Geology ReportsSearch

Geology topics

Research about Fort Worth, Texas

Source-linked reports with geographic coverage including Fort Worth, Texas.

At least 19 recordsLinked to original sources

Degree of contamination and sources of polychlorinated biphenyls in Meandering Road Creek and Woods Inlet of Lake Worth, Fort Worth, Texas, 2004 and 2006-07

Lake Worth is a reservoir on the West Fork Trinity River on the western edge of Fort Worth, Texas. Air Force Plant 4 (AFP4) is on the eastern shore of Woods Inlet, an arm of Lake Worth that extends south from the main body of the lake. Two previous reports documented ele­vated polychlorinated biphenyl (PCB) concentrations in surficial sediment in Woods Inlet relative to those in surficial sediment in other parts of Lake Worth. This report presents the results of another USGS study, done in cooperation with the U.S. Air Force, to indicate the degree of PCB contamination of Meandering Road Creek and Woods Inlet and to identify possible sources of PCBs in Meandering Road Creek and Woods Inlet on the basis of suspended, streambed, and lake-bottom sediment samples collected there in 2004 and 2006–07. About 40 to 80 percent of total PCB concentrations (depending on how total PCB concentration is computed) in suspended sediment exceed the threshold effect concentration, a concentration below which adverse effects to benthic biota rarely occur. About 20 percent of total PCB concentrations (computed as sum of three Aroclors) in suspended sediment exceed the probable effect concentration, a concentration above which adverse effects to benthic biota are expected to occur frequently. About 20 to 30 percent of total PCB concentrations in streambed sediment exceed the threshold effect concentration; and about 6 to 20 percent of total PCB concentrations in lake-bottom (Woods Inlet) sediment exceed the threshold effect concentration. No streambed or lake-bottom sediment concentrations exceed the probable effect concentration. The sources of PCBs to Meandering Road Creek and Woods Inlet were investigated by comparing the relative distributions of PCB congeners of suspended sediment to those of streambed and lake-bottom sediment. The sources of PCBs were identified using graphical analysis of normalized concentrations (congener ratios) of 11 congeners. For graphical analysis, the sampling sites were divided into three groups with each group associated with one of the three outfalls sampled: SSO, OF4, and OF5. The variations of normalized PCB congener concentrations from Woods Inlet, from outfalls along Meandering Road Creek, and from streambed sediment sampling sites along Meandering Road Creek generally form similar patterns within sample groups, which is indicative of a common source of PCBs to each group. Overall, the variations in congener ratios indicate that PCBs in surficial lake-bottom sediment of Woods Inlet probably entered Woods Inlet primarily from Meandering Road Creek, and that runoff from AFP4 is a prominent source of PCBs in Meandering Road Creek. Sixteen of the 20 box core sites in Woods Inlet had lower PCB concentrations in the 2006 cores compared to those in the 2003 cores.

Texas

Two-dimensional resistivity investigation along West Fork Trinity River, Naval Air Station-Joint Reserve Base Carswell Field, Fort Worth, Texas, October 2004

Naval Air Station-Joint Reserve Base Carswell Field (NAS-JRB) at Fort Worth, Tex., constitutes a government-owned, contractor-operated facility that has been in operation since 1942. Contaminants, primarily volatile organic compounds and metals, have entered the ground-water-flow system through leakage from waste-disposal sites and manufacturing processes. Ground water flows from west to east toward the West Fork Trinity River. During October 2004, the U.S. Geological Survey conducted a two-dimensional (2D) resistivity investigation at a site along the West Fork Trinity River at the eastern boundary of NAS-JRB to characterize the distribution of subsurface resistivity. Five 2D resistivity profiles were collected, which ranged from 500 to 750 feet long and extended to a depth of 25 feet. The Goodland Limestone and the underlying Walnut Formation form a confining unit that underlies the alluvial aquifer. The top of this confining unit is the top of bedrock at NAS-JRB. The bedrock confining unit is the zone of interest because of the potential for contaminated ground water to enter the West Fork Trinity River through saturated bedrock. The study involved a capacitively-coupled resistivity survey and inverse modeling to obtain true or actual resistivity from apparent resistivity. The apparent resistivity was processed using an inverse modeling software program. The results of this program were used to generate distributions (images) of actual resistivity referred to as inverted sections or profiles. The images along the five profiles show a wide range of resistivity values. The two profiles nearest the West Fork Trinity River generally showed less resistivity than the three other profiles.

Texas

Particle-associated contaminants in street dust, parking lot dust, soil, lake-bottom sediment, and suspended and streambed sediment, Lake Como and Fosdic Lake watersheds, Fort Worth, Texas, 2004

A previous study by the U.S. Geological Survey of impaired water bodies in Fort Worth, Texas, reported elevated but variable concentrations of particle-associated contaminants (PACs) comprising chlorinated hydrocarbons, polycyclic aromatic hydrocarbons, and trace elements in suspended and bed sediment of lakes and streams affected by urban land use. The U.S. Geological Survey, in cooperation with the City of Fort Worth, collected additional samples during October 2004 to investigate sources of PACs in the watersheds of two impaired lakes: Lake Como and Fosdic Lake. Source materials and aquatic sediment were sampled and analyzed for PACs. Source materials sampled consisted of street dust and soil from areas with residential and commercial land use and parking lot dust from sealed and unsealed parking lots. Aquatic sediment sampled consisted of bottom-sediment cores from the two lakes and suspended and streambed sediment from the influent stream of each lake. Samples were analyzed for chlorinated hydrocarbons (organochlorine pesticides and polychlorinated biphenyls), polycyclic aromatic hydrocarbons, major and trace elements, organic carbon, grain size, and radionuclides.

Texas

Geodatabase of environmental information for Air Force Plant 4 and Naval Air Station-Joint Reserve Base Carswell Field, Fort Worth, Texas, 1990-2004

Air Force Plant 4 (AFP4) and adjacent Naval Air Station-Joint Reserve Base (NAS-JRB) at Fort Worth, Tex., constitute a government-owned, contractor-operated (GOCO) facility that has been in operation since 1942. Contaminants from the facility, primarily volatile organic compounds (VOCs) and metals, have entered the groundwater-flow system through leakage from waste-disposal sites (landfills and pits) and from manufacturing processes (U.S. Air Force, Aeronautical Systems Center, 1995). The U.S. Geological Survey (USGS), in cooperation with the U.S. Air Force (USAF), Aeronautical Systems Center, Environmental Management Directorate (ASC/ENVR), developed a comprehensive database (or geodatabase) of temporal and spatial environmental information associated with the geology, hydrology, and water quality at AFP4 and NAS-JRB. The database of this report provides information about the AFP4 and NAS-JRB study area including sample location names, identification numbers, locations, historical dates, and various measured hydrologic data. This database does not include every sample location at the site, but is limited to an aggregation of selected digital and hardcopy data of the USAF, USGS, and various consultants who have previously or are currently working at the site.

Texas

Distribution and sources of polychlorinated biphenyls in Woods Inlet, Lake Worth, Fort Worth, Texas, 2003

Woods Inlet is a flooded stream channel on the southern shore of Lake Worth along the western boundary of Air Force Plant 4 in Fort Worth, Texas, where elevated polychlorinated biphenyl (PCB) concentrations in sediment were detected in a previous study. In response, the U.S. Geological Survey, in cooperation with the U.S. Air Force, conducted a study in 2003 to map the extent of elevated PCB concentrations in Woods Inlet and to identify possible sources (or more specifically, source areas) of PCBs in the watershed of Woods Inlet. Three gravity cores (penetration to pre-reservoir sediment at three sites) and 17 box cores (surficial bottom sediment samples) were collected in Woods Inlet. Suspended sediment in stormwater runoff and streambed sediment were sampled in tributaries to Woods Inlet following storms. Assemblages of PCB congeners in surficial inlet sediments and suspended and streambed sediments were analyzed to indicate sources of PCBs in the inlet sediments on the basis of chemical signatures of PCBs. Woods Inlet receives runoff primarily from three tributaries: (1) Gruggs Park Creek, (2) the small unnamed creek that drains a Texas National Guard maintenance facility, called TNG Creek for this report, and (3) Meandering Road Creek. Twenty-seven of 209 possible PCB congeners were analyzed. The sum of the congeners was used as a measure of total PCB. The spatial distribution of total PCB concentrations in the inlet indicates that most PCBs are originating in the Meandering Road Creek watershed. Peak total PCB concentrations in the three gravity cores occurred at depths corresponding to sediment deposition dates of about 1960 for two of the cores and about 1980 for the third core. The magnitudes of peak total PCB concentrations in the gravity cores followed a spatial distribution generally similar to that of surficial bottom sediment concentrations. Total PCB concentrations in suspended and streambed sediment varied greatly between sites and indicated a likely source of PCBs associated with a sampling site that receives runoff from Air Force Plant 4. Three approaches to the analyses of congener assemblages indicate that PCBs in surficial bottom sediment of Woods Inlet primarily enter Lake Worth from Meandering Road Creek and that runoff from Air Force Plant 4 is a source of the PCBs in Meandering Road Creek. Although current (2003) transport of PCBs from Air Force Plant 4 to the creek is occurring, large decreases in PCB concentrations with decreasing age in two cores indicate that PCB loading to the inlet has decreased greatly since the 1960s. Because runoff entering Meandering Road Creek from some parts of Air Force Plant 4 was not measured or sampled in this study, it cannot be said with certainty that the Air Force Plant 4 site sampled is the only source of PCBs to Meandering Road Creek.

Texas

Subsurface occurrence and potential source areas of chlorinated ethenes identified using concentrations and concentration ratios, Air Force Plant 4 and Naval Air Station-Joint Reserve Base Carswell Field, Fort Worth, Texas

The U.S. Geological Survey, in cooperation with the U.S. Air Force Aeronautical Systems Center, Environmental Management Directorate, conducted a study during 2003-05 to characterize the subsurface occurrence and identify potential source areas of the volatile organic compounds classified as chlorinated ethenes at U.S. Air Force Plant 4 (AFP4) and adjacent Naval Air Station-Joint Reserve Base Carswell Field (NAS-JRB) at Fort Worth, Texas. The solubilized chlorinated ethenes detected in the alluvial aquifer originated as either released solvents (tetrachloroethene [PCE], trichloroethene [TCE], and trans -1,2-dichloroethene [ trans -DCE]) or degradation products of the released solvents (TCE, cis -1,2-dichloroethene [ cis -DCE], and trans -DCE). The combined influences of topographic- and bedrock-surface configurations result in a water table that generally slopes away from a ground-water divide approximately coincident with bedrock highs and the 1-mile-long aircraft assembly building at AFP4. Highest TCE concentrations (10,000 to 920,000 micrograms per liter) occur near Building 181, west of Building 12, and at landfill 3. Highest PCE concentrations (500 to 920 micrograms per liter) occur near Buildings 4 and 5. Highest cis -DCE concentrations (5,000 to 710,000 micrograms per liter) occur at landfill 3. Highest trans -DCE concentrations (1,000 to 1,700 micrograms per liter) occur just south of Building 181 and at landfill 3. Ratios of parent-compound to daughter-product concentrations that increase in relatively short distances (tens to 100s of feet) along downgradient ground-water flow paths can indicate a contributing source in the vicinity of the increase. Largest increases in ratio of PCE to TCE concentrations are three orders of magnitude from 0.01 to 2.7 and 7.1 between nearby wells in the northeastern part of NAS-JRB. In the northern part of NAS-JRB, the largest increases in TCE to total DCE concentration ratios relative to ratios at upgradient wells are from 17 to 240 or from 17 to 260. In the southern part of NAS-JRB, the largest ratio increases with respect to those at upgradient wells are from 22 and 24 to 130, and from 0 and 7.2 to 71. Numerous maximum historical ratios of trans -DCE to cis -DCE are greater than 1, which can indicate that trans -DCE likely was released as a solvent and does not occur only as a result of degradation of TCE. High concentrations of TCE, PCE, cis -DCE, and trans -DCE, abrupt increases in ratios of PCE to TCE and TCE to total DCE, and ratios of trans -DCE to cis -DCE greater than 1 were used to identify 16 potential source areas of chlorinated ethenes at NAS-JRB. The evidence for some of the potential source areas is stronger than for others, but each area reflects one or more of the conditions indicative of chlorinated ethenes entering the aquifer. Potential source areas supported by the strongest evidence are Building 181, between buildings 4 and 5, just west of Building 12, and landfills 1 and 3. The highest historical TCE concentration in the study area, 920,000 micrograms per liter, is near Building 181. The potential source area between Buildings 4 and 5 primarily is identified by notably high PCE concentrations (to 920 micrograms per liter). Primary evidence for the potential source are just west of Building 12 is the notably high TCE concentrations (for example, 160,000 micrograms per liter) that appear to originate in the area. Primary evidence for the potential source area at landfills 1 and (primarily) 3 is the magnitudes of TCE concentrations (for example, two in the 100,000-to-920,000-microgram-per-liter range), cis -DCE concentrations (several in the 5,000-to-710,000-microgram-per-liter range), and trans -DCE concentrations (several in the 500-to-1,700-microgram-per-liter range). The ratio of trans -DCE to cis -DCE at one well in landfill 3 (6.7) is appreciably above the threshold that can indicate likely solvent release as opposed to TCE degradation alone.

Texas

Overview--Development of a geodatabase and conceptual model of the hydrogeologic units beneath Air Force Plant 4 and Naval Air Station-Joint Reserve Base Carswell Field, Fort Worth, Texas

Air Force Plant 4 (AFP4) and adjacent Naval Air Station-Joint Reserve Base Carswell Field (NAS–JRB) at Fort Worth, Tex., constitute a contractor-owned, government-operated facility that has been in operation since 1942. Contaminants from the 3,600-acre facility, primarily volatile organic compounds (VOCs) and metals, have entered the ground-water-flow system through leakage from waste-disposal sites and from manufacturing processes. Environmental data collected at AFP4 and NAS–JRB during 1993–2002 created the need for consolidation of the data into a comprehensive temporal and spatial geodatabase. The U.S. Geological Survey (USGS), in cooperation with the U.S. Air Force Aeronautical Systems Center Environmental Management Directorate, developed a comprehensive geodatabase of temporal and spatial environmental data associated with the hydrogeologic units beneath the facility. A three-dimensional conceptual model of the hydrogeologic units integrally linked to the geodatabase was designed concurrently. Three hydrogeologic units—from land surface downward, the alluvial aquifer, the GoodlandWalnut confining unit, and the Paluxy aquifer—compose the subsurface of interest at AFP4 and NAS–JRB. The alluvial aquifer consists primarily of clay and silt with sand and gravel channel deposits that might be interconnected or interfingered. The Goodland-Walnut confining unit directly underlies the alluvial aquifer and consists of limestone, marl, shale, and clay. The Paluxy aquifer is composed of dense mudstone and fine- to coarse-grained sandstone

Texas

Demonstration-site development and phytoremediation processes associated with trichloroethene (TCE) in ground water, Naval Air Station-Joint Reserve Base Carswell Field, Fort Worth, Texas

A field-scale phytoremediation demonstration study was initiated in 1996 by the U.S. Geological Survey (USGS), in cooperation with the U.S. Air Force, at a site on Naval Air StationJoint Reserve Base Carswell Field (NAS–JRB) adjacent to Air Force Plant 4 (AFP4) in Fort Worth, Tex. (fig. 1). Trichloroethene (TCE) has been used at AFP4 in aircraft manufacturing processes for decades; spills and leaks from tanks in the manufacturing building have resulted in shallow ground-water contamination on-site and downgradient from the facility (Eberts and others, 2003). The objective of the study was to determine the effectiveness of eastern cottonwoods ( Populus deltoides ) in decreasing the mass of dissolved TCE in ground water through phytoremediation. Phytoremediation is a process by which plants decrease the mass of a contaminant through a variety of chemical, physical, and biological means. Before development of the phytoremediation demonstration site, natural attenuation of TCE at the site occurred by sorption, dispersion, dilution, and possibly volatilization (Eberts and others, 2003). Long-term, field-scale monitoring and evaluation of this site contribute to the understanding of the processes associated with phytoremediation and provide practical information about field-scale applications of the method. This fact sheet briefly summarizes the development of the phytoremediation demonstration site at NAS–JRB and describes some of the physical and chemical processes associated with phytoremediation. The phytoremediation demonstration site is on the southern edge of the central lobe of a TCE plume in the surficial (alluvial) aquifer. The plume originates at AFP4 about 0.9 mile upgradient from the site (fig. 1). The 9.5-acre site is in the northwestern corner of the golf course on NAS–JRB. The saturated thickness of the alluvial aquifer, which is composed of clay, silt, sand, and gravel, ranges from about 1.5 to 5 feet at the site. The total thickness of the alluvial aquifer ranges from about 6 to 15 feet. The Goodland-Walnut confining unit, composed of massively bedded shaley limestone, underlies the alluvial aquifer. The general direction of ground-water flow in the study area (fig. 2) is from northwest to southeast, approximately perpendicular to the long sides of the cottonwood plantations. Ground water flows toward Farmers Branch Creek in the area southwest of the golf cart path. At the time of site characterization in August 1996, depth to water ranged from 8 to 13 feet below land surface.

Texas

Development of a geodatabase and conceptual model of the hydrogeologic units beneath air force plant 4 and Naval Air Station-Joint Reserve Base Carswell Field, Fort Worth, Texas

Air Force Plant 4 and adjacent Naval Air Station-Joint Reserve Base Carswell Field at Fort Worth, Texas, constitute a government-owned, contractor-operated facility that has been in operation since 1942. Contaminants from AFP4, primarily volatile organic compounds and metals, have entered the ground-water-flow system through leakage from waste-disposal sites and from manufacturing processes. The U.S. Geological Survey developed a comprehensive geodatabase of temporal and spatial environmental information associated with the hydrogeologic units (alluvial aquifer, Goodland-Walnut confining unit, and Paluxy aquifer) beneath the facility and a three-dimensional conceptual model of the hydrogeologic units integrally linked to the geodatabase. The geodatabase design uses a thematic layer approach to create layers of feature data using a geographic information system. The various features are separated into relational tables in the geodatabase on the basis of how they interact and correspond to one another. Using the geodatabase, geographic data at the site are manipulated to produce maps, allow interactive queries, and perform spatial analyses. The conceptual model for the study area comprises computer-generated, three-dimensional block diagrams of the hydrogeologic units. The conceptual model provides a platform for visualization of hydrogeologic-unit sections and surfaces and for subsurface environmental analyses. The conceptual model is based on three structural surfaces and two thickness configurations of the study area. The three structural surfaces depict the altitudes of the tops of the three hydrogeologic units. The two thickness configurations are those of the alluvial aquifer and the Goodland-Walnut confining unit. The surface of the alluvial aquifer was created using a U.S. Geological Survey 10-meter digital elevation model. The 2,130 point altitudes of the top of the Goodland-Walnut unit were compiled from lithologic logs from existing wells, available soil-boring logs, and previous studies. Data from 120 wells, primarily from existing reports, were used to create a map of the approximate altitude of the Paluxy aquifer.

Texas

Analyses and estimates of hydraulic conductivity from slug tests in alluvial aquifer underlying Air Force Plant 4 and Naval Air Station-Joint Reserve Base Carswell Field, Fort Worth, Texas

This report describes the collection, analyses, and distribution of hydraulic-conductivity data obtained from slug tests completed in the alluvial aquifer underlying Air Force Plant 4 and Naval Air Station-Joint Reserve Base Carswell Field, Fort Worth, Texas, during October 2002 and August 2003 and summarizes previously available hydraulic-conductivity data. The U.S. Geological Survey, in cooperation with the U.S. Air Force, completed 30 slug tests in October 2002 and August 2003 to obtain estimates of horizontal hydraulic conductivity to use as initial values in a ground-water-flow model for the site. The tests were done by placing a polyvinyl-chloride slug of known volume beneath the water level in selected wells, removing the slug, and measuring the resulting water-level recovery over time. The water levels were measured with a pressure transducer and recorded with a data logger. Hydraulic-conductivity values were estimated from an analytical relation between the instantaneous displacement of water in a well bore and the resulting rate of head change. Although nearly two-thirds of the tested wells recovered 90 percent of their slug-induced head change in less than 2 minutes, 90-percent recovery times ranged from 3 seconds to 35 minutes. The estimates of hydraulic conductivity range from 0.2 to 200 feet per day. Eighty-three percent of the estimates are between 1 and 100 feet per day.

Texas

The role of microbial reductive dechlorination of TCE at a phytoremediation site

In April 1996, a phytoremediation field demonstration site at the Naval Air Station, Fort Worth, Texas, was developed to remediate shallow oxic ground water (<3.7 m deep) contaminated with chlorinated ethenes. Microbial populations were sampled in February and June 1998. The populations under the newly planted cottonwood trees had not yet matured to an anaerobic community that could dechlorinate trichloroethene (TCE) to cis -1,2-dichloroethene (DCE); however, the microbial population under a mature (∼22-year-old) cottonwood tree about 30 m southwest of the plantings had a mature anaerobic population capable of dechlorinating TCE to DCE, and DCE to vinyl chloride (VC). Oxygen-free sediment incubations with contaminated groundwater also demonstrated that resident microorganisms were capable of the dechlorination of TCE to DCE. This suggests that a sufficient amount of organic material is present for microbial dechlorination in aquifer microniches where dissolved O 2 concentrations are low. Phenol, benzoic acid, acetic acid, and a cyclic hydrocarbon, compounds consistent with the degradation of root exudates and complex aromatic compounds, were identified by gas chromatography/mass spectrometry (GC/MS) in sediment samples under the mature cottonwood tree. Elsewhere at the site, transpiration and degradation by the cottonwood trees appears to be responsible for loss of chlorinated ethenes.

Texas

Occurrence, trends, and sources in particle-associated contaminants in selected streams and lakes in Fort Worth, Texas

Several lakes and stream segments in Fort Worth, Texas, have fish consumption bans because of elevated levels of chlordane, dieldrin, DDE, and polychlorinated biphenyls (PCBs). This study was undertaken to evaluate current loading, trends, and sources in these long-banned contaminants and other particle-associated contaminants commonly found in urban areas. Sampling included suspended sediments at 11 sites in streams and bottom-sediment cores in three lakes. Samples were analyzed for chlorinated hydrocarbons, major and trace elements, and polycyclic aromatic hydrocarbons (PAHs). All four legacy pollutants responsible for fish consumption bans were detected frequently. Concentrations of chlordane, lead, and PAHs most frequently exceeded sediment-quality guidelines. Trends in DDE and PCBs since the 1960s generally are decreasing; and trends in chlordane are mixed with a decreasing trend in Lake Como, no trend in Echo Lake, and an increasing trend in Fosdic Lake. All significant trends in trace elements are decreasing, and most significant trends in PAHs are increasing. Sedimentation surveys were conducted on each of the three lakes and used in combination with sediment core data to compute sediment mass balances for the lakes, to estimate long-term-average loads and yields of sediment, and to estimate recent loads and yields of selected contaminants. Concentrations of most trace elements in suspended sediments were similar to those at the tops of cores, but concentrations of many hydrophobic organic contaminants were two to three times larger. As a result, for these fluvial systems, sediment cores probably provide a historical record of trace element contamination but could underestimate historical concentrations of organic contaminants. However, down-core profiles suggest that relative concentration histories are preserved in these sediment cores for many organic contaminants (such as chlordane and total DDT) but not for all (such as dieldrin). Percent urban land use correlates strongly with selected contaminant concentrations in sediments. Organochlorine pesticides had significant correlations to residential land use, whereas PCBs, cadmium, lead, zinc, and PAHs more often correlate significantly with commercial and industrial land uses, which suggests different urban sources for different contaminants. The amount of enrichment in these contaminants associated with urban land use predicted from regression equations, expressed as the ratio of concentrations predicted for 100 percent urban to 30 percent urban, ranges from 3.6 to 6.9 for PCBs and heavy metals to about 15 for chlordane, total DDT, and PAHs. These data indicate that urbanization is having a substantial negative effect on sediment and water quality and that legacy pollutants are being actively transported to streams and lakes 13 to 30 years after their use was restricted or banned. They further suggest that fish in the lakes and these water bodies will continue to be exposed to legacy pollutants in sediment for many years to come.

Texas

Spatial distribution and trends in trace elements, polycyclic aromatic hydrocarbons, organochlorine pesticides, and polychlorinated biphenyls in Lake Worth sediment, Fort Worth, Texas

In spring 2000, the Texas Department of Health issued a fish consumption advisory for Lake Worth in Fort Worth, Texas, because of elevated concentrations of polychlorinated biphenyls (PCBs) in fish. In response to the advisory and in cooperation with the U.S. Air Force, the U.S. Geological Survey collected 21 surficial sediment samples and three gravity core sediment samples to assess the spatial distribution and historical trends of selected hydrophobic contaminants, including PCBs, and to determine, to the extent possible, sources of hydrophobic contaminants to Lake Worth. Compared to reference (background) concentrations in the upper lake, elevated PCB concentrations were detected in the surficial sediment samples collected in Woods Inlet, which receives surface runoff from Air Force facilities and urban areas. Gravity cores from Woods Inlet and from the main part of the lake near the dam indicate that the concentrations of PCBs were three to five times higher in the 1960s than in 2000. A regression method was used to normalize sediment concentrations of trace elements for natural variations and to distinguish natural and anthropogenic contributions to sediments. Concentrations of several trace elements—cadmium, chromium, copper, lead, and zinc—were elevated in sediments in Woods Inlet, along the shoreline of Air Force facilities, and in the main lake near the dam. Concentrations of these five trace elements have decreased since 1970. Polycyclic aromatic hydrocarbons also were elevated in the same areas of the lake. Concentrations of total polycyclic aromatic hydrocarbons, normalized with organic carbon, were mostly stable in the upper lake but steadily increased near the dam, except for small decreases since 1980. The Woods Inlet gravity core showed the largest increase of the three core sites beginning about 1940; total polycyclic aromatic hydrocarbon concentrations in post-1940 sediments from the core showed three apparent peaks about 1960, 1984, and 2000. The concentrations of organochlorine pesticides were low relative to consensus-based sediment-quality guidelines and either decreased or remained constant since 1970. The two likely sources of hydrophobic contaminants to the lake are urban areas around the lake and the drainage area of Meandering Road Creek that contributes runoff to Woods Inlet and includes Air Force facilities.

Texas

Data on occurrence of selected trace metals, organochlorines, and semivolatile organic compounds in edible fish tissues from Lake Worth, Fort Worth, Texas, 1999

A public-health assessment conducted for the Texas Department of Health and the Agency for Toxic Substances and Disease Registry concluded that exposure to contaminants through the aquatic food chain is an indeterminate human-health hazard in Lake Worth, Fort Worth, Texas. In 1999, the U.S. Geological Survey, in cooperation with the U.S. Air Force and in collaboration with the Texas Department of Health, collected samples of edible fish tissues from Lake Worth for analysis of selected trace metals, organochlorines, and semivolatile organic compounds to support a human-health risk assessment. Left-side, skin-off fillet samples were collected from 10 individuals each of channel catfish, common carp, freshwater drum (gaspergou), largemouth bass, and white crappie but only from five smallmouth buffalo. The U.S. Geological Survey National Water Quality Laboratory analyzed the samples for 22 trace metals, 40 organochlorine pesticides and polychlorinated biphenyls, and 75 semivolatile organic compounds.

Texas

Subsurface evaluation of the west parking lot and landfill 3 areas of Air Force Plant 4, Fort Worth, Texas, using two-dimensional direct-current resistivity profiling

During September 1999, the U.S. Geological Survey made 10 two-dimensional direct-current resistivity profile surveys in the west parking lot and landfill 3 areas of Air Force Plant 4, Fort Worth, Texas, to identify subsurface areas of anomalously high or low resistivity that could indicate potential contamination, contaminant pathways, or anthropogenic structures. Six of the 10 surveys (transects) were in the west parking lot. Each of the inverted sections of these transects had anomalously high resistivities in the terrace alluvium/fill (the surficial subsurface layer) that probably were caused by highly resistive fill material. In addition, each of these transects had anomalously low resistivities in the Walnut Formation (a bedrock layer immediately beneath the alluvium/fill) that could have been caused by saturation of fractures within the Walnut Formation. A high-resistivity anomaly in the central part of the study area probably is associated with pea gravel fill used in construction of a French drain. Another high resistivity anomaly in the west parking lot, slightly southeast of the French drain, could be caused by dense nonaqueous-phase liquid in the Walnut Formation. The inverted sections of the four transects in the landfill 3 area tended to have slightly higher resistivities in both the alluvium/fill and the Walnut Formation than the transects in the west parking lot. The higher resistivities in the alluvium/fill could have been caused by drier conditions in grassy areas relative to conditions in the west parking lot. Higher resistivities in parts of the Walnut Formation also could be a function of drier conditions or variations in the lithology of the Walnut Formation. In addition to the 10 vertical sections, four horizontal sections at 2-meteraltitude intervals show generally increasing resistivity with decreasing altitude that most likely results from the increased influence of the Walnut Formation, which has a higher resistivity than the terrace alluvium/fill.

Texas

Computed and estimated pollutant loads, West Fork Trinity River, Fort Worth, Texas, 1997

In 1998 the U.S. Geological Survey, in cooperation with the Trinity River Authority, did a study to estimate storm-runoff pollutant loads using two models—a deterministic model and a statistical model; the estimated loads were compared to loads computed from measured data for a large (118,000 acres) basin in the Dallas-Fort Worth, Texas, metropolitan area. Loads were computed and estimated for 12 properties and constituents in runoff from two 1997 storms at streamflow-gaging station 08048543 West Fork Trinity River at Beach Street in Fort Worth. Each model uses rainfall as a primary variable to estimate pollutant load. In addition to using point rainfall at the Beach Street station to estimate pollutant loads, areal-averaged rainfall for the basin was computed to obtain a more representative estimate of rainfall over the basin. Loads estimated by the models for the two storms, using both point and areal-averaged rainfall, generally did not compare closely to computed loads for the 12 water-quality properties and constituents. Both models overestimated loads more frequently than they underestimated loads. The models tended to yield similar estimates for the same property or constituent. In general, areal-averaged rainfall data yielded better estimates of loads than point rainfall data for both models. Neither the deterministic model nor the statistical model (both using areal-averaged rainfall) was consistently better at estimating loads. Several factors could account for the inability of the models to estimate loads closer to computed loads. Chief among them is the fact that neither model was designed for the specific application of this study.

Texas

Phreatophyte influence on reductive dechlorination in a shallow aquifer contaminated with trichloroethene (TCE)

Phytoremediation uses the natural ability of plants to degrade contaminants in groundwater. A field demonstration designed to remediate aerobic shallow groundwater contaminated with trichloroethene began in April 1996 with the planting of cottonwood trees, a short-rotation woody crop, over an approximately 0.2-ha area at the Naval Air Station, Fort Worth, Texas. The project was developed to demonstrate capture of contaminated groundwater and degradation of contaminants by phreatophytes. Analyses from samples of groundwater collected from July 1997 to June 1998 indicate that tree roots have the potential to create anaerobic conditions in the groundwater that will facilitate degradation of trichloroethene by microbially mediated reductive dechlorination. Organic matter from root exudates and decay of tree roots probably stimulate microbial activity, consuming dissolved oxygen. Dissolved oxygen concentrations, which varied across the site, were smallest near a mature cottonwood tree (about 20 years of age and 60 meters southwest of the cottonwood plantings) where degradation products of trichloroethene were measured. Oxidation of organic matter is the primary microbially mediated reaction occurring in the groundwater beneath the planted trees whereas near the mature cottonwood tree, data indicate that methanogenesis is the most probable reaction occurring. Reductive dechlorination in groundwater either is not occurring or is not a primary process away from the mature tree. Carbon-13 isotope values for trichloroethene are nearly identical at locations away from the mature tree, further confirming that dechlorination is not occurring at the site.

Texas

Hydrogeology and simulation of ground-water flow in the Paluxy aquifer in the vicinity of Landfills 1 and 3, U.S. Air Force Plant 4, Fort Worth, Texas

Ground-water contamination of the surficial terrace alluvial aquifer has occurred at U.S. Air Force Plant 4, a government-owned, contractor-operated facility, northwest of Fort Worth, Texas. A poorly constructed monitoring well, P–22M, open to the underlying middle zone of the Paluxy aquifer was installed at landfill 3, October 1987, allowing leakage of contaminated ground water to reach the Paluxy aquifer. This well was plugged and abandoned in November 1995. Additionally, volatile organic compounds have been detected in fractures in the Goodland-Walnut confining unit, the hydrogeologic unit separating the terrace alluvial aquifer from the underlying Paluxy aquifer, beneath the western part of landfill 1. Volatile organic compounds in concentrations near the analytical detection limit were detected in the upper Paluxy prior to the drilling of well P–22M. The ground-water-flow simulation model described in this report was developed to examine the best logistically feasible location to install recovery wells to capture the low concentration (less than 100 micrograms per liter) trichloroethylene plume beneath landfills 1 and 3 (west Paluxy plume). Once the recovery wells were installed (1996), the simulation model was recalibrated with new data. This report documents the capture area of the installed recovery wells. Four geologic units are pertinent to this site-specific model. From oldest to youngest, these are the Glen Rose Formation, Paluxy Formation, Walnut Formation, and Goodland Limestone. The Glen Rose Formation is relatively impermeable in the study area and forms the confining unit underlying the Paluxy Formation. The Paluxy Formation forms the Paluxy aquifer, which is a public drinking water supply for the City of White Settlement. The Walnut Formation and Goodland Limestone form the Goodland-Walnut confining unit overlying the Paluxy aquifer. Near landfill 3, gamma-ray logs indicate three distinct zones of the Paluxy Formation; upper, middle, and lower. The formation is about 170-feet thick near landfill 3, and each zone is about 57-feet thick. Two steady-state simulations using the computer program MODFLOW were analyzed using the particle-tracking computer program, MODPATH. One simulation is the calibration simulation using Paluxy aquifer water-level data for May 1993. The second simulation includes the installed recovery wells. A variably spaced grid was designed for the model. The smallest grid cells, 25 by 25 feet, are in the vicinity of landfills 1 and 3. The largest cells, 4,864.5 by 1,441.5 feet, are at the northwestern corner of the model grid near the Parker-Tarrant County line. The modeling was accomplished with three layers representing the upper, middle, and lower zones of the Paluxy aquifer. Particles, which represent contaminant molecules moving in solution with the ground water, were tracked from well P–22M and an area below landfill 1, at the top of the upper zone of the Paluxy aquifer, for 9 years (forward tracking). The forward tracking estimates where contaminants might move by advection from 1987 to 1996. Analysis of backward tracking from the new recovery wells indicates that the simulated contributing area to the recovery wells intercepts the contaminant plume, minimizing off-site migration of the west Paluxy plume. To determine the effectiveness of the recovery wells, monitoring wells southeast of Building 14 have been installed (1996–97) for sampling.

Texas