Geology ReportsSearch

Geology topics

Research about Pooler, Georgia

Source-linked reports with geographic coverage including Pooler, Georgia.

2 recordsLinked to original sources

Simulated effects of Lower Floridan aquifer pumping on the Upper Floridan aquifer at Pooler, Chatham County, Georgia

A revised regional groundwater-flow model was used to assess the potential effects on the Upper Floridan aquifer (UFA) of pumping the Lower Floridan aquifer (LFA) from a new well (35Q069) located at the City of Pooler in coastal Georgia near Savannah. The spatial resolution of the original regional, steady-state, groundwater-flow model was increased to incorporate detailed hydrogeologic information resulting from field investigations at Pooler and existing wells in the area. Simulation results using the U.S. Geological Survey finite-difference code MODFLOW indicated that long-term pumping at a rate of 780 gallons per minute (gal/min) from the LFA well 35Q069 would cause a maximum drawdown of about 2.52 feet (ft) in the UFA (scenario A). This maximum drawdown in the UFA was greater than the observed draw-down of 0.9 ft in the 72-hour aquifer test, but this is expected because the steady-state simulated drawdown represents long-term pumping conditions. Model results for scenario A indicate that drawdown in the UFA exceeded 1 ft over a 163-square-mile (mi 2 ) area. Induced vertical leakage from the UFA provided about 98 percent of the water to the LFA; the area within 1 mile of the pumped well contributed about 81 percent of the water pumped. Simulated pumping changed regional water-budget components slightly and redistributed flow among model layers, namely increasing downward leakage in all layers, decreasing upward leakage in all layers above the LFA, increasing inflow to and decreasing outflow from lateral specified-head boundaries in the UA and LFA, and increasing the volume of induced recharge from the general head boundary to outcrop units. An additional two groundwater-pumping scenarios were run to establish that a linear relation exists between pumping rates of the LFA well 35Q069 (varied from 390 to 1,042 gal/min) and amount of drawdown in the UFA and LFA. Three groundwater-pumping scenarios were run to evaluate the amount of UFA pumping (128 to 340 gal/min) that would produce maximum drawdown in the UFA equivalent to that induced by pumping the LFA well 35Q069 at rates specified in scenarios A, B, and C (390 to 1,042 gal/min). Scenarios in which the LFA well 35Q069 was pumped produced a larger drawdown area in the UFA than scenarios in which the UFA well was pumped to offset the maximum UFA drawdown simulated by scenarios A, B, and C. Three additional groundwater-pumping scenarios were run to evaluate the combination of pumping reductions at existing Pooler UFA public-supply wells with the addition of pumping from the new LFA well. For each scenario, LFA well 35Q069 was pumped at different rates, and pumping at existing Pooler supply wells, located about 3.7 miles northward, was reduced according to UFA drawdown offsets (128 to 340 gal/min) established by scenarios D, E, and F. Decreases in the magnitude and areal extent of drawdown in the UFA in response to pumping the LFA well were realized for scenarios that simulated drawdown offsets (reductions) for the existing UFA wells at Pooler when compared with the magnitude and extent of drawdown resulting from scenarios that did not simulate drawdown offsets for the existing UFA wells at Pooler (scenarios A, B, and C). The revised model was evaluated for sensitivity by altering horizontal and vertical hydraulic conductivity in layers 5 through 7 (Floridan aquifer system) for newly established hydraulic-property zones by factors of 0.1, 0.5, 2.0, and 10.0. Results of the sensitivity analysis indicate that horizontal and vertical hydraulic conductivity of the UFA and LFA are the most important parameters in model simulations. The least sensitive parameters were the horizontal and vertical hydraulic conductivity of the Lower Floridan confining unit; changes to these parameters had little effect on simulated leakage and groundwater levels. The revised model reasonably depicts changes in groundwater levels resulting from pumping the LFA at Pooler at a rate of 780 gal/min. However, results are limited by the same model assumptions and design as the original model and placement of boundaries and type of boundary used exert the greatest control on overall groundwater flow and interaquifer leakage in the system. Simulation results have improved regional characterization of the Floridan aquifer system, which could be used by State officials in evaluating requests for groundwater withdrawal from the LFA.

Georgia

Hydrogeology and water quality of the Floridan aquifer system and effect of Lower Floridan aquifer pumping on the Upper Floridan aquifer, Pooler, Chatham County, Georgia, 2011–2012

Two test wells were completed in Pooler, Georgia, in 2011 to investigate the potential of using the Lower Floridan aquifer as a source of water for municipal use. One well was completed in the Lower Floridan aquifer at a depth of 1,120 feet (ft) below land surface; the other well was completed in the Upper Floridan aquifer at a depth of 486 ft below land surface. At the Pooler test site, the U.S. Geological Survey performed flowmeter surveys, packer-isolated slug tests within the Lower Floridan confining unit, slug tests of the entire Floridan aquifer system, and aquifer tests of the Upper and Lower Floridan aquifers. Drill cuttings, geophysical logs, and borehole flowmeter surveys indicate that the Upper Floridan aquifer extends 333 –515 ft below land surface, the Lower Floridan confining unit extends 515–702 ft below land surface, and the Lower Floridan aquifer extends 702–1,040 ft below land surface. Flowmeter surveys indicate that the Upper Floridan aquifer contains two water-bearing zones at depth intervals of 339 –350 and 375–515 ft; the Lower Floridan confining unit contains one zone at a depth interval of 550–620 ft; and the Lower Floridan aquifer contains five zones at depth intervals of 702–745, 745–925, 925–984, 984–1,015, and 1,015–1,040 ft. Flowmeter testing of the test borehole open to the entire Floridan aquifer system indicated that the Upper Floridan aquifer contributed 92.4 percent of the total flow rate of 708 gallons per minute; the Lower Floridan confining unit contributed 3.0 percent; and the Lower Floridan aquifer contributed 4.6 percent. Horizontal hydraulic conductivity of the Lower Floridan confining unit derived from slug tests within three packer-isolated intervals ranged from 0.5 to 10 feet per day (ft/d). Aquifer-test analyses yielded values of transmissivity for the Upper Floridan aquifer, Lower Floridan confining unit, and the Lower Floridan aquifer of 46,000, 700, and 4,000 feet squared per day (ft 2 /d), respectively. Horizontal hydraulic conductivity of 4 ft/d for the Lower Floridan confining unit, derived from aquifer-test analyses, is near the midrange for values derived from packer-isolated slug tests. The transmissivity of the entire Floridan aquifer system derived from aquifer-test analyses totals about 51,000 ft 2 /d, similar to the value of 58,000 ft 2 /d derived from open slug tests on the entire Floridan aquifer system. Water-level data for each aquifer test were filtered for external influences such as barometric pressure, earth-tide effects, and long-term trends to enable detection of small (less than 1 foot) water-level responses to aquifer-test pumping. During the 72-hour aquifer test of pumping the Lower Floridan aquifer, a drawdown response of 51.7 ft was observed in the Lower Floridan pumped well and a drawdown response of 0.9 foot was observed in the Upper Floridan observation well located 85 ft from the pumped well.

Georgia