Geology Reports⌕ Search

USGS · 1015036

Isotope variations in white-tailed kites from various habitats in California: Possible limitations in assessing prey utilization and population dynamics

Abstract

White-tailed kite ( Elanus leucurus ) populations in the 1930s were close to extirpation in the United States. But by the 1940s, an upward trend towards recovery was apparent and continued to their current stable population levels. These dramatic fluctuations in kite numbers may have been related to changes in rodent prey populations due to the conversion of native habitats to agriculture. To address this question, we evaluated the use of stable isotope analysis in determining if a shift in diet could be isotopically differentiated in current and historic kite populations. We first compared δ 13 C, δ 15 N, and δ 34 S values from present-day kite flight feathers and prey fur samples from four locations in California. The total ranges of isotope values for kite and their rodent prey were similar within each site. Carbon isotope values ranged from m 27.1 to m 22.2‰ in Arcata, m 26.1 to m 16.9‰ in Davis, m 27.0 to m 15.0‰ in Cosumnes, and m 28.2 to m 11.6‰ in Santa Barbara. Nitrogen isotope values ranged from 3.2 to 15.7‰ in Arcata, 2.8 to 12.7‰ in Davis, 4.0 to 15.7‰ in Cosumnes, and 1.7 to 20.0‰ in Santa Barbara. Sulfur isotope values ranged from m 7.8 to 12.4‰ in Arcata, m 1.1 to 9.2‰ in Davis, 0.7 to 10.9‰ in Cosumnes, and m 8.6 to 15.6‰ in Santa Barbara. Carbon, nitrogen, and sulfur isotope values at each site reflect typical trophic enrichments due to physiological processes. At each site, δ 13 C and δ 15 N values reflected the influence of a predominantly C 3 or a mixed C 3 /C 4 plant community. Sulfur isotope values reflect the influence of predominant marine or terrestrial sulfur sources at each site. However, variability in isotope values may limit the usefulness of such analyses for addressing prey utilization and population dynamics.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

W.M. Iko, C.L. Kester, C.R. Bern, Rey C. Stendell, R. O. Rye. 2010-09-24. Isotope variations in white-tailed kites from various habitats in California: Possible limitations in assessing prey utilization and population dynamics. https://doi.org/10.1080/1025601031000108679

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

Online induction heating for determination of isotope composition of woody stem water with laser spectrometry: A methods assessment

Application of stable isotopes of water to studies of plant–soil interactions often requires a substantial preparatory step of extracting water from samples without fractionating isotopes. Online heating is an emerging approach for this need, but is relatively untested and major questions of how to best deliver standards and assess interference by organics have not been evaluated. We examined these issues in our application of measuring woody stem xylem of sagebrush using a Picarro laser spectrometer with online induction heating. We determined (1) effects of cryogenic compared to induction-heating extraction, (2) effects of delivery of standards on filter media compared to on woody stem sections, and (3) spectral interference from organic compounds for these approaches (and developed a technique to do so). Our results suggest that matching sample and standard media improves accuracy, but that isotopic values differ with the extraction method in ways that are not due to spectral interference from organics.

Isotopes in Environmental and Health Studies↗

Carbon isotope analysis of dissolved organic carbon in fresh and saline (NaCl) water via continuous flow cavity ring-down spectroscopy following wet chemical oxidation

This work examines the performance and limitations of a wet chemical oxidation carbon analyser interfaced with a cavity ring-down spectrometer (WCO-CRDS) in a continuous flow (CF) configuration for measuring &delta; 13 C of dissolved organic carbon ( &delta; 13 C-DOC) in natural water samples. Low-chloride matrix (<5 g Cl/L) DOC solutions were analysed with as little as 2.5 mg C/L in a 9 mL aliquot with a precision of 0.5 &permil;. In high-chloride matrix (10&ndash;100 g Cl/L) DOC solutions, bias towards lighter &delta; 13 C-DOC was observed because of incomplete oxidation despite using high-concentration oxidant, extended reaction time, or post-wet chemical oxidation gas-phase combustion. However, through a combination of dilution, chloride removal, and increasing the oxidant:sample ratio, high-salinity samples with sufficient DOC (>22.5 &micro;g C/aliquot) may be analysed. The WCO-CRDS approach requires more total carbon (&micro;g C/aliquot) than conventional CF-isotope ratio mass spectrometer, but is nonetheless applicable to a wide range of DOC concentration and water types, including brackish water, produced water, and basinal brines.

Isotopes in Environmental and Health Studies↗

USGS48 Puerto Rico precipitation - A new isotopic reference material for δ 2 H and δ 18 O measurements of water

A new secondary isotopic reference material has been prepared from Puerto Rico precipitation, which was filtered, homogenised, loaded into glass ampoules, sealed with a torch, autoclaved to eliminate biological activity, and calibrated by dual-inlet isotope-ratio mass spectrometry. This isotopic reference material, designated as USGS48, is intended to be one of two isotopic reference waters for daily normalisation of stable hydrogen (δ 2 H) and stable oxygen (δ 18 O) isotopic analysis of water with a mass spectrometer or a laser absorption spectrometer. The δ 2 H and δ 18 O values of this reference water are−2.0±0.4 and−2.224±0.012 ‰, respectively, relative to Vienna Standard Mean Ocean Water on scales normalised such that the δ 2 H and δ 18 O values of Standard Light Antarctic Precipitation reference water are−428 and−55.5 ‰, respectively. Each uncertainty is an estimated expanded uncertainty ( U =2 u c ) about the reference value that provides an interval that has about a 95 % probability of encompassing the true value. This isotopic reference water is available by the case of 144 glass ampoules containing 5 mL of water in each ampoule.

Puerto Rico↗