Geology Reports⌕ Search

USGS · sir20075287

Analysis of Dissolved Selenium Loading for Selected Sites in the Lower Gunnison River Basin, Colorado, 1978-2005

Abstract

Elevated selenium concentrations in streams are a water-quality concern in western Colorado. The U.S. Geologic Survey, in cooperation with the Colorado Department of Public Health and Environment, summarized selenium loading in the Lower Gunnison River Basin to support the development of total maximum daily selenium loads at sites that represent the cumulative contribution to U.S. Environmental Protection Agency 303(d) list segments. Analysis of selenium loading included quantifying loads and determining the amount of load that would need to be reduced to bring the site into compliance, referred to as 'the load reduction,' with the State chronic aquatic-life standard for dissolved selenium [85th percentile selenium concentration not to exceed 4.6 ?g/L (micrograms per liter)], referred to as 'the water-quality standard.' Streamflow and selenium concentration data for 54 historical water-quality/water-quantity monitoring sites were compiled from U.S. Geological Survey and Colorado Department of Public Health and Environment data sources. Three methods were used for analysis of selenium concentration data to address the variable data density among sites. Mean annual selenium loads were determined for only 10 of the 54 sites due to data availability limitations. Twenty-two sites had 85th percentile selenium concentrations that exceeded the water-quality standard, 3 sites had 85th percentile selenium concentrations less than the State standard, and 29 sites could not be evaluated with respect to 85th percentile selenium concentration (sample count less than 5). To bring selenium concentrations into compliance with the water-quality standard, more than 80 percent of the mean annual selenium load would need to be reduced at Red Rock Canyon, Dry Cedar Creek, Cedar Creek, Loutzenhizer Arroyo, Sunflower Drain, and Whitewater Creek. More than 50 percent of the mean annual load would need to be reduced at Dry Creek to bring the site into compliance with the water-quality standard. The Uncompahgre River, Gunnison River at Delta, and Gunnison River near Grand Junction would require 69, 34 and 53 percent, respectively, of the mean annual load to be reduced for water years 2001 through 2005 to meet the water-quality standard. Mean annual load reductions can be further reduced by targeting the periods of time when selenium would be removed from streams by remediation. During a previous study of selenium loads in the Lower Gunnison River Basin, mean annual load reductions were estimated at the Gunnison River near Grand Junction for the 1997?2001 study period. Mean annual load reductions estimated for this study period were less than those estimated for the 2001?05 study period, emphasizing the importance of understanding that different study periods can result in different load reduction estimates.

Explore related subjects

90° N90° S · 180° W ← longitude → 180° E
Source-reported bounding extent: 37.916666666666664° to 39.083333333333336° latitude; -109° to -107° longitude. This indicates report coverage, not an exact sampling location. View area on OpenStreetMap.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Judith C. Thomas, Kenneth J. Leib, John W. Mayo. 2008. Analysis of Dissolved Selenium Loading for Selected Sites in the Lower Gunnison River Basin, Colorado, 1978-2005. https://doi.org/10.3133/sir20075287

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

Baseline water-quality inventory and summary for the Paterson Great Falls National Historical Park, New Jersey

The Paterson Great Falls National Historical Park (PAGR), established in 2011 in the City of Paterson, New Jersey, contains many cultural, historical, and natural resources. Because of the PAGR’s young age and limited resources, a long record of natural resource data is not available for use to guide future park management and planning decisions. A detailed natural resource inventory was identified as an immediate need in the “Foundation Document—Paterson Great Falls National Historical Park,” given the history of extensive industrial activity throughout the PAGR and the Passaic River Basin. The U.S. Geological Survey, in cooperation with the National Park Service and the Urban Waters Federal Partnership for the Lower Passaic River, inventoried water-quality monitoring efforts and compiled historical water-quality data from secondary data sources to define baseline conditions in the PAGR and the surrounding study area. This report documents the methods used to harmonize water-quality data aggregated from multiple sources for the PAGR study area. Procedures implemented during data harmonization include compiling data from multiple sources, assessing the dataset for completeness, addressing metadata concerns, and creating a consistent and quality-assured dataset for future analysis. The harmonized dataset contains 14 aggregated surface-water sites, 1,103 individual sampling days, and 32,000 water-quality records throughout the period of record defined for this study (1952–2021). Summary statistics and comparison to water-quality criteria are provided for focus parameters that can support PAGR management, including field properties, suspended material, total dissolved solids, specific conductance, chloride, sulfate, Escherichia coli, nutrients, contaminants of concern related to fish consumption advisories, and litter and floatable debris. A spatial data gap was identified for the recreational area near the base of the Great Falls and immediately downstream from a known combined sewer overflow discharge location. Analytic data gaps were identified for continuous streamflow and water-quality parameters, floatable debris characterization, and harmful algal blooms identification. Continuous collection of contaminants of concern was identified as a temporal data gap, as these parameters were not consistently collected within the study area. The water-quality data synthesis and summary presented in this report can assist PAGR staff in understanding the complex baseline water resources within the study area and can serve as a baseline to design future water-quality monitoring efforts and evaluate changes in water quality over time. The harmonized dataset, as well as future New Jersey Department of Environmental Protection and New Jersey Harbor Discharge Group monitoring data and assessments, can also be used to examine the status and trends in surface-water quality, support compliance with the Clean Water Act (33 U.S.C. 1251 et seq.), and further investigate changes to park water resources that can affect ecological and human health.

New Jersey↗

Slip tendency and dilation tendency of Quaternary faults in the Great Basin region, Arizona, California, Idaho, Nevada, Oregon, Utah, and Wyoming

This report presents the results of slip tendency and dilation tendency analysis of Quaternary faults in the Great Basin region, in the states of Arizona, California, Idaho, Nevada, Oregon, Utah, and Wyoming. This effort was undertaken as part of two studies: the U.S. Department of Energy Geothermal Technologies Office-funded Innovative Geothermal Exploration through Novel Investigations of Undiscovered Systems (INGENIOUS) project, which is a multidisciplinary, multi-institution effort to develop new methodologies and best practices to accelerate the discovery of new, commercially viable hydrothermal resources; and the U.S. Geological Survey Geothermal Resources Investigations Project. The goal of this work is to identify faults and fault segments that are appropriately oriented to be stress-loaded for slip or to dilate under the ambient stress conditions. Both conditions may make such faults more likely to host permeability and fluid flow relative to other faults in the region. Slip tendency and dilation tendency were calculated for all fault segments in the study area from the U.S. Geological Survey Quaternary Fault and Fold Database. Results demonstrate that faults with high slip tendency and dilation tendency are common in the Great Basin region. The areas containing many high slip tendency and dilation tendency fault segments are associated with high strain rates. These areas also host a relatively high proportion of the known hydrothermal systems. This indicates that faults with high slip tendency and dilation tendency in areas with high strain-rate are potentially most prospective for hosting hydrothermal systems. The database published in coordination with this report contains the slip tendency and dilation tendency results data, including the fault geometry and stress data used to calculate these quantities, for both the Great Basin study area and the smaller INGENIOUS study area.

Arizona, California, Idaho, Nevada, Oregon, Utah, ↗

A spatial analysis of the groundwater emergence flood hazard in Long Island, New York, and coastal areas surrounding Long Island Sound in New York, Connecticut, and Rhode Island

Long Island, New York, and nearby coastal areas surrounding Long Island Sound are densely populated and, like other coastal areas, are susceptible to flooding from several potential sources, including stormwater from precipitation events, tidal flooding and storm surge, and groundwater emergence flooding. Groundwater emergence fooding refers to the intersection of a rising water table with land surface or critical infrastructure. Many studies of flood drivers either neglect or only briefly discuss how shallow groundwater conditions may contribute to or exacerbate flood conditions. As a part of a comprehensive study of compound flood hazards in the coastal areas of Long Island and Long Island Sound, a spatial analysis was completed by the U.S. Geological Survey, in cooperation with the Environmental Protection Agency’s Long Island Sound Partnership, formerly called the Long Island Sound Study, using available regional datasets to characterize the potential hazard for groundwater emergence flooding. The approximately 3,100 square mile study area was subdivided into 11,407 grid cells that were 900 meters by 900 meters (approximately 3,000 feet by 3,000 feet), for the purpose of integrating the spatial datasets to calculate and map the groundwater emergence flood hazard. The depth to the water table, hydrologic soil groups, and National Land Cover Database were harmonized to the common grid. A groundwater emergence flood hazard score was calculated for each grid cell for current average conditions following a set of rules accounting for the depth to the water table and the percentage of area within each cell with slow infiltrating soils. A scenario with a higher sea-level position was also calculated for the Long Island part of the study area. The calculated groundwater emergence flood hazard score was reviewed in conjunction with the National Land Cover Database to identify developed areas and associated infrastructure that may be at risk of potential groundwater emergence flooding. Study results indicate that the groundwater emergence flood hazard is highest in coastal areas and near surface water where the water table is close to ground surface. Inland areas away from surface waterbodies are not likely to be exposed to groundwater emergence flooding. For Long Island, in the scenario with higher sea-level position, a greater groundwater emergence flood hazard is calculated for some locations closer to the coast and where land is submerged. Away from the coast and surface-water drainage, the groundwater emergence flood hazard is similar between the current average sea-level condition and the higher sea-level position scenario.

Connecticut, New York, Rhode Island↗