Effects of the 2008 high-flow experiment on water quality in Lake Powell and Glen Canyon Dam releases, Utah-Arizona

Abstract

Under the direction of the Secretary of the Interior, the U.S. Geological Survey‘s Grand Canyon Monitoring and Research Center (GCMRC) conducted a high-flow experiment (HFE) at Glen Canyon Dam (GCD) from March 4 through March 9, 2008. This experiment was conducted under enriched sediment conditions in the Colorado River within Grand Canyon and was designed to rebuild sandbars, aid endangered humpback chub ( Gila cypha ), and benefit various downstream resources, including rainbow trout ( Oncorhynchus mykiss ), the aquatic food base, riparian vegetation, and archaeological sites. During the experiment, GCD discharge increased to a maximum of 1,160 m 3 /s and remained at that rate for 2.5 days by near-capacity operation of the hydroelectric powerplant at 736 m 3 /s, augmented by discharge from the river outlet works (ROW) at 424 m 3 /s. The ROW releases water from Lake Powell approximately 30 m below the powerplant penstock elevation and bypasses the powerplant turbines. During the HFE, the surface elevation of Lake Powell was reduced by 0.8 m. This report describes studies that were conducted before and after the experiment to determine the effects of the HFE on (1) the stratification in Lake Powell in the forebay immediately upstream of GCD and (2) the water quality of combined GCD releases and changes that occurred through the tailwater below the dam. The effects of the HFE to the water quality and stratigraphy in the water column of the GCD forebay and upstream locations in Lake Powell were minimal, compared to those during the beach/habitat-building flow experiment conducted in 1996, in which high releases of 1,273 m 3 /s were sustained for a 9-day period. However, during the 2008 HFE, there was evidence of increased advective transport of reservoir water at the penstock withdrawal depth and subsequent mixing of this withdrawal current with water above and below this depth. Reservoir hydrodynamics during the HFE period were largely being controlled by a winter inflow density current, which was moving through the deepest portion of the reservoir and approaching GCD near the end of the experiment. Compared to the beach/habitat-building flow experiment of 1996, the 2008 HFE had less affect on the reservoir because of the decreased volume of discharge from the dam and the different behavior of the winter inflow density current. The operation of the ROW increased the dissolved oxygen (DO) concentration of GCD releases and resulted in DO supersaturation at higher release volumes. The jets of water discharged from the ROW caused these increases. Elevated DO concentrations persisted through the tailwater of the dam to Lees Ferry. At maximum ROW operation, downstream DO concentrations increased to approximately 120 percent of saturation.

Explore related subjects

90° N90° S · 180° W ← longitude → 180° E
Source-reported bounding extent: 36.77966129375976° to 37.28054922868934° latitude; -111.63914616667464° to -110.74228148200983° longitude. This indicates report coverage, not an exact sampling location. View area on OpenStreetMap.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

William S. Vernieu. 2010. Effects of the 2008 high-flow experiment on water quality in Lake Powell and Glen Canyon Dam releases, Utah-Arizona. https://doi.org/10.3133/ofr20101159

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

ECCOE Landsat quarterly calibration and validation report—Quarter 2, 2026

Executive Summary The U.S. Geological Survey Earth Resources Observation and Science Calibration and Validation (Cal/Val) Center of Excellence (ECCOE) focuses on improving the accuracy, precision, calibration, and product quality of remote-sensing data, leveraging years of multiscale optical system geometric and radiometric calibration and characterization experience. The ECCOE Landsat Cal/Val Team continually monitors the geometric and radiometric performance of active Landsat missions and makes calibration adjustments, as needed, to maintain data quality at the highest level. This report provides observed geometric and radiometric analysis results for Landsats 8 and 9 for quarter 2 (April–June), 2026. All data used to compile the Cal/Val analysis results presented in this report are freely available from the U.S. Geological Survey EarthExplorer website: https://earthexplorer.usgs.gov.

Open-File Report↗

ECCOE Landsat quarterly calibration and validation report—Quarter 1, 2026

Executive Summary The U.S. Geological Survey Earth Resources Observation and Science Calibration and Validation (Cal/Val) Center of Excellence (ECCOE) focuses on improving the accuracy, precision, calibration, and product quality of remote-sensing data, leveraging years of multiscale optical system geometric and radiometric calibration and characterization experience. The ECCOE Landsat Cal/Val Team continually monitors the geometric and radiometric performance of active Landsat missions and makes calibration adjustments, as needed, to maintain data quality at the highest level. This report provides observed geometric and radiometric analysis results for Landsats 8 and 9 for quarter 1 (January–March) of 2026. All data used to compile the Cal/Val analysis results presented in this report are freely available from the U.S. Geological Survey EarthExplorer website: https://earthexplorer.usgs.gov . One specific activity that the ECCOE Landsat Cal/Val Team closely monitored was a Landsat 8 Thermal Infrared Sensor encoder alerts anomaly. On March 18, 2026, the Thermal Infrared Sensor instrument’s mechanism control electronics board reset, driving several parameters to default power-on values. Subsequent telemetry and analysis determined that no persistent hardware misconfiguration was present and no radiometric or geometric degradation was observed.

Open-File Report↗

Floods of June 20–July 6, 2024, in the Big Sioux River, Rock River, Little Sioux River, Ocheyedan River, and Floyd River Basins, northwestern Iowa

Major flooding occurred on June 20–July 6, 2024, in northwestern Iowa affecting the Big Sioux, Rock, Little Sioux, Ocheyedan, and Floyd River Basins. Heavy rain fell in northwestern Iowa, southwestern Minnesota, and southeastern South Dakota on June 20–22, 2024. Parts of northwestern Iowa recorded 2–6 inches of rainfall and localized amounts exceeding 12 inches. A maximum peak-of-record streamflow of 175,000 cubic feet per second at the U.S. Geological Survey streamgage Big Sioux River at Akron, Iowa (06485500), was recorded on June 22, 2024, and had an annual exceedance probability range of 0.2–0.49 percent. High-water marks were measured at four locations along the Big Sioux River between U.S. Interstate 29 at Sioux City, Iowa, upstream to Iowa Highway 10 north of Hawarden, Iowa, a distance of 75.7 river miles. A maximum peak-of-record streamflow of 157,000 cubic feet per second at the U.S. Geological Survey streamgage Rock River near Rock Valley, Iowa (06483500), was recorded on June 22, 2024, and had an annual exceedance probability of less than 0.2 percent. High-water marks were measured at eight locations along the Rock River between County Road B30 east of Hudson, South Dakota, upstream to Iowa Highway 9 at Rock Rapids, Iowa, a distance of 39.3 river miles. A maximum peak-of-record streamflow of 63,000 cubic feet per second at the U.S. Geological Survey streamgage Little Sioux River at Correctionville, Iowa (06606600), was recorded on June 24, 2024, and had an annual exceedance probability range of 0.2–0.49 percent. High-water marks were measured at 11 locations along the Little Sioux River between Iowa Highway 31 west of Correctionville, Iowa, upstream to U.S. Highway 18 north of Spencer, Iowa, a distance of 134.8 river miles. A maximum streamflow of 24,500 cubic feet per second at the U.S. Geological Survey streamgage Ocheyedan River near Spencer, Iowa (06605000), was recorded on June 22, 2024, and had an annual exceedance probability range of 0.2–0.49 percent. High-water marks were measured at three locations along the Ocheyedan River between County Road M38 west of Spencer, Iowa, upstream to U.S. Highway 18 west of Everly, Iowa, a distance of 12.8 river miles. A maximum streamflow of 41,000 cubic feet per second at the U.S. Geological Survey streamgage Floyd River at Alton, Iowa (06600100), was recorded on June 22, 2024, and had an annual exceedance probability range of 1–1.99 percent. High-water marks were measured at six locations along the Floyd River between Iowa Highway 3 at Le Mars, Iowa, upstream to Iowa Highway 10 at Alton, Iowa, a distance of 27.5 river miles. The high-water marks were used to develop flood profiles for the Big Sioux, Rock, Little Sioux, Ocheyedan, and Floyd Rivers.

Iowa, Minnesota, South Dakota↗