Abstract

The specific hydrogenotrophic activity of anaerobic sludges is usually assayed by gas chromatographic analysis for methane in the headspace of sealed test vials. Gas is sampled with a pressure lock syringe which allows quantification independent of the pressure prevailing in the vials. An alternative method was developed using pressure transducer monitoring of the decrease in headspace gas pressure as the H2/CO2 substrate is converted to CH4. Application of a simple formula related the decrease at each sample point to millilitres of CH4 produced and gave values for the specific hydrogenotrophic activity of granular anaerobic sludge which were in good agreement with the values obtained by the more labor-intensive gas chromatographic method. The simplicity of the method facilitates multiple replicate analyses and allows more accurate determination of initial rates than is achievable by the gas chromatographic method which is prone to analytical error at the very low concentrations of CH4 present in the headspace during the early stages of the assay. Mass transfer of H2 from headspace to liquid was found to be rate-limiting and to result in significant under-estimation of the specific hydrogenotrophic activity of the granular sludge. A test protocol, which used a vial volatile suspended solids concentration between 1.7 and 8 g l-1; a 1:5 ratio between liquid and headspace; incubation of the vials horizontally with vigorous shaking (180 rev./min) and an initial H2/CO2 (80/20) gas pressure of 100-150 kPa was found to give reproducible and maximal values for the specific hydrogenotrophic activity of the test sludge.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J.D. Coates, M.F. Coughlan, E. Colleran. 1996. Simple method for the measurement of the hydrogenotrophic methanogenic activity of anaerobic sludges. https://doi.org/10.1016/0167-7012(96)00915-3

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

Evaluation of a modified rapid viability-polymerase chain reaction method for Bacillus atrophaeus spores in water matrices

A rapid method that provides information on the viability of organisms is needed to protect public health and ensure that remediation efforts following a release of a biological agent are effective. The rapid viability-polymerase chain reaction (RV-PCR) method combines broth culture and molecular methods to provide results on whether viable organisms are present in less than 15 h. In this study, a modified RV-PCR (mRV-PCR) method was compared to a membrane-filtration culture method for the detection of viable Bacillus spores in water matrices. Samples included small and large volumes of chlorine and non‑chlorine treated tap water. Large volume water samples (up to 100 L), were processed by ultrafiltration using a semi-automated waterborne pathogen concentrator, followed by centrifugation as a secondary concentration technique. The concentrated samples were analyzed by mRV-PCR and culture methods. The overall agreement between the mRV-PCR and culture methods when seed concentrations were greater than 10 spores per sample volume analyzed was 96%. The total time from the start of sample processing to the final sample result for the mRV-PCR method was decreased by approximately 2 h, in comparison to the previously published RV-PCR method because of the incorporation of shorter, more efficient primary and secondary concentration steps and a shorter DNA extraction technique. Overall, this study confirmed that RV-PCR is a promising approach for identifying viable Bacillus spores in small- and large-volume water samples and for producing results in less time than traditional culture methods.

Journal of Microbiological Methods

Validation of a screening method for the detection of colistin-resistant E. coli containing mcr-1 in feral swine feces

A method was developed and validated for the detection of colistin-resistant Escherichia coli containing mcr-1 in the feces of feral swine. Following optimization of an enrichment method using EC broth supplemented with colistin (1 µg/mL) and vancomycin (8 µg/mL), aliquots derived from 100 feral swine fecal samples were spiked with of one of five different mcr-1 positive E. coli strains (between 100 and 104 CFU/g), for a total of 1,110 samples tested. Enrichments were then screened using a simple boil-prep and a previously developed real-time PCR assay for mcr-1 detection. The sensitivity of the method was determined in swine feces, with mcr-1 E. coli inoculums of 0.1-9.99 CFU/g (n = 340), 10-49.99 CFU/g (n = 170), 50-99 CFU/g (n = 255), 100-149 CFU/g (n = 60), and 200-2,200 CFU/g (n = 175), which were detected with 32%, 72%, 88%, 95%, and 98% accuracy, respectively. Uninoculated controls (n = 100) were negative for mcr-1 following enrichment.

Journal of Microbiological Methods

Nowcasting methods for determining microbiological water quality at recreational beaches and drinking-water source waters

Nowcasts are tools used to provide timely and accurate water-quality assessments of threats to drinking-water and recreational resources from fecal contamination or cyanobacterial harmful algal blooms. They use mathematical models and techniques to provide near-real-time estimates of fecal-indicator bacteria (FIB) and cyanotoxin concentrations. Techniques include logic-based thresholds, decision trees (built with machine learning), multiple linear and binary logistic regression, artificial neural networks, and process-based deterministic models. The type of site (freshwater, marine, or river) and dependent variable (FIB or cyanotoxin) dictate which explanatory variables are used in models. Nowcast systems notify the public of associated public-health risks and can also be used to manage data for FIB models; work is ongoing to incorporate cyanotoxin models into some nowcasts. The Great Lakes NowCast in the USA has been operational since 2010 and includes 25 lake beaches and one recreational river site. Examples of other operational FIB nowcasts are described for locations in the USA and around the world. In many cases, models predicted exceedances of FIB standards with accuracies as good as or better than using the previous measured FIB concentration (persistence method). Accuracy and timeliness are vital to beach management decisions that protect public health and support the local recreation-driven economy. Nowcasts benefit the public by providing estimates of water-quality conditions in near-real-time. Managers can use nowcasts at recreational and drinking-water treatment plant sites when FIB or cyanotoxins are projected to be elevated to target sample collection, to provide near-real-time recreational advisories to the public, or to preemptively optimize drinking-water treatments or change intake options to mitigate possible adverse effects on drinking-water quality.

Journal of Microbiological Methods