Geology ReportsSearch

USGS · 70006379

High-performance liquid chromatographic resolution and quantification of a dilacton antibiotic mixture (antimycin A)

Abstract

High-performance liquid chromatographic (HPLC) conditions are presented for the separation and quantitative determination of a homologous antibiotic complex (antimycin A). Combined HPLC and chemical ionization mass spectrometry proved to be exceptionally useful for the structural identification of chromatographic components. Using electrochemical, fluorescence, and ultraviolet detectors, the minimum detectable amounts of the antibiotics were found to be in the ranges 0.10–1.12, 0.31–1.69, and 4.10–28.2 ng, respectively. Advantages of the preparation of Dns derivatives for use in fluorescence detection are discussed. Application of the HPLC technique to the analysis of the antibiotic mixture in organic tissues is demonstrated.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S. L. Abidi. 1982. High-performance liquid chromatographic resolution and quantification of a dilacton antibiotic mixture (antimycin A). https://doi.org/10.1016/s0021-9673(00)81792-6

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

Determination of C6-C10 aromatic hydrocarbons in water by purge-and-trap capillary gas chromatography

A method is described for the determination of the C6-C10 aromatic hydrocarbons in water based on purge-and-trap capillary gas chromatography with flame ionization and mass spectrometric detection. Retention time data and 70 eV mass spectra were obtained for benzene and all 35 C7-C10 aromatic hydrocarbons. With optimized chromatographic conditions and mass spectrometric detection, benzene and 33 of the 35 alkylbenzenes can be identified and measured in a 45-min run. Use of a flame ionization detector permits the simultaneous determination of benzene and 26 alkylbenzenes.

Journal of Chromatography

Post-column reaction for simultaneous analysis of chromatic and leuco forms of malachite green and crystal violet by high-performance liquid chromatography with photometric detection

The chromatic and leuco forms of malachite green and crystal violet were readily separated and detected by a sensitive and selective high-performance liquid chromatographic procedure. The chromatic and leuco forms of the dyes were separated within 11 min on a C 18 column with a mobile phase of 0.05 M sodium acetate and 0.05 M acetic acid in water (19%) and methanol (81%). A reaction chamber, containing 10% PbO 2 in Celite 545, was placed between the column and the spectrophotometric detector to oxidize the leuco forms of the dyes to their chromatic forms. Chromatic and leuco malachite green were quantified by their absorbance at 618 nm; and chromatic and leuco Crystal Violet by their absorbance at 588 nm. Detection limits for chromatic and leuco forms of both dyes ranged from 0.12 to 0.28 ng. A linear range of 1 to 100 ng was established for both forms of the dyes.

Journal of Chromatography

Liquid-chromatography thermospray mass-spectrometric study of n-acylamino dilactones and 4-butyrolactones derived from Antimycin-A

Reversed-phase high-performance liquid chromatography—thermospray mass spectrometric (HPLC—MS) characteristics of four sets of lactonic complexes (one 4-butyrolactones and three dilactone complexes) derived from antimycin A were investigated. Three types of 8-hydroxy analogues were also included in the study. Pairs of a–b structures isomeric at the 8-acyloxy ester side-chains were best separated with a high-efficiency octadecylsilica column prior to analysis by HPLC—MS. Mass spectra of the a–b pairs each with identical molecular weights exhibited virtually indistinguishable fragmentation patterns, although their relative intensities were not superimposable. In some cases, HPLC—MS of the title compounds yielded mass chromatograms showing the minor components more easily recognizable than the HPLC—UV counter parts because of the apparent higher ionization efficiency of the minor isomers and increased resolution of subcomponents in the MS system. Under the mobile phase conditions employed, analyte ionization occurred with variable degrees of gas phase ammonolysis depending upon the ammonia concentration of the buffer. Potential applicability of the on-line HPLC—MS technique for the characterization of components in mixtures of antimycin analogues and isomers is demonstrated.

Journal of Chromatography