also were obtained from recently collected hydrologic data and from results of simulations of groundwater-flow and land-subsidence models of the Edwards Air Force Base area. Some of these initial estimates were modified during model calibration. Groundwater pumpage for agriculture was estimated on the basis of irrigated crop acreage and crop consumptive-use data. Pumpage for public supply, which is metered, was compiled and entered into a database used for this study. Estimated annual agricultural pumpage peaked at 395,000 acre-feet (acre-ft) in 1951 and then declined because of declining agricultural production. Recharge from irrigation return flows was assumed to be 30 percent of agricultural pumpage; delays associated with return flow moving through the unsaturated zone were also simulated. The annual quantity of mountain-front recharge initially was based on estimates from previous studies. The model was calibrated using the PEST software suite; prior information from the area was incorporated through the use of Tikhonov regularization. During model calibration, the estimated mountain-front recharge was reduced from the previous estimate of 30,300 acre-ft/yr to 29,150 acre-ft/yr. Results of the simulations using the calibrated model indicate that simulated groundwater pumpage exceeded recharge in most years, resulting in an estimated cumulative depletion in groundwater storage of 8,700,000 acre-ft during the transient-simulation period (1915–2005). About 15,000,000 acre-ft of cumulative groundwater pumpage was simulated during the transient-simulation period (1915–2005), reaching a maximum rate of about 400,000 acre-ft/yr in 1951. Groundwater pumpage resulted in simulated hydraulic heads declining by more than 150 feet (ft) compared to 1915 conditions in agricultural areas. The decline in hydraulic head in the groundwater basin is the result of this depletion of groundwater storage. In turn, the simulated decline in hydraulic head in the groundwater basin has resulted in the decrease in natural discharge from the basin and has caused compaction of aquitards, resulting in land subsidence. The areal distribution of total simulated land subsidence for 2005, after about 90 years of groundwater development, indicates that land subsidence occurred throughout almost the entire Lancaster subbasin, with a maximum of about 9.4 ft in the central and eastern parts of the subbasin. An important objective of this study was to systematically address the uncertainty in estimates of natural recharge and related aquifer parameters by using the groundwater-flow and land-subsidence model with observational data and expert knowledge. After the model was calibrated to the observations and a reasonable parameter set obtained, the parameter null space—parameter values that do not appreciably affect the model calibration but may have importance for prediction—was identified. The effect of parameter uncertainty on the estimation of mountain-front recharge was addressed using the Null-Space Monte Carlo method. The Pareto trade-off method of visualizing uncertainty was also used to portray the reasonableness of larger natural-recharge rates. Results indicate that the total mountain-front recharge likely ranges between 28,000 and 44,000 acre-ft/yr, which is appreciably less than published estimates of 60,000 acre-ft/yr. Additionally, expected errors associated with agricultural pumpage estimates used in this study were found to have relatively little effect on the estimates of mountain-front recharge, reflecting the difficulty in increasing recharge through manipulation of other components of the water budget. The calibrated model was used to simulate the response of the aquifer to potential future pumping scenarios: (1) no change in the distribution of pumpage, or status quo; (2) redistribution of pumpage; and (3) artificial recharge. All three of these scenarios specify a total pumpage throughout the Antelope Valley of 110,000 acre-ft/yr according to the safe yield value ruled by the Los Angeles County Superior Court of California. This reduction in groundwater pumpage is assumed uniform throughout the basin, based on a 10-percent reduction of the total pumpage in 2005 to achieve the 110,000 acre-ft/yr level. The calibrated Antelope Valley groundwater-flow and land-subsidence model was used to simulate the hydrologic effects of the three groundwater-management scenarios during a 50-year period by using the reduced, temporally constant, pumpage distribution. Results from the first scenario indicated that the total drawdown observed since predevelopment would continue, with values exceeding 325 ft near Palmdale; consequently, land subsidence would also continue, with additional subsidence (since 2005) exceeding 3 ft in the central part of the Lancaster subbasin. The second scenario evaluated redistributing pumpage from areas in the Lancaster subbasin where simulated hydraulic-head declines were the greatest to areas where declines were smallest. Neither a formal optimization algorithm nor water-rights allocations were considered when redistributing the pumpage. Results indicated that hydraulic heads near Palmdale, where the pumpage was reduced, would recover by about 200 ft compared to 2005 conditions, with only 30 ft of additional drawdown in the northwestern part of the Lancaster subbasin, where the pumpage was increased. The magnitude of the simulated additional land subsidence decreased slightly compared to the first, status quo, scenario but land subsidence continued to be simulated throughout most of the northern part of the Lancaster subbasin. The third scenario consisted of two artificial-recharge simulations along the Upper Amargosa Creek channel and at a site located north of Antelope Buttes. Results indicate that applying artificial recharge at these sites would yield continued drawdowns and associated land subsidence. However, the magnitudes of drawdown and subsidence would be smaller than those simulated in the status quo scenario, indicating that artificial-recharge operations in the Antelope Valley could be expected to reduce the magnitude and extent of continued water-level declines and associated land subsidence.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Adam J. Siade, Tracy Nishikawa, Diane L. Rewis, Peter Martin, Steven P. Phillips. 2014. Groundwater-flow and land-subsidence model of Antelope Valley, California. https://doi.org/10.3133/sir20145166

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

Slip tendency and dilation tendency of Quaternary faults in the Great Basin region, Arizona, California, Idaho, Nevada, Oregon, Utah, and Wyoming

This report presents the results of slip tendency and dilation tendency analysis of Quaternary faults in the Great Basin region, in the states of Arizona, California, Idaho, Nevada, Oregon, Utah, and Wyoming. This effort was undertaken as part of two studies: the U.S. Department of Energy Geothermal Technologies Office-funded Innovative Geothermal Exploration through Novel Investigations of Undiscovered Systems (INGENIOUS) project, which is a multidisciplinary, multi-institution effort to develop new methodologies and best practices to accelerate the discovery of new, commercially viable hydrothermal resources; and the U.S. Geological Survey Geothermal Resources Investigations Project. The goal of this work is to identify faults and fault segments that are appropriately oriented to be stress-loaded for slip or to dilate under the ambient stress conditions. Both conditions may make such faults more likely to host permeability and fluid flow relative to other faults in the region. Slip tendency and dilation tendency were calculated for all fault segments in the study area from the U.S. Geological Survey Quaternary Fault and Fold Database. Results demonstrate that faults with high slip tendency and dilation tendency are common in the Great Basin region. The areas containing many high slip tendency and dilation tendency fault segments are associated with high strain rates. These areas also host a relatively high proportion of the known hydrothermal systems. This indicates that faults with high slip tendency and dilation tendency in areas with high strain-rate are potentially most prospective for hosting hydrothermal systems. The database published in coordination with this report contains the slip tendency and dilation tendency results data, including the fault geometry and stress data used to calculate these quantities, for both the Great Basin study area and the smaller INGENIOUS study area.

Arizona, California, Idaho, Nevada, Oregon, Utah, ↗

A spatial analysis of the groundwater emergence flood hazard in Long Island, New York, and coastal areas surrounding Long Island Sound in New York, Connecticut, and Rhode Island

Long Island, New York, and nearby coastal areas surrounding Long Island Sound are densely populated and, like other coastal areas, are susceptible to flooding from several potential sources, including stormwater from precipitation events, tidal flooding and storm surge, and groundwater emergence flooding. Groundwater emergence fooding refers to the intersection of a rising water table with land surface or critical infrastructure. Many studies of flood drivers either neglect or only briefly discuss how shallow groundwater conditions may contribute to or exacerbate flood conditions. As a part of a comprehensive study of compound flood hazards in the coastal areas of Long Island and Long Island Sound, a spatial analysis was completed by the U.S. Geological Survey, in cooperation with the Environmental Protection Agency’s Long Island Sound Partnership, formerly called the Long Island Sound Study, using available regional datasets to characterize the potential hazard for groundwater emergence flooding. The approximately 3,100 square mile study area was subdivided into 11,407 grid cells that were 900 meters by 900 meters (approximately 3,000 feet by 3,000 feet), for the purpose of integrating the spatial datasets to calculate and map the groundwater emergence flood hazard. The depth to the water table, hydrologic soil groups, and National Land Cover Database were harmonized to the common grid. A groundwater emergence flood hazard score was calculated for each grid cell for current average conditions following a set of rules accounting for the depth to the water table and the percentage of area within each cell with slow infiltrating soils. A scenario with a higher sea-level position was also calculated for the Long Island part of the study area. The calculated groundwater emergence flood hazard score was reviewed in conjunction with the National Land Cover Database to identify developed areas and associated infrastructure that may be at risk of potential groundwater emergence flooding. Study results indicate that the groundwater emergence flood hazard is highest in coastal areas and near surface water where the water table is close to ground surface. Inland areas away from surface waterbodies are not likely to be exposed to groundwater emergence flooding. For Long Island, in the scenario with higher sea-level position, a greater groundwater emergence flood hazard is calculated for some locations closer to the coast and where land is submerged. Away from the coast and surface-water drainage, the groundwater emergence flood hazard is similar between the current average sea-level condition and the higher sea-level position scenario.

Connecticut, New York, Rhode Island↗

Streamflow assessment of Birch Creek, southern boundary of the Blackfeet Indian Reservation, Pondera County, northwestern Montana—Synoptic and continuous streamflow measurements through 2022

The U.S. Geological Survey, in cooperation with the Blackfeet Water Department, performed this study to assist water-resource managers in understanding and quantifying irrigation diversions, instream flows, and the spatial and temporal streamflow dynamics of Birch Creek in northwestern Montana. Birch Creek forms the southernmost boundary of the Blackfeet Indian Reservation and is highly valued culturally as an aquatic life and wildlife resource and as a principal source of water for irrigation. The study area included Birch Creek from Swift Dam to 53.3 miles downstream just above its confluence with the Two Medicine River. The study period was calendar year 2022, but selected historical information was also included in the study. Birch Creek streamflow originates through releases from Swift Reservoir, with the largest releases typically occurring during the irrigation season (May–October) to primarily meet the needs of downstream irrigators. This study included the compilation and collection of (1) continuous streamflow measured at streamgages installed for this study, (2) instantaneous streamflow measurements made during four synoptic events, and (3) reported daily values of Swift Reservoir outflow and irrigation diversions. Continuous streamflow data were available from two U.S. Geological Survey streamgages: Birch Creek below Heart Butte Road, near Heart Butte, Montana (upper streamgage; station 06094900), at river mile 12.9 and Birch Creek at Bullhead Bridge near Valier, Mont. (lower streamgage; station 06098120), at river mile 53.3. The upper streamgage (station 06094900) was primarily affected by the regulated releases from Swift Dam with daily mean streamflow typically slightly higher than the reported Swift Reservoir outflows. Daily mean streamflow ranged from 9.87 cubic feet per second (ft 3 /s) (November 18, 2022) to 640 ft 3 /s (June 22, 2022) during September 16, 2021–December 31, 2022. The mean annual streamflow was 122 ft 3 /s in water year 2022 (a water year is the 12-month period from October 1 to September 30 and is designated by the year in which it ends), about 13 percent greater than the mean annual reported Swift Reservoir outflows. The lower streamgage (station 06098120) was downstream from all major tributaries and diversions within the Birch Creek drainage basin. Daily mean streamflow ranged from 6.02 ft 3 /s (September 8, 2022) to 95.0 ft 3 /s (June 5, 2021) during August 26, 2020–December 31, 2022. Mean annual streamflow was 27.8 ft 3 /s for water year 2022. Flows at the lower streamgage (station 06098120) were typically lower than at the upper streamgage (station 06094900) from late April to early October, whereas flows from early October to late spring were similar to or greater than those at the upper streamgage. The upper streamgage had a total streamflow volume of 87,960 acre-feet (acre-ft) for water year 2022, whereas the lower streamgage had a total streamflow of 20,357 acre-ft. A net volume of about 67,603 acre-ft was removed from Birch Creek through diversions, losses to groundwater, and evapotranspiration along that reach during water year 2022. Most of the changes in main-stem streamflow could be accounted for by the tributary inflows or diversion outflows. The most dynamic streamflow gains and losses occurred along the upper few miles of Birch Creek. Streamflow was consistently lost to the groundwater system immediately below Swift Dam and then returned to levels that slightly exceeded the outflow at the dam near river mile 11.0. The overall net gains for the entire 53.3-mile study reach ranged from 15.5 to 42.6 ft 3 /s among the synoptic events. On several occasions, streamflow fell below minimum instream flow conditions specified in the Blackfeet Compact (water rights compact among the Blackfeet Tribe, State of Montana, and United States), which are subject to a 15-year deferral period (until June 12, 2033). Notably, a section of Birch Creek immediately downstream from Swift Dam was completely dry during the October 18, 2022, synoptic event.

Montana↗