Geology Reports⌕ Search

USGS · ofr20161003

Evaluation of the hydraulic and biological performance of the portable floating fish collector at Cougar Reservoir and Dam, Oregon, 2014

Abstract

The biological and hydraulic performance of a new portable floating fish collector (PFFC) located in a cul-de-sac within the forebay of Cougar Dam, Oregon, was evaluated during 2014. The purpose of the PFFC was to explore surface collection as a means to capture juvenile salmonids at one or more sites using a small, cost-effective, pilot-scale device. The PFFC used internal pumps to draw attraction flow over an inclined plane about 3 meters (m) deep, through a flume at a design velocity of as much as 6 feet per second (ft/s), and to empty a small amount of water and any entrained fish into a collection box. Performance of the PFFC was evaluated at 64 cubic feet per second (ft 3 /s) (Low) and 109 ft 3 /s (High) inflow rates alternated using a randomized-block schedule from May 27 to December 16, 2014. The evaluation of the biological performance was based on trap catch; behaviors, locations, and collection of juvenile Chinook salmon ( Oncorhynchus tshawytscha ) tagged with acoustic transmitters plus passive integrated transponder (PIT) tags; collection of juvenile Chinook salmon implanted with only PIT tags; and untagged fish monitored near and within the PFFC using acoustic cameras. The evaluation of hydraulic performance was based on measurements of water velocity and direction of flow in the PFFC. The PFFC collected 156 juvenile Chinook salmon and 280 individuals of other species, primarily dace (Cyprinidae) and largemouth bass ( Micropterus salmoides ). The collection included one of the 212 acoustic+PIT-tagged fish detected near the PFFC and two of the 1,505 PIT-tagged fish released near the head of the reservoir. No juvenile salmonids were collected between early July and early September when water temperatures near the water surface were greater than about 16 degrees Celsius (°C). Depths of acoustic+PIT-tagged fish indicated a preferential selection of water temperature of 13–15 °C, which was often deeper than the entrance to the PFFC, and those fish rarely were at depths with water temperatures greater than 16 °C. Dam passage of acoustic+PIT-tagged fish was similar to previous years, but much of the passage occurred prior to the date the PFFC began operation. Discovery Efficiency, the proportion of acoustic+PIT-tagged fish detected in the cul-de-sac that were within 10 m of the PFFC entrance and 0–6 m deep (the Discovery Zone), was 0.736 during the Low treatment and 0.639 during the High treatment. Entrance Efficiency, the proportion of fish in the Discovery Zone that were collected by the PFFC, was 0.007 during the Low treatment and 0.000 during the High treatment. Fish Collection Efficiency, the proportion of acoustic+PIT-tagged fish collected of those detected in the cul-de-sac, was 0.005 and 0.000 during the Low and High treatments, respectively. The areas of highest use by acoustic+PIT-tagged fish were between the stern of the PFFC and the outlet of the reservoir (a water temperature control tower), with the greatest use being near the tower. Results from untagged fish detected with acoustic cameras indicated that most fish near and within the PFFC were in the 90–250-millimeter length bin and few were less than 60 millimeters long; most fish were present during crepuscular periods; trajectories of fish outside the PFFC were rarely directed toward the entrance; and many fish entering the PFFC swam back out before they could be collected. The hydraulic performance of the PFFC did not achieve the design goals of smooth acceleration of inflow culminating in a peak water velocity of 6 ft/s and, as a result, the hydraulic performance likely contributed to the low biological performance. The greatest water velocity measured in the PFFC (1.87 ft/s) was lower than designed due at least in part to the PFFC being lower in the water column than expected. Additionally, difficulties during anchor deployment prevented placement of the PFFC as near to the reservoir outlet as planned, resulting in a PFFC position outside the prevailing flow field and known areas of high fish densities. Overall, the results indicate that location, hydraulic conditions, water temperature, and shallow depth of the entrance were among the factors contributing to the low biological performance of the PFFC in 2014.

Explore related subjects

90° N90° S · 180° W ← longitude → 180° E
Source-reported bounding extent: 44.06464670206631° to 44.132449357705454° latitude; -122.25173950195311° to -122.2071075439453° longitude. This indicates report coverage, not an exact sampling location. View area on OpenStreetMap.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

John W. Beeman, Scott D. Evans, Philip V. Haner, Hal C. Hansel, Amy C. Hansen, Gabriel S. Hansen, Tyson W. Hatton, Jamie M. Sprando, Collin D. Smith, Noah S. Adams. 2016-01-12. Evaluation of the hydraulic and biological performance of the portable floating fish collector at Cougar Reservoir and Dam, Oregon, 2014. https://doi.org/10.3133/ofr20161003

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

ECCOE Landsat quarterly calibration and validation report—Quarter 2, 2026

Executive Summary The U.S. Geological Survey Earth Resources Observation and Science Calibration and Validation (Cal/Val) Center of Excellence (ECCOE) focuses on improving the accuracy, precision, calibration, and product quality of remote-sensing data, leveraging years of multiscale optical system geometric and radiometric calibration and characterization experience. The ECCOE Landsat Cal/Val Team continually monitors the geometric and radiometric performance of active Landsat missions and makes calibration adjustments, as needed, to maintain data quality at the highest level. This report provides observed geometric and radiometric analysis results for Landsats 8 and 9 for quarter 2 (April–June), 2026. All data used to compile the Cal/Val analysis results presented in this report are freely available from the U.S. Geological Survey EarthExplorer website: https://earthexplorer.usgs.gov.

Open-File Report↗

ECCOE Landsat quarterly calibration and validation report—Quarter 1, 2026

Executive Summary The U.S. Geological Survey Earth Resources Observation and Science Calibration and Validation (Cal/Val) Center of Excellence (ECCOE) focuses on improving the accuracy, precision, calibration, and product quality of remote-sensing data, leveraging years of multiscale optical system geometric and radiometric calibration and characterization experience. The ECCOE Landsat Cal/Val Team continually monitors the geometric and radiometric performance of active Landsat missions and makes calibration adjustments, as needed, to maintain data quality at the highest level. This report provides observed geometric and radiometric analysis results for Landsats 8 and 9 for quarter 1 (January–March) of 2026. All data used to compile the Cal/Val analysis results presented in this report are freely available from the U.S. Geological Survey EarthExplorer website: https://earthexplorer.usgs.gov . One specific activity that the ECCOE Landsat Cal/Val Team closely monitored was a Landsat 8 Thermal Infrared Sensor encoder alerts anomaly. On March 18, 2026, the Thermal Infrared Sensor instrument’s mechanism control electronics board reset, driving several parameters to default power-on values. Subsequent telemetry and analysis determined that no persistent hardware misconfiguration was present and no radiometric or geometric degradation was observed.

Open-File Report↗

Floods of June 20–July 6, 2024, in the Big Sioux River, Rock River, Little Sioux River, Ocheyedan River, and Floyd River Basins, northwestern Iowa

Major flooding occurred on June 20–July 6, 2024, in northwestern Iowa affecting the Big Sioux, Rock, Little Sioux, Ocheyedan, and Floyd River Basins. Heavy rain fell in northwestern Iowa, southwestern Minnesota, and southeastern South Dakota on June 20–22, 2024. Parts of northwestern Iowa recorded 2–6 inches of rainfall and localized amounts exceeding 12 inches. A maximum peak-of-record streamflow of 175,000 cubic feet per second at the U.S. Geological Survey streamgage Big Sioux River at Akron, Iowa (06485500), was recorded on June 22, 2024, and had an annual exceedance probability range of 0.2–0.49 percent. High-water marks were measured at four locations along the Big Sioux River between U.S. Interstate 29 at Sioux City, Iowa, upstream to Iowa Highway 10 north of Hawarden, Iowa, a distance of 75.7 river miles. A maximum peak-of-record streamflow of 157,000 cubic feet per second at the U.S. Geological Survey streamgage Rock River near Rock Valley, Iowa (06483500), was recorded on June 22, 2024, and had an annual exceedance probability of less than 0.2 percent. High-water marks were measured at eight locations along the Rock River between County Road B30 east of Hudson, South Dakota, upstream to Iowa Highway 9 at Rock Rapids, Iowa, a distance of 39.3 river miles. A maximum peak-of-record streamflow of 63,000 cubic feet per second at the U.S. Geological Survey streamgage Little Sioux River at Correctionville, Iowa (06606600), was recorded on June 24, 2024, and had an annual exceedance probability range of 0.2–0.49 percent. High-water marks were measured at 11 locations along the Little Sioux River between Iowa Highway 31 west of Correctionville, Iowa, upstream to U.S. Highway 18 north of Spencer, Iowa, a distance of 134.8 river miles. A maximum streamflow of 24,500 cubic feet per second at the U.S. Geological Survey streamgage Ocheyedan River near Spencer, Iowa (06605000), was recorded on June 22, 2024, and had an annual exceedance probability range of 0.2–0.49 percent. High-water marks were measured at three locations along the Ocheyedan River between County Road M38 west of Spencer, Iowa, upstream to U.S. Highway 18 west of Everly, Iowa, a distance of 12.8 river miles. A maximum streamflow of 41,000 cubic feet per second at the U.S. Geological Survey streamgage Floyd River at Alton, Iowa (06600100), was recorded on June 22, 2024, and had an annual exceedance probability range of 1–1.99 percent. High-water marks were measured at six locations along the Floyd River between Iowa Highway 3 at Le Mars, Iowa, upstream to Iowa Highway 10 at Alton, Iowa, a distance of 27.5 river miles. The high-water marks were used to develop flood profiles for the Big Sioux, Rock, Little Sioux, Ocheyedan, and Floyd Rivers.

Iowa, Minnesota, South Dakota↗