Geology ReportsSearch

Geology topics

Research about Edwards-Trinity aquifer system

Source-linked reports with geographic coverage including Edwards-Trinity aquifer system.

5 recordsLinked to original sources

Hydrogeologic framework of the Edwards-Trinity aquifer system, west-central Texas

The Edwards-Trinity aquifer system underlies about 42,000 square miles of west-central Texas, where mostly gently dipping Lower Cretaceous strata comprise three regional aquifers and two regional confining units. The aquifers are the Edwards Aquifer of the Balcones fault zone, the Trinity Aquifer of the Balcones fault zone and Hill County, and the Edwards-Trinity Aquifer of the Edwards Plateau and Trans-Pecos. The Navarro-Del Rio confining unit confines the downdip part of the Edwards Aquifer, and the Hammett confining unit confines the updip, basal part of the Trinity Aquifer and a small southeastern fringe of the Edwards-Trinity Aquifer. Transmissivity averages less than 10,000 feet squared per day throughout more than 90 percent of the study area as the result of widespread cementation and secondary mineral growth. However, in fractured and leached rocks in the Balcones fault zone, transmissivity averages about 750,000 feet squared per day in the Edwards aquifer, which occupies less than 10 percent of the area.

Texas

Dissolved-solids concentrations and hydrochemical facies in water of the Edwards-Trinity aquifer system, west-central Texas

Much of the Edwards-Trinity aquifer system contains freshwater, but sizable parts contain marginally fresh or slightly saline water. The predominant water type in the aquifer system is calcium bicarbonate; however, one of seven other hydrochemical facies characterizes the water in places. The median dissolved-solids concentration of water samples from the Edwards aquifer in the Balcones fault zone is 297 mg/L (milligrams per liter); the interquartile range is 93 mg/L. In the freshwater zone of the Edwards aquifer updip of a freshwater/saline-water transition zone, the water is almost exclusively calcium bicarbonate. The median dissolved-solids concentration of water samples from the Trinity aquifer in the Hill Country is 537 mg/L and the interquartile range is 573 mg/L. Four bicarbonate and sulfate facies, spread vertically throughout the saturated section, characterize most of the Hill Country analyses; calcium bicarbonate predominates. The median concentration of dissolved solids in water samples from the Edwards-Trinity aquifer in the Edwards Plateau is 379 mg/L and the interquartile range is 547 mg/L. Freshwater is nearly everywhere in the southern and northeastern parts of the aquifer, and mostly slightly saline water is in the northwestern part. The distribution of hydrochemical facies shows a similar pattern to dissolved-solids concentration, with bicarbonate water nearly everywhere in the southern and northeastern parts of the aquifer. Sulfate and chloride facies characterize the northwestern part of the Edwards Plateau. The median concentration of dissolved solids among water samples from the Edwards-Trinity aquifer in the Trans-Pecos is 929 mg/L and the interquartile range is 1,626 mg/L. Fresh, calcium bicarbonate water predominates in the southern part, and more saline mixed and sulfate waters are the most common in the northwestern part.

Texas

Geologic history and hydrogeologic setting of the Edwards-Trinity aquifer system, west-central Texas

The Edwards-Trinity aquifer system underlies about 42,000 square miles of west-central Texas. Nearly flat-lying, mostly Comanche (Lower Cretaceous) strata of the aquifer system thin northwestward atop massive pre-Cretaceous rocks that are comparatively impermeable and structurally complex. From predominately terrigenous clastic sediments in the east and fluvialdeltaic (terrestrial) deposits in the west, the rocks of early Trinitian age grade upward into supratidal evaporitic and dolomitic strata, intertidal limestone and dolostone, and shallow-marine, openshelf, and reefal strata of late Trinitian, Fredericksburgian, and Washitan age. A thick, downfaulted remnant of mostly open-marine strata of Eaglefordian through Navarroan age composes a small, southeastern part of the aquifer system. The Trinity Group was deposited atop a rolling peneplain of pre-Cretaceous rocks during three predominately transgressive cycles of sedimentation that encroached upon the Llano uplift. The Fredericksburg and Washita Groups were deposited above the Trinity Group mostly in the lee of the Stuart City reef trend, a shelf margin ridge that sheltered depositional environments in the study area. The Washita Group subsequently was covered with thick, mostly fine-grained Gulf strata. During late Oligocene through early Miocene time, large-scale normal faulting formed the Balcones fault zone, where the Cretaceous strata were downfaulted, intensively fractured, and differentially rotated within a series of northeasttrending fault blocks. In addition to fracturing the rocks in the fault zone and extending the depth of freshwater diagenesis, the faulting vertically displaced the terrain, which steepened hydraulic gradients and maintained relatively high flow velocities near the surface. A shallow regime of dynamic ground-water flow evolved that promoted dissolution and enhanced the transmissivity of the Edwards Group in the Balcones fault zone. Cementation, recrystallization, and mineral replacement caused by deeper, comparatively sluggish ground-water circulation combined to diminish the transmissivity of the underlying Trinity Group, as well as most Cretaceous strata in the Hill Country, Edwards-Plateau, and Trans-Pecos. The Trinity, Fredericksburg, and Washita strata compose a regional aquifer system of three aquifers, whose water-transmitting characteristics generally are continuous in the lateral direction, and two hydraulically tight confining units. The aquifers are the Edwards aquifer in the Balcones fault zone, the Trinity aquifer in the Balcones fault zone and Hill Country, and the Edwards-Trinity aquifer in the Edwards Plateau and Trans-Pecos. The Navarro-Del Rio confining unit overlies the subcrop of the Edwards aquifer, and the Hammett confining unit lies within the updip, basal part of the Trinity aquifer and a small southeastern fringe of the Edwards-Trinity aquifer. The confining units are mostly calcareous mudstone, siltstone, and shale of low-energy terrigenous and openshelf marine depositional environments. The aquifers mainly result from fractures, joint cavities, and porosity caused by the dissolution of evaporites and unstable carbonate constituents. Because the diagenetic effects of cementation, recrystallization, and mineral replacement diminish the hydraulic conductivity of most rocks composing the Trinity and Edwards-Trinity aquifers, transmissivity values average less than 10,000 feet squared per day over more than 90 percent of the study area. However, the effects of tectonic fractures and dissolution in the Balcones fault zone cause transmissivity values to average about 750,000 feet squared per day in the Edwards aquifer, which occupies less than 10 percent of the study area.

Texas

Historical saturated thickness of the Edwards-Trinity aquifer system and selected contiguous hydraulically connected units, west-central Texas

The Edwards-Trinity Regional Aquifer-System Analysis (RASA) is one of 25 completed or ongoing studies conducted by the U.S. Geological Survey on regional aquifer systems that individually provide essential quantities of ground water to large parts of the country. Underlying about 42,000 mi 2 of west-central Texas, the Edwards-Trinity aquifer system extends approximately from Atascosa County in the southeast to Culberson County in the northwest and from the Rio Grande in the southwest to the Colorado River in the northeast (sheet 2). The Edwards-Trinity aquifer system spans four geographic subareas: Trans-Pecos, Edwards Plateau, Hill Country, and Balcones fault zone (fig. 1). The names of all aquifers in the study area were adopted for RASA purposes directly from nomenclature mandated by the Texas Water Plan (Texas Water Development Board, 1990). The Cretaceous rocks that compose the Edwards-Trinity aquifer system are primarily limestone and dolomite rock, with lesser quantities of terrigenous sand. Although the lithology varies locally and the rocks are not everywhere permeable in all directions, they combine to form a single regional aquifer system. The aquifer system comprises three aquifers and two confining units (figs. 2 and 3). The water-yielding units are the Edwards aquifer of the Balcones fault zone, the Trinity aquifer of the Balcones fault zone and Hill Country, and the Edwards-Trinity aquifer of the Edwards Plateau and Trans-Pecos. The confining units are the Hammett confining unit, which confines basal parts of the Trinity aquifer in the Hill Country and the Edwards-Trinity aquifer in the eastern part of the Edwards Plateau, and the Navarro-Del Rio confining unit, which confines the Edwards and Trinity aquifers along the southeastern margin of the Balcones fault zone. Parts of the aquifer system not overlain by one of these confining units are unconfined, or nearly so. The purposes of this report are to illustrate the historical distribution of saturated thickness (hereafter referred to as the saturated thickness) in the Edwards-Trinity aquifer system, summarize the reasons for the variation in the saturated thickness, and relate the regional effects of this variation to the distribution of transmissivity. The saturated thickness map (sheet 2) was determined for most of the area by subtracting the altitude of the base of the aquifer system (Barker and Ardis, 1992) from the altitude of the historical potentiometric surface (Bush and others, 1993). Where the Edwards and Trinity aquifers are confined in the Balcones fault zone, the saturated thickness is defined by the thickness of the aquifer system, which was determined by subtracting the altitude of the base of the aquifer system from the altitude of the base of the Navarro-Del Rio confining unit (G.E. Groschen and W.G. Stein, U.S. Geological Survey, written commun, 1990).

Texas

Configuration of the base of the Edwards-Trinity aquifer system and hydrogeology of the underlying pre-Cretaceous rocks, west-central Texas

The Edwards-Trinity aquifer system is underlain by an extensive complex of rocks, ranging from Late Cambrian through Late Triassic in age, that are typically about 10 to perhaps 1,000 times less permeable than those composing the aquifer system. The Cretaceous rocks of the aquifer system are separated from the pre-Cretaceous rocks by an unconformity that spans about 60 million years of erosion during the Jurassic Period. The upper surface of the pre-Cretaceous rock complex forms the base of the Edwards-Trinity aquifer system. The configuration of the base reflects the original topography of the eroded pre-Cretaceous land surface plus the effects of subsequent deformation. The most permeable pre-Cretaceous rocks are in the eastern half of the study area where they compose the Hickory aquifer (in Upper Cambrian rocks), Ellenburger-San Saba aquifer (Upper Cambrian- Lower Ordovician), and Marble Falls aquifer (Lower Pennsylvanian). These aquifers are hydraulically connected to the northeastern fringe of the Edwards-Trinity aquifer system, as their up-turned margins crop out around the flanks of the breached Llano uplift. The Rustler aquifer in rocks of Late Permian age underlies parts of the Trans-Pecos region, where it yields small amounts of greatly mineralized water for industrial and agricultural purposes. The Dockum aquifer in rocks of Late Triassic age directly underlies the Edwards-Trinity aquifer system in western parts of the study area, and locally increases the saturated thickness of the ground-water-flow system by an average of about 200 feet. Despite these notable exceptions, the collective effect of the pre-Cretaceous rocks is that 01 a barrier to ground-water flow, which limits the exchange of water across the base of the Edwards-Trinity aquifer system.

Texas