Robowell is an automated process for monitoring selected ground water quality properties and constituents by pumping a well or multilevel sampler. Robowell was developed and tested to provide a cost-effective monitoring system that meets protocols expected for manual sampling. The process uses commercially available electronics, instrumentation, and hardware, so it can be configured to monitor ground water quality using the equipment, purge protocol, and monitoring well design most appropriate for the monitoring site and the contaminants of interest. A Robowell prototype was installed on a sewage treatment plant infiltration bed that overlies a well-studied unconfined sand and gravel aquifer at the Massachusetts Military Reservation, Cape Cod, Massachusetts, during a time when two distinct plumes of constituents were released. The prototype was operated from May 10 to November 13, 1996, and quality-assurance/quality-control measurements demonstrated that the data obtained by the automated method was equivalent to data obtained by manual sampling methods using the same sampling protocols. Water level, specific conductance, pH, water temperature, dissolved oxygen, and dissolved ammonium were monitored by the prototype as the wells were purged according to U.S Geological Survey (USGS) ground water sampling protocols. Remote access to the data record, via phone modem communications, indicated the arrival of each plume over a few days and the subsequent geochemical reactions over the following weeks. Real-time availability of the monitoring record provided the information needed to initiate manual sampling efforts in response to changes in measured ground water quality, which proved the method and characterized the screened portion of the plume in detail through time. The methods and the case study described are presented to document the process for future use.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

G.E. Granato, K.P. Smith. 2007-02-22. Robowell: An automated process for monitoring ground water quality using established sampling protocols. https://doi.org/10.1111/j.1745-6592.1999.tb00243.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

Understanding the evolution of groundwater-contaminant plume chemistry emanating from legacy contaminant sources: An example from a long-term crude oil spill

Understanding the evolution of plumes emanating from residual hydrocarbon contaminant sources requires evaluating how changes in source compositions over time cause changes in dissolved plume chemistry as residual sources age. This study investigates such changes at the site of a 1979 crude-oil pipeline spill and is the first comprehensive look at groundwater chemistry associated with a residual hydrocarbon source zones in different stages of aging. The data show a direct relationship between concentrations of benzene and naphthalene in the residual oil and those measured in water samples collected below the oil. Groundwater associated with oil near the spill site had different chemical composition compared with water associated with oil that had spread downgradient from the spill zone, indicating a shift in biodegradation reactions. These results emphasize that source zone processes are spatially and temporally heterogeneous and should be accounted for in natural attenuation studies where residual source zones persist.

Minnesota

Examining the extraction efficiency of petroleum-derived dissolved organic matter in contaminated groundwater plumes

The extraction efficiency of petroleum-derived dissolved organic matter (DOM) was examined for groundwater samples from an aquifer contaminated with crude oil. Four different types of extraction were used to determine which method is best suited for the analysis of potentially toxic petroleum-derived DOM. The four types were a liquid-liquid extraction (LLE) with dichloromethane (EPA method 3510C), and three solid-phase extraction (SPE) stationary phases that are routinely used for extraction of polar analytes from water. For the LLE, that is selective for non-polar compounds, the extraction efficiency of petroleum-derived DOM decreased downgradient as the petroleum-derived DOM becomes increasingly polar due to biodegradation. In contrast, the average extraction efficiency by the SPE methods was greater than 65 % across the gradient. The results showed that SPE is more efficient for extracting petroleum-derived DOM at hydrocarbon-contaminated sites. The use of a method with greater extraction efficiency for partially-oxidized hydrocarbons may prove useful in determining relationships between their composition and structure and potential for risks to human health or the environment.

Ground Water Monitoring and Remediation

Potentially bioavailable natural organic carbon and hydrolyzable amino acids in aquifer sediments

This study evaluated the relationship between concentrations of operationally defined potentially bioavailable organic -carbon (PBOC) and hydrolyzable amino acids (HAAs) in sediments collected from a diverse range of chloroethene--contaminated sites. Concentrations of PBOC and HAA were measured using aquifer sediment samples collected at six selected study sites. Average concentrations of total HAA and PBOC ranged from 1.96 ± 1.53 to 20.1 ± 25.6 mg/kg and 4.72 ± 0.72 to 443 ± 65.4 mg/kg, respectively. Results demonstrated a statistically significant positive relationship between concentrations of PBOC and total HAA present in the aquifer sediment (p < 0.05). Higher levels of HAA were consistently observed at sites with greater levels of PBOC and first-order decay rates. Because amino acids are known to be readily biodegradable carbon compounds, this relationship suggests that the sequential chemical extraction procedure used to measure PBOC is a useful indicator of bioavailable carbon in aquifer sediments. This, in turn, is consistent with the interpretation that PBOC measurements can be used for estimating the amount of natural organic carbon available for driving the reductive dechlorination of chloroethenes in groundwater systems.

Ground Water Monitoring and Remediation