Geology ReportsSearch

USGS · 70034170

High-frequency filtering of strong-motion records

Abstract

The influence of noise in strong-motion records is most problematic at low and high frequencies where the signal to noise ratio is commonly low compared to that in the mid-spectrum. The impact of low-frequency noise (<1 Hz) on strong-motion intensity parameters such as ground velocities, displacements and response spectral ordinates can be dramatic and consequentially it has become standard practice to low-cut (high-pass) filter strong-motion data with corner frequencies often chosen based on the shape of Fourier amplitude spectra and the signal-to-noise ratio. It has been shown that response spectral ordinates should not be used beyond some fraction of the corner period (reciprocal of the corner frequency) of the low-cut filter. This article examines the effect of high-frequency noise (>5 Hz) on computed pseudo-absolute response spectral accelerations (PSAs). In contrast to the case of low-frequency noise our analysis shows that filtering to remove high-frequency noise is only necessary in certain situations and that PSAs can often be used up to 100 Hz even if much lower high-cut corner frequencies are required to remove the noise. This apparent contradiction can be explained by the fact that PSAs are often controlled by ground accelerations associated with much lower frequencies than the natural frequency of the oscillator because path and site attenuation (often modelled by Q and κ, respectively) have removed the highest frequencies. We demonstrate that if high-cut filters are to be used, then their corner frequencies should be selected on an individual basis, as has been done in a few recent studies.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J. Douglas, D.M. Boore. 2010-09-16. High-frequency filtering of strong-motion records. https://doi.org/10.1007/s10518-010-9208-4

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

Hazard-consistent seismic losses and collapse capacities for light-frame wood buildings in California and Cascadia

We evaluate the seismic performance of modern seismically designed wood light-frame (WLF) buildings, considering regional seismic hazard characteristics that influence ground motion duration and frequency content and, thus, seismic risk. Results show that WLF building response correlates strongly with ground motion spectral shape but weakly with duration. Due to the flatter spectral shape of ground motions from subduction events, WLF buildings at sites affected by these earthquakes may experience double the economic losses for a given intensity of shaking, and collapse capacities may be reduced by up to 50%, compared to those at sites affected by crustal earthquakes. These differences could motivate significant increases in design values at sites affected by subduction earthquakes to achieve the uniform risk targets of the American Society of Civil Engineers (ASCE) 7 standard.

Alaska, California, Oregon Washington

Response study of a 51-story-tall Los Angeles, California building inferred from motions of the Mw7.1 July 5, 2019 Ridgecrest, California earthquake

A 51-story building in downtown Los Angeles that is equipped with a seismic monitoring accelerometric array recorded the Mw7.1 Ridgecrest, California earthquake of July 5, 2019. The building is a dual-core reinforced-concrete shear-wall and perimeter-column structure with ~ 80% of floors constructed as post-tensioned flat slabs, which makes it a trending design. Using system identification methods, spectral analyses, and coherence-phase angle computations, the recorded response data allowed the identification of dynamic response characteristics (fundamental frequencies of [NS] 0.21 Hz, [EW] 0.28 Hz, and [Torsional] 0.45 Hz, critical damping percentages < 2.5%, and associated mode shapes), as well as computation of drift ratios with maximum peaks of 0.145% for both NS and EW directions. The critical damping percentages are consistent with those recommended by LATBSDC ( 2017 ). There is no indication from the records that post-tensioned slab design played any role in altering the dynamic characteristics.

California

Experimental evaluation of four ground-motion scaling methods for dynamic response-history analysis of nonlinear structures

This paper experimentally evaluates four methods to scale earthquake ground-motions within an ensemble of records to minimize the statistical dispersion and maximize the accuracy in the dynamic peak roof drift demand and peak inter-story drift demand estimates from response-history analyses of nonlinear building structures. The scaling methods that are investigated are based on: (1) ASCE/SEI 7–10 guidelines; (2) spectral acceleration at the fundamental (first mode) period of the structure, S a ( T 1 ); (3) maximum incremental velocity, MIV ; and (4) modal pushover analysis. A total of 720 shake-table tests of four small-scale nonlinear building frame specimens with different static and dynamic characteristics are conducted. The peak displacement demands from full suites of 36 near-fault ground-motion records as well as from smaller “unbiased” and “biased” design subsets (bins) of ground-motions are included. Out of the four scaling methods, ground-motions scaled to the median MIV of the ensemble resulted in the smallest dispersion in the peak roof and inter-story drift demands. Scaling based on MIV also provided the most accurate median demands as compared with the “benchmark” demands for structures with greater nonlinearity; however, this accuracy was reduced for structures exhibiting reduced nonlinearity. The modal pushover-based scaling (MPS) procedure was the only method to conservatively overestimate the median drift demands.

Bulletin of Earthquake Engineering