Geology ReportsSearch

Geology topics

Research about Columbia Plateau Regional Aquifer System

Source-linked reports with geographic coverage including Columbia Plateau Regional Aquifer System.

4 recordsLinked to original sources

Groundwater availability of the Columbia Plateau Regional Aquifer System, Washington, Oregon, and Idaho

The Columbia Plateau Regional Aquifer System (CPRAS) covers about 44,000 square miles of southeastern Washington, northeastern Oregon, and western Idaho. The area supports a $6-billion per year agricultural industry, leading the Nation in production of apples, hops, and eight other commodities. Groundwater pumpage and surface-water diversions supply water to croplands that account for about 5 percent of the Nation’s irrigated lands. Groundwater also is the primary source of drinking water for the more than 1.3 million people in the study area. Increasing competitive demands for water for municipal, fisheries/ecosystems, agricultural, domestic, hydropower, and recreational uses must be met by additional groundwater withdrawals and (or) by changes in the way water resources are allocated and used throughout the hydrologic system. As of 2014, most surface-water resources in the study area were either over allocated or fully appropriated, especially during the dry summer season. In response to continued competition for water, numerous water-management activities and concerns have gained prominence: water conservation, conjunctive use, artificial recharge, hydrologic implications of land-use change, pumpage effects on streamflow, and effects of climate variability and change. An integrated understanding of the hydrologic system is important in order to implement effective water-resource management strategies that address these concerns. To provide information to stakeholders involved in water-management activities, the U.S. Geological Survey (USGS) Groundwater Resources Program assessed the groundwater availability as part of a national study of regional systems (U.S. Geological Survey, 2008). The CPRAS assessment includes: The present status of groundwater resources, How these resources have changed over time, and Development and application of tools to estimate system responses to stresses from future uses and climate variability and change. This effort builds on previous investigations, especially the USGS Columbia Plateau Regional Aquifer-System Analysis study (CP-RASA). A major product of this new assessment is a numerical groundwater-flow model of the system. The model was used to estimate water-budget components of the hydrogeologic units composing the groundwater system, and to evaluate groundwater availability under existing land- and water-use conditions and a possible future climate scenario representing an increase in pumpage demand due to a warming climate. Information from this study also allowed for analysis of: The CPRAS for predevelopment times (pre-1920), Variations from 1920 through 2007, Conditions during 1985–2007 (referred to as “existing conditions”), and Changes in the system from predevelopment times. The model also is a useful tool for investigating water supply, water demand, management strategies, groundwater-surface water exchanges, and potential effects of changing climate on the hydrologic system.

Idaho, Oregon, Washington

Numerical simulation of groundwater flow in the Columbia Plateau Regional Aquifer System, Idaho, Oregon, and Washington

A three-dimensional numerical model of groundwater flow was constructed for the Columbia Plateau Regional Aquifer System (CPRAS), Idaho, Oregon, and Washington, to evaluate and test the conceptual model of the system and to evaluate groundwater availability. The model described in this report can be used as a tool by water-resource managers and other stakeholders to quantitatively evaluate proposed alternative management strategies and assess the long‑term availability of groundwater. The numerical simulation of groundwater flow in the CPRAS was completed with support from the Groundwater Resources Program of the U.S. Geological Survey Office of Groundwater. The model was constructed using the U.S. Geological Survey modular three-dimensional finite-difference groundwater-flow model, MODFLOW-NWT. The model uses 3-kilometer (9,842.5 feet) grid cells that subdivide the model domain by 126 rows and 131 columns. Vertically, the model domain was subdivided into six geologic model units. From youngest to oldest, the units are the Overburden, the Saddle Mountains Basalt, the Mabton Interbed, the Wanapum Basalt, the Vantage Interbed, and the Grande Ronde Basalt. Natural recharge was estimated using gridded historical estimates of annual precipitation for the period 1895–2007. Pre-development recharge was estimated to be the average natural recharge for this period. Irrigation recharge and irrigation pumping were estimated using a remote-sensing based soil-water balance model for the period 1985–2007. Pre-1985 irrigation recharge and pumping were estimated using previously published compilation maps and the history of large-scale irrigation projects. Pumping estimates for municipal, industrial, rural, residential, and all other uses were estimated using reported values and census data. Pumping was assumed to be negligible prior to 1920. Two models were constructed to simulate groundwater flow in the CPRAS: a steady-state predevelopment model representing conditions before large-scale pumping and irrigation altered the system, and a transient model representing the period 1900–2007. Automated parameter-estimation techniques (steady-state predevelopment model) and traditional trial-and-error (transient model) methods were used for calibration. To calibrate the steady-state and transient models, 10,525 and 46,460 water level measurements, respectively, and 50 base-flow estimates were used. The steady-state model simulated the shape, slope, and trends of a potentiometric surface that was generally consistent with mapped water levels. For the transient model, the mean and median difference between simulated and measured hydraulic heads is -10 and 4 ft, respectively, with a standard deviation of 164 ft over a 5,648 ft range of measured heads. The residuals for the simulation period show that 52 percent of the simulated heads exceeded measured heads with a median residual value of 43 ft, and 48 percent were less than measured heads with a median residual value of -76 ft. The CPRAS model was constructed to derive components of the groundwater budget and help understand the interactions of stresses, such as recharge, groundwater pumping, and commingling wells on the groundwater and surface-water system. Through these applications, the model can be used to identify trends in groundwater storage and use, and quantify groundwater availability. The annual groundwater budgets showed several patterns of change over the simulation period. Groundwater pumping was negligible until the 1950s and began to increase significantly during the 1970s and 1980s. Recharge was highly variable due to the interannual variability of precipitation, but began to increase in the late 1940s due to the increase in surface-water irrigation projects. Groundwater contributions to streamflow (base flow) followed recharge closely. However, in areas of significant groundwater-level decline, base flow is reduced. Groundwater pumping had the greatest effect on water levels, followed by irrigation enhanced recharge. Commingling was a larger factor in structurally complex upland areas where hydraulic-head gradients are naturally high. Groundwater pumping has increased substantially over the past 40–50 years; this increase resulted in declining water levels at depth and decreased base flows over much of the study area. The effects of pumping are mitigated somewhat by the increase of surface-water irrigation, especially in the shallow Overburden unit, and commingling wells in some areas. During dry to average years, groundwater pumping causes a net loss of groundwater in storage and current condition (2000–2007) groundwater pumping exceeds recharge in all but the wettest of years.

Idaho, Oregon, Washington

Groundwater conditions during 2009 and changes in groundwater levels from 1984 to 2009, Columbia Plateau Regional Aquifer System, Washington, Oregon, and Idaho

Groundwater elevations in three basalt units and one unconsolidated hydrogeologic unit in the Columbia Plateau Regional Aquifer System were measured and evaluated to provide a regional overview of groundwater conditions in spring 2009. Water levels for the Saddle Mountains unit, the Wanapum unit, the Grande Ronde unit, and for the overlying Overburden unit were measured in 1,752 wells during spring 2009 by the U.S. Geological Survey (USGS) and 10 other Federal, State, Tribal, and local agencies, including 66 wells located and measured by the USGS specifically for this study. These data were analyzed to determine the presence of spatial correlation of groundwater levels with distance and direction from each other. Groundwater flow in the Palouse Slope structural region showed evidence of being more continuous relative to groundwater flow in the Yakima Fold Belt, where the geologic complexity may contribute to compartmentalization of groundwater flow. This information was used to interpolate the generalized groundwater elevations for each of the basalt hydrogeologic units and to provide information on regional flow. Water-level change maps were constructed for the three basalt hydrogeologic units and the Overburden (unconsolidated) unit. Groundwater levels measured in spring 1984 and 2009 in 470 wells were compared. Small to moderate groundwater-level declines were measured in most wells, although declines greater than 100 ft and as great as 300 ft were measured in many wells. Essentially unchanged groundwater levels were measured in other wells. Of the wells measured in 1984 and 2009, water levels declined in 83 percent of the wells, and declines greater than 25 ft were measured in 29 percent of all wells. The groundwater-level changes were greatest in the deeper hydrogeologic units. Mean groundwater-level changes ranged from a 7 ft decline for the Overburden unit to a 51 ft decline for the Grande Ronde unit. The average annual rates of groundwater-level change for the 25-year period ranged from a 0.3 ft/yr decline for the Overburden unit to a 2.0 ft/yr decline for the Grande Ronde unit. Groundwater level declines were identified throughout the Columbia Plateau, but areas with large and widespread declines were located in the central northern part of the study area, in parts of the Yakima River basin in Washington, in the Pullman-Moscow area in Washington and Idaho, and in parts of the Umatilla River basin in Oregon. These declines are in areas known to rely heavily on groundwater for irrigation and other uses.

Idaho, Oregon, Washington

Geologic Setting and Hydrogeologic Units of the Columbia Plateau Regional Aquifer System, Washington, Oregon, and Idaho

The Columbia Plateau Regional Aquifer System (CPRAS) covers approximately 44,000 square miles of northeastern Oregon, southeastern Washington, and western Idaho. The area supports a $6 billion per year agricultural industry, leading the Nation in production of apples and nine other commodities (State of Washington Office of Financial Management, 2007; U.S. Department of Agriculture, 2007). Groundwater availability in the aquifers of the area is a critical water-resource management issue because the water demand for agriculture, economic development, and ecological needs is high. The primary aquifers of the CPRAS are basalts of the Columbia River Basalt Group (CRBG) and overlying basin-fill sediments. Water-resources issues that have implications for future groundwater availability in the region include (1) widespread water-level declines associated with development of groundwater resources for irrigation and other uses, (2) reduction in base flow to rivers and associated effects on temperature and water quality, and (3) current and anticipated effects of global climate change on recharge, base flow, and ultimately, groundwater availability. As part of a National Groundwater Resources Program, the U.S. Geological Survey began a study of the CPRAS in 2007 with the broad goals of (1) characterizing the hydrologic status of the system, (2) identifying trends in groundwater storage and use, and (3) quantifying groundwater availability. The study approach includes documenting changes in the status of the system, quantifying the hydrologic budget for the system, updating the regional hydrogeologic framework, and developing a groundwater-flow simulation model for the system. The simulation model will be used to evaluate and test the conceptual model of the system and later to evaluate groundwater availability under alternative development and climate scenarios. The objectives of this study were to update the hydrogeologic framework for the CPRAS using the available geologic mapping and well information and to develop a digital, three-dimensional hydrogeologic model that could be used as the basis of a groundwater-flow model. This report describes the principal geologic and hydrogeologic units of the CPRAS and geologic map and well data that were compiled as part of the study. The report also describes simplified regional hydrogeologic sections and unit extent maps that were used to conceptualize the framework prior to development of the digital 3-dimensional framework model.

Idaho, Oregon, Washington