Multi-element analysis of manganese nodules by atomic absorption spectrometry without chemical separation

Abstract

Five manganese nodules, including the USGS reference nodules A-1 and P-1, were analyzed for Co, Cu, Fe, K, Mg, Mn, Na, Ni and Zn without prior chemical separation by using a simultaneous multi-element atomic absorption spectrometer with an air—cetylene flame. The nodules were prepared in three digestion matrices. One of these solutions was measured using sixteen different combinations of burner height and air/acetylene ratios. Results for A-1 and P-1 are compared to recommended values and results for all nodules are compared to those obtained with an inductively coupled plasma. The elements Co, Cu, Fe, K, Mg, Mn, Na, Ni, and Zn are simultaneously determined with a composite recovery for all elements of 100 ± 7%, independent of the digestion matrices, heights in the flame, or flame stoichiometries examined. Individual recoveries for Co, K, and Ni are considerably poorer in two digests than this composite figure, however. The optimum individual recoveries of 100 ± 5% and imprecisions of 1–4%, except for zinc, are obtained when Co, K, Mn, Na and Ni are determined simultaneously in a concentrated digest, and in another analytical sequence, when Cu, Fe, Mg, Mn and Zn are measured simultaneously after dilution. Determination of manganese is equally accurate in the two sequences; its measurement in both assures internal consistency between the two measurement sequences. This approach improves analytical efficiency over that for conventional atomic absorption methods, while minimizing loss of accuracy or precision for individual elements.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Jean S. Kane, J. M. Harnly. 1982. Multi-element analysis of manganese nodules by atomic absorption spectrometry without chemical separation. https://doi.org/10.1016/s0003-2670(01)94007-3

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

Rapid pre-concentration of mercury in solids and water for isotopic analysis

The precise quantification of mercury (Hg) stable isotope compositions in low concentration or dilute samples poses analytical challenges due to Hg mass limitations. Common Hg pre-concentration procedures require extended processing times, making rapid Hg stable isotope measurements challenging. Here we present a modified pre-concentration method that combines commonly used Hg reduction and gold trap amalgamation followed by semi-rapid thermal desorption (less than 1 h) and chemical trapping. This custom designed system was demonstrated to perform adequately on multiple trapping matrices including a new bromine monochloride (BrCl) wet oxidant trap (40% 3HNO 3 :BrCl), capable of trapping consistently in 2 mL volume over a wide range of Hg masses (5–200 ng). The procedure was also shown to work effectively on natural matrices, waters and sediments, producing comparable isotope results to the direct digestion analyses. Here, we present a method that can effectively triple sample throughput in comparison to traditional procedures, and also access lower concentration matrices without compromising the accuracy or precision of Hg isotope measurements.

Analytica Chimica Acta↗

Stability of low levels of perchlorate in drinking water and natural water samples

Perchlorate ion (ClO4-) is an environmental contaminant of growing concern due to its potential human health effects, impact on aquatic and land animals, and widespread occurrence throughout the United States. The determination of perchlorate cannot normally be carried out in the field. As such, water samples for perchlorate analysis are often shipped to a central laboratory, where they may be stored for a significant period before analysis. The stability of perchlorate ion in various types of commonly encountered water samples has not been generally examined-the effect of such storage is thus not known. In the present study, the long-term stability of perchlorate ion in deionized water, tap water, ground water, and surface water was examined. Sample sets containing approximately 1000, 100, 1.0, and 0.5 ??g l-1 perchlorate ion in deionized water and also in local tap water were formulated. These samples were analyzed by ion chromatography for perchlorate ion concentration against freshly prepared standards every 24 h for the first 7 days, biweekly for the next 4 weeks, and periodically after that for a total of 400 or 610 days for the two lowest concentrations and a total of 428 or 638 days for the high concentrations. Ground and surface water samples containing perchlorate were collected, held and analyzed for perchlorate concentration periodically over at least 360 days. All samples except for the surface water samples were found to be stable for the duration of the study, allowing for holding times of at least 300 days for ground water samples and at least 90 days for surface water samples. ?? 2006 Elsevier B.V. All rights reserved.

Analytica Chimica Acta↗

Development of a solenoid pumped in situ zinc analyzer for environmental monitoring

A battery powered submersible chemical analyzer, the Zn-DigiScan (Zn Digital Submersible Chemical Analyzer), has been developed for near real-time, in situ monitoring of zinc in aquatic systems. Microprocessor controlled solenoid pumps propel sample and carrier through an anion exchange column to separate zinc from interferences, add colorimetric reagents, and propel the reaction complex through a simple photometric detector. The Zn-DigiScan is capable of self-calibration with periodic injections of standards and blanks. The detection limit with this approach was 30 μg L −1 . Precision was 5–10% relative standard deviation (R.S.D.) below 100 μg L −1 , improving to 1% R.S.D. at 1000 μg L −1 . The linear range extended from 30 to 3000 μg L −1 . In situ field results were in agreement with samples analyzed by inductively coupled plasma mass spectrometry (ICPMS). This pump technology is quite versatile and colorimetric methods with complex online manipulations such as column reduction, preconcentration, and dilution can be performed with the DigiScan. However, long-term field deployments in shallow high altitude streams were hampered by air bubble formation in the photometric detector.

Analytica Chimica Acta↗