Geology Reports⌕ Search

USGS · ofr0171

Quality-assurance data for routine water quality analyses by the U. S. Geological Survey laboratory in Troy, New York; July 1993 through June 1995

Abstract

A laboratory for analysis of low-ionic strength water has been developed at the U.S. Geological Survey (USGS) office in Troy, N.Y., to analyze samples collected by USGS projects in the Northeast. The laboratory's quality-assurance program is based on internal and interlaboratory quality-assurance samples and quality-control procedures developed to ensure proper sample collection, processing, and analysis. The quality-assurance/quality-control data are stored in the laboratory's SAS data-management system, which provides efficient review, compilation, and plotting of quality-assurance/quality-control data. This report presents and discusses samples analyzed from July 1993 through June 1995. Quality-control results for 18 analytical procedures were evaluated for bias and precision. Control charts show that data from seven of the analytical procedures were biased throughout the analysis period for either high-concentration or low-concentration samples but were within control limits; these procedures were: acid-neutralizing capacity, dissolved inorganic carbon, dissolved organic carbon (soil expulsions), chloride, magnesium, nitrate (colorimetric method), and pH. Three of the analytical procedures were occasionally biased but were within control limits; they were: calcium (high for high-concentration samples for May 1995), dissolved organic carbon (high for highconcentration samples from January through September 1994), and fluoride (high in samples for April and June 1994). No quality-control sample has been developed for the organic monomeric aluminum procedure. Results from the filter-blank and analytical-blank analyses indicate that all analytical procedures in which blanks were run were within control limits, although values for a few blanks were outside the control limits. Blanks were not analyzed for acid-neutralizing capacity, dissolved inorganic carbon, fluoride, nitrate (colorimetric method), or pH. Sampling and analysis precision are evaluated herein in terms of the coefficient of variation obtained for triplicate samples in 14 of the 18 procedures. Data-quality objectives were met by more than 90 percent of the samples analyzed in all procedures except total monomeric aluminum (85 percent of samples met objectives), total aluminum (70 percent of samples met objectives), and dissolved organic carbon (85 percent of samples met objectives). Triplicate samples were not analyzed for ammonium, fluoride, dissolved inorganic carbon, or nitrate (colorimetric method). Results of the USGS interlaboratory Standard Reference Sample Program indicated high data quality with a median result of 3.6 of a possible 4.0. Environment Canada's LRTAP interlaboratory study results indicated that more than 85 percent of the samples met data-quality objectives in 6 of the 12 analyses; exceptions were calcium, dissolved organic carbon, chloride, pH, potassium, and sodium. Data-quality objectives were not met for calcium samples in one LRTAP study, but 94 percent of samples analyzed were within control limits for the remaining studies. Data-quality objectives were not met by 35 percent of samples analyzed for dissolved organic carbon, but 94 percent of sample values were within 20 percent of the most probable value. Data-quality objectives were not met for 30 percent of samples analyzed for chloride, but 90 percent of sample values were within 20 percent of the most probable value. Measurements of samples with a pH above 6.0 were biased high in 54 percent of the samples, although 85 percent of the samples met data-quality objectives for pH measurements below 6.0. Data-quality objectives for potassium and sodium were not met in one study (only 33 percent of the samples analyzed met the objectives), although 85 percent of the sample values were within control limits for the other studies. Measured sodium values were above the upper control limit in all studies. Results from blind reference-sample analyses indicated that data

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Tricia A. Lincoln, Debra A. Horan-Ross, Michael R. McHale, Gregory B. Lawrence. 2001. Quality-assurance data for routine water quality analyses by the U. S. Geological Survey laboratory in Troy, New York; July 1993 through June 1995. https://doi.org/10.3133/ofr0171

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

ECCOE Landsat quarterly calibration and validation report—Quarter 2, 2026

Executive Summary The U.S. Geological Survey Earth Resources Observation and Science Calibration and Validation (Cal/Val) Center of Excellence (ECCOE) focuses on improving the accuracy, precision, calibration, and product quality of remote-sensing data, leveraging years of multiscale optical system geometric and radiometric calibration and characterization experience. The ECCOE Landsat Cal/Val Team continually monitors the geometric and radiometric performance of active Landsat missions and makes calibration adjustments, as needed, to maintain data quality at the highest level. This report provides observed geometric and radiometric analysis results for Landsats 8 and 9 for quarter 2 (April–June), 2026. All data used to compile the Cal/Val analysis results presented in this report are freely available from the U.S. Geological Survey EarthExplorer website: https://earthexplorer.usgs.gov.

Open-File Report↗

ECCOE Landsat quarterly calibration and validation report—Quarter 1, 2026

Executive Summary The U.S. Geological Survey Earth Resources Observation and Science Calibration and Validation (Cal/Val) Center of Excellence (ECCOE) focuses on improving the accuracy, precision, calibration, and product quality of remote-sensing data, leveraging years of multiscale optical system geometric and radiometric calibration and characterization experience. The ECCOE Landsat Cal/Val Team continually monitors the geometric and radiometric performance of active Landsat missions and makes calibration adjustments, as needed, to maintain data quality at the highest level. This report provides observed geometric and radiometric analysis results for Landsats 8 and 9 for quarter 1 (January–March) of 2026. All data used to compile the Cal/Val analysis results presented in this report are freely available from the U.S. Geological Survey EarthExplorer website: https://earthexplorer.usgs.gov . One specific activity that the ECCOE Landsat Cal/Val Team closely monitored was a Landsat 8 Thermal Infrared Sensor encoder alerts anomaly. On March 18, 2026, the Thermal Infrared Sensor instrument’s mechanism control electronics board reset, driving several parameters to default power-on values. Subsequent telemetry and analysis determined that no persistent hardware misconfiguration was present and no radiometric or geometric degradation was observed.

Open-File Report↗

Floods of June 20–July 6, 2024, in the Big Sioux River, Rock River, Little Sioux River, Ocheyedan River, and Floyd River Basins, northwestern Iowa

Major flooding occurred on June 20–July 6, 2024, in northwestern Iowa affecting the Big Sioux, Rock, Little Sioux, Ocheyedan, and Floyd River Basins. Heavy rain fell in northwestern Iowa, southwestern Minnesota, and southeastern South Dakota on June 20–22, 2024. Parts of northwestern Iowa recorded 2–6 inches of rainfall and localized amounts exceeding 12 inches. A maximum peak-of-record streamflow of 175,000 cubic feet per second at the U.S. Geological Survey streamgage Big Sioux River at Akron, Iowa (06485500), was recorded on June 22, 2024, and had an annual exceedance probability range of 0.2–0.49 percent. High-water marks were measured at four locations along the Big Sioux River between U.S. Interstate 29 at Sioux City, Iowa, upstream to Iowa Highway 10 north of Hawarden, Iowa, a distance of 75.7 river miles. A maximum peak-of-record streamflow of 157,000 cubic feet per second at the U.S. Geological Survey streamgage Rock River near Rock Valley, Iowa (06483500), was recorded on June 22, 2024, and had an annual exceedance probability of less than 0.2 percent. High-water marks were measured at eight locations along the Rock River between County Road B30 east of Hudson, South Dakota, upstream to Iowa Highway 9 at Rock Rapids, Iowa, a distance of 39.3 river miles. A maximum peak-of-record streamflow of 63,000 cubic feet per second at the U.S. Geological Survey streamgage Little Sioux River at Correctionville, Iowa (06606600), was recorded on June 24, 2024, and had an annual exceedance probability range of 0.2–0.49 percent. High-water marks were measured at 11 locations along the Little Sioux River between Iowa Highway 31 west of Correctionville, Iowa, upstream to U.S. Highway 18 north of Spencer, Iowa, a distance of 134.8 river miles. A maximum streamflow of 24,500 cubic feet per second at the U.S. Geological Survey streamgage Ocheyedan River near Spencer, Iowa (06605000), was recorded on June 22, 2024, and had an annual exceedance probability range of 0.2–0.49 percent. High-water marks were measured at three locations along the Ocheyedan River between County Road M38 west of Spencer, Iowa, upstream to U.S. Highway 18 west of Everly, Iowa, a distance of 12.8 river miles. A maximum streamflow of 41,000 cubic feet per second at the U.S. Geological Survey streamgage Floyd River at Alton, Iowa (06600100), was recorded on June 22, 2024, and had an annual exceedance probability range of 1–1.99 percent. High-water marks were measured at six locations along the Floyd River between Iowa Highway 3 at Le Mars, Iowa, upstream to Iowa Highway 10 at Alton, Iowa, a distance of 27.5 river miles. The high-water marks were used to develop flood profiles for the Big Sioux, Rock, Little Sioux, Ocheyedan, and Floyd Rivers.

Iowa, Minnesota, South Dakota↗