Geology ReportsSearch

Geology topics

Research about Kalamazoo, Michigan

Source-linked reports with geographic coverage including Kalamazoo, Michigan.

2 recordsLinked to original sources

Induced recharge of an artesian glacial-drift aquifer at Kalamazoo, Michigan

As part of a program for managing its ground-water supply, the city of Kalamazoo has constructed induced-recharge facilities at the sites of several of its well fields. To determine the benefits of induced recharge in a water-management program, the U.S. Geological Survey, in cooperation with the city, conducted a series of field experiments at a city well field (Station 9). The 12 production wells at the test site penetrate about 160 feet of glacial drift, which can be separated into three general units a lower aquifer, an intervening confining layer, and an upper aquifer. Although the upper aquifer is not tapped by any of the municipal supply wells, it serves as a storage and transmission medium for water from the West Fork Portage Creek. The testing program consisted of four aquifer and three recharge tests. The aquifer tests show that the transmissibility of the upper and lower aquifers ranges from 50,000 to 100,000 gallons per day per foot and indicate that nearly 200 gpm (gallons per minute) leaks through the intervening aquiclude under nonpumping conditions. The object of the three recharge tests (tests 5, 6, and 7) was to observe the effects of induced recharge by varying conditions in the recharge channel. During the three recharge tests, 7 wells were pumped at a total rate averaging about 2,500 gpm. During test 5, inflow to the channel was shut off, and the water level in the channel was allowed to decline. Drawdowns measured during this test were used as a standard for comparison with drawdowns in tests 6 and 7. During test 6, the head in the recharge channel was maintained as constant as possible, and the inflow to the channel was measured. The rate of induced recharge, as indicated by the measured inflow, averaged about 300 gpm. Between tests 6 and 7, the area of the channel was increased from 27,000 to 143,000 square feet. During test 7, the head in the channel was again maintained as constant as possible, but the inflow to the larger channel increased to about 600 gpm. The principal effect of induced recharge on the two aquifers was to reduce the amount and rate of drawdown. Therefore, where water levels and artesian pressures can be maintained at high stages, the result is lower pumping costs and increased rates of withdrawal during periods of peak demand.

Michigan

Controlled induced recharge tests at Kalamazoo, Mich

This article discusses the results of a controlled field testing program, which indicated that definite hydraulic and other advantages may be gained from induced recharging as practiced at Kalamazoo, Michigan. Results include the following: water levels and artesian pressures can be maintained at high stages, the results are lower pumping lifts and substantial reductions in the amount of power used for pumping; the high water levels permit increased rates of withdrawal during periods of peak demand; encroachment of poor quality water from other aquifers is minimized; the surface water induced into the aquifer is filtered naturally through great thicknesses of earth materials; natural underground storage is used to conserve and protect water, which otherwise would flow largely to waste; and, significant supplemental benefits, including flood control, have been derived. The tests demonstrated that it is possible to manipulate the regimen of a complex hydrologic system for definite hydraulic benefits with predictable results. Furthermore with current methods, quantitative evaluations may be made of the effects of induced recharge. The results of the tests, therefore, are applicable in other areas of similar hydrogeologic environments.

Michigan