Geology ReportsSearch

USGS · 70218181

Kovats and lee retention indices determined by gas chromatography/mass spectrometry for organic compounds of environmental interest

Abstract

Retention indices of standard organic compounds of environmental interest were determined by gas chromatography/mass spectrometry, using a DB‐5 fused‐silica capillary column. Retention indices are useful references for tentative compound identification by gas chromatography, or confirmation by gas chromatography/mass spectrometry. They provide elution order for isomers that might be indistinguishable based on mass spectra. Modified Kovats and Lee retention indices are given for polycyclic aromatic hydrocarbons; sulfur heterocycles; nitrogen heterocycles; aromatic amines; oxygen heterocycles; phenols; alcohols; ketones; alkanes; nitriles; and methylesters of fatty, dicarboxylic, and aromatic acids for comparison and reference. Retention index values for heterocycles by gas chromatography/mass spectrometry are comparable with gas chromatography values previously reported.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Colleen E. Rostad, Wilfred E. Pereira. 2005-04-09. Kovats and lee retention indices determined by gas chromatography/mass spectrometry for organic compounds of environmental interest. https://doi.org/10.1002/jhrc.1240090603

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

Monitoring sea lamprey pheromones and their degradation using rapid stream-side extraction coupled with UPLC-MS/MS

Pheromones guide adult sea lamprey (Petromyzon marinus) to suitable spawning streams and mates, and therefore, when quantified, can be used to assess population size and guide management. Here, we present an efficient sample preparation method where 100 mL of river water was spiked with deuterated pheromone as an internal standard and underwent rapid field-based SPE and elution in the field. The combination of field extraction with laboratory UPLC-MS/MS reduced the sample consumption from 1 to 0.1 L, decreased the sample process time from more than 1 h to 10 min, and increased the precision and accuracy. The sensitivity was improved more than one order of magnitude compared with the previous method. The influences of experimental conditions were assessed to optimize the separation and peak shapes. The analytical method has been validated by studies of stability, selectivity, precision, and linearity and by the determination of the limits of detection and quantification. The method was used to quantify pheromone concentration from five streams tributary to Lake Ontario and to estimate that the environmental half-life of 3kPZS is about 26 h.

Journal of Separation Science