Geology ReportsSearch

Geology topics

Research about Corpus Christi, Texas

Source-linked reports with geographic coverage including Corpus Christi, Texas.

6 recordsLinked to original sources

Accuracy assessment of a mobile terrestrial lidar survey at Padre Island National Seashore

The higher point density and mobility of terrestrial laser scanning (light detection and ranging (lidar)) is desired when extremely detailed elevation data are needed for mapping vertically orientated complex features such as levees, dunes, and cliffs, or when highly accurate data are needed for monitoring geomorphic changes. Mobile terrestrial lidar scanners have the capability for rapid data collection on a larger spatial scale compared with tripod-based terrestrial lidar, but few studies have examined the accuracy of this relatively new mapping technology. For this reason, we conducted a field test at Padre Island National Seashore of a mobile lidar scanner mounted on a sport utility vehicle and integrated with a position and orientation system. The purpose of the study was to assess the vertical and horizontal accuracy of data collected by the mobile terrestrial lidar system, which is georeferenced to the Universal Transverse Mercator coordinate system and the North American Vertical Datum of 1988. To accomplish the study objectives, independent elevation data were collected by conducting a high-accuracy global positioning system survey to establish the coordinates and elevations of 12 targets spaced throughout the 12 km transect. These independent ground control data were compared to the lidar scanner-derived elevations to quantify the accuracy of the mobile lidar system. The performance of the mobile lidar system was also tested at various vehicle speeds and scan density settings (e.g. field of view and linear point spacing) to estimate the optimal parameters for desired point density. After adjustment of the lever arm parameters, the final point cloud accuracy was 0.060 m (east), 0.095 m (north), and 0.053 m (height). The very high density of the resulting point cloud was sufficient to map fine-scale topographic features, such as the complex shape of the sand dunes.

Texas

Archive of digital and digitized analog boomer seismic reflection data collected during USGS cruise 96CCT02 in Copano, Corpus Christi, and Nueces Bays and Corpus Christi Bayou, Texas, July 1996

In June of 1996, the U.S. Geological Survey conducted geophysical surveys from Nueces to Copano Bays, Texas. This report serves as an archive of unprocessed digital boomer seismic reflection data, trackline maps, navigation files, GIS information, cruise log, and formal FGDC metadata. Filtered and gained digital images of the seismic profiles and high resolution scanned TIFF images of the original paper printouts are also provided. The archived trace data are in standard Society of Exploration Geophysicists (SEG) SEG-Y format (Barry and others, 1975) and may be downloaded and processed with commercial or public domain software such as Seismic Unix (SU). Example SU processing scripts and USGS software for viewing the SEG-Y files (Zihlman, 1992) are also provided.

Texas

Evaluation of pore-water samplers at a drainage ditch, Installation Restoration Site 4, Naval Air Station Corpus Christi, Corpus Christi, Texas, 2005–06

The U.S. Geological Survey, in cooperation with the Naval Facilities Engineering Command Southeast, used innovative sampling methods to investigate ground-water contamination by chlorobenzenes beneath a drainage ditch on the southwestern side of Installation Restoration Site 4, Naval Air Station Corpus Christi, Corpus Christi, Texas, during 2005-06. The drainage ditch, which is a potential receptor for ground-water contaminants from Installation Restoration Site 4, intermittently discharges water to Corpus Christi Bay. This report evaluates a new type of pore-water sampler developed for this investigation to examine the subsurface contamination beneath the drainage ditch. The new type of pore-water sampler appears to be an effective approach for long-term monitoring of ground water in the sand and organic-rich mud beneath the drainage ditch.

Texas

Simulated effects of projected pumping on the availability of freshwater in the Evangeline Aquifer in an area southwest of Corpus Christi, Texas

This study is an investigation of the continued availability of freshwater in the Evangeline aquifer along the Texas Gulf Coast and the potential for degradation of the water quality by salinewater intrusion. Recharge to the aquifer occurs by the infiltration of precipitation in the outcrop area and by cross-formational flow from deeper aquifers. The predevelopment recharge rate is about 6 to 8 cubic feet per second. The predevelopment flow is toward the coast. The flow is semiconfined in the outcrop area and confined underneath the Chicot aquifer in the eastern two-thirds of the study area. Discharge, under natural conditions, is upward into the Chicot aquifer and to the Nueces River or Gulf of Mexico. Intensive pumping by irrigators, industries, and municipalities over the last 80 years has created a cone of depression as deep as 219 feet below sea level under the city of Kingsville in Kleberg County. The total rate of pumpage in 1982 was 29.6 cubic feet per second. A mathematical model of the flow and water quality in the Evangel ine aquifer was developed using available data to simulate the historical effect of pumping on the potentiometric surface and water quality, and to simulate the effect of projected pumping on the potentiometric surface and water quality to the year 2020. The water quality in the aquifer is only marginally suitable for drinking water. The chloride concentration before development in the 1930's and 1940's, ranged from 9 to 1,971 milligrams per liter. The mean chloride concentration was 353 (standard deviation 262) milligrams per liter. The potential sources of water-quality degradation on a regional scale are: Salinewater intrusion from under the Gulf of Mexico; movement of poor quality water within outlying sections of the aquifer; and downward leakage from the overlying Chicot aquifer. Leakage from the Chicot is the most likely to cause serious regional water-quality degradation. Other local potential sources of contamination are: Leaky well casings, oil-field brine disposal, water movement along faults, and in-situ uranium mining. These sources might create some local water-quality degradation. The results of the historical period simulation indicate, as do current field data, that little or no significant deterioration has occurred in the water quality of the Evangeline aquifer. The simulations and the sensitivity tests of the aquifer properties, conditions, and assumptions indicate that vertical conductivity of the Chicot aquifer is the most sensitive and least well known part of the system. The storage coefficient of the Evangeline aquifer and the aggregate thickness of high-conductivity sand layers within the aquifer as well as the vertical distribution of these layers are also important properties that are not well known. Two simulations of the projected pumping a low estimate, as much as 46.2 cubic feet per second during 2011-20; and a high estimate, as much as 60.0 cubic feet per second during the same period indicate that no further regional water-quality deterioration is likely to occur. Many important properties and conditions are estimated from poor or insufficient field data, and possible ranges of these properties and conditions are tested. In spite of the errors and data deficiencies, the results are based on the best estimates currently available. The reliability of the conclusions rests on the adequacy of the data and the demonstrated sensitivity of the model results to errors in estimates of these properties.

Texas

Parathion causes secondary poisoning in a laughing gull breeding colony

Use of organophosphate insecticides as replacements for the more persistent organochlorine compounds has increased dramatically in recent years. Organophosphates are desirable for field application because they break down rapidly in the environment and do not persist in animal tissues (Stickel 1974). Nevertheless, certain organophosphates are extremely toxic to wildlife for short periods after application and have caused widespread mortality among exposed animals (Mills 1973, Stickel 1974, 1975, Mendelssohn 1977, and Zinkl et al. 1978).

Texas