Geology ReportsSearch

USGS · 70227624

A borehole test for chlorinated solvent diffusion and degradation rates in sedimentary rock

Abstract

We present a new field measurement and numerical interpretation method (combined termed ‘test’) to parameterize the diffusion of trichloroethene (TCE) and its biodegradation products (DPs) from the matrix of sedimentary rock. The method uses a dual-packer system to interrogate a low-permeability section of the rock matrix adjacent to a previously contaminated borehole and uses the borehole monitoring history to establish the pre-test condition. TCE and its DPs are removed from the groundwater between the packers at the onset of the testing. The parameters estimated by fitting a radial diffusion model to the concentration history and borehole concentration data, also termed back-diffusion, are the tortuosity factor and sorption coefficients of TCE and DPs in the rock matrix and the TCE and DP biodegradation rate coefficients in the borehole. We demonstrate the equipment design and the interpretive method using a borehole accessing the grey mudstone at a TCE contaminated site in the Newark Basin. In this test, both nonreactive (bromide) and reactive (trichlorofluoroethene) tracers are used to constrain the estimated parameters; however, the bromide tracer was not needed to estimate the parameters in this test. The parameters estimated from the field test are consistent with values measured independently in laboratory experiments using field samples of similar lithology. From the interpretation, we compute the TCE and DP concentration distributions in the rock matrix prior to the test to illustrate how the results can be used to enhance understanding of contaminant distribution in the rock matrix.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Richelle M. Allen-King, Rebecca L. Kiekhaefer, Daniel J. Goode, Paul A. Hsieh, Michelle M. Lorah, Thomas E. Imbrigiotta. 2022-01-29. A borehole test for chlorinated solvent diffusion and degradation rates in sedimentary rock. https://doi.org/10.1111/gwmr.12495

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

A Monte-Carlo chemical budget approach to assess ambient groundwater flow in bedrock open boreholes

In low-permeability rocks, ambient groundwater flow in open boreholes may go undetected using conventional borehole-flowmeter tools and alternative approaches may be needed to identify flow. Understanding ambient flow in open boreholes is important for tracking of cross contamination in groundwater. Chlorinated volatile organic compound (CVOC) concentrations from three open boreholes set in a crystalline-rock aquifer (two of three open boreholes) and a siltstone aquifer (one of three open boreholes) were examined using a new approach and associated software program called the AFCE (Aqueous-Flow-Concentration-Estimator). The program allows comparison of coupled chemical datasets through a Monte-Carlo simulation and a chemical-budget approach to assess ambient groundwater flow in open boreholes. The coupled datasets required for the comparison include aqueous CVOC concentrations from groundwater samples from (1) discrete fractures, such as those measured from temporary deployment of straddle-borehole packer assemblies; and (2) the concentration of the open borehole (wellbore) water, as measured by a vertical profile of passive samplers from within the same open borehole. Because results from the passive samplers represent a composite mixture of the results from the discrete samples under ambient groundwater-flow conditions, potentially at unknown proportions, the comparison between coupled datasets affords the ability to discern likely water contributions of CVOC from discrete fractures (or fracture zones), and which fractures may be dominating the water chemistry of the open borehole.

Groundwater Monitoring and Remediation

Theory, construction and operation of simple tensiometers

The tensiometer, introduced by Richards and Gardner (1936) has been a tool often ignored in unsaturated zone investigations. Hazardous waste disposal studies that require values of unsaturated zone matric potentials will expand tensiometer use. Familiarity with operation and installation principles is necessary to ensure quality data collection. The essential elements of a tensiometer are a porous cup connected with tubing to a vacuum gauge; all are filled with water. When the porous cup is buried in unsaturated soil, the soil draws water through the cup wall, until the water tension inside the cup equals the surrounding soil-water tension. The tension is transmitted through the water filled tube to an accessible vacuum gauge (manometer or transducer) and is recorded manually or automatically. Although specialized tensiometers exist, the tensiometer presented here in detail is suited to diverse on-site applications. Constructed from readily available, inexpensive parts, it can measure as much as 0.85 bar of tension. Design features include a flushing system for removal of entrapped air or mercury, and an easily maintained modular network of nylon manometers and water-supply tubes. Good hydraulic connection between porous cup and soil and meticulous backfill procedures are necessary for accurate measurement of representative matric potentials. Proper and consistent use of tensiometers should yield reliable values of matric potentials, and lead to a better understanding of unsaturated zone processes.

Groundwater Monitoring and Remediation