Geology ReportsSearch

USGS · 70009869

A chemical-spectrochemical method for the determination of rare earth elements and thorium in cerium minerals

Abstract

In a combined chemical-spectrochemical procedure for quantitatively determining rare earth elements in cerium minerals, cerium is determined volumetrically, a total rare earths plus thoria precipitate is separated chemically, the ceria content of the precipitate is raised to 80·0 percent by adding pure ceria, and the resulting mixture is analyzed for lanthanum, praseodymium, neodymium, samarium, gadolinium, yttrium, and thorium spectrochemically by means of the d.c. carbon arc. Spectral lines of singly ionized cerium are used as internal standard lines in the spectrochemical determination which is patterned after Fassel's procedure [1]. Results of testing the method with synthetic mixtures of rare earths and with samples of chemically analyzed cerium minerals show that the coefficient of variation for a quadruplicate determination of any element does not exceed 5·0 (excepting yttrium at concentrations less than 1 percent) and that the method is free of serious systematic error.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H. J. Rose, K. J. Murata, M. K. Carron. 1954. A chemical-spectrochemical method for the determination of rare earth elements and thorium in cerium minerals. https://doi.org/10.1016/0371-1951(54)80368-7

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

Internal standards in fluorescent X-ray spectroscopy

The use of internal standards in the analysis of ores and minerals of widely-varying matrix by means of fluorescent X-ray spectroscopy is frequently the most practical approach. Internal standards correct for absorption and enhancement effects except when an absorption edge falls between the comparison lines or a very strong emission line falls between the absorption edges responsible for the comparison lines. Particle size variations may introduce substantial errors. One method of coping with the particle size problem is grinding the sample with an added abrasive.

Spectrochimica Acta

Double-chamber electrode for spectrochemical determination of chlorine and other halogens

A double-chamber, graphite electrode, suitable for d.c. arc determination of halogens by means of the alkaline earth halide bands, is described. An upper chamber holds the alkaline earth compound and an interconnected, lower chamber holds the halogen compound. This arrangement assures that there will be an abundance of alkaline earths in the arc by the time the halogen is volatilized from the lower chamber, and thereby promotes maximum emission of the alkaline earth halide bands.

Spectrochimica Acta