Geology ReportsSearch

USGS · 70042445

The role of adsorbed water on the friction of a layer of submicron particles

Abstract

Anomalously low values of friction observed in layers of submicron particles deformed in simple shear at high slip velocities are explained as the consequence of a one nanometer thick layer of water adsorbed on the particles. The observed transition from normal friction with an apparent coefficient near μ = 0.6 at low slip speeds to a coefficient near μ = 0.3 at higher slip speeds is attributed to competition between the time required to extrude the water layer from between neighboring particles in a force chain and the average lifetime of the chain. At low slip speeds the time required for extrusion is less than the average lifetime of a chain so the particles make contact and lock. As slip speed increases, the average lifetime of a chain decreases until it is less than the extrusion time and the particles in a force chain never come into direct contact. If the adsorbed water layer enables the otherwise rough particles to rotate, the coefficient of friction will drop to μ = 0.3, appropriate for rotating spheres. At the highest slip speeds particle temperatures rise above 100°C, the water layer vaporizes, the particles contact and lock, and the coefficient of friction rises to μ = 0.6. The observed onset of weakening at slip speeds near 0.001 m/s is consistent with the measured viscosity of a 1 nm thick layer of adsorbed water, with a minimum particle radius of approximately 20 nm, and with reasonable assumptions about the distribution of force chains guided by experimental observation. The reduction of friction and the range of velocities over which it occurs decrease with increasing normal stress, as predicted by the model. Moreover, the analysis predicts that this high-speed weakening mechanism should operate only for particles with radii smaller than approximately 1 μm. For larger particles the slip speed required for weakening is so large that frictional heating will evaporate the adsorbed water and weakening will not occur.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Charles G. Sammis, David A. Lockner, Ze’ev Reches. 2011-05-27. The role of adsorbed water on the friction of a layer of submicron particles. https://doi.org/10.1007/s00024-011-0324-0

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

Local variations in broadband sensor installations: Orientations, sensitivities, and noise levels

As seismologists continue to place more stringent demands on data quality, accurately described metadata are becoming increasingly important. In order to better constrain the orientation and sensitivities of seismometers deployed in U.S. Geological Survey networks, the Albuquerque Seismological Laboratory (ASL) has recently begun identifying true north with a fiber optic gyroscope (FOG) and has developed methodologies to constrain mid-band, vertical component sensitivity levels to less than 1% in a controlled environment. However, questions remain regarding the accuracy of this new alignment technique as well as if instrument sensitivities and background noise levels are stable when the seismometers are installed in different environmental settings. In this study, we examine the stability and repeatability of these parameters by reinstalling two high-quality broadband seismometers (Streckeisen STS-2.5 and Nanometrics T-360 Global Seismographic Network (GSN) version) at different locations around the ASL and comparing them to each other and a reference STS-6 seismometer that stayed stationary for the duration of the experiment. We find that even in different environmental conditions, the sensitivities of the two broadband seismometers stayed stable to within 0.1% and that orientations attained using the FOG are generally accurate to within a degree. However, one install was off by 5° due to a mistake made by the installation team. These results indicate that while technology and methodologies are now in place to calibrate and orient a seismometer to within 1°, human error both during the installation and while producing the metadata is often a limiting factor. Finally, we find that background noise levels at short periods (0.1–1 s) become noisier when the sensors are emplaced in unconsolidated materials, whereas the noise levels at long periods (30–100 s) are not sensitive to local geological structure on the vertical components.

Pure and Applied Geophysics

Inter-source interferometry of seismic body waves: Required conditions and examples

Seismic interferometry is widely applied to retrieve wavefields propagating between receivers. Another version of seismic interferometry, called inter-source interferometry, uses the principles of seismic reciprocity and expands interferometric applications to retrieve waves that propagate between two seismic sources. Previous studies of inter-source interferometry usually involve surface-wave and coda-wave estimations. We use inter-source interferometry to estimate the P-waves propagating between two sources rather than the estimation of surface waves and coda waves. We show that the recovered arrival times are dependent on the accuracy of the earthquake catalog of the two sources. Using inter-source interferometry, one can recover the waveform of the direct body waves and potentially reconstruct the waveform of coda waves, depending on the source-receiver geometry. The retrieval of these waveforms is accurate only when the wavefield is sampled with approximately 4 receivers per wavelength in the stationary phase zone. We show that using only receivers inside the stationary phase region for inter-source interferometry introduces the phase error of approximately 0.3 radians. In our study, we show an example of the P-wavefield reconstruction between two earthquakes using the seismic records from an array along San Andreas Fault. The retrieved P waves give a qualitative estimation of the thickness of the low-velocity zone of San Andreas Fault of approximately 4 km.

Pure and Applied Geophysics