Landsat 8 thermal infrared sensor scene select mechanism open loop operations

Abstract

The Landsat 8 (L8) spacecraft and its two instruments, the operational land imager (OLI) and thermal infrared sensor (TIRS), have been consistently characterized and calibrated since its launch in February 2013. These performance metrics and calibration updates are determined through the United States Geological Survey (USGS) Landsat image assessment system (IAS), which has been performing this function since its launch. The TIRS on-orbit geometric calibration procedures in-clude TIRS-to-OLI alignment, TIRS sensor chip assembly (SCA) alignment, and TIRS band align-ment. In December 2014, the TIRS instrument experienced an anomalous condition related to the instrument’s ability to accurately measure the location of the scene select mechanism (SSM). The SSM is a rotating mirror that allows the instrument’s field of view to be pointed at the Earth, for normal imaging, or at either deep space or an onboard black body, for radiometric calibration purposes. This anomalous condition in the SSM’s position sensor made it necessary to implement a new mode of operation for this mirror, termed mode-0. Mode-0 involves operating the mirror in an open-loop control state during normal mission operations when acquiring Earth data. Closed-loop mode-4 is needed for directing the mirror towards the radiometric calibration targets and is used approximately once every two weeks to collect radiometric calibration data. Mode-0 is used for most operational imaging because it does not require SSM encoder data, thereby allowing the SSM en-coder electronics to remain unpowered most of the time, reducing its use throughout the lifetime of the TIRS instrument, thus helping to preserve its nominal behavior during it use. This paper dis-cusses the geometric calibration of the SSM mirror during its current normal mode-0 set of image operations, as its open-loop control allows the mirror to drift over time in its uncontrolled state and its impacts on products. The results shown in this paper demonstrate that the ability to have on-going updates to the modeling of the TIRS SSM mirror model, in both an automated fashion and with a set of more manual operations, allows accuracy that approaches mode-4 results within days from the start of a mode-0 event.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Michael J. Choate, R. Rengarajan, James C. Storey, Tim Beckmann. 2021-02-09. Landsat 8 thermal infrared sensor scene select mechanism open loop operations. https://doi.org/10.3390/rs13040617

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

Harmonizing the Landsat ground reference with the Sentinel-2 Global Reference Image using space-based bundle adjustment

There is an ever-increasing need to use accurate and consistent geometric ground reference in the processing of remotely sensed data products as it reduces the burden on the end-users to account for the differences between the data products from different missions. In this regard, United States Geological Survey (USGS) initiated an effort to harmonize the Landsat ground reference with the Sentinel-2 Global Reference Image (GRI) to improve the co-registration between the data products of the two global medium-resolution missions. In this paper, we have discussed the process, results, and the improvements expected from this harmonization of two ground references using space-triangulation based bundle adjustment techniques. The ground coordinates of the Landsat reference library, consisting of 5 million Ground Control Points (GCPs) were adjusted in a series of four simultaneous bundle block adjustments using thousands of Landsat-8 (L8) scenes anchored with more than 300,000 control points extracted from the GRI dataset. The net adjustments to each of the four blocks, namely, Australia, Americas, Eurasia, and Islands, varied anywhere from 1 m to 13 m, depending on the accuracy of the GCPs in these blocks. The use of the GRI dataset in our bundle adjustment not only improved the absolute accuracy of the Landsat ground reference but will also improve the co-registration between Sentinel-2 and Landsat terrain corrected products, as the European Space Agency plans to process the Sentinel-2 products using the GRI dataset. Independent validation of the Landsat products processed using harmonized GCPs with the GRI dataset indicated a global mis-registration error of less than 8 m Circular Error Probable at 90 % (CE90), an improvement from 25 meters prior to harmonization. The improvements to the Landsat products using the harmonized GCPs will be available to the public as part of Landsat Collection-2 processing by the end of 2020.

MDPI Remote Sensing