Geology ReportsSearch

USGS · 70030328

Analytical validation of a real-time reverse transcription polymerase chain reaction test for Pan-American lineage H7 subtype Avian influenza viruses

Abstract

A real-time reverse transcription polymerase chain reaction test for the identification of the H7 subtype in North American Avian influenza viruses (AIVs) was first reported in 2002; however, recent AIV surveillance efforts in wild birds and H7 outbreaks in poultry demonstrated that the 2002 test did not detect all H7 AIVs present in North and South America. Therefore, a new test, the 2008 Pan-American H7 test, was developed by using recently available H7 nucleotide sequences. The analytical specificity of the new assay was characterized with an RNA panel composed of 19 H7 viruses from around the world and RNA from all hemagglutinin subtypes except H16. Specificity for North and South American lineage H7 viruses was observed. Assay limits of detection were determined to be between 103 and 104 gene copies per reaction with in vitro transcribed RNA, and 100.0 and 10 0.8 50% egg infectious doses per reaction. The 2008 Pan-American H7 test also was shown to perform similarly to the 2002 test with specimens from chickens experimentally exposed to A/Chicken/BritishColumbia/314514-2/04 H7N3 highly pathogenic AIV. Furthermore, the 2008 test was able to detect 100% (n = 27) of the H7 AIV isolates recovered from North American wild birds in a 2006-2007 sample set (none of which were detected by the 2002 H7 test).

Explore related subjects

90° N90° S · 180° W ← longitude → 180° E
Source-reported bounding extent: -55.6118° to 83.5491° latitude; -171.7317° to -12.2086° longitude. This indicates report coverage, not an exact sampling location. View area on OpenStreetMap.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Erica Spackman, Hon S. Ip, D.L. Suarez, R.D. Slemons, D.E. Stallknecht. 2008-09-01. Analytical validation of a real-time reverse transcription polymerase chain reaction test for Pan-American lineage H7 subtype Avian influenza viruses. https://doi.org/10.1177/104063870802000512

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

Laboratory assessment for recovery of porcine circovirus 2 and porcine reproductive and respiratory syndrome virus using two types of commercially available hollow-fiber ultrafilters

Groundwater near swine farms is an uninvestigated reservoir for porcine reproductive and respiratory syndrome virus (PRRSV) and porcine circoviruses (PCVs). Enteric microorganisms are often collected from groundwater via dead-end ultrafiltration, but recovery of PRRSV and PCV with this method has not been assessed. We recovered PRRSV2 and PCV2 by dead-end ultrafiltration followed by polyethylene glycol (PEG) precipitation, nucleic acid extraction, and reverse-transcription quantitative real-time PCR. We also compared 2 commercial hemodialysis ultrafilters (Asahi Kasei Rexeed-25A, Nipro Elisio-25H) and compared PRRSV2 recovery in these filters to other waterborne microorganisms. On average, 8 ± 1% of PRRSV2 was recovered by dead-end ultrafiltration and PEG precipitation, compared to 25 ± 6% for adenovirus 41. Full-process recovery of bacteria in the same filters was 5–15%; Cryptosporidium parvum recovery was 42 ± 12%. PCV2 was detected in 4 of 12 replicate filters, but low stock concentrations precluded quantitative recovery estimates. Elisio-25H ultrafilters performed similarly to Rexeed-25A filters for all organisms tested and is an effective replacement for the Rexeed-25A, which is no longer available in the United States. Our recovery of PRRSV2 and PCV2 by dead-end ultrafiltration in the laboratory suggests that PRRSV2 detection limits are as low as 3–50 genomic copies/L in sample volumes of 100–1,500 L. Based on quantitative microbial risk assessment, these concentrations are relevant to PRRSV2 infection rates in the U.S. swine herd.

Journal of Veterinary Diagnostic Investigation

Retrospective review of the pathology of American pikas

American pikas ( Ochotona princeps ) are small lagomorphs that live in mountainous talus areas of western North America. Studies on the histopathology of American pikas are limited. We summarize here the clinical histories, and gross and histologic findings of 12 American pikas, including 9 captive (wild-caught) and 3 wild animals. Death was often attributed to stress (transport, handling, anesthesia) with few-to-no premonitory clinical signs. Infection was the cause of death in 2 cases: 1 had bacterial pyogranulomatous dermatitis, cellulitis, and lymphadenitis with sepsis; the other case had oomycete-induced necrotizing colitis. Incidental parasitic infections included sarcocystosis, nematodosis (oxyurids), and ectoparasitism. Most animals with adequate nutritional status had periportal hepatic lipidosis; this finding was absent in all animals with adipose atrophy, and it is possible that periportal hepatic lipidosis is non-pathologic in American pikas. Three cases had myocardial necrosis that was considered the cause of death; the cause of necrosis was not determined, but it may have been caused by stress or vitamin E–selenium deficiency. Esophageal hyperkeratosis was noted in animals with a history of anorexia and negative energy balance; accumulation of esophageal keratin can result from lack of mucosal abrasion by ingesta. Several histologic findings that are likely normal in American pikas include splenic extramedullary hematopoiesis, thymic tissue in adults, and Clostridium sp. in the enteric lumen.

Journal of Veterinary Diagnostic Investigation

Second round of an interlaboratory comparison of SARS-CoV2 molecular detection assays used by 45 veterinary diagnostic laboratories in the United States

The COVID-19 pandemic presents a continued public health challenge. Veterinary diagnostic laboratories in the United States use RT-rtPCR for animal testing, and many laboratories are certified for testing human samples; hence, ensuring that laboratories have sensitive and specific SARS-CoV2 testing methods is a critical component of the pandemic response. In 2020, the FDA Veterinary Laboratory Investigation and Response Network (Vet-LIRN) led an interlaboratory comparison (ILC1) to help laboratories evaluate their existing RT-rtPCR methods for detecting SARS-CoV2. All participating laboratories were able to detect the viral RNA spiked in buffer and PrimeStore molecular transport medium (MTM). With ILC2, Vet-LIRN extended ILC1 by evaluating analytical sensitivity and specificity of the methods used by participating laboratories to detect 3 SARS-CoV2 variants (B.1; B.1.1.7 [Alpha]; B.1.351 [Beta]) at various copy levels. We analyzed 57 sets of results from 45 laboratories qualitatively and quantitatively according to the principles of ISO 16140-2:2016. More than 95% of analysts detected the SARS-CoV2 RNA in MTM at ≥500 copies for all 3 variants. In addition, for nucleocapsid markers N1 and N2, 81% and 92% of the analysts detected ≤20 copies in the assays, respectively. The analytical specificity of the evaluated methods was >99%. Participating laboratories were able to assess their current method performance, identify possible limitations, and recognize method strengths as part of a continuous learning environment to support the critical need for the reliable diagnosis of COVID-19 in potentially infected animals and humans.

Journal of Veterinary Diagnostic Investigation