Geology ReportsSearch

USGS · 70210778

Hydrodynamic modeling results showing the effects of the Luce Bayou interbasin transfer on salinity in Lake Houston, TX

Abstract

An overreliance on groundwater resources in the Houston (Texas) metropolitan area led to aquifer drawdowns and land subsidence, so regional water suppliers have been turning to surface water resources to meet water demand. Lake Houston, an important water supply reservoir 24 kilometers (15 miles) northeast of downtown Houston, requires new water supply sources to continue to meet water supply demands for the next several decades. The upcoming Luce Bayou Interbasin Transfer Project will divert up to 500 million gallons per day of Trinity River water into Lake Houston. Trinity River water has significantly different water quality than the Lake Houston tributaries. To evaluate the project’s potential effect on water quality, the U.S. Geological Survey used an enhanced version of a previously released Lake Houston hydrodynamic model. With a focus on salinity and water-surface elevations, the model combined data from 2009 to 2017 with simulated flow from the Luce Bayou Interbasin Transfer to evaluate potential outcomes from three hypothetical flow scenarios. Overall, these scenarios found that the Luce Bayou Interbasin Transfer would cause salinities to moderately rise over most of the modeled time (2009–2017), although salinities were buffered under 2011 drought conditions. Large inflow events equalized salinities under baseline conditions as well as the enhanced flow scenarios.

Explore related subjects

90° N90° S · 180° W ← longitude → 180° E
Source-reported bounding extent: 29.91090055463952° to 30.148392924428762° latitude; -95.24940490722656° to -95.0126838684082° longitude. This indicates report coverage, not an exact sampling location. View area on OpenStreetMap.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Erik A. Smith, Sachin D. Shah. 2020-06-23. Hydrodynamic modeling results showing the effects of the Luce Bayou interbasin transfer on salinity in Lake Houston, TX. https://doi.org/10.21423/twj.v11i1.7094

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

Discrete streamflow measurements and waterborne self-potential logging of a 43-kilometer-long reach of the Elm Fork Trinity River upstream from Dallas, Texas

Continuous and discrete streamflow data were combined with waterborne self-potential (WaSP), surface-water temperature and surface-water conductivity surveys obtained along an approximately 43-kilometer (26.7 mile) surveyed reach of the Elm Fork Trinity River (hereinafter referred to as “Elm Fork”) upstream from Dallas, Texas, to investigate areas of gaining and losing streamflow under various streamflow and seasonal climatic conditions. Discrete streamflow measurements were made at 17 locations on October 12, 2021, and January 25, 2022, at 19 locations on May 17, 2022, and at 18 locations on August 9, 2022. WaSP data were measured from a kayak in January 2022 during a period of base flow along three individually surveyed reaches between the Lake Lewisville Dam and Frasier Dam on the Elm Fork. Together, these data indicated different parts of the Elm Fork functioned as either a gaining or losing stream depending on streamflow and seasonal climatic conditions. Overall, there were estimated net gains in streamflow during the first two discrete-measurement events of about 107 cubic feet per second (ft 3 /s) and 2 ft 3 /s in October 2021 and January 2022, respectively, and estimated net losses in streamflow in May 2022 and August 2022 of about 24 ft 3 /s and 18 ft 3 /s, respectively.

Texas

The use of historical data and global climate models to assess historical and future surface water and groundwater availability in the Trinity River Basin in Texas

This paper describes the results of a study that was done by the USGS to assess recent (2017) water availability, forecast long-term trends in water availability, assess changes in water availability, and forecast future water availability in the Trinity River Basin in Texas. The Trinity River Basin surface water model and Trinity River alluvium aquifer (TRAA) groundwater model were created to evaluate future conditions under different global climate models (GCM). The results of this study show minimal overall changes in water availability for both surface water and groundwater. Trend analyses using historical data (1900–2017) indicated an increase of annual precipitation on the watersheds that drain into the reservoirs in Regional Water Planning Group C. However, the Trinity River Basin surface water model GCM ensemble mean annual precipitation indicates a downward trend, resulting in a downward trend in surface runoff. Additionally, the GCM ensemble mean for the Trinity River Basin surface water model and the TRAA groundwater model both indicate a downward trend in recharge while the TRAA model GCM ensemble mean indicates an upward trend in the amount of groundwater leaving the aquifer to rivers and streams resulting in an upward trend of cumulative storage change.

Texas

Floods in Central Texas, September 7-14, 2010

Severe flooding occurred near the Austin metropolitan area in central Texas September 7–14, 2010, because of heavy rainfall associated with Tropical Storm Hermine. The U.S. Geological Survey, in cooperation with the Upper Brushy Creek Water Control and Improvement District, determined rainfall amounts and annual exceedance probabilities for rainfall resulting in flooding in Bell, Williamson, and Travis counties in central Texas during September 2010. We documented peak streamflows and the annual exceedance probabilities for peak streamflows recorded at several streamflow-gaging stations in the study area. The 24-hour rainfall total exceeded 12 inches at some locations, with one report of 14.57 inches at Lake Georgetown. Rainfall probabilities were estimated using previously published depth-duration frequency maps for Texas. At 4 sites in Williamson County, the 24-hour rainfall had an annual exceedance probability of 0.002. Streamflow measurement data and flood-peak data from U.S. Geological Survey surface-water monitoring stations (streamflow and reservoir gaging stations) are presented, along with a comparison of September 2010 flood peaks to previous known maximums in the periods of record. Annual exceedance probabilities for peak streamflow were computed for 20 streamflow-gaging stations based on an analysis of streamflow-gaging station records. The annual exceedance probability was 0.03 for the September 2010 peak streamflow at the Geological Survey's streamflow-gaging stations 08104700 North Fork San Gabriel River near Georgetown, Texas, and 08154700 Bull Creek at Loop 360 near Austin, Texas. The annual exceedance probability was 0.02 for the peak streamflow for Geological Survey's streamflow-gaging station 08104500 Little River near Little River, Texas. The lack of similarity in the annual exceedance probabilities computed for precipitation and streamflow might be attributed to the small areal extent of the heaviest rainfall over these and the other gaged watersheds.

Texas