Geology Reports⌕ Search

USGS · 70011307

Lake phosphorus loading form septic systems by seasonally perched groundwater

Abstract

The movement of effluent phosphorus (P) from old septic systems by seasonally perched groundwater was investigated. A previous study indicated a correlation between P loadings and the presence of old homes. Water samples were taken from shallow wells installed 10 to 50 m downgradient from seven septic systems 20 to 40 years old. The equivalent volumetric fraction of each sample consisting of undiluted effluent was estimated from chloride concentration. A Monte Carlo analysis was used to account for the various sources of uncertainty. Movement of diluted septic effluent to the lake was common, but transport of more than 1% of effluent P through the soil was probable for only 4 of 26 samples. The greatest apparent P movement was associated with persistently saturated conditions.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R. J. Gilliom, C.R. Patmont. 1983. Lake phosphorus loading form septic systems by seasonally perched groundwater. https://pubs.usgs.gov/publication/70011307

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

Use of dissolved oxygen modeling results in the management of river quality

In 1973, the U.S. Geological Survey initiated a study of the Willamette River, Oregon, to determine the major causes of dissolved oxygen (DO) depletion, and whether advanced treatment of municipal wastewaters was needed to achieve the DO standards. The study showed that rates of carbonaceous decay were low (kr = 0.03-0.06/day) and that point-source loadings of carbonaceous biochemical oxygen demand (BOD) accounted for less than one-third of the satisfied oxygen demand. Nitrification of industrially discharged ammonia was the dominant cause of DO depletion. The study led to the calibration and verification of a steady-state DO model which was used to examine selected scenarios of BOD loading, ammonia loading, and flow augmentation. In 1976, the modeling projections for the Willamette River were presented to resource managers. A review in 1981 indicated that the State of Oregon had instituted an effluent standard on the major discharger of ammonia, rescinded an order for all municipal wastewaters to receive advanced secondary treatment by 1980, and more fully acknowledged the need for flow augmentation during summer to attain the DO standards.

Journal of the Water Pollution Control Federation↗

Evaluation of the river die-away biodegradation test

The reliability of the river die-away (RDA) test for establishing the biodegradability of chemicals was assessed. Reproducibility of biodegradation in the RDA test was analyzed under conditions in which the test is commonly done. Biodegradation results were not reproducible for di-2-ethylexyl phthalate (DEHP) and phthalic acid in replicated RDA tests using Missouri River water. Chemical and biological changes during the RDA tests probably reflected relative laboratory conditions. Initial suspended solids and subsequent DEHP biodegradation were directly related. Interpretation of RDA test results is enhanced by replicating experiments and comparing biodegradation of the test compound with a compound whose degradation properties are known. However, biodegradation measured with the RDA test is too variable and too dependent on laboratory treatment of samples to apply results directly to the aquatic environment.

Journal of the Water Pollution Control Federation↗

Methods of ultimate carbonaceous BOD determination

Studies were conducted to provide an accurate and practical technique for determining the concentration of ultimate carbonaceous biochemical oxygen demand and the rate at which this demand is exerted. The three methods evaluated were carbon derived, nitrification adjusted, and nitrification inhibited. The studies indicate that comparable concentrations and reaction rates can be determined from either non-nitrified samples using no chemical nitrifying inhibitor, or from partially nitrified samples using the chemical inhibitors, 1-allyl-2 thiourea or nitrapyrin, and that the combined use of time-series analysis and Lee's graphical method provide a reliable and accurate technique for determining ultimate biochemical oxygen demand concentration and reaction rate in 5 to 7 days.