Geology ReportsSearch

USGS · 70145057

Isotopic disproportionation during hydrogen isotopic analysis of nitrogen-bearing organic compounds

Abstract

Rationale High-precision hydrogen isotope ratio analysis of nitrogen-bearing organic materials using high-temperature conversion (HTC) techniques has proven troublesome in the past. Formation of reaction products other than molecular hydrogen (H 2 ) has been suspected as a possible cause of incomplete H 2 yield and hydrogen isotopic fractionation. Methods The classical HTC reactor setup and a modified version including elemental chromium, both operated at temperatures in excess of 1400 °C, have been compared using a selection of nitrogen-bearing organic compounds, including caffeine. A focus of the experiments was to avoid or suppress hydrogen cyanide (HCN) formation and to reach quantitative H 2 yields. The technique also was optimized to provide acceptable sample throughput. Results The classical HTC reaction of a number of selected compounds exhibited H 2 yields from 60 to 90 %. Yields close to 100 % were measured for the experiments with the chromium-enhanced reactor. The δ 2 H values also were substantially different between the two types of experiments. For the majority of the compounds studied, a highly significant relationship was observed between the amount of missing H 2 and the number of nitrogen atoms in the molecules, suggesting the pyrolytic formation of HCN as a byproduct. A similar linear relationship was found between the amount of missing H 2 and the observed hydrogen isotopic result, reflecting isotopic fractionation. Conclusions The classical HTC technique to produce H 2 from organic materials using high temperatures in the presence of glassy carbon is not suitable for nitrogen-bearing compounds. Adding chromium to the reaction zone improves the yield to 100 % in most cases. The initial formation of HCN is accompanied by a strong hydrogen isotope effect, with the observed hydrogen isotope results on H 2 being substantially shifted to more negative δ 2 H values. The reaction can be understood as an initial disproportionation leading to H 2 and HCN with the HCN-hydrogen systematically enriched in 2 H by more than 50 ‰. In the reaction of HCN with chromium, H 2 and chromium-containing solid residues are formed quantitatively.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Sreejesh Nair, Heike Geilmann, Tyler B. Coplen, Haiping Qi, Matthias Gehre, Arndt Schimmelmann, Willi A. Brand. 2015-03-26. Isotopic disproportionation during hydrogen isotopic analysis of nitrogen-bearing organic compounds. https://doi.org/10.1002/rcm.7174

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

Reaffirming the consistency of the original stock of NBS 19 limestone and its byproduct with finer grain size for δ13C and δ18O calibrations—Both distributed internationally

Rationale Approximately 3–4 kg of NBS 19 limestone, prepared in 1982 by the U.S. Geological Survey (USGS), serves as a primary reference for the carbon isotope scales VPDB and VPDB-LSVEC and the oxygen isotope scale VPDB. Its consensus values are +1.95‰ for δ 13 C and −2.2‰ for δ 18 O measurements. After more than three decades of distribution, the number of units labeled “NBS 19” shrunk substantially, and the remaining material was quarantined, with a small fraction retained at the USGS and a larger fraction entrusted to the International Atomic Energy Agency (IAEA) for secure storage. Given the critical role of NBS 19, verifying the integrity of its δ 13 C and δ 18 O values across these storage locations is essential. Method Samples from IAEA and USGS stock materials were selected to ensure traceability of carbon and oxygen isotopes to NBS 19 distribution units from various storage locations. To achieve this, distribution units labeled as NBS 19 from both the IAEA and the National Institute of Standards and Technology (NIST) were included. During evaluation, two distinct grain sizes were identified within these units. Grain size was assessed using sieves on five selected samples. The δ 13 C and δ 18 O values of finer and coarser fractions (both labeled NBS 19) were measured at USGS using continuous-flow isotope-ratio mass spectrometry on 100- and 200-μg samples. Results Expanded 95% measurement uncertainties ( k = 2) for δ 13 C and δ 18 O determinations are 0.027‰ and 0.038‰ or better, respectively, for quarantined NBS 19 stocks and finer byproduct calcite, which we term “NBS-19 byproduct,” regardless of storage location. Between the 1990s and circa 2011, NBS-19 byproduct labeled “NBS 19,” distributed by NIST and the IAEA, shows these findings. Conclusions NBS 19 primary isotopic reference material should be used for calibration of new isotopic reference materials rather than NBS-19 byproduct secondary isotopic reference material.

Rapid Communications in Mass Spectrometry

Three new calcium formate reference materials for δ13C measurements and a redetermination of the R(13C/12C) ratio for VPDB based on proton nuclear magnetic resonance measurements

Rationale Isotope ratio mass spectrometry (IRMS) and proton nuclear magnetic resonance ( 1 H NMR) spectroscopy are independent techniques for determining the isotope ratio R ( 13 C/ 12 C) in organic compounds. However, the lack of suitable reference materials has limited intercalibration of results from these methods. Methods Three high-purity calcium formate isotopic reference materials were developed, each ideal for accurate isotope ratio measurements by both 1 H NMR and isotope-ratio mass spectrometry (IRMS). For each material, R ( 13 C/ 12 C) was determined by 1 H NMR, and the relative isotope abundance ( δ 13 C VPDB-LSVEC ) by IRMS. The combined IRMS and NMR results were used to determine the R ( 13 C/ 12 C) value of Vienna Peedee belemnite (VPDB). Results The combined datasets yield a value for R ( 13 C/ 12 C) of 0.0111050 ± 0.0000047 ( k = 2) for VPDB, which is 6.7‰ lower than the commonly cited value of 0.011180, but similar to other recent determinations. These three calcium formate reference materials exhibit high accuracy across both analytical methods and provide robust tools for instrument calibration, method validation, and inter-laboratory comparison in carbon stable isotope ratio analysis. Conclusions An accurate R ( 13 C/ 12 C) value for VPDB strengthens the link between relative ( δ 13 C VPDB-LSVEC ) values from IRMS and R ( 13 C/ 12 C) isotope ratios from NMR and other techniques. These three calcium formate isotopic reference materials (USGS106, USGS107, and USGS108) are available from the US Geological Survey and provide reference materials for calibration, method validation, and inter-laboratory comparison in carbon isotope ratio analysis.

Rapid Communications in Mass Spectrometry

Correction to “Stable isotope reference materials and scale definitions – outcomes of the 2024 IAEA experts meeting”

This article corrects the following: Camin, F., Besic, D., Brewer, P., Allison, C., Coplen, T., Dunn, P., Gehre, M., Gröning, M., Meijer, H.-A.-J, Hélie, J.-F., Iacumin, P., Kraft, R., Krajnc, B., Kümmel, S., Lee, S., Meija, J., Mester, Z., Mohn, J., Moossen, H., Qi, H., Skrzypek, G., Sperlich, P., Viallon, J., Wassenaar, L. and Wielgosz, R. (2025). Stable Isotope Reference Materials and Scale Definitions—Outcomes of the 2024 IAEA Experts Meeting. Rapid Commun Mass Spectrom, 39: e10018, https://doi.org/10.1002/rcm.10018. In the above article, the text of note 3 in Section 4.2 is incorrect. The correct text is shown below: 3. Whilst limited amounts of the original VSMOW and SLAP scale-defining reference materials may still be available, to enable continuous wide distribution of RMs for VSMOW-SLAP scale realization (normalization, calibration) the scale-maintaining reference materials VSMOW2 and SLAP2 are available. VSMOW2 and SLAP2 have δ(18O) values identical to VSMOW and SLAP, respectively, but with an uncertainty with respect to VSMOW and SLAP. We apologize for this error. The CIAAW-IUPAC endorsed all isotope delta scale definitions appearing in Camin et al. (2025) and agreed to publish the current and all future updates and corrections to these definitions on its website (www.ciaaw.org).

Rapid Communications in Mass Spectrometry